• Title/Summary/Keyword: Gamma probe

Search Result 84, Processing Time 0.021 seconds

Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution (감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

Molecular cloning of casein gane which is expressed in mammary glands (유선조직에서 특이적으로 발현되는 카제인 유전자의 클로닝(I))

  • Choe, In-Ho;Bae, Bong-Jin;Lee, Chang-Su
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.21 no.1
    • /
    • pp.53-66
    • /
    • 1995
  • The gene for ${\gamma}$-casein, a milk protein, is a member of a family of casein gene which is expressed in mammary glands of the animal during the late gestation and lactation periods binder the influence of various hormones. In order to elucidate tile mechanisms b)'which hormones regulate the coordinate induction of milk protein genes, the mouse ${\gamma}$-casein gene was isolated and characterized. The ${\gamma}$-casein gene was screened from a mouse genomic library constructed in bacteriophage EMBL3 with the ${\gamma}$-casein CDNA used as probe and one clone was obtained. The ${\gamma}$-casein CDNA as probe was partially sequenced and contained ATG start codon and 5'-noncoding region. The cloned genomic DNA was digested with Sal I restriction enzyme, by which the insert DNA can be isolated from EMBL3 vector. Three DNA bands were observed and the size of DNAs was approximately 28kb, 14kb and 9Kb, respectively Accordingly the size of the insert DNA was calculated with approximately 23Kb. The result of Southern blot analysis, however, showed that the cloned genomic DNA was not hybridized with the synthetic oligonucleotides (40 mer) of cDNA 5'-end region, but it was hybridized with the y -casein CDNA. This means that tile cloned y -casein gene may not contain its promoter region. The ${\gamma}$ -casein genomic DNA containing the promoter region has been screening from mouse genomic library with oligonucleotides of CDNA 5'-end region as probe, and twenty-nine clones was obtained.

  • PDF

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.

Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System (소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가)

  • Yang, Myo-Geun;Kwark, Cheol-Eun;Sim, yong-Geol;Kim, Hee-Joung;Choi, Yong;Chung, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

Development of Imaging Gamma Probe Using the Position Sensitive PMTube (위치 민감형 광전자증배관을 이용한 영상용 감마프로브의 개발)

  • Bong, Jeong-Gyun;Kim, Hui-Jung;So, Su-Gil;Kim, Han-Myeong;Lee, Jong-Du;Gwon, Su-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • The purpose of this study was to develop a miniature imaging gamma probe with high performance that can detect small or residual tumors after surgery. Gamma probe detector system consists of NaI(Tl) scintillator, position sensitive photomultiplier tube (PSPMT), and collimator. PSPMT was optically coupled with 6.5 mm thick, 7.62 cm diameter of NaI(Tl) crystal and supplied with -1000V for high voltage. Parallel hexagonal hole collimator was manufactured for characteristics of 40-mm hole length, 1.3-mm hole diameter, and 0.22 mm septal thickness. Electronics consist of position and trigger signal readout systems. Position signals were obtained with summing, subtracting, and dividing circuit using preamplifer and amplifier. Trigger signals were obtained using summing amplifier, constant fraction discriminator, and gate and delay generator module with preamplifer. Data acquisition and processing were performed by Gamma-PF interface board inserted into pentium PC and PIP software. For imaging studies, flood and slit mask images were acquired using a point source. Two hole phantom images were also acquired with collimator. Intrinsic and system spatial resolutions were measured as 3.97 mm and 5.97 mm, respectively. In conclusion, Miniature gamma probe images based on the PSPMT showed good image quality, we conclude that the miniature imaging gamma probe was successfully developed and good image data were obtained. However, further studies will be required to optimize imaging characteristics.

  • PDF

Development of Portable Gamma Probe and Its Basic Performance Test (이동형 감마프로브 개발과 기본성능 평가)

  • Kim, H.J.;Kwark, C.;Choi, Y.;Yang, M.K.;Bong, J.K.;Lee, S.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.216-219
    • /
    • 1997
  • We are developing a portable multipurpose gamma counting and imaging probe that will be useful for many applications in nuclear medicine including radioimmunoguided surgery in the detection and treatment of malignant tumors. Any diagnostic information provided by CT, MRI, PET, SPECT or gamma camera imaging prior to surgery obviously is very important, but current techniques are limited in many instances. To overcome some of these limitations, the portable multipurpose gamma probe is being developed. The gamma probe consists of NaI(Tl) crystal with 1" dia $\times$ 0.5" thick and singlechannel photomultiplier tube (SC-PMT) for counting, and 3" dia $\times$ 0.375" and multichannel photomultiplier tube (MC-PMT) for imaging, nuclear instrument module (NIM), position circuits, interface, and PC. The energy resolution using Tc-99m was measured as 14% and the spatial resolution using 3mm dia green LED was measured as 2.9mm. These priliminary results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine.

  • PDF

Diffusion of Probe Molecule in Small Liquid n-Alkanes: A Molecular Dynamics Simulation Study

  • Yoo, Choong-Do;Kim, Soon-Chul;Lee, Song-Hi
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.8
    • /
    • pp.1554-1560
    • /
    • 2008
  • The probe diffusion and friction constants of methyl yellow (MY) in liquid n-alkanes of increasing chain length were calculated by equilibrium molecular dynamics (MD) simulations at temperatures of 318, 418, 518 and 618 K. Lennard-Jones particles with masses of 225 and 114 g/mol are modeled for MY. We observed that the diffusion constant of the probe molecule follows a power law dependence on the molecular weight of nalkanes, DMY${\sim}M^{-\gamma}$ well. As the molecular weight of n-alkanes increases, the exponent $\gamma$ shows sharp transitions near n-dotriacontane ($C_{32}$) for the large probe molecule (MY2) at low temperatures of 318 and 418 K. For the small probe molecule (MY1) $D_{MY1}$ in $C_{12}$ to C80 at all the temperatures are always larger than Dself of n-alkanes and longer chain n-alkanes offer a reduced friction relative to the shorter chain n-alkanes, but this reduction in the microscopic friction for MY1 is not large enough to cause a transition in the power law exponent in the log-log plot of DMY1 vs M of n-alkane. For the large probe molecule (MY2) at high temperatures, the situation is very similar to that for MY1. At low temperatures and at low molecular weights of n-alkanes, $D_{MY2}$ are smaller than $D_{self}$ of n-alkanes due to the relatively large molecular size of MY2, and MY2 experiences the full shear viscosity of the medium. As the molecular weight of n-alkane increases, $D_{self}$ of n-alkanes decreases much faster than $D_{MY2}$ and at the higher molecular weights of n-alkane, MY2 diffuses faster than the solvent fluctuations. Therefore there is a large reduction of friction in longer chains compared to the shorter chains, which enhances the diffusion of MY2. The calculated friction constants of MY1 and MY2 in liquid n-alkanes supported these observations. We deem that this is the origin of the so-called“solventoligomer”transition.

Feasibility Study on Development of a Fiber-Optic Dual Detector to Measure Beta- and Gamma-rays Simultaneously (베타/감마 동시 측정용 광섬유 이중 검출기의 개발을 위한 기초연구)

  • Hong, Seunghan;Shin, Sang Hun;Sim, Hyeok In;Kim, Seon Geun;Jeon, Hyesu;Jang, Jaeseok;Kim, Jaeseok;Kwon, Guwon;Jang, Kyoung Won;Yoo, Wook Jae;Lee, Bongsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.284-290
    • /
    • 2014
  • A fiber-optic beta/gamma dual detector system with two types of sensing probes was fabricated to detect the beta- and gamma-rays simultaneously. As scintillators of the sensing probe type 1, two different inorganic scintillators, $CaF_2(Eu)$ and LYSO(Ce) crystals, were used to obtain the each scintillating efficiency with respect to beta-and gamma-rays and the inherent energy spectra of radioactive isotopes. In the case of the sensing probe type 2, which is composed of two identical inorganic scintillators and a beta shielding material based on the lead, it could discriminate beta- and gamma-rays using a subtraction method. In conclusion, we demonstrated that the proposed fiber-optic beta/gamma dual detector could measure and discriminate beta- and gamma-rays using both energy spectroscopy and subtraction method.

Amelanotic Melanoma on Fingertip: A Case Report (수지첨부에 발생한 멜라닌결핍흑색종의 치험례)

  • Paik, Hye Won;Kim, Sang Wha;Byeon, Jun Hee
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.312-315
    • /
    • 2008
  • Purpose: Amelanotic melanoma represents a melanoma with an absence or a small number of melanin pigments and comprises 2% of all melanomas. These melanomas are frequently misdiagnosed, probably because of its nonspecific clinical features and difficulty in diagnosis, resulting in delayed diagnosis and treatment. We report a patient with amelanotic melanoma, who underwent surgical treatment with sentinel lymph node biopsy using gamma probe. Methods: A 32-year-old female was presented with a slowly growing ill-defined, hypopigmented nonerythematous lesion with nail defect on right index finger tip. Preoperative punch biopsy was performed, showing an amelanotic melanoma. Sentinel lymph node biopsy was done using gamma probe(Crystal probe system, CRYSTAL PHOTONICS GmbH, Germany) and confirmed no evidence of regional lymph node metastases. The patient underwent amputation at the proximal interphalangeal joint. Results: Histopathologic findings showed superficial spreading melanoma. There were no melanin pigments in Hematoxylin & Eosin stain but positive immunohistochemical stainings for S-100 protein and Hmb45, which were consistent with amelanotic melanoma. Patient's postoperative course was uneventful without any complication and had no evidence of recurrence of tumor in 6 months follow-up period. Conclusion: Amelanotic melanoma is extremely rare subtype of malignant melanoma with histopathologic findings of atypical melanocytes without melanin pigments. Early detection is crucial since survival is strongly related to tumor thickness and tissue invasion at the time of diagnosis. Wide excision is the treatment of choice and other conjunctive therapy has not been successful.

A Comparative Study of Density Compensation in Gamma-Gamma Log in PVC Casings between above and below Ground Water Tables (지하수면 상.하부 환경에서의 PVC 케이싱 이격보정 비교 연구)

  • Kim, Yeong-Hwa;Hwang, Byong-Chol;Park, Sung-Geun;Kim, Jong-Man
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.217-225
    • /
    • 2009
  • A series of model borehole experiments and analyses for density compensation were performed to achieve the effective density correction of gamma-gamma log obtained from PVC cased boreholes. A follow-up survey was made for clarifying the variation property of detector responses depending on casing types, the presence of borehole fluid, and the degree of separation between probe and borehole wall. A special emphasis was placed on the comparison of gamma responses obtained from above and below ground water tables. Finally, we could quantify the detector responses as a function of separation between the probe and borehole wall, construct standoff compensation charts, and the limitations of the compensation have been discussed for the environments of both above and below ground water tables.