• 제목/요약/키워드: Gamma 모델

검색결과 413건 처리시간 0.032초

석창포가 알레르기성 비염 유발 동물 모델에 미치는 영향 (The Effects of Acorus gramineus on Changes of Nasal Tissue in Allergic Rhinitis Model)

  • 정의령;김윤범
    • 한방안이비인후피부과학회지
    • /
    • 제21권1호
    • /
    • pp.16-25
    • /
    • 2008
  • Background & Objectives : Rhinitis is an inflammation of nasal mucosa. The major symtoms are watery rhinorrhea, sneezing, itchy nose, and nasal obstruction. Allergic rhinitis is an immune reaction by allergen. So, we aimed to determine therapeutic effects of Acorus gramineus by observing changes in IL-4, $IFN-{\gamma}$ and the nasal mucosal tissue. Materials and Methods : Fifteen BALC/c mice were divided into three groups : m group(which ate low concentrated herbal medicine ), M group(which ate high concentrated herbal medicine) and control group. Control and experimental group were induced allergic rhinitis by Ovalbumin as the method of Levin and Vaz. Experimental group was orally administered the Acorus gramineus extract for 28days. We observed changes in IL-4, $IFN-{\gamma}$ and trans aminase(AST, ALT) in blood and nasal mucosa and submucosa. Results : There were no significant changes statistically in IL-4 and $IFN-{\gamma}$ in blood(p<0.05). And there were no hepatotoxicity with Acorus gramineus extract. Histologically, almost no inflammatory response in treatment group(m,M) against that there were inflammatory response(increased goblet cells, dilated vessels, edema of bowman's glands and injured olfactory hairs) in control group. Conclusion : According to above results, it is supposed that Acorus gramineus has no immunological effects on allergic rhinitis.

  • PDF

EDISON_CFD를 이용한 초음속 이중압축램프에서 난류 모델에 따른 유동현상 비교

  • 신호철
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제4회(2015년)
    • /
    • pp.585-589
    • /
    • 2015
  • 본 연구에서는 이중압축램프의 초음속 유동에서 발생하는 충격파 경계층 상호작용을 EDISON_CFD로 해석하기로 한다. 이중압축램프에선 역압력 구배로 인하여 경계층이 박리가 일어나게 되고 박리된 경계층이 다시 이중압축램프에 부착되어 생겨난 박리영역을 관찰할 수 있다. 박리영역의 앞뒤로 유동의 방향이 바뀌게 되면서 압축 팬(compression fan)과 재부착 팬(reattachment fan)이 충격파를 발생시키고 이중압축램프전방의 충격파와 만나서 복잡한 유동 구조를 가지게 됨을 확인하였다. 이와 같은 층류에서 난류, 박리와 재부착의 영역에서의 해석하기 위해선 해석자의 난류모델이 중요하다. $15^{\circ}-30^{\circ}$, $15^{\circ}-45^{\circ}$의 두 종류의 이중압축램프를 $k-{\omega}$ SST 난류 모델과 ${\gamma}-Re_{\theta}$ 천이 모델로 계산을 EDISON_CFD로 수행하였다. 난류 모델의 차이를 표면마찰계수, 압력계수, 마하수로 비교하여 차이점을 분석하였다.

  • PDF

방사성폐기물드럼 종류별 감쇠보정방법의 결정 (Determination of Attenuation Collection Methods According to the Type of Radioactive Waste Drums)

  • 곽상수;최병일;윤석중;이익환;강덕원;성기방
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.309-317
    • /
    • 1997
  • 비파괴적인 방법으로 방사성폐기물드럼에 대한 핵종분석을 수행할 때 드럼내 매질에 의한 방사선의 감쇠에 의해 핵종분석장치로 측정한 계수값은 실제 드럼내 방사능에 의한 계수값보다 작게 나타나 결과적으로 방사능의 측정결과가 과소평가된다. 그러므로 드럼내 매질에 의한 감쇠를 보정해 주어야 하는데 감쇠 보정방법은 드럼내 매질의 분포나 매질의 밀도에 따라 달리 적용해야 한다. 본 연구에서는 원자력발전소에서 발생하는 드럼 종류별로 모델드럼을 제작한 후 모델드럼에 표준감마선원을 넣고 핵종분석장치를 이용해 측정을 하여 드럼내 매질의 밀도를 구하였고, 이 값을 실제 매질의 밀도와 비교해 드럼종류에 따라 매질에 의한 최적의 감쇠 보정방법을 결정하였다. 그 결과 잡고체드럼의 경우에는 전송선원 보정방법과 평균밀도 보정방법, 차폐잡고체드럼의 경우 전송선원 보정방법과 두 감마선피크비교 보정방법이 최적의 감쇠 보정방법임을 알 수 있었고, 고밀도드럼인 폐수지, 농축폐액 및 폐필터드럼의 경우에는 평균밀도 보정방법과 두 감마선피크비교 보정방법을 사용해 드럼내 매질의 감쇠를 보정할 수 있다.

  • PDF

간헐(間歇) 수문과정(水文過程)의 모의발생(模擬發生) 모형(模型)(II) - Markov 연쇄와 연속확률분포(連續確率分布) - (A Simulation Model for the Intermittent Hydrologic Process (II) - Markov Chain and Continuous Probability Distribution -)

  • 이재준;이정식
    • 대한토목학회논문집
    • /
    • 제14권3호
    • /
    • pp.523-534
    • /
    • 1994
  • 본 연구의 목적은 간헐수문과정인 일강수계열의 모의발생 모델을 개발하는 것이다. 이를 위하여 연구(I)에서는 교대재생과정을 이용하여 강수발생과정을 해석하였으며, 본 연구(II)에서는 강수발생과정으로 Markov 연쇄를 이용하고 습윤일의 강수량 분포를 조합하여 일 강수계열을 모의발생하는 추계학적 모델을 개발하였다. Markov 연쇄로는 상태 2(건조, 습윤)의 1차 연쇄를 사용하였으며, 습윤일의 강수량 분포는 연속확률분포인 Gamma, Pearson Type-III(PT3), Extremal Type-III(T3E), Weibull 분포를 적용하였다. 일 강수계열 자료의 계절적 변동성을 고려하여 월별로 분리하여 해석하였으며, 강수발생과정과 습윤일의 강수량과정을 조합하여 구성한 두 개의 모의발생 모델 M-W, M-G 모델을 낙동강과 섬진강 유역의 7개 관측소에 적용하여 관측치와 모의발생치를 비교하므로써 모의발생 모델의 적용성을 확인하였다.

  • PDF

Gamma Scanning Test에 의한 대단위 차폐체의 결함 평가 연구 (A Evaluation of Shielding Deficiency by Means of Gamma Scanning Test)

  • 이봉재;서경원
    • 비파괴검사학회지
    • /
    • 제14권4호
    • /
    • pp.228-236
    • /
    • 1995
  • 본 연구에서는 비파괴검사 방법의 하나인 gamma scanning test에 의한 대단위 차폐체의 결함을 평가하는 방법을 제시하고 방사선 차폐를 해석하는 유용한 방법중의 하나인 Monte Carlo 코드로 이에 대한 검증을 하였다. Gamma scanning test로 차폐체의 결함을 평가하기 위한 모델은 원통형 차폐체를 대상으로 하였다. 먼저 방사성물질 운반용기에 대한 설계기준에 따라 기준차폐체를 설치하여 Co-60 선원과 섬광계수기로 기준치를 측정하고, 그 다음 실물의 원통형 차폐체를 측정하였다. 기준치로 원통형 차폐체의 납두께를 환산한 결과 결함두께는 최대 12mm로 평가되었다. 이를 검증하기 위한 MCNP 코드의 계산에서는 결함두께가 실험적 결과에 비해 4.1%에 해당하는 최대 11.6mm를 나타내었으며, 두 결과가 만족할 정도로 일치함을 보여주고 있다. 따라서 이러한 평가방법은 방사성물질을 사용하는 시설에 설치되는 대단위 방사선 차폐체나 대용량의 운반용기 차폐능 검사시 현장에서 적용시킬 수 있으며 측정치의 신뢰도를 제고할 수 있다. 앞으로 보다 정확한 측정을 위하여 차폐체의 두께 측정결과가 화면에 직접 표시되는 측정장치의 연구 개발이 요구된다.

  • PDF

실험적 간 발암모델에서 감마선 조사 쇠고기 섭취가 쥐의 항산화 방어체계에 미치는 효과 (Effects of $\gamma$-Irradiated Beef Feeding on Antioxidative Defense System in Experimental Hepatocarcinogenesis)

  • 김정희;진유리;강일준;변명우
    • 한국식품영양과학회지
    • /
    • 제28권3호
    • /
    • pp.646-653
    • /
    • 1999
  • This study was done to investigate the effect of ${\gamma}$ irradiated beef feeding on antioxidant vitamin levels and defense enzyme activities in diethylnitrosamine(DEN) initiated rats. Weaning Sprague Dawley male rats were fed the diet containing ${\gamma}$ irradiated ground beef at the dose 0, 3, 5 kGy as a 20% of protein source for 8 weeks. One week after feeding, rats were intraperitoneally injected twice with a dose of DEN(50mg/kg BW). As a promoter, 0.05% phenobarbital was fed in drinking water from one week after DEN treatment until the end of experiment. At the end of 8th week, serum level of vitamin C, serum and hepatic levels of retinol and tocopherol were determined. In addition, activities of cytosolic glutathione peroxidase, glutathione reductase, glutathione S transferase, catalase and hepatic superoxide dismutase(SOD) were measured. By ${\gamma}$ irradiation, there was no significant effect on serum and hepatic levels of vitamin C and tocopherol except a significant decreasing effect on hepatic retinol level. There was also no significant effect on the activities of enzymes involved in antioxidative defense system, However, DEN treatment led to a significant increase in activities of glutathione reductase and glutathione S transferase while the activity of glutathione peroxidase was decreased. The activities of hepatic SOD and catalase were not changed by DEN treatment. Overall results indicate that the consumption of low dose of ${\gamma}$ irradiated beef does not affect antioxidative defense system.

  • PDF

Support vector regression과 최적화 알고리즘을 이용한 하천수위 예측모델 (River stage forecasting models using support vector regression and optimization algorithms)

  • 서영민;김성원
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.606-609
    • /
    • 2015
  • 본 연구에서는 support vector regression (SVR) 및 매개변수 최적화 알고리즘을 이용한 하천수위 예측모델을 구축하고 이를 실제 유역에 적용하여 모델 효율성을 평가하였다. 여기서, SVR은 하천수위를 예측하기 위한 예측모델로서 채택되었으며, 커널함수 (Kernel function)로서는 radial basis function (RBF)을 선택하였다. 최적화 알고리즘은 SVR의 최적 매개변수 (C?, cost parameter or regularization parameter; ${\gamma}$, RBF parameter; ${\epsilon}$, insensitive loss function parameter)를 탐색하기 위하여 적용되었다. 매개변수 최적화 알고리즘으로는 grid search (GS), genetic algorithm (GA), particle swarm optimization (PSO), artificial bee colony (ABC) 알고리즘을 채택하였으며, 비교분석을 통해 최적화 알고리즘의 적용성을 평가하였다. 또한 SVR과 최적화 알고리즘을 결합한 모델 (SVR-GS, SVR-GA, SVR-PSO, SVR-ABC)은 기존에 수자원 분야에서 널리 적용되어온 신경망(Artificial neural network, ANN) 및 뉴로퍼지 (Adaptive neuro-fuzzy inference system, ANFIS) 모델과 비교하였다. 그 결과, 모델 효율성 측면에서 SVR-GS, SVR-GA, SVR-PSO 및 SVR-ABC는 ANN보다 우수한 결과를 나타내었으며, ANFIS와는 비슷한 결과를 나타내었다. 또한 SVR-GA, SVR-PSO 및 SVR-ABC는 SVR-GS보다 상대적으로 우수한 결과를 나타내었으며, 모델 효율성 측면에서 SVR-PSO 및 SVR-ABC는 가장 우수한 모델 성능을 나타내었다. 따라서 본 연구에서 적용한 매개변수 최적화 알고리즘은 SVR의 매개변수를 최적화하는데 효과적임을 확인할 수 있었다. SVR과 최적화 알고리즘을 이용한 하천수위 예측모델은 기존의 ANN 및 ANFIS 모델과 더불어 하천수위 예측을 위한 효과적인 도구로 사용될 수 있을 것으로 판단된다.

  • PDF

4 kGy로 감마선 살균처리된 환자용 균형영양식의 유전독성 평가 (Genotoxicity evaluation of balanced nutritional food for patients pasteurized by gamma irradiation at 4 kGy)

  • 송범석;박종흠;김재경;박하영;김동호;홍성길;정상희
    • 한국식품저장유통학회지
    • /
    • 제24권1호
    • /
    • pp.100-106
    • /
    • 2017
  • 본 연구는 환자용 균형영양식으로 제조하여 감마선 조사처리를 통해 살균한 모델식품의 유전독성 여부를 평가하기 위해 수행되었다. 4 kGy 이상의 흡수선량으로 감마선 조사 처리한 시료에서 생균수가 1 log CFU/g의 검출한계 이하로 나타났기 때문에 살균을 위한 조사처리 선량으로 4 kGy를 설정하였다. 복귀돌연변이 유발성 평가 결과, 모델식품의 열수 추출물과 메탄올 추출물은 처리한 용량과 대사활성계 존재 여부와는 상관없이 음성대조구(멸균증류수 또는 DMSO)와 유사한 수준의 복귀돌연변이 발생빈도를 나타내었다. 염색체 이상 시험에서 실험군들의 정상 염색체의 수는 음성대조군과 유사하였으며, 용량 및 대사활성계에 대한 비의존성을 나타내어 염색체 이상 유발능은 없는 것으로 판단하였다. 또한 최고 2,000 mg/kg 체중의 농도로 모델식품을 경구 투여한 마우스의 골수세포에서도 소핵 다염성적 혈구의 발생빈도는 음성대조군에 비해 유의적인 차이를 나타내지 않았다. 따라서 4 kGy의 흡수선량으로 감마선 조사처리한 환자용 균형영양식은 본 실험 조건하에서 유전독성을 나타내지 않는 것으로 사료된다.

상선 선원의 인적과실 평가 모델 구축기법: 선박관리회사 적용 실례 (Implementation Techniques for the Seafarer's Human Error Assessment Model in a Merchant Ship: Practical Application to a Ship Management Company)

  • 임정빈
    • 한국항해항만학회지
    • /
    • 제33권3호
    • /
    • pp.181-191
    • /
    • 2009
  • 일반적으로 상선에서 해상운송 사고의 주된 원인은 원의 인적과실로 고려되고 있다. 본 논문에서는 선박에 승선 중인 선장, 1항사, 2항사 및 3항사를 포함하는 갑판사관들이 야기할 수 있는 사고 위기를 평가하기 위한 인적과실 모델(HEM)의 구축기법에 관해서 기술했다. 연구범위는 130척의 선박을 관리하는 회사에 소속된 542명의 갑판사관들을 대상으로 했다. 우선, 갑판사관들의 인적 데이터에 대한 통계적 분석과 전문가에 의한 브레인스토밍 과정을 통해서 KEM을 구축하고, 인적과실을 평가하기 위한 인적요소들의 변수 $\upsilon$$\upsilon$에 대한 평가등급 EP($\upsilon$) 및 가중치 $\alpha$, 갑판사관의 직책별 가중치 $\beta$ 등을 결정했다. 그리고 선박의 사고기록에 대한 통계분석 결과, 인적과실에 의한 사고원인 비율 ${\gamma}_H$와 외적과실에 의한 사고원인 비율 ${\gamma}_B$은 0.517(51.7%)과 0.483(48.3%)로 나타났다. $\upsilon$의 상관계수는 95%(p < 0.05) 신뢰구간에서 유의함을 확인하였고, 각 갑판사관의 위기수준 RL의 정규 확률분포 분석으로부터 HEM의 타당성을 검토했다.

감마선이 조사된 세포막모델을 통한 알칼리금속 이온의 선택적 전달 특성 (Selective transport characteristics of alkali metal ions through a cell membrane model which irradiated by γ-ray)

  • 고인호;여진동
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.85-91
    • /
    • 2013
  • 감마선이 조사된 세포막 모델에서 $K^+$$Na^+$의 선택적 전달특성을 연구하였다. 이 실험에 사용된 세포막 모델은 $Na^+$ 슬폰화 폴리스티렌-디비닐벤젠(polystyrene-divinylbenzene) 혼성 중합막을 사용하였다. 이온의 초기플럭스는 $H^+$ 이온 농도의 증가와 함께 증가하였다. 이 실험의 조건을 pH 0.5-3, 온도 $15-65^{\circ}C$로 하여 첫 번째 조사되지 않은 막의 $K^+$$K^+/Na^+$의 선택도는 약 1.06 - 1.13이고 두 번째 조사된 막의 $K^+$$K^+/Na^+$의 선택도는 약 0에 가깝다. 조사된 막의 pH의 추진력은 조사되지 않은 막보다 약 4-5배 정도 유의성 있게 증가하였다. 세포막모델에서 $K^+$$Na^+$의 선택적 전달특성이 비정상적이기 때문에 세포장해가 세포에서 발현된다.