암환자에게 다빈도로 활용되는 한약제제 10종에 대한 요오드의 함량 분석 (Determination of Iodine Contents in Ten kinds of Frequently used Oriental Herb Medicinal Products for Cancer Patient)

  • 이창희;최정은;김선하;정용삼;문종화;유화승
    • 대한암한의학회지
    • /
    • 제16권1호
    • /
    • pp.41-53
    • /
    • 2011
  • Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.

Hot Wall Epitaxy(HWE)법에 의한 ZnAl2Se4 단결정 박막 성장과 가전자대 갈라짐에 대한 광전류 연구 (Growth and Electrical Properties of ZnAl2Se4 Single Crystal Thin Film by Hot Wall Epitaxy)

  • 박향숙;방진주;이기정;강종욱;홍광준
    • 한국재료학회지
    • /
    • 제23권12호
    • /
    • pp.714-721
    • /
    • 2013
  • A stoichiometric mixture of evaporating materials for $ZnAl_2Se_4$ single-crystal thin films was prepared in a horizontal electric furnace. These $ZnAl_2Se_4$ polycrystals had a defect chalcopyrite structure, and its lattice constants were $a_0=5.5563{\AA}$ and $c_0=10.8897{\AA}$.To obtain a single-crystal thin film, mixed $ZnAl_2Se_4$ crystal was deposited on the thoroughly etched semi-insulating GaAs(100) substrate by a hot wall epitaxy (HWE) system. The source and the substrate temperatures were $620^{\circ}C$ and $400^{\circ}C$, respectively. The crystalline structure of the single-crystal thin film was investigated by using a double crystal X-ray rocking curve and X-ray diffraction ${\omega}-2{\theta}$ scans. The carrier density and mobility of the $ZnAl_2Se_4$ single-crystal thin film were $8.23{\times}10^{16}cm^{-3}$ and $287m^2/vs$ at 293 K, respectively. To identify the band gap energy, the optical absorption spectra of the $ZnAl_2Se_4$ single-crystal thin film was investigated in the temperature region of 10-293 K. The temperature dependence of the direct optical energy gap is well presented by Varshni's relation: $E_g(T)=E_g(0)-({\alpha}T^2/T+{\beta})$. The constants of Varshni's equation had the values of $E_g(0)=3.5269eV$, ${\alpha}=2.03{\times}10^{-3}eV/K$ and ${\beta}=501.9K$ for the $ZnAl_2Se_4$ single-crystal thin film. The crystal field and the spin-orbit splitting energies for the valence band of the $ZnAl_2Se_4$ were estimated to be 109.5 meV and 124.6 meV, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_5$ states of the valence band of the $ZnAl_2Se_4/GaAs$ epilayer. The three photocurrent peaks observed at 10 K are ascribed to the $A_1$-, $B_1$-exciton for n = 1 and $C_{21}$-exciton peaks for n = 21.

장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析) (Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle)

  • 이태영;하정우;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제9권2호
    • /
    • pp.90-96
    • /
    • 1984
  • 장주기핵연료(長週期核燃料) 노심기법(爐心技法)에 의한 사용후핵연료(使用後核燃料)가 기존(旣存) 사용후핵연료저장시설(使用後核燃料貯藏施設)의 설계변경(設計變更)없이 동(同) 시설(施設)에 수용(受容) 가능(可能)한지를 결정(決定)하기 위하여 저장시설(貯藏施設)에서의 예상(豫想) 방사선피폭선량률(放射線被曝線量率) DLC-23/CASK (22n, 18g) 단면적(斷面積)자료(資料)와 ANISN-W 전산(電算)코드로 계산(計算)하여 설계기준치(設計基準値)와 비교(比較) 검토(檢討)하였다. 사용후핵연료내(使用後核燃料內)의 방사능량(放射能量) 및 감마선스펙트럼은 핵연료교체(核燃料交替)모델에 따라 ORIGEN 전산(電算)코드로 계산(計算)하였다. 방사선량률(放射線量率)의 계산(計算)에 있어서 저장조(貯藏槽)의 기하학적(幾何學的) 모델은 무한평판모형(無限平板模型)이며 저장(貯藏)된 사용후핵연료(使用後核燃料)의 구성물질(構成物質)과 방사선원(放射線源)은 핵연료집합체내(核燃料集合體內)에 균일(均一)하게 분포(分布)되었다고 가정(假定)하였다. 사용후핵연료저장조(使用後核燃料貯藏槽)에 저장(貯藏)된 핵연료집합체(核燃料集合體) 및 저장용수중(貯藏用水中) 방사성핵종(放射性核種)에 의한 방사선량률(放射線量率)의 계산(計算) 결과(結果)는 정상(正常) 및 사고수면시(事故水面時) 계산(計算)된 방사선량률(放射線量率)이 설계기준치(設計基準値)를 만족(滿足)시켜주는 것으로 나타났다.

  • PDF

Study on Dose Rate on the Surface of Cask Packed with Activated Cut-off Pieces from Decommissioned Nuclear Power Plant

  • Park, Kwang Soo;Kim, Hae Woong;Sohn, Hee Dong;Kim, Nam Kyun;Lee, Chung Kyu;Lee, Yun;Lee, Ji Hoon;Hwang, Young Hwan;Lee, Mi Hyun;Lee, Dong Kyu;Jung, Duk Woon
    • Journal of Radiation Protection and Research
    • /
    • 제45권4호
    • /
    • pp.178-186
    • /
    • 2020
  • Background: Reactor pressure vessel (RV) with internals (RVI) are activated structures by neutron irradiation and volume contaminated wastes. Thus, to develop safe and optimized disposal plan for them at a disposal site, it is important to perform exact activation calculation and evaluate the dose rate on the surface of casks which contain cut-off pieces. Materials and Methods: RV and RVI are subjected to neutron activation calculation via Monte Carlo methodology with MCNP6 and ORIGEN-S program-neutron flux, isotopic specific activity, and gamma spectrum calculation on each component of RV and RVI, and dose rate evaluation with MCNP6. Results and Discussion: Through neutron activation analysis, dose rate is evaluated for the casks containing cut-off pieces produced from decommissioned RV and RVI. For RV cut-off ones, the highest value of dose rate on the surface of cask is 6.97 × 10-1 mSv/hr and 2 m from it is 3.03 × 10-2 mSv/hr. For RVI cut-off ones, on the surface of it is 0.166 × 10-1 mSv/hr and 2 m from it is 1.04 × 10-1 mSv/hr. Dose rates for various RV and RVI cut-off pieces distributed lower than the limit except the one of 2 m from the cask surface of RVI. It needs to adjust contents in cask which carries highly radioactive components in order to decrease thickness of cask. Conclusion: Two types of casks are considered in this paper: box type for very-low-level waste (VLLW) as well as low-level waste (LLW) and cylinder type for intermediate-level waste (ILW). The results will contribute to the development of optimal loading plans for RV and RVI cut-off pieces during the decommissioning of nuclear power plant that can be used to prepare radioactive waste disposal plans for the different types of wastes-ILW, LLW, and VLLW.

환경토양에서 몰리브도인산 암모늄을 이용한 세슘 동위원소 평가방법 (Cesium Radioisotope Measurement Method for Environmental Soil by Ammonium Molybdophosphate)

  • 최영훈;서양곤
    • 청정기술
    • /
    • 제22권2호
    • /
    • pp.122-131
    • /
    • 2016
  • 세슘 동위원소, 134Cs와 137Cs는 대기 핵실험 및 원자력발전소의 배출물로부터 기인하는 인공방사성 핵종 연구에 매우 중요하다. 본 연구에서는 최소검출방사능(minimum detection activity, MDA)을 낮추기 위해 137Cs 및 화학적, 환경적 거동이 동일한 134Cs를 이용하여 환경측정실험실 절차서에 따른 일반적인 환경방사능 분석을 수행하였다. 원자력발전소 주변 고산지대 환경토양을 채취하였고, 세슘 동위원소를 화학적으로 추출·농축하기 위한 방법으로 세슘동위원소와 흡착특성이 높은 Ammonium Molybdophosphate (AMP) 공침법을 토양 전처리 과정에 도입하였다. 방사능 농도는 감마선 분광광도법을 이용하여 분석하였다. 감마 에너지 스펙트럼에서 40K 방사능 농도가 증가함에 따라 134Cs 및 137Cs의 MDA가 증가하였다. 따라서 토양으로부터 자연방사성 핵종이 제거된다면 세슘의 MDA가 줄어들 것이고, 환경토양에서 137Cs의 농도를 효과적으로 측정할 수 있다. 한국원자력안전기술원의 표준 토양 실험에서는 40K의 방사능 농도가 평균 84% 이상 제거되었고, 134Cs의 MDA는 2배 줄어들었다. 137Cs의 방사능 농도는 82% 이상 회수되었다. 한편 환경토양을 이용한 시료에서는 AMP 공침법이 직접법에 비해 40K는 최대 180배 제거되었고, 또한 134Cs의 MDA는 5배 감소하였다. 137Cs의 회수율은 54.54%에서 70.26%를 나타내었다. MDA와 회수율을 고려할 때 AMP 공침법은 매우 낮은 농도의 세슘분석에 효과적이다.

감마선분광분석(線分光分析) 및 열형광검출법(熱螢光檢出法)에 의한 자연방사선(自然放射線)의 선량측정연구(線量測定硏究) (Assessment of Natural Radiation Exposure by Means of Gamma-Ray Spectrometry and Thermoluminescence Dosimetry)

  • 전재식;오희필;최철규;오헌진;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제10권2호
    • /
    • pp.96-108
    • /
    • 1985
  • 감마선분광분석 및 열형광선량측정법에 의한 자연환경방사선의 선량해석에 관한 연구를 1984년 10월부터 약 1년간에 걸쳐 충남대학교 대덕캠퍼스내의 1만 $m^2$ 규모의 평면개활지에서 수행하였다. 이 연구에서 사용한 검출기는 3'${\phi}{\times}$3' NaI(T1) 섬광계수기(閃光計數器)와 plastic 에 밀봉하여 금속판에 압착 처리한 chip 과 Teflon-disk 로된 2종의 LiF TLD 였다. 실측실험으로는 3회에 걸친 24시간 cycle의 in-situ spectrometry 와 2회의 3개월 cycle 과 1회의 1개월 cycle에 걸친 TLD field dosimetry를 수행하였다. 측정한 모든 spectrum은 G(E)연산자법에 의하여 조사선량율(照射線量率)로 환산하였고 그 결과로부터 환경 방사선의 지설성분(地設成分)을 산출하였다. 결과(結果)에 의하면 spectrometry로 구한 조사선량율이 평균 $(10.54{\pm}2.96){\mu}R/hr$, TLD chip으로 측정해석한 값은 $(12.0{\pm}3.4){\mu}R/hr$, disk에서 얻은 값이 $(11.0{\pm}3.6){\mu}R/hr$로 오차범위 안에서 매우 좋은 일치를 보이고 있다. 그러나 감마선분광분석에 의한 자연방사선의 일변화(日變化)에는 가끔 심한동요가 관측되었다. 정확한 환경방사선량해석을 위하여 감마선분광분석과 TLD의 적절한 동시 배합사용이 바람직 하며, 보다 고감도의 TLD에 관한 연구와 국제비교등을 통한 선량평가의 정도향상(精度向上)을 위한 보다 깊이 있는 연구가 필요하다는 결론(結論)에 도달하였다.

  • PDF

중성자 모니터링을 위한 전도성 10B 박막 개발 (The development of conductive 10B thin film for neutron monitoring)

  • 임창휘;김종열;이수현;정용주;최영현;백철하;문명국
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.199-205
    • /
    • 2014
  • 중성자 검출분야에서$^3He$는 높은 중성자 검출효율 때문에 아주 많이 사용되고 있다. 하지만 2009년 초반부터 발생하고 있는 전세계적인 $^3He$의 품귀현상으로 인하여 가격이 급등하고 수급이 어려워졌기 때문에 대체 중성자 검출물질에 대한 필요성이 높아졌다. 그러므로 중성자 검출물질로 사용될 수는 있지만 $^3He$에 비해 반응효율이 낮아 중성자 검출용으로 주로 사용되지 않던 물질들을 사용하여 검출기를 제작하는 연구가 다시 활발하게 진행되고 있다. $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$ 등과 같은 $^3He$ 대체 물질들 중 하나인 $^{10}B$은 손쉬운 감마선 구별, 무독성, 낮은 가격 등과 같은 여러 장점으로 인하여 여러 연구그룹에서 연구되고 있다. $^{10}B$ 박막을 이용한 중성자 검출은 중성자와 반응하여 발생되는 2차 방사선을 측정하여 간접적으로 중성자를 측정하는 검출기법이다. 반응을 통해 생성된 알파입자의 비정은 고체 내에서 아주 짧기 때문에 $^{10}B$ 층은 박막 형태로 얇게 제작해야 한다. 그러므로 중성자와 박막의 반응을 통해 발생되는 알파입자의 검출효율을 증가시키기 위해서는 $^{10}B$ 박막의 두께를 얇게 제작하는 것이 중요하다. 하지만 박막의 두께를 얇게 제작하는 것은 중성자와 반응하여 생성되는 알파입자의 수집효율을 증가시키는 장점이 있지만 또한 중성자와 반응할 단면적을 감소시키는 단점이 있다. 본 논문에서는 리튬이온전지에 사용되는 초박막 극판 제조 기술을 이용하여 중성자 검출을 위한 대략 $60{\mu}m$ 두께의 얇은 $^{10}B$ 박막을 제작하였다. 그리고 전도성, 분포, 점착력, 유연성와 같은 간단한 물리적 실험을 통해 제작된 $^{10}B$ 박막의 물성을 확인하였다. 또한, 제작된 $^{10}B$ 박막을 사용하여 중성자 모니터링을 위한 비례계수기 제작하고 이를 이용하여 한국원자력연구원의 중성자 조사시설의 중성자 파고 스펙트럼을 측정하였다. 또한, 중성자 검출효율을 증가시킬 수 있는 방법 중 하나인 다층 박막을 이용한 중성자 측정 방법을 이용하여 박막 층수에 따른 중성자 검출효율의 변화를 몬테칼로 전산모사 기법을 이용하여 계산하였고 실험을 통해 박막층의 증가에 따른 신호변화를 측정하였다.

Hot Wall Epitaxy(HWE)범에 의한 $CuInSe_2$ 단결정 박막 성장과 가전자대 갈라짐에 대한 광전류 연구 (Growth and photocurrent study on the splitting of the valence band for $CuInSe_2$ single crystal thin film by hot wall epitaxy)

  • 홍명석;홍광준
    • 한국결정성장학회지
    • /
    • 제14권6호
    • /
    • pp.244-252
    • /
    • 2004
  • $CuISe_2$ 단결정 박막은 수평 전기로에서 합성한 $CuInSe_2$ 다결정을 증발원으로하여, hot wall epitaxy(HWE) 방법으로 증발원과 기판(반절연성-GaAs(100))의 온도를 각각 $620^{\circ}C$, $410^{\circ}C$로 고정하여 단결정 박막을 성장하였다. 이때 단결정 박막의 결정성은 광발광 스펙트럼과 이중결정 선 요동곡선(DCRC) 으로 부터 구하였다. Hall 효과는 van der Pauw 방법에 의해 측정되었으며, 293K에서 운반자 농도와 이동도는 각각 $9.62\times10^{16}/\textrm{cm}^3$, 296 $\textrm{cm}^2$/Vㆍs 였다. $CuAlSe_2$/Si(Semi-Insulated) GaAs(100) 단결정 박막의 광흡수와 광전류 spectra를 293k에서 10K까지 측정하였다. 광흡수 스펙트럼으로부터 band gap $E_g$(T)는 Varshni 공식에 따라 계산한 결과 1.1851 eV-($8.99\times10^{-4} eV/K)T^2$/(T+153k)였다. 광전류 스펙트럼으로 부터 Hamilton matrix(Hopfield quasicubic mode)법으로 계산한 결과 crystal field splitting Δcr값이 0.0087eV이며 spin-orbit Δso값은 0.2329 eV임을 확인하였다. 10K일 때 광전류 봉우리들은 n = 1일때 $A_1-, B_1$-와 $C_1$-exciton봉우리임을 알았다.

원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구 (Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers)

  • 정동혁;김진기;김기환;오영기;김수곤;이강규;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.30-36
    • /
    • 2009
  • Co-60 선원에 대해 교정된 원통형 전리함 이용하여 Ir-192 선원에 대한 공기커마세기를 측정하는 경우에 선질 차이에 대한 보정이 필요하다. 본 연구에서는 측정학적 방법을 적용하여 PTW-N30001과 N23333 전리함에 대하여 Ir-192 감마선에 대한 선질 인자를 결정하였다. Ir-192 선원(microSelectron)의 에너지스펙트럼을 적용할 경우에 선질인자($k_u$)는 두 전리함에 대해 각각 $k_u$=1.016 (N30001)과 $k_u$=1.017 (N23333)으로 계산되었다. 치료용 microSelectron 선원에 대해 선질 인자를 적용하여 공기커마 세기를 측정하였으며 결과를 기준값과 비교하였다. 결과적으로 선질인자를 적용하는 경우에 기준 공기커마율과 약 -0.5% 이내의 차이를 보였으며 적용하지 않는 경우에는 약 -2.0%의 차이를 보였다.

  • PDF

Hot Wall Epitaxy(HWE)법에 의한 CuAlSe2 단결정 박막의 성장과 가전자대 갈라짐에 대한 광전류 연구 (Photocurrent Study on the Splitting of the Valence Band and Growth of CuAlSe2 Single Crystal Thin Film by Hot Wall Epitaxy)

  • 박창선;홍광준;박진성;이봉주;정준우;방진주;김현
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.157-167
    • /
    • 2004
  • A stoichiometric mixture of evaporating materials for $CuAlSe_{2}$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $CuAlSe_{2}$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperatures were $680^{\circ}C$ and $410^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of $CuAlSe_{2}$ single crystal thin films measured with Hall effect by van der Pauw method are $9.24{\times}10^{16}cm^{-3}$ and $295cm^{2}/V{\codt}s$ at 293 K, respectively. The temperature dependence of the energy band gap of the $CuAlSe_{2}$ obtained from the absorption spectra was well described by the Varshni's relation, $E_{g}(T)$ = 2.8382 eV - ($8.68{\circ}10^{-4}$ eV/K)$T^{2}$/(T + 155 K). The crystal field and the spin-orbit splitting energies for the valence band of the $CuAlSe_{2}$ have been estimated to be 0.2026 eV and 0.2165 eV at 10 K, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_{5}$ states of the valence band of the $CuAlSe_{2}$. The three photocurrent peaks observed at 10 K are ascribed to the $A_{1-}$, $B_{1-}$, and $C_{1-}$ exciton peaks for n = 1.