• 제목/요약/키워드: Gamma energy

검색결과 2,064건 처리시간 0.025초

CZT 반도체 검출기를 활용한 중성자 및 감마선 측정과 분석 기술에 관한 연구 (A Study on the Technology of Measuring and Analyzing Neutrons and Gamma-Rays Using a CZT Semiconductor Detector)

  • 진동식;홍용호;김희경;곽상수;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.57-67
    • /
    • 2022
  • CZT detectors, which are compound semiconductors that have been widely used recently for gamma-ray detection purposes, are difficult to detect neutrons because direct interaction with them does not occur unlike gamma-rays. In this paper, a method of detecting and determining energy levels (fast neutrons and thermal neutrons) of neutrons, in addition of identifying energy and nuclide of gamma-rays, and evaluating gamma dose rates using a CZT semiconductor detector is described. Neutrons may be detected by a secondary photoelectric effect or compton scattering process with a characteristic gamma-ray of 558.6 keV generated by a capture reaction (113Cd + 1n → 114Cd + 𝛾) with cadmium (Cd) in the CZT detector. However, in the case of fast neutrons, the probability of capture reaction with cadmium (Cd) is very low, so it must be moderated to thermal neutrons using a moderator and the material and thickness of moderator should be determined in consideration of the portability and detection efficiency of the equipment. Conversely, in the case of thermal neutrons, the detection efficiency decreases due to shielding effect of moderator itself, so additional CZT detector that do not contain moderator must be configured. The CZT detector that does not contain moderator can be used to evaluate energy, nuclide, and gamma dose-rate for gamma-rays. The technology proposed in this paper provides a method for detecting both neutrons and gamma-rays using a CZT detector.

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

한방약재의 오염 미생물 살균, 추출율 및 생리효능에 대한 감마선 조사의 영향 (Effects of Gamma Irradiation on Microbial Decontamination, Extraction Yields and Physiological Effectiveness of Korean Medicinal Plants)

  • 육홍선;차보숙;조성기;변명우
    • 한국식품과학회지
    • /
    • 제30권3호
    • /
    • pp.581-589
    • /
    • 1998
  • $5{\sim}10\;kGy$ 범위의 감마선 조사는 한방약재에 오염된 유기체를 완전사멸 시켜 저장중 미생물학적 품질 안전성을 가져왔으며, 한방약재의 유효성분 추출율을 약 $5{\sim}25%$ 증대시킬 뿐만 아니라 추출시간의 단축효과도 나타냈다. 또한 살균 및 유효성분의 추출율이 증대된 조사선량에서 한방약재의 몇 가지 생리적 활성(항산화력, 항보체능력, 아질산염 소거능, 전자공여능)은 비조사군과 차이를 보이지 않았다.

  • PDF

Headspace 법을 이용한 생굴 및 굴 자숙액의 감마선 조사에 의한 휘발성 냄새 성분 변화 분석 (Analysis of Volatile Flavor Compounds in Raw Oyster and Oyster Cooking Drips by Gamma Irradiation Using Headspace Method)

  • 최종일;김현주;이주운
    • KSBB Journal
    • /
    • 제26권2호
    • /
    • pp.177-181
    • /
    • 2011
  • This study was conducted to investigate the effects of gamma irradiation on the change of volatile flavor compounds of raw oyster and its cooking drips using headspace methods. Major volatile flavor compounds of the raw oyster were identified as methylthiomethane and 1,5-hexadiene. When the raw oyster was irradiated at the dose of 5 kGy, 1-pentane was newly detected. On the other hand, 9 compounds including N-methoxyformaldehyde were identified as the major volatile compounds of cooking drips from oyster. Among them, N-methoxyformaldehyde contents in cooking drip was decreased by the gamma irradiation. By the gamma irradiation above 30 kGy, new heterocyclic compounds was found in oyster cooking drips. Therefore, the amount of volatile flavor compounds in the raw oyster and cooking drips were changed by gamma irradiation, and these results could be potentially used in the seasoning industry.

이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발 (Development of Measurement System for Industrial Transportable Gamma Ray CT)

  • 김종범;정성희;문진호
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Effect of gamma irradiation on post-harvest quality of king oyster mushrooms (Pleurotus eryngii )

  • Seo-Joon Yeom;Geon-Ah Lee;Sang-Su Kim;Ki-Nam Yoon;Beom-Seok Song;Jong-Heum Park;Woo-Jin Jung;Young-Min Kim;Jae-Kyung Kim
    • 한국식품저장유통학회지
    • /
    • 제30권5호
    • /
    • pp.729-742
    • /
    • 2023
  • The consumption of king oyster mushrooms has steadily increased owing to their unique flavor and delicate texture. This study extended the storage period of king oyster mushrooms (Pleurotus eryngii ) via gamma irradiation. Irradiated samples (0, 0.5, 1, 2, and 3 kGy) were stored at 4℃ with 80% relative humidity for up to 28 days, and the experiments were conducted every 7 day. Microbiological analysis revealed a dose-dependent reduction in total aerobic bacteria, Pseudomonas spp., and yeasts and molds, and gamma irradiation above 2 kGy effectively controlled microbial contamination for up to 28 days. At the 28th day of storage, the irradiated king oyster mushrooms exhibited delayed browning through the reduction of tyrosinase activity. Moreover, firmness reduction (%) was 80.59±1.89% for the non-irradiated group and 42.80±1.28, 34.57±1.13, 31.05±3.24, and 39.73±0.94% for the irradiated group (0.5, 1, 2, and 3 kGy), respectively. These results were supported by the scanning electron microscopy photos, which showed smaller pores in the irradiated group than in the non-irradiated group. This study demonstrated that 2 kGy of gamma irradiation effectively reduces microbial contamination and delays the browning and softening of king oyster mushrooms for up to 28 days.

Crosslinking of Electrospun Poly (VDF-co-HFP) Nanofibrous Membranes by Gamma-ray Irradiation

  • Kim, Yun-Hye;Lim, Youn-Mook;Choi, Jae-Hak;An, Sung-Jun;Park, Jong-Seok;Nho, Young-Chang
    • 방사선산업학회지
    • /
    • 제2권3호
    • /
    • pp.105-110
    • /
    • 2008
  • Poly (VDF-co-HFP)/PEGDMA nanofibrous membranes (NFMs) have been prepared by an electrospinning process. Since electrospun NFMs have a nanoporous structure, they have a potential application for a polymer electrolyte or a separator. Poly (VDF-co-HFP) is a polymer electrolyte binder. In order to improve their mechanical properties, poly (VDF-co-HFP)/PEGDMA NFMs were crosslinked by a gamma-ray irradiation. Then the crosslinked NFMs were characterized through an electrolyte uptake, IR structural analysis, and SEM morphological investigation.