• Title/Summary/Keyword: Gamma Index

Search Result 455, Processing Time 0.028 seconds

Investigation of the Jets of the Blazar 3C 279 with Korean VLBI Network (KVN) 22-129 GHz Observations

  • Yoo, Sungmin;Lee, Sang-Sung;Kim, Sang-Hyun;An, Hongjun
    • Journal of Astronomy and Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.193-202
    • /
    • 2021
  • We present analysis results of Korean VLBI Network (KVN) four-band data for the highly variable blazar 3C 279. We measured the 22, 43, 86, and 129 GHz flux densities and spectral indices of the source using contemporaneous data taken over 5.6 years. We used the discrete correlation function to investigate correlations between the radio emission properties and those measured in the optical (2 × 1014 - 1.5 × 1015 Hz), X-ray (0.3-10 keV), and gamma-ray (0.1-300 GeV) bands. We found a significant correlation between the radio spectral index and gamma-ray flux without a time delay and interpreted the correlation using an extended jet scenario for blazar emission.

Restoration of Ghost Imaging in Atmospheric Turbulence Based on Deep Learning

  • Chenzhe Jiang;Banglian Xu;Leihong Zhang;Dawei Zhang
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.655-664
    • /
    • 2023
  • Ghost imaging (GI) technology is developing rapidly, but there are inevitably some limitations such as the influence of atmospheric turbulence. In this paper, we study a ghost imaging system in atmospheric turbulence and use a gamma-gamma (GG) model to simulate the medium to strong range of turbulence distribution. With a compressed sensing (CS) algorithm and generative adversarial network (GAN), the image can be restored well. We analyze the performance of correlation imaging, the influence of atmospheric turbulence and the restoration algorithm's effects. The restored image's peak signal-to-noise ratio (PSNR) and structural similarity index map (SSIM) increased to 21.9 dB and 0.67 dB, respectively. This proves that deep learning (DL) methods can restore a distorted image well, and it has specific significance for computational imaging in noisy and fuzzy environments.

A Baseline Study on the Choice of Optimal Screening Test Items among Workers with Abnormal Liver Function Tests on Workers' Periodic Health Examination (근로자 건강진단시 간기능 이상자의 정밀검사항목 개선을 위한 조사연구)

  • Cheong, Hae-Kwan;Lim, Hyun-Sul;Kim, Gyu-Hoi
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.4 s.48
    • /
    • pp.747-761
    • /
    • 1994
  • Workers' periodic health examination is the main tools used to manage the health problems of most workers in Korea. The most common health problem found in workers' periodic health examination is liver disorder. Liver disorder is also one of the most common health problems in general population and one of the leading causes of mortality in adult population. Regulation proposed by government (No. 207, Ministry of Labor, 1992) defines the criteria for selection of workers with the liver dysfunction for further evaluative examination and the examination items used for diagnosis of the workers with liver dysfunction. This study was designed to evaluate the proficiency of each examination items presently defined in Regulation and propose the optimal examination items for detection of the liver disorders found by workers' periodic health examination. Study subjects are 186 workers with abnormal liver function tests in screening examination of workers' periodic health examination. Questionnaire survey including past history of liver disorder, drinking history, height and weight was done. Physical examination by physician, routine test items defined by Regulation (SGOT, SGPT, $\gamma$-GTP, protein, albumin, total and direct bilirubin, alkaline phosphatase, $\alpha$-feto protein, HBsAg and anti-HBs), anti-HCV antibody test and liver ultrasonography were done. Results are as follows; 1. Result of evaluative examination utilizing only the items defined in Regulation was; There were 75 workers with suspected live. disorder(40.3%), 63 with no liver dysfunction (33.9%), 13 with suspected hepatitis B(7.0%), 10 workers with hepatitis B(5.4%), 10 workers with hepatitis B carrier state(5.4%), 10 with alcoholic liver disorders(5.4%), 5 with fatty liver(2.7%). When alternative diagnostic criteria applying additional examination items (drinking history, body mass index, anti-HCV antibody and ultrasonography) diagnosability of liver disorder was increased. When all four items were included, final results were; 23 workers (17.8%) with hepatitis B (10 carriers, 13 suspects and 10 hepatitis B), 10 (5.4%) with hepatitis C(4 carriers, 5 suspects and 1 hepatitis C), 13(7.0%) with alcoholic liver disorder, 45(24.2%) with fatty liver (40 suspects, 5 fatty liver), 410%) with suspected liver disorders and 44 (23.7%) with normal liver. 2. Of examination items defined by Regulation, only SGOT, SGPT, $\gamma$-GTP and HBsAg were significantly different in abnormal rate and mean value, and all other laboratory findings did not showed significant difference between two groups. Drinking history, body mass index and anti-HCV antibody test which are the items that authors included in this study, also showed significant difference between two groups. Utilization of body mass index (BMI) for abnormal liver function group in diagnosis of fatty liver had high specificity (97.6%) but sensitivity (22.3%) was low. Therefore we suggest that SGOT, SGPT, $\gamma$-GTP, HBsAg, alcohol drinking history, BMI and anti-HCV Ab were useful for diagnosis of liver disorders among worker's periodic health examination.

  • PDF

Discrepancies between Calculated and Delivered Dose Distributions of Respiratory Gated IMRT Fields according to the Target Motion Ranges for Lung and Liver Cancer Patients (호흡연동방사선치료시 폐암과 간암환자의 병소 움직임 크기에 따른 선량분포 차이 분석)

  • Kim, Youngkuk;Lim, Sangwook;Choi, Ji Hoon;Ma, Sun Young;Jeung, Tae Sig;Ro, Tae Ik
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.242-247
    • /
    • 2014
  • To see the discrepancies between the calculated and the delivered dose distribution of IMRT fields for respiratory-induced moving target according to the motion ranges. Four IMRT plans in which there are five fields, for lung and liver patients were selected. The gantry angles were set to $0^{\circ}$ for every field and recalculated using TPS (Eclipse Ver 8.1, Varian Medical Systems, Inc., USA). The ion-chamber array detector (MatriXX, IBA Dosimetry, Germany) was placed on the respiratory simulating platform and made it to move with ranges of 1, 2, and 3 cm, respectively. The IMRT fields were delivered to the detector with 30~70% gating windows. The comparison was performed by gamma index with tolerance of 3 mm and 3%. The average pass rate was 98.63% when there's no motion. When 1.0, 2.0, 3.0 cm motion ranges were simulated, the average pass rate were 98.59%, 97.82%, and 95.84%, respectively. Therefore, ITV margin should be increased or gating windows should be decreased for targets with large motion ranges.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

Radioprotective Effect of Quercetin Post-Treatment against γ-Irradiation-Induced Hepatocellular and Hematopoiectic System Damage in Mice (감마선 조사로 유도된 간세포와 조혈계 손상 마우스에서 퀘르세틴 투여 후의 방사선방호 효과)

  • Kang, Jung Ae;Yoon, Seon Hye;Rho, Jong Kook;Choi, Dae Seong;Jang, Beom-Su;Park, Sang Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.7
    • /
    • pp.970-974
    • /
    • 2015
  • This study was designed to evaluate the therapeutic effect of quercetin against radiation-induced hepatocellular and hematopoiectic damage in BALB/c mice. Mice were exposed to 6 Gy of ${\gamma}$-radiation and orally administered quercetin (25, 50 mg/kg b.w.) for 7 consecutive days. ${\gamma}$-Irradiation caused marked elevation of serum aspartate aminotransferase and alanine aminotransferase, levels as well as reduction of spleen index, thymus index, and the number of white blood cells. In addition, ${\gamma}$-irradiation induced significant elevation of lipid peroxidation as well as reduction of antioxidant enzyme activities, including superoxide dismutase, catalase, and glutathione peroxidase. However, post-treatment with quercetin resulted in a significant recovery of all of these parameters. These results suggest that quercetin acts as a potent radioprotector against irradiation-induced cellular damage in mice.

Clinical Usefulness of Ultrasonography in the Diagnosis of Fatty Liver (지방간 진단에 있어 초음파 검사의 임상적 유용성 연구)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.349-357
    • /
    • 2019
  • The purpose of this study was to evaluate the clinical significance of ultrasonographic classification of fatty liver in three grades. From June 2018 to April 2019, 1047 patients (818 males and 229 females) diagnosed as fatty liver among 3607 patients who underwent abdominal ultrasonography at Busan screening center. Ultrasonography was classified into three grades: Grade I (mild fatty liver), Grade II (moderate fatty liver), and Grade III (severe fatty liver) according to the degree of parenchyma texture, acoustic attenuation, Obesity index, hematological test, and metabolic syndrome. The average age of men in each sex increased with the increase of the fatty liver. Body mass index (BMI) and waist circumference were significantly increased in both men and women (p=.000). hematological analysis showed that AST, ALT, ${\gamma}-GTP$, TG, fasting blood sugar, and glycated hemoglobin were significantly different from each other (p<.05). In women, ALT, ${\gamma}-GTP$ and TG showed a significant difference with increasing fatty liver (p<.05). The prevalence of metabolic syndrome was significantly increased in both sexes as the grade of fatty liver increased (p=.000). Based on the results of this study, it is suggested that the use of ultrasound - guided fatty liver according to severity may be useful for the treatment and follow - up of fatty liver if the liver grade is divided in consideration of hematological variables and metabolic syndrome.

Empirical Analysis of DEA models Validity for R&D Project Performance Evaluation : Focusing on Rank Correlation with Normalization Index (R&D 프로젝트 성과평가를 위한 DEA모형의 타당성 실증분석 : 정규화지표와의 순위상관을 중심으로)

  • Park, Sung-Min
    • IE interfaces
    • /
    • v.24 no.4
    • /
    • pp.314-322
    • /
    • 2011
  • This study analyzes a relationship between Data Envelopment Analysis(DEA) efficiency scores and a normalization index in order to examine the validity of DEA models. A normalization index concerned in this study is 'sales per R&D project fund' which is regarded as a crucial R&D project performance evaluation index in practice. For this correlation analysis, three distinct DEA models are selected such as DEA basic model, DEA/AR-I revised model(i.e. DEA basic model with Acceptance Region Type I constraints) and Super-Efficiency(SE) model. Especially, SE model is adopted where efficient R&D projects(i.e. Decision Making Units, DMU's) with DEA efficiency score of unity from DEA basic model can be further differentiated in ranks. Considering the non-normality and outliers, two rank correlation coefficients such as Spearman's ${\rho}_s$ and Kendall's ${\tau}_B$ are investigated in addition to Pearson's ${\gamma}$. With an up-to-date empirical massive dataset of n = 482 R&D projects associated with R&D Loan Program of Korea Information Communication Promotion Fund in the year of 2011, statistically significant (+) correlations are verified between the normalization index and every model's DEA efficiency scores with all three correlation coefficients. Especially, the congruence verified in this empirical analysis can be a useful reference for enhancing the practitioner's acceptability onto DEA efficiency scores as a real-world R&D project performance evaluation index.

Investigation of an Acceptable Hemolysis Index Using Re-collected Samples (재채혈된 검체를 이용한 허용 Hemolysis Index에 대한 연구)

  • Hong Bum KIM;Dong Il WON;Kyoung Ae SON;Jin Man KIM;Yu Jin WOO
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.1
    • /
    • pp.32-42
    • /
    • 2024
  • This study compared the results of hemolyzed samples and re-collected samples to investigate a hemolysis influence and an acceptable hemolysis index (HI). Before and after hemolysis, alkaline phosphatase (ALP), aspartate aminotransferase (AST), alanine aminotransferase (ALT), amylase (Amy), direct bilirubin (D-bil), total bilirubin (T-bil), creatine phosphokinase (CK), gamma glutamyl transferase (GGT), iron, potassium (K), lactate dehydrogenase (LDH), magnesium (Mg), phosphorus (Phos), total protein (TP), and uric acid (UA) showed significant results in the paired t-test. LDH, K, iron, AST, CK, GGT, TP, Amy and Phos had a high correlation between the degree of hemolysis and the results of samples. When comparing Roche's cut-off HI with HIQChigh obtained using quality control (QC) high standard deviation (SD), AST, D-bil, CK, and LDH were similar, but Amy, GGT, K, iron, Phos, and TP were lower than the cut-off HI of Roche, while ALP and ALT were higher. Some analytes which showed no significant results in the paired t-test, were found to have significant results in HI>200. Hence, it is suggested that the hemolyzed sample should be rejected if HI>200. Based on this study that some analytes were affected when HI<100, we recommend to set the standard of hemolysis starting from HI>50.

Multivariate statistical study on naturally occurring radioactive materials and radiation hazards in lakes around a Chinese petroleum industrial area

  • Yan Shi;Junfeng Zhao;Baiyao Ding;Yue Zhang;Zhigang Li;Mohsen M.M.Ali;Tuya Siqin;Hongtao Zhao;Yongjun Liu;Weiguo Jiang;Peng Wu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2182-2189
    • /
    • 2024
  • The high-purity germanium gamma-ray spectrometer was used to measure the radioisotope in surface water of lakes in a Chinee petroleum industrial area. 92 samples were collected from surface water of three lakes. Activity concentrations of 232Th, 226Ra and 40K in three lakes were measured, distributed in the range of 101.8-209.4, 192.1-224.9 and 335.0-548.9 mBq/L, respectively. Results were all within the limits of WHO and China. Potential environmental and health risks were assessed by calculating some radiation hazard indicators, radium equivalent index, annual effective dose, excess lifetime cancer risk, absorbed dose rate, external hazard index, internal hazard index, annual gonadal dose equivalent, activity utilization index and representative gamma index, which ranged 0.38-0.54 Bq/L, 0.06-0.08 mSv/y, 0.23 × 10-3-0.31 × 10-3, 0.17-0.24 nGy/h, 1.01 × 10-3-1.46 × 10-3, 1.55 × 10-3-2.02 × 10-3, 1.16-1.66 μSv/y, 3.13 × 10-3-4.45 × 10-3 and 2.60 × 10-3-3.77 × 10-3. The results were all at acceptable levels, meaning no impact on human health. The relationship between the electrical conductivity of surface water and the activity concentration of 232Th, 226Ra and 40K was evaluated. The electrical conductivity value was 0.241-0.369 mS/cm, showing a significant correlation coefficient between 226Ra and 40K and electrical conductivity. Multivariate statistical methods were used to determine the relationship between the activity concentrations of 232Th, 226Ra, and 40K, radiation hazard indicators and electrical conductivity.