Analysis of the influence of nuclear facilities on environmental radiation by monitoring the highest nuclear power plant density region

  • Lee, UkJae;Lee, Chanki;Kim, Minji;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1626-1632
    • /
    • 2019
  • Monitoring of environmental radioactivity is essential for ensuring the radiological safety of residents who live near nuclear power plants. Ulsan, South Korea, is surrounded by 16 nuclear power plants, the highest density in the country. In addition, the city contains facilities for conducting radiological nondestructive testing and using radioisotopes for medical purposes. It makes the confirmation of radiological safety particularly necessary. In this study, sampling points were selected based on regional characteristics, and surface water samples were pretreated and analyzed for gross beta and gamma radiation levels. In addition, the distribution of the city's gamma dose rate was determined using a mobile monitoring system and distribution visualization program. The results showed that there is no effect on the gross beta and gamma nuclides of artificial radionuclides, and the gamma dose rate of the entire region did not exceed the environmental radiation level in South Korea overall, confirming the radiological safety of the city.

A fast gamma-ray dose rate assessment method for complex geometries based on stylized model reconstruction

  • Yang, Li-qun;Liu, Yong-kuo;Peng, Min-jun;Li, Meng-kun;Chao, Nan
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1436-1443
    • /
    • 2019
  • A fast gamma-ray dose rate assessment method for complex geometries based on stylized model reconstruction and point-kernel method is proposed in this paper. The complex three-dimensional (3D) geometries are imported as a 3DS format file from 3dsMax software with material and radiometric attributes. Based on 3D stylized model reconstruction of solid mesh, the 3D-geometrical solids are automatically converted into stylized models. In point-kernel calculation, the stylized source models are divided into point kernels and the mean free paths (mfp) are calculated by the intersections between shield stylized models and tracing ray. Compared with MCNP, the proposed method can implement complex 3D geometries visually, and the dose rate calculation is accurate and fast.

장기 중선량률 감마선 피폭에 의한 마우스의 생존율 및 생물학적 영향 평가 (Survival Rate and Biological Effect of Chronic Medium-Dose-Rate Gamma Radiation Exposed to Mice)

  • 김재경;진영배;오수미;이윤종;성낙윤;송범석;박종흠;변의백;이주운;김재훈
    • 방사선산업학회지
    • /
    • 제7권2_3호
    • /
    • pp.155-159
    • /
    • 2013
  • Late effects of chronic exposure to gamma radiation are potential hazards to worker in radiation facilities as well as to the general public. Recently, chronic gamma radiation exposure effects have become a serious concern. Using a total of 60 mice, we studied the biological effects of medium-dose chronic exposure to gamma radiation. Sixty female 6-week-old specific pathogen free Balb/c mice were randomly divided into six groups (five groups irradiated and one non-irradiated control group). Irradiation was carried out for 7 days using gamma rays at dose rates of 119.65, 238.10, 357.14, 476.19 and $595.24mGy\;h^{-1}$ with total doses 20, 40, 60, 80 and 100 Gy. After irradiation, we determined survival rate of gamma radiation exposed mice during 1 week and 476.19 and $595.24mGy\;h^{-1}$ exposed group mice showed less 10% of survival rate. Otherwise, 119.65, 238.10 and $357.14mGy\;h^{-1}$ exposed group mice were survived each 100%, 80% and 70%. Half of survived mice after 1 week are immediately sacrifice and counted body and spleen weights. Compared with control non-irradiated group, total body weights and spleen weights isolated from 119.65, 238.10 and 357.14 irradiated group mice showed significant decreased. However, no significant alteration was observed between 119.65, 238.10 and $357.14mGy\;h^{-1}$ irradiated group. Overall, our results show for the first time that medium-dose chronic gamma radiation has the potential to stimulation of biological effects.

Dose Estimation Model for Terminal Buds in Radioactively Contaminated Fir Trees

  • Kawaguchi, Isao;Kido, Hiroko;Watanabe, Yoshito
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.143-151
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, biological alterations in the natural biota, including morphological changes of fir trees in forests surrounding the power plant, have been reported. Focusing on the terminal buds involved in the morphological formation of fir trees, this study developed a method for estimating the absorbed radiation dose rate using radionuclide distribution measurements from tree organs. Materials and Methods: A phantom composed of three-dimensional (3D) tree organs was constructed for the three upper whorls of the fir tree. A terminal bud was evaluated using Monte Carlo simulations for the absorbed dose rate of radionuclides in the tree organs of the whorls. Evaluation of the absorbed dose targeted 131I, 134Cs, and 137Cs, the main radionuclides subsequent to the FDNPP accident. The dose contribution from each tree organ was calculated separately using dose coefficients (DC), which express the ratio between the average activity concentration of a radionuclide in each tree organ and the dose rate at the terminal bud. Results and Discussion: The dose estimation indicated that the radionuclides in the terminal bud and bud scale contributed to the absorbed dose rate mainly by beta rays, whereas those in 1-year-old trunk/branches and leaves were contributed by gamma rays. However, the dose contribution from radionuclides in the lower trunk/branches and leaves was negligible. Conclusion: The fir tree model provides organ-specific DC values, which are satisfactory for the practical calculation of the absorbed dose rate of radiation from inside the tree. These calculations are based on the measurement of radionuclide concentrations in tree organs on the 1-year-old leader shoots of fir trees. With the addition of direct gamma ray measurements of the absorbed dose rate from the tree environment, the total absorbed dose rate was estimated in the terminal bud of fir trees in contaminated forests.

광섬유 브래그 격자 센서를 이용한 국내외 상용 단일모드 광섬유의 감마선 영향 연구 (A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber using Fiber Bragg Grating Sensor Systems)

  • 김종열;이남호
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2287-2292
    • /
    • 2012
  • 본 논문에서는 Ge가 함유된 일반 단일모드 광섬유의 감마선 유입손실을 측정하였다. 방사선 선원은 $Co^{60}$ 감마선 선원을 이용하였으며, 총 4시간동안 0.5 kGy/hr, 2 kGy/hr, 8 kGy/hr의 선량률로 조사하였다. 그 결과 감마선 조사에 의한 단일모드 광섬유의 전송손실이 뚜렷하게 나타났으며, 동일 누적선량에서 선량률이 클수록 전송손실이 증가하는 선량률 효과가 나타났다. 또한 감마선 조사 종료 후 광섬유의 전송손실이 클수록 유입손실의 회복률이 증가하는 어닐링 특성을 보였다. 본 실험결과는 향후 광섬유의 내방사화 연구의 기초자료로 활용할 것이다.

Evaluating the Effects of Dose Rate on Dynamic Intensity-Modulated Radiation Therapy Quality Assurance

  • Kim, Kwon Hee;Back, Tae Seong;Chung, Eun Ji;Suh, Tae Suk;Sung, Wonmo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.116-121
    • /
    • 2021
  • Purpose: To investigate the effects of dose rate on intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We performed gamma tests using portal dose image prediction and log files of a multileaf collimator. Thirty treatment plans were randomly selected for the IMRT QA plan, and three verification plans for each treatment plan were generated with different dose rates (200, 400, and 600 monitor units [MU]/min). These verification plans were delivered to an electronic portal imager attached to a Varian medical linear accelerator, which recorded and compared with the planned dose. Root-mean-square (RMS) error values of the log files were also compared. Results: With an increase in dose rate, the 2%/2-mm gamma passing rate decreased from 90.9% to 85.5%, indicating that a higher dose rate was associated with lower radiation delivery accuracy. Accordingly, the average RMS error value increased from 0.0170 to 0.0381 cm as dose rate increased. In contrast, the radiation delivery time reduced from 3.83 to 1.49 minutes as the dose rate increased from 200 to 600 MU/min. Conclusions: Our results indicated that radiation delivery accuracy was lower at higher dose rates; however, the accuracy was still clinically acceptable at dose rates of up to 600 MU/min.

저선량 감마선이 채소 발아종자의 생리활성에 미치는 영향 (Influence of low dose ${\gamma}$ radiation on the physiology of germinative seed of vegetable crops)

  • 김재성;이은경;백명화;김동희;이영복
    • 한국환경농학회지
    • /
    • 제19권1호
    • /
    • pp.58-61
    • /
    • 2000
  • 묵은 파와 시금치 종자에 저선량 ${\gamma}$선을 조사하여 종자 발아율과 발아종자의 생리활성 변화를 관찰하였다. 시금치 종자의 발아율은 대조구에 비해 저선량 조사구에서 증가하는 경향을 보였고 특히 2 Gy와 1 Gy에서 효과적이였으나 파종자에서는 1 Gy 조사구만이 대조구에 비해 높은 발아율을 보였다. 저선량 ${\gamma}$선이 조사된 파와 시금치종자의 ion leakage 조사에서는 대조구에 비해 저선량 ${\gamma}$선 조사구에서 감소하는 경향을 보였는데 이는 특히 배양 초기 단계에서 뚜렸하였다. 전분 분해 또한 ${\gamma}$선 조사에 의해 촉진되었고 저선량의 γ선은 glutamic acid의 decarboxylation 으로 인해 종자의 활력을 유지하는 잇점이 있는 것으로 나타났다.

  • PDF

감마선분광분석기를 이용한 괴산 옥천하부천매암대 일대의 감마선량 평가 (Assessment of Gamma-radiation dose Rate in the Ogcheon Lower Phyllite Area, Goesan County, Korea, Using Gamma-ray Spectrometry)

  • 윤욱;조병욱
    • 지질공학
    • /
    • 제29권4호
    • /
    • pp.461-468
    • /
    • 2019
  • 휴대용 감마선분광분석기를 이용하여 괴산지역 옥천하부천매암대(og2) 주변 일대 77개 지점에서 감마선량을 측정하였다. 전체 시료의 40K 함량은 1.8-8.8% 범위(평균 4.6%)로 Kgr에서 함량이 가장 높았으 며, eU의 함량 범위는 0.2-217.9 ppm (평균 16.7 ppm)인데 og2에서 가장 높았으며(중앙값 29.6 ppm)다. eTh의 함량 범위는 11.9-76.5 ppm (평균 29.5 ppm) 이었는데 Kgr의 평균 함량은 45.4 ppm으로 og1, og2, og3의 함량(26.6-30.6 ppm)보다 높았다. og2에 속하는 일부 고 우라늄 지점을 제외한 연구지역의 감마선량에 기여하는 방사성물질은 40K가 절대적이다. 연구지역의 옥외 유효선량률은 0.08-1.71 mSv/y (평균 0.28 mSv/y)의 범위로 나타났다. 유효선량률이 1 mSv를 넘는 지점은 함 우라늄 층이 협재된 og2의 덕평리지역 3지점이며 이를 제외한 나머지 대부분 지역은 정상적인 자연방사선지역에 해당한다.

기내$\gamma$-선 처리에 의한 감(Diospyros kaki Thunb.) 돌연변이 유기 (Induction of Mutants by Irradiation of $\gamma$-Ray on In vitro Shoots of Persimmon)

  • 고갑천
    • 식물조직배양학회지
    • /
    • 제27권2호
    • /
    • pp.143-148
    • /
    • 2000
  • 감 돌연변이 획득을 위해 기내배양 신초에 ${\gamma}$-선을 조사하여 변이유기를 위한 적정 선량, ${\gamma}$-선 조사 식물체의 기내 발근 및 생육 특성을 조사한 결과는 다음과 같다. 감 돌연변이 유기를 위한 적정한 조사 선량 (LD$_{50}$)은 서촌조생 품종에서 1 krad와 2 krad사이이었고, 일목계차랑 품종은 1 krad이었다. ${\gamma}$-선을 조사한 신초를 1차,2차, 3차에 걸쳐 계대배양하는 각 기간의 기내 생육상태를 보면 ${\gamma}$-선량이 증가할수록 기내에서 생장한 신초의 길이가 감소하였으며, 신초의 정아가 가장 장애를 많이 받았다. 서촌조생 품종에서 신초의 37.5~58.3% 정도가 발근되었고 발근율은 2 krad 처리에서는 가장 낮았다. ${\gamma}$-선 조사선량이 높아지면 발근율과 뿌리의 발생수가 줄어들었다. 순화한 뒤 6주 동안 생장상에서 생육한 ${\gamma}$-선 조사 개체는 무처리 개체의 묘고가 6.0 cm인데 비해 2krad 처리개체는 평균 묘고는 2.6 cm에 불과하였다. 또한 발생한 가지의 수도 무처리에서는 1.0개인데 비해 2krad에서는 1.8 개로 많았다. 온실 생육시에서 ${\gamma}$-선 처리선량이 높았던 개체는 처리되지 않았거나 낮았던 개체에 비해 묘고가 작고 분지수가 많았으며, 생육상태도 부진하여 생육 중에 33%정도만 생존하고 나머지는 고사하였다.다.

  • PDF

칼라 CCD 영상을 이용한 고휘도 LED 전구의 빔 열화 분석 (Analysis of High Luminance LED Beam Degradation using Color CCD Image)

  • 조재완;최영수;이재철;구인수;홍석붕
    • 제어로봇시스템학회논문지
    • /
    • 제16권6호
    • /
    • pp.586-591
    • /
    • 2010
  • VLC (Visible Light Communication) is a wireless communication method using light that is visible to the human eye. It has a major advantage that it causes no interference to RF-based devices. This makes wireless communication possible in RF hazardous areas such as nuclear facilities. In order to apply VLC communication in harsh environment of nuclear power plant, the high luminance LEDs, which are key components of the VLC communication, have been gamma-ray irradiated at the dose rate of 4kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced color-center was formed in the LED housing cap made of transparent plastic or acryl material. The beam degradations of high luminance LEDs by high dose-rate gammaray irradiation are analyzed using color CCD image processing technology.