• Title/Summary/Keyword: Gamma Distribution

Search Result 869, Processing Time 0.035 seconds

Reliability Calculation of Power Generation Systems Using Generalized Expansion

  • Kim, Jin-O
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.123-130
    • /
    • 1997
  • This paper presents a generalized expansion method for calculating reliability index in power generation systems. This generalized expansion with a gamma distribution is a very useful tool for the approximation of capacity outage probability distribution of generation system. The well-known Gram-Charlier expansion and Legendre series are also studied in this paper to be compared with this generalized expansion using a sample system IEEE-RTS(Reliability Test System). The results show that the generalized expansion with a composite of gamma distributions is more accurate and stable than Gram-Charlier expansion and Legendre series as addition of the terms to be expanded.

  • PDF

The Visualization and the Fast Detection of Gamma Radiation Source using Stereo Image Processing (영상처리기반 감마선원 거리탐지 고속화 및 가시화 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.2001-2006
    • /
    • 2016
  • The stereo radiation detection system detects the gamma source and acquires two dimensional left and right images for gamma source and visible objects using the detection result. And then the system measures the distance to the radiation source from the system in 3D space using stereo vision algorithm. In this paper, we implemented the fast detection algorithm for gamma source from the system in 3D space to reduce the detection time with image processing algorithms. Additionally, the system's performance is verified through experiments on gamma irradiation facilities. As a result, if the fast detection algorithm applied to the system, we can confirm that the detection system represents a 35% better performance than the conventional detection method that is full scanning to acquire the stereo image. We also have visualized a gamma source distribution through a 3D monitor using the stereo vision algorithm in order to provide the information of radiation spatial distribution to the user efficiently.

A Study on Scattering Distribution in Metal of Ir-192 Gamma-Ray (Ir-192 $\gamma$선(線)의 금속(金屬)에 대(對)한 산란분포(散亂分布)에 관(關)한 연구(硏究))

  • Joo, Gwang-Tae
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.63-71
    • /
    • 1981
  • The metal-plates(Aluminium. Copper, Lead) of change the variation thickness have been penetrated by the collimated beam($450mm{\times}4mm{\phi}$) of Gamma-ray from $^{192}Ir$. Then, the scattered $\gamma$-ray dose in variable angle and the directly transmitted $\gamma$-ray dose were measured using the electrometer of ionization chamber. The results were summarized as follows: 1. Obtained the mass attenuation coefficients of $Al;0.0937cm^2g^{-1},\;Cu;0.0937cm^2g^{-1},\;pb;0.244cm^2g^{-1}$. 2. Total intensity of front scattered $\gamma$-ray follow the order of Al>Cu>pb. 3. The scattered $\gamma$-ray intensity with the lager angle of scattering was saturated after increase rapidly, and the scattering angle of the more larger was decreased. 4. The scattered $\gamma$-ray intensity through plates of aluminium or copper was saturated after increase with thicker scatterer, and the intensity was decreased at the more thicker. But the variation of scattered $\gamma$-ray dose in the lead plate made the fewest than Al and Cu. 5. The ratio of the scattered $\gamma$-ray dose and the directly transmitted $\gamma$-ray dose was saturated after increase with the thicker scatterer, and the scatterer of the more thicker was decreased. Degree of total intensity in these ratios was followed the order of Cu>Al>Pb.

  • PDF

Comparative Analysis of Treatment Planning System and Dose Distribution of Gamma knife PerfexionTM using EBT-3 Film (EBT-3 필름을 사용한 감마나이프 퍼펙션TM의 치료 계획 시스템 및 선량 분포 비교 분석)

  • Jin, Seongjin;Kim, eongjin;Seo, Weonseop;Hur, Beongik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.509-515
    • /
    • 2017
  • The purpose of this study is to measure the 3 dimensional dose distribution of Gamma knife $Perfection^{TM}$, make a comparative analysis of the result and establish the measurement method for the procedures using EBT3 film. The dose distributions of the Gamma knife $Perfection^{TM}$ installed in two hospitals were evaluated in accuracy and precision. For accuracy, the difference between the mechanical center axis and the dose center axis was assessed on a 4 mm collimator. The allowed difference in accuracy is within 0.3 mm and it was measured as 0.098 mm, 0.195 mm for A hospital and 0.229 mm, and 0.223 mm for B hospital. For precision the difference between the FWHM(Full Width at Half Maximum) of Gamma Plan and measurement in the 4, 8, and 16 mm collimators was calculated. The allowed difference in precision is less than ${\pm}1mm$. The value of the hospital A was -0.283 ~ 0.583 mm, and the hospital B was -0.857 ~ 0.810 mm. When analyzing the dose distributions using the image-j program, it is necessary to establish a clearer reference point of the measurement point, and it is considered that the comparison of the dose distribution should be performed in actual treatment irradiation dose with a high dose usable film.

MCMC Algorithm for Dirichlet Distribution over Gridded Simplex (그리드 단체 위의 디리슐레 분포에서 마르코프 연쇄 몬테 칼로 표집)

  • Sin, Bong-Kee
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2015
  • With the recent machine learning paradigm of using nonparametric Bayesian statistics and statistical inference based on random sampling, the Dirichlet distribution finds many uses in a variety of graphical models. It is a multivariate generalization of the gamma distribution and is defined on a continuous (K-1)-simplex. This paper presents a sampling method for a Dirichlet distribution for the problem of dividing an integer X into a sequence of K integers which sum to X. The target samples in our problem are all positive integer vectors when multiplied by a given X. They must be sampled from the correspondingly gridded simplex. In this paper we develop a Markov Chain Monte Carlo (MCMC) proposal distribution for the neighborhood grid points on the simplex and then present the complete algorithm based on the Metropolis-Hastings algorithm. The proposed algorithm can be used for the Markov model, HMM, and Semi-Markov model for accurate state-duration modeling. It can also be used for the Gamma-Dirichlet HMM to model q the global-local duration distributions.

Determination of Proton Beam Position Based on Prompt Gamma Ray Detection (즉발감마선을 이용한 양성자 빔 위치 측정에 관한 연구)

  • Seo, Kyu-Seok;Kim, Jong-Won;Kim, Chan-Hyeong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.69-71
    • /
    • 2004
  • The proton therapy of radiation therapy methods using Bragg Peak which is proton beam's characteristic dose distribution can give a normal tissue lower dose than cancer, comparing with the former existing radiation therapy methods. For exact treatment and patient' safety, we need to know proton beam's position in body, but a proton beam completely stops at treatment region and proton beam's range is uncertainly made by the variety of organs having each different density, so we aren't able to find a proton beam' position by suitable methods yet. With Monte Carlo Computing Method, as a result that we had simulated prompt gamma detection system using correlation of proton beam's absorbed dose distribution about water and prompt gamma distribution by nuclear interaction occurred by collisions of proton and water's hydrogen atoms, we could confirm that a proton beam's position was able to detect by using simulated prompt gamma detection system in body on the real-time

  • PDF

A Study on a Model of Rainfall Drop-Size Distribution over Daegwanryeong Mountainous Area Using PARSIVEL Observations (PARSIVEL 측정 자료를 활용한 대관령 산악지역 강수입자분포 모형 연구)

  • Park, Rae-Seol;Jang, Min;Oh, Sung Nam;Hong, Yun-Ki
    • Journal of the Korean earth science society
    • /
    • v.35 no.7
    • /
    • pp.518-528
    • /
    • 2014
  • In this study, a model of rainfall drop-size distribution was modified using PARSIVEL-retrieved rainfall drop-size distribution over Daegwanryeong mountainous area. A prototype model (Modified ${\Gamma}$ distribution model) applicable for this area was decided through the comparative analysis between results from models proposed by preceding research and PARSIVEL-retrieved data over Daegwanryeong mountainous area. In order to apply the prototype model for Daegwanryeong region, the parameters (${\alpha}$, A, B) were made via sensitivity experiments and models of the rainfall drop-size distributions for five cases of rainfall rate were proposed. Results from the proposed five models showed high correlations with PARSIVEL-retrieved data ($R^2=0.975$). In order to suggest a generalized form of rainfall drop-size distribution, interaction equations between rainfall rates and parameters (${\alpha}$, A, B) were investigated. The generalized model of the rainfall drop-size distribution was highly correlated with PARSIVEL-retrieved data ($R^2=0.953$), which means that the proposed model from this study was effective for simulating the rainfall drop-size distribution over Daegwanryeong region. However, the proposed model was optimized for rainfall drop-size distribution over Daegwanryeong region. Therefore, broad observations of other regions are necessary in order to develop the representative model of the Korean peninsula.

Effect of Gamma-Irradiation on the Molecular Properties of Blood Plasma Proteins

  • Song, Kyung-Bin;Lee, Seunghwan;Lee, Seunghyun
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.2
    • /
    • pp.184-187
    • /
    • 2002
  • Blood products from slaughterhouses that are not hygienically prepared for disposal or food consumption pose a human health hazard. Gamma irradiation is an effective method for sterilization of blood products, but may introduce changes in the molecular characteristics of proteins. This study evaluated the effects of irradiation on animal plasma proteins. Bovine and porcine blood was obtained from a slaughterhouse and the plasma proteins purified and lyophilized. The secondary structure and molecular weight distribution of the plasma protein solutions and powders were examined after ${\gamma}$-irradiation at 1, 5, 7 and 10 kGy. Gamma-irradiation affected the molecular properties of the protein solutions, but not the protein powders. Circular dichroism and sodium dodecyl sulfate-polyacrylamide gel electrophoresis studies showed that increased doses of ${\gamma}$-irradiation decrease the ordered structure of plasma proteins in solution, and cause initial fragmentation of the polypeptide chains and subsequent aggregation.

Patent Keyword Analysis using Gamma Regression Model and Visualization

  • Jun, Sunghae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.143-149
    • /
    • 2022
  • Since patent documents contain detailed results of research and development technologies, many studies on various patent analysis methods for effective technology analysis have been conducted. In particular, research on quantitative patent analysis by statistics and machine learning algorithms has been actively conducted recently. The most used patent data in quantitative patent analysis is technology keywords. Most of the existing methods for analyzing the keyword data were models based on the Gaussian probability distribution with random variable on real space from negative infinity to positive infinity. In this paper, we propose a model using gamma probability distribution to analyze the frequency data of patent keywords that can theoretically have values from zero to positive infinity. In addition, in order to determine the regression equation of the gamma-based regression model, two-mode network is constructed to visualize the technological association between keywords. Practical patent data is collected and analyzed for performance evaluation between the proposed method and the existing Gaussian-based analysis models.

Comparative Analysis on the Attributes of NHPP Software Development Cost Model Applying Gamma Family Distribution (감마족 분포을 적용한 NHPP 소프트웨어 개발비용 모형의 속성에 관한 비교 분석)

  • Hyo-Jeong Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.867-876
    • /
    • 2023
  • In this study, the attributes of the NHPP software development cost model applying the Gamma family distribution (Erlang, Log-Logistic, Rayleigh) were newly analyzed, and after comparing with the Goel-Okumoto basic model to verify the properties of the model, the optimal model was also presented based on this. To analyze software reliability, failure time data that occurred randomly during system operation was used, and the calculation of the parameters was solved using the maximum likelihood estimation. As a result of comprehensive evaluation through various attribute analysis (mean value function, development cost, optimal release time), it was confirmed that the Rayleigh model had the best performance. Through this study, the attributes of the software development cost model applying the Gamma family distribution, which has no previous research case, were newly identified. Also, basic design data could also be presented so that developers can efficiently utilize this research data at an early stage.