• 제목/요약/키워드: Galvanic effect

검색결과 82건 처리시간 0.023초

3.5% NaCl 수용액 중에서의 금속과 GECM의 갈바닉 부식에 미치는 면적비의 영향 (Effect of Area Ratio on Galvanic Corrosion Between Metallic Materials and GECM in 3.5% NaCl Solution)

  • 김영식;임현권;손영일;유영란;장현영
    • Corrosion Science and Technology
    • /
    • 제9권1호
    • /
    • pp.39-47
    • /
    • 2010
  • Galvanic coupling between GECM(graphite epoxy composite material) and metallic materials can facilitate corrosion of metals and alloys because GECM is noble and electrically conductive. Galvanic corrosion is affected by many factors including metallic materials, area ratio, surface condition, and corrosivity. This work aims to evaluate the effect of area ratio on galvanic corrosion between GECM and several metals. In the case of glavanic coupling of carbon steel and Al to GECM, corrosion rate increased with increasing area ratio. Corrosion rate of sensitized STS 316S stainless steel decreased a little at an area ratio 1:1 but increased at an area ratio 30:1. It is considered to be due to that area ratio affects galvanic corrosion more in less corrosion resistant alloys. However, in case of STS 316 and Ti, galvanic coupling reduces corrosion rate by the formation of passive film.

금속재료의 전기화학적 갈바닉 부식에 미치는 GECM의 영향 (Influence of Graphite Epoxy Composite Material on the Electrochemical Galvanic Corrosion of Metals)

  • 유영란;손영일;심규태;권용혁;김영식
    • Corrosion Science and Technology
    • /
    • 제8권1호
    • /
    • pp.27-39
    • /
    • 2009
  • Non metallic composite materials, for example, GECM(graphite epoxy composite material) show high specific strength because of low density. These kinds of non metallic composite materials improved the structural effectiveness and operation economics. However, if these materials contacted several metals, corrosion can be arisen since non metallic composite materials have electrical conductivity. This paper dealt with galvanic corrosion between graphite epoxy composite material and several metals. Base on the electrochemical galvanic corrosion test between GECM and metals, corrosion current of carbon steel and aluminium increased with time but corrosion current of stainless steels and titanium decreased and galvanic potential increased. This behavior shows the galvanic corrosion depends upon the presence of passive film. Also, galvanic effect of GECM coupled with ferrous alloys and non-ferrous alloys was lower than that of 100% graphite, which is attributed to lower exposed area of graphite fiber in the GECM than apparent area of the GECM specimen used for the calculation of galvanic current in this work.

아연-니켈합금 전기도금층의 부식특성 (Corrsion of Ni-Ze Electrodeposited Alloy)

  • 예길촌;신현준
    • 한국표면공학회지
    • /
    • 제21권2호
    • /
    • pp.39-46
    • /
    • 1988
  • Corrosion behavior of 5-26wt% Ni-Zn electrodeposited alloys was investigated by means of dipping electrochmical polarization measurement and galvanic coupling test. The weight loss and anodic polarization curve of coatings were measured by means of dipping and polarization measurement respectively. The galvanic protection effect of alloy coatings was measured by galvanic coupling test and the surface morpholgy of coatings was observed after corrosion testing. Our findings support thous of previous investigations showing that ${\gamma}$single phase coatings, while galvanic pprotection effect of dual phase coatings improved in comparison with ${\gamma}$single phase coating. The formation of colony in coating of ${\gamma}$and η+${\gamma}$ dual phsae caused the localized corrsion and increased the corrosion rate of the Ni-Zn coating.

  • PDF

이종금속 연결에 따른 침부식(FAC) 특성에 관한 연구 (A Study on the Flow-Accelerated Corrosion Characteristics of Galvanically Coupled Dissimilar Metals.)

  • 김정구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.269-272
    • /
    • 2000
  • The flow accelerated galvanic corrosion characteristics of a carbon steel coupled to stainless steel were investigated in deaerated alkaline-chloride solutions as a function of flow velocities(0, 0.2, 0.4 and 0.6 m/s), pH(8, 9, and 10) and temperature(25, 50 and $75^{\circ}C$). The electrochemical properties of specimens were investigated by potentiodynamic test and galvanic corrosion test using RCE(Rotating Cylinder Electrode). Carbon steel did not show passive behavior in the alkaline-chloride solution. The galvanic current density increases with increasing flow velocity and temperature, but decreased with increasing pH. Flow velocity had a small effect on the galvanic current density at $25^{\circ}C$, whereas the flow velocity increased galvanic current density significantly at $50^{\circ}C$ and $75^{\circ}C$. This might be due to the increased solubility of magnetite at the higher temperature.

  • PDF

Galvanic Corrosion of AZ31 Mg Alloy Contacting with Copper

  • Phuong, Nguyen Van;Moon, Sungmo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.151.1-151.1
    • /
    • 2017
  • This work studied the corrosion behavior of AZ31 Mg alloy galvanically coupled with Cu during immersion in 0.1 and 0.5 M NaCl solutions by in-situ observation and galvanic corrosion current measurement using a zero resistance ammeter. The corrosion behavior of AZ31 Mg alloy was also studied by salt spray test. The average galvanic corrosion density during 2 h immersion in 0.1 NaCl solution was found to decrease as an exponential function with increasing the surface area ratios between AZ31:Cu or with increasing the distance between AZ31 and Cu. The corrosion of electrodeposited Cu on AZ31 Mg alloy was concentrated at the area next to Cu (about 5 mm for immersion test and 2 mm for salt spray test) and pitting corrosion was accelerated at the area beyond the severely corroded area by the galvanic coupling effect.

  • PDF

평류안뜰자극이 자율신경성 반응에 미치는 영향 (The Effect of Galvanic Vestibular Stimulation on Autonomic Nervous System Response)

  • 문화영;강솔;김화성;허소영;손유리;이정우
    • 대한임상전기생리학회지
    • /
    • 제8권2호
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose : This study aims to examine the influences of galvanic vestibular stimulation on autonomic reaction of normal adults. Methods : Participants in this research totaled 28 (14 men and 14 women). Galvanic vestibular stimulation was conducted with a binaural electrode configuration for 60 sec. Galvanic vestibular stimulation measurements were conducted with the subjects in a prone position. Measured items included skin conductance, blood flow, pulse rate, and respiratory rate. Measurements were repeated for a total of five times, before application, during application, after application, 5 minutes after application and 10 minutes after application. Results : Skin conductance reaction showed statistically significant differences in changes depending on time after galvanic vestibular stimulation and there were statistically differences in changes of blood flow, pulse rate and respiratory rate after galvanic vestibular stimulation. Conclusion : Blood flow, pulse rate and respiratory rate of autonomic reactions were not influenced by galvanic vestibular stimulation, but skin conductance reaction was influenced by it and it was found that it was reduced during and after stimulation rather than before stimulation. Consequently, it was considered that galvanic vestibular stimulation affected the autonomic reaction.

해수 열교환기용 재료의 부식특성에 관한 전기 화학적 연구 (An Electrochemical Study on the Corrosion Property of Materials for Sea Water Heat Exchange System)

  • 김진경;김강희;김성종;박근현;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.99-107
    • /
    • 2002
  • Recently all kinds of structural materials are subjected to the severe corrosive environment. Especially corrosion problems of heat exchanger such as galvanic corrosion, erosion and cavitation raised by both contaminated solution and high velocity of fluid to increase cooling effect of heat exchanger have been frequently reported in these days. In this study two kinds of sheet materials and five kinds of tube materials are used for galvanic corrosion characteristics and their corrosion current density calculation. The tube materials having the most galvanic corrosion resistance between tube and sheet of heat exchanger were Al Brass(68700) and Al Brass(C6872TS) and although Ti tube predominantly indicated the highest individual corrosion resistance among those five tube materials. it appeared that Ti tube can be allowed as sheet materials to get galvanic corrosion easily. However it is considered that Cu-Ni tube materials is not only easy to produce galvanic corrosion significantly between tube and sheet regardless of kinds of sheet materials but also is appeared considerably its own high corrosion current density

Hydrogen Evolution Ability of Selected Pure Metals and Galvanic Corrosion Behavior between the Metals and Magnesium

  • Luo, Zhen;Song, Kaili;Li, Guijuan;Yang, Lei
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권4호
    • /
    • pp.323-329
    • /
    • 2020
  • The cathodic hydrogen evolution ability of different pure metals and their long term galvanic corrosion behavior with pure Mg were investigated. The hydrogen evolution ability of pure Ti, Al, Sn and Zr is weak, while that of Fe, W, Cr, and Co is very strong. Initial polarization test could not completely reveal the cathodic behavior of the tested metals during long term corrosion. The cathodic hydrogen evolution ability may vary significantly in the long term galvanic tests for different metals, especially for Al whose cathodic current density reduced to 1/50 of the initial value. The anodic polarization shows that Al and Sn as alloying elements are supposed to provide relatively good passive effect for Mg alloy, while Ag can provide a slight passive effect and Zn has little passive effect.

족삼리(足三里) 침자(鍼刺)가 인체(人體)의 Skin temperature, Galvanic skin response 및 Heart rate에 미치는 영향(影響) (Effect of Acupuncture ST36 on Skin Temperature, Galvanic Skin Response and Heart Rate in Humans)

  • 윤대환;나창수
    • Korean Journal of Acupuncture
    • /
    • 제20권3호
    • /
    • pp.29-34
    • /
    • 2003
  • Objectives : The purpose of this study was to investigate the Effect of Acupuncture Chok-samni(ST36) on Skin temperature(ST), Galvanic skin response(GSR) and Heart rate(HR) in humans. ST36 is used in uneasiness, high fever, stroke, paralysis on oriental medicine. Methods : Subjects were 18 healthy oriental medical students volunteers(15male, 3female, mean age-28). Under sequence of ST36 acupuncture, the first group was observed ST, the second group was observed GSR and the third group was observed HR. Skin temperature was measured on Haegye acupoint(ST41) before and after acupuncture stimulation. Each test took 15minutes. This test was performed twice in order to increase the statistical authenticity. Results : Our result indicates that acupuncture stimulation of ST36 statistically decreased skin temperature on ST41. Also statistically decreased in HR. The change of GSR after ST36 acupuncture was decreased, but there is no statistical. Conclusions : These results suggested that acupuncture stimulation of ST 36 has effect on ST and HR in human body, and may be used by treatment as control the nerve system.

  • PDF

구리의 내식성에 미치는 어닐링 열처리의 영향 (Effect of Annealing Heat Treatment to Corrosion Resistance of a Copper)

  • 김진경;문경만;이진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.654-661
    • /
    • 2005
  • Copper is a well known alloying element that is used to improve the resistance to general corrosion of stainless steel And also Cu cation have the anti-fouling effect to inhibit adhesion of the marine algae and shellfish to the surface of heat exchanger cooling pipe or outside wall of the ship, Therefore there are some anti-fouling methods such as anti-fouling Paint mixed with copper oxide or MGPS(Marine Growth Preventing System) by using Cu cation dissolved to the sea wather solution. Cu cation can be dissolved spontaneously by galvanic current due to Potential difference between Cu and cooling pipe of heat exchanger with Ti material, which may be one of the anti-fouling designs. In this study the effect of annealing heat treatment to galvanic current and Polarization behavior was investigated with a electrochemical points of view such as measurement of corrosion Potential, anodic polarization curve. cyclic voltammetric curve, galvanic current etc The grain size of the surface in annealed at $700^{\circ}C$ was the smallest than that of other annealing temperatures. and also the corrosion Potential showed more positive potential than other annealing temperatures. The galvanic current between Ti and Cu with annealed at $700^{\circ}C$ was the largest value in the case of static condition. However its value in the case of flow condition was the smallest than the other temperatures. Therefore in order to increase anti-fouling effect by Cu cation, the optimum annealing temperature in static condition of sea water is $700^{\circ}C$, however non- heat treated specimen in the case of flow condition may be desirable.