• Title/Summary/Keyword: Gamma Ray

Search Result 1,793, Processing Time 0.043 seconds

Detection Characteristics of Gamma-Irradiated Seeds by using PSL, TL, ESR and GC/MS (PSL, TL, ESR 및 GC/MS 분석을 통한 감마선 조사된 유지종실류의 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Kwak, Ji-Young;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Kim, Jae-I;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.2
    • /
    • pp.130-137
    • /
    • 2013
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL), electron spin resonance (ESR) and gas chromatography/mass spectrometry (GC/MS) methods for 5 seeds which are not allowed to be irradiated in Korea. All 5 seeds including evening primrose seed, safflower seed, rape seed, sunflower seed and flax seed were analyzed. Samples were irradiated at 1~10 kGy using a $^{60}Co$ gamma-ray irradiator. In PSL study, the photon counts of all the unirradiated samples showed negative (lower than 700). The photon counts of irradiated (1, 5, 10 kGy) samples showed positive (higher than 5,000). In TL analysis, results showed that it is possible to apply TL method to all foods containing minerals. In ESR measurements, the ESR signal (single-line) intensity of irradiated foods was higher than non-irradiated foods. The hydrocarbons 1,7-hexadecadiene ($C_{16:2}$) and 8-heptadecene ($C_{17:1}$) from oleic acid were detected only in the irradiated samples before and after the treatment at doses ${\geq}$ 1 kGy, but they were not detected in non-irradiated samples before and after treatment. These two hydrocarbons could be used as markers to identify irradiated safflower seed, rape seed, Sunflower seed and flax seed. And then, the hydrocarbons 1,7,10-hexadecatriene ($C_{16:3}$) and 6,9-heptadecadiene ($C_{17:2}$) from linoleic acid were detected in the evening primrose seed, safflower seed and sunflower seed. According to the results, PSL, TL and GC/MS methods were successfully applied to detect the irradiated foods. It is concluded that PSL, TL and GC/MS methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Identification of Active Agents for Reductive Dechlorination in Cement/Fe(II) Systems (시멘트와 Fe(II)을 이용한 환원성 탈염소화반응의 유효반응성분 규명)

  • Kim, Hong-Seok;Lee, Yu-Jung;Kim, Ha-Yan;Hwang, In-Seong
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.35-42
    • /
    • 2006
  • Experimental study was conducted to identify the active agent for reductive dechlorination of TCE in cement/Fe(II) systems. Several potential materials-hematite (${\alpha}-Fe_2O_3$), lepidocrocite (${\gamma}$-FeOOH), akaganeite (${\beta}$-FeOOH), ettringite ($Ca_6Al_2(SO_4)_3(OH)_{12}$)-that are cement components or parts of cement hydrates were tested if they could act as reducing agents by conducting TCE degradation experiments. From the initial degradation experiments, hematite was selected as a potential active agent. The pseudo-first-order degradation rate constant ($k\;=\;0.637\;day^{-1}$) for the system containing 200 mM Fe(II), hematite and CaO was close to that ($k\;=\;0.645\;day^{-1}$) obtained from the system containing cement and 200 mM Fe(II). CaO, which was originally added to simulate pH of the cement/Fe(II) system, was found to play an important role in degradation reactions. The reactivity of the hematite/CaO/Fe(II) system initially increased with increase of CaO dosage. However, the tendency declined in the higher CaO dosage region, implying a saturation type of behavior. The SEM analysis revealed that the hexagonal plane-shaped crystals were formed during the reaction with increasing degradation efficiency, which was brought about by increasing the CaO dosage. It was suspected that the crystals could be portlandite or green rust ($SO_4$) or Friedel's salt. The XRD analysis of the same sample identified the peaks of hematite, magnetite/maghemite, green rust ($SO_4$). Either instrumental analysis predicted the presence of the green rust ($SO_4$). Therefore, the green rust ($SO_4$) would potentially be a reactive agent for reductive dechlorination in cement/Fe(II) systems.

Distribution of natural radionuclide in the Geum river sediment (금강수계 퇴적물 중 천연 방사성핵종 분포 조사)

  • Seol, Bitna;Cho, Yoonhae;Min, Kyungok;Kim, Wansuk;Oh, Dayeon;Kil, Gibeom;Yang, Yunmo;Lee, Junbae;Kim, Byungik;Cheon, Seok
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.262-269
    • /
    • 2017
  • The concentration of natural radioactivity in the sediment of the Geum River was investigated. The river and lake sediment samples were collected at 23 points during September to November, 2015 and March to April, 2015, respectively. The gamma-rays emitted from the $^{226}Ra$ and $^{232}Th$ decay series and $^{40}K$ were measured with a high purity germanium (HPGe) gamma detector. The average radioactivity concentrations of the $^{226}Ra$, $^{232}Th$ decay series and $^{40}K$ for the river sediment was found to be $15.6{\pm}0.6$, $33.8{\pm}1.2$, $789.8{\pm}26.0Bq/kg$, respectively, while for the lake sediment, the concentrations were $17.1{\pm}0.5$, $37.8{\pm}1.1$, $269.4{\pm}9.6Bq/kg$, respectively. Spearman's correlation was conducted to compare the radioactivity concentration and properties of the sediment. The radioactivity concentration of the $^{232}Th$ decay series showed a negative correlation with the particle size of the sediment, and was measured to be higher than the $^{226}Ra$ decay series according to mobility of the radionuclides. The radioactivity concentration of $^{40}K$ showed a negative correlation with organic matter content. The concentration of $^{40}K$ in the lake sediment was lower than that in the river sediment.

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

Growth of CdSe thin films using Hot Wall Epitaxy method and their photoelectrical characteristics (HWE방법에 의한 CdSe 박막 성장과 광전기적 특성)

  • Hong, K.J.;Lee, K.K.;Lee, S.Y.;You, S.H.;Shin, Y.J.;Suh, S.S.;Jeong, J.W.;Jeong, K.A.;Shin, Y.J.;Jeong, T.S.;Kim, T.S.;Moon, J.D.;Kim, H.S.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.328-336
    • /
    • 1997
  • The CdSe thin films were grown on the Si(100) wafers by a hot wall epitaxy method (HWE). The source and substrate temperature are $600^{\circ}C$ and $430^{\circ}C$ respectively. The crystalline structure of epilayers was investigated by double crystal X-ray diffraction(DCXD). Hall effect on the sample was measured by the van der Pauw method and studied on the carrier density and mobility dependence on temperature. From Hall data, the mobility was increased in the temperature range 30K to 150K by impurity scattering and decreased in the temperature range 150k to 293k by the lattice scattering. In order to explore the applicability as a photoconductive cell, we measured the sensitivity(${\gamma}$), the ratio of photocurrent to darkcurrent(pc/dc), maximum allowable power dissipation(MAPD), spectral response and response time. The results indicated that the photoconductive characteristic were the best for the samples annealed in Cu vapor compare with in Cd, Se, air and vacuum vapour. Then we obtained the sensitivity of 0.99, the value of pc/dc of $1.39{\times}10^{7}$, the MAPD of 335mW, and the rise and decay time of 10ms and 9.5ms, respectively.

  • PDF

Removal Characteristic of Arsenic by Sand Media Coated with both Iron-oxide and Manganese-oxide (산화철 및 산화망간이 동시에 코팅된 모래 매질을 이용한 비소오염 제거특성 연구)

  • Kim, Byeong-Kwon;Min, Sang-Yoon;Chang, Yoon-Young;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.473-482
    • /
    • 2009
  • In this study, iron and manganese coated sand (IMCS) was prepared by mixing Joomoonjin sand with solutions having different molar ratio of manganese ($Mn^{2+}$) and iron ($Fe^{3+}$). Mineral type of IMCS was analyzed by X-ray diffraction spectroscopy. Removal efficiency of arsenic through As(III) oxidation and As(V) adsorption by IMCS having different ratio of Mn/Fe was evaluated. The coated amount of total Mn and Fe on all IMCS samples was less than that on sand coated with iron-oxide alone (ICS) or manganese-oxide alone (MCS). The mineral type of the manganese oxide on MCS and iron oxides on ICS were identified as ${\gamma}-MnO_2$ and mixture of goethite and magnetite, respectively. The same mineral type was appeared on IMCS. Removed amount As(V) by IMCS was greatly affected by the content of Fe rather than by the content of Mn. Adsorption of As(V) by IMCS was little affected by the presence of monovalent and divalent electrolytes. However a greatly reduced As(V) adsorption as observed in the presence of trivalent electrolyte such as $PO_4\;^{3-}$. As(III) oxidation efficiency by MCS in the presence of NaCl or $NaNO_3$ was two times greater than that in the presence of $PO_4\;^{3-}$. Meanwhile a greater As(III) oxidation efficiency was observed by IMCS in the presence of $PO_4\;^{3-}$. This was explained by the competitive adsorption between phosphate and arsenate on the surface of IMCS.

The Role of Radiotherapy in the Treatment of Extrahepatic Bile Duct Carcinoma (간외담도종양에서 방사선치료의 역할)

  • Shin Hyun Soo;Kim Gwi Eon;Lee Hyung Sik;Suh Chang Ok;Loh John JK;Lee Jong Tae
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.253-263
    • /
    • 1991
  • Twenty-seven patients with unresectable extrahepatic bile duct carcinoma (n=21) or with microscopic evidence of tumor rest after aggressive surgery for extrahepatic bile duct carcinoma (n=6) between 1985 and 1990 were given radiotherapy consisting intentionally external radiotherapy and/or intraluminal therapy using Gamma-Med 12i (192-Ir) high dose rate (HDR) remote control afterloading system following bile drainage procedures and Gianturco stent insertion. The objectives of this study has been to assess the feasibility and effects on survival of a combination of external radiotherapy and brachytherapy with which we hope to achieve optimal loco-regional control for patients with unresectable extrahepatic bile duct tumors. Sixteen patients were men and eleven were women, and the mean age was 58 years (34-70). 10MV X-ray was used for radiation therapy, with the total dose ranging from 45 Gy to 55 Gy, and intraluminal brachytherapy performed after external radiotherapy, with the dose of total 15 Gy. The minimum follow up was 12 months. Failure were predominantly local-regional, without distant failure. Median survival was 10 months; 2-year actuarial survival rates was $21\%$. Median survival for common hepatic duct (CHD) cancer was 9 months; for common bile duct (CBD) cancer, was 16 months. And median survival for incomplete surgery/external radiotherapy group and external/intraluminal radiotherapy group was 10 months; for external radiotherapy alone group, was 6 months. Use of chemotherapy and/or hyperthermia were not affected in survival. Therefore, our result is that the survival rates in the group of external/intraluminal radiotherapy were comparable with ones in the group of incomplete resection/external radiotherapy, and so we believe that the aggressive local and regional radiotherapy can improve the quality of life and the survival length.

  • PDF

Significance of Apoptotic Cell Death after $\gamma-Irradiation$ (방사선 조사에 의한 세포사에 있어서 세포고사의 의미)

  • Wu H.G.;Kim I.H.
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.252-258
    • /
    • 2001
  • Purpose : The objectives of this study are to investigate the significance of apoptotic death compared to total cell death after $\gamma-ray$ irradiation in human H&N cancer cell lines and to find out correlation between apoptosis and radiation sensitivity. Materials and method : Head and neck cancer cell lines (PCI-1, PCI-13, and SNU-1066), leukemia cell line (CCRF-CEM), and fibroblast cell line (LM217) as a normal control were used for this study. Cells were irradiated using Cs-137 animal experiment irradiator. Total cell death was measured by clonogenic assay. Annexin-V staining was used to detect the fraction of apoptotic death. Results : Surviving fraction at 2 Gy (SF2) were 0.741, 0.544, 0.313, 0.302, and 0.100 for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217 cell lines, respectively. Apoptosis was detected in all cell lines. Apoptotic index reached peak value at 72 hours after irradiation in head and neck cancer cell lines, and that was at 24 hours in CCRF-CEM and LM217. Total cell death increased exponentially with increasing radiation dose from 0 Gy to 8 Gy, but the change was minimal in apoptotic index. Apoptotic fractions at 2 Gy were $46\%,\;48\%,\;46\%,\;24\%,\;and\;19\%$ and at 6 Gy were $20\%,\;33\%,\;35\%,\;17\%,\;and\;20\%$ for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217, respectively. The radioresistant cell lines showed more higher apoptotic fraction at 2 Gy, but there was not such correlation at 6 Gy. Conclusion : All cell lines used in this study showed apoptosis after irradiation, but time course of apoptosis was different from that of leukemia cell line and normal fibroblast cell line. Reproductive cell death was more important mode of cell death than apoptotic death in all cell lines used in this study. But there was correlation between apoptotic fraction and radiation sensitivity at 2 Gy.

  • PDF

Detection Characteristics of PSL and TL Methods in Spices Irradiated with Different Radiation Sources (조사선원에 따른 향신료의 PSL과 TL 검지 특성)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Kim, Jung-Ki;Hwang, Cho-Rong;Lee, Jae-Hwang;Park, Yong-Chjun;Kim, Jae-I;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • The detection characteristics of irradiated spices were investigated depending on radiation sources and doses by photostimulated luminescence (PSL) and Thermoluminescence (TL). 6 kinds of spices (turmeric, onion powder, red pepper, basil, parsley, black pepper) were irradiated at 0 to 10 kGy under ambient conditions by both a $^{60}Co$ gamma irradiator and an electron beam (EB) accelerator, respectively. The PSL analysis showed negative results for non-irradiated spices, while irradiated spices gave intermediate and positive value, which presented the limited potential of PSL technique. In TL measurement, TL glow curves on non-irradiated samples appeared at about $300^{\circ}C$ with low intensity. All irradiated samples were easily distinguishable through radiation-specific strong TL glow curves with maximum peak in range of $150{\sim}200^{\circ}C$. TL ratio ($TL_1/TL_2$) obtained by a re-irradiation step could verify the detection result of $TL_1$ glow curves, showing ratios lower than 0.1 in the non-irradiated sample and higher than 0.1 in irradiated ones. Therefore, in PSL measurement, the identification of irradiated spices showed more clear results in electron beam irradiated samples. TL analysis showed obvious difference between non-irradiated and irradiated samples in gamma ray and electron beam irradiated samples.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF