• Title/Summary/Keyword: Galvanic

Search Result 350, Processing Time 0.025 seconds

Microstructure and Corrosion Behavior of Mg-xSn (x = 1, 3, 5, 7, 9 wt.%) Alloys (Mg-xSn(x = 1, 3, 5, 7, 9 wt.%) 합금의 미세조직 및 부식특성)

  • Kang, Yong-Muk;Kim, Sang-Hyun;Jo, Su-Mi;Park, Kyung-Chul;Kim, Byeong-Ho;Park, Ik-Min;Park, Yong-Ho
    • Journal of Korea Foundry Society
    • /
    • v.31 no.6
    • /
    • pp.362-365
    • /
    • 2011
  • In the present work, the corrosion properties of Mg-xSn (x = 1, 3, 5, 7 and 9 wt.%) alloys have been investigated. Potentiodynamic polarization and immersion tests were carried out in 3.5% NaCl solution of pH 7.2 at room temperature to measure the corrosion properties of Mg-xSn (x = 1, 3, 5, 7 and 9 wt.%) alloys. With increase of the Sn contents, the volume fraction of the $Mg_2Sn$ phase was increased. The corrosion rate of Mg-xSn alloys was increased up to 7 wt.%Sn and decreased above 9 wt.%Sn. Initiation of galvanic site during immersion mainly occurred at Mg/$Mg_2Sn$ interface and propagation went into ${\alpha}$-Mg. For this reason, corrosion properties of Mg-xSn (added from 1 wt.%Sn to 7 wt.%Sn alloys) alloys are decreased because the galvanic site was increased with increasing Sn addition. In Mg-9wt.%Sn alloy, however, the corrosion site were changed from Mg/$Mg_2Sn$ interface to ${\alpha}$-Mg/$M_2Sng$ interface in lamellar structure. Preferentially corrosion of ${\alpha}$-Mg/$M_2Sn$ interface in lamellar structure impeded corrosion propagation went into ${\alpha}$-Mg.

Corrosion Characteristics of Catenary Materials in Electric Railway System (전차선로 가선재료의 부식특성)

  • 김용기;윤상인;장세기;이재봉
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.535-542
    • /
    • 2000
  • Pure copper, Cu-1.1wt%Cd and ACSR(Aluminum Conductor Steel Reinforced) have been used as Catenary Materials in Electric Railway System. Since these materials may have chance to be exposed to the corrosive environments like polluted air, acid rain and sea water, it is important not only to investigate the corrosion characteristics but also to measure corrosion rates in various corrosive environments. In order to examine corrosion characteristics according to the dissolved oxygen content, pH, chloride ion concentration ion, and the addition of Cd to Cu, a series of tests such as potentiodynamic polarization. a.c impedance spectroscopy and galvanic corrosion tests were carried out in these materials. Results showed that the addition of Cd to Cu and chloride ion in the solution have an adverse effect on the resistance to corrosion. Additionally, Galvanic currents between Al and steel wires of ACSR were confirmed by using ZRA(zero resistance ammeter) method.

  • PDF

A Study on the Corrosion of Al-Alloy Propeller Used for a Coasting Vessel (연안 선박용 Al합금 프로펠러의 부식에 관한 연구)

  • LIM, Uh-Joh;PARK, Hee-Ok;YUN, Byoung-Du
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.15 no.2
    • /
    • pp.176-183
    • /
    • 2003
  • Recently, with the tendency of lightening, high-strength and high-speed in the marine industries such as marine structures, ships and propellers, it is rapidly enlarged the use of the aluminium alloy. Therefore, there occurs much interest in the study on corrosion characteristics of aluminium alloy. This paper was studied on the corrosion characteristics of Al-Mg alloy propeller used for a coasting vessel. Under the various pH of marine environment, the corrosion test of Al-Mg alloy was carried out. And thus polarization resistance, corrosion potential, and current density behavior of Al-Mg alloy and galvanic corrosion behavior of Al-brass and Al-Mg alloy coupled Al 5086 and SS 400 for hull were investigated. The main results are as following: 1. The corrosion potential of Al-brass propeller is more nobel than materials for hull, but that of Al-Mg alloy propeller is low or similar to materials for hull. Therefore, the galvanic corrosion of hull due to Al-Mg propeller don't occur. 2. The polarization resistance of Al-Mg alloy in sea water of pH 4 is highest, and corrosion current density of Al-Mg propeller is the most controlled. 3. As pH value decreases, potential showed Evans polarization diagram approaches cathodic potential. The corrosion current density of Al-Mg alloy is controlled to anodic reaction rate, therefore, the corrosion reaction of Al-Mg alloy is anodic control.

Influence of Carbon Fiber on Corrosion Behavior of Carbon Steel in Simulated Concrete Pore Solutions

  • Tang, Yuming;Dun, Yuchao;Zhang, Guodong;Zhao, Xuhui;Zuo, Yu
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.175-182
    • /
    • 2017
  • Galvanic current measurement, polarization curves, electrochemical impedance spectroscopy and weight loss test were used to study the corrosion behavior of carbon steel before and after carbon fibers coupling to the carbon steel in simulated concrete pore solutions, and the film composition on the steel surface was analyzed using XPS method. The results indicate that passive film on steel surface had excellent protective property in pore solutions with different pH values (13.3, 12.5 and 11.6). After coupling with carbon fibers (the area ratio of carbon steel to carbon fiber was 12.31), charge transfer resistance $R_{ct}$ of the steel surface decreased and the $Fe^{3+}/Fe^{2+}$ value in passive film decreased. As a result, stability of the film decreased and the corrosion rate of steel increased. Decreasing of the area ratio of steel to carbon fiber from 12.3 to 6.15 resulted in the decrease in $R_{ct}$ and the increase in corrosion rate. Especially in the pore solution with pH 11.6, the coupling leads the carbon steel to corrode easily.

Effect of Heat Treatment on the Corrosion Properties of Seamless 304L Stainless Steel Pipe (이음매 없는 304L 스테인리스강관의 부식특성에 미치는 열처리의 영향)

  • Kim, K.T.;Um, S.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.305-316
    • /
    • 2017
  • Austenitic stainless steels have been widely used for various systems of nuclear power plants. Among these stainless steels, small pipes with diameter less than 14 inch have been produced in the form of seamless pipe. Annealing and cooling process during the manufacturing process can affect corrosion properties of seamless stainless steels. Therefore, 12 inch-diameter of as-received 304L stainless steel pipe was annealed and aged in this study. Intergranular corrosion resistance was evaluated by ASTM A262 Practice A, C, and E methods. The degree of sensitization was determined using a DL-EPR test. U-bend method in an autoclave was used to evaluate the SCC resistance in 0.01 M $Na_2S_4O_6$ or 40% NaOH solution at $340^{\circ}C$. As-received specimen showed relatively high degree of sensitization and intergranular corrosion rate. Carbon segregation was also observed near grain boundaries. Annealing treatment could give the dissolution of segregated carbon into the matrix. Aging treatment could induce segregation of carbon and finally form carbides. Microstructural analysis confirmed that high intergranular corrosion rate of the as-received seamless pipe was due to micro-galvanic corrosion between carbon segregation and grains.

The Effect of Pain Relieving Intervention During Infiltration among Gamma Knife Surgery Patients for Stereotactic Frame Fixation (감마나이프 수술 환자의 정위적 틀 고정을 위한 침윤 마취 시 통증 완화 중재의 효과)

  • Jang, Young Jun;Kim, Hyeon Ok
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.2
    • /
    • pp.221-231
    • /
    • 2018
  • Purpose: This study aimed to compare the effects of three interventions on pain, blood pressure, and pulse rate during infiltration anesthesia in patients about to undergo gamma knife surgeries. Methods: The three interventions employed in a university-affiliated Hospital in J City, South Korea were as follows: EMLA cream plus Vapocoolant spray (Vapocoolant, n=30), EMLA cream plus 10.0% Lidocaine spray (Lidocaine, n=30), and EMLA cream only (EMLA, n=30). The equivalent control-group pre test - post test study design was used. Pain was assessed subjectively using the numeric rating scale (NRS) and objectively using a Galvanic Skin Response (GSR) tester. NRS scores were assessed after infiltration anesthesia and the GSR was assessed during infiltration anesthesia. Blood pressure and pulse rate were assessed twice: before and after infiltration anesthesia. Data were collected between August 3, 2016 and March 24, 2017. Results: NRS scores after infiltration anesthesia and the GSR during infiltration anesthesia were significantly lower in the Vapocoolant group than in the Lidocaine and EMLA groups (F=13.56, p<.001 and F=14.43, p<.001, respectively). The increase in systolic blood pressure (F=4.77, p=.011) and in pulse rates (F=4.78, p=.011) before and after infiltration anesthesia were significantly smaller in the Vapocoolant group than in the Lidocaine and EMLA groups; however, no significant differences were observed in diastolic blood pressures (F=1.51, p=.227). Conclusion: EMLA cream plus Vapocoolant spray was the most effective intervention to relieve pain and to lower increase in systolic blood pressure and pulse rate caused by infiltration anesthesia for stereotactic frame fixation. Thus, application of Vapocoolant spray in addition to EMLA cream is highly recommended as a nursing intervention for patients undergoing gamma knife surgeries.

Effects of High Voltage Pulsed Galvanic Stimulation on Skeletal Muscle in Rats (고압맥동전류 자극이 흰쥐의 탈신경근 섬유 형태에 미치는 영향)

  • Park Hwan-Jin
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.145-152
    • /
    • 2002
  • This study was carried out of to determine effects of high voltage pulsed galvanic stimulation on the soleus. target muscle of the sciatic nerve, of white rat two condition. The coditions included normal, and denervated muscle. The histochemical, ultrastructural observations were made. The following results were obtains. 1. The histochemical observations found the inflammatory cells between muscle bundle and muscle fiber since 1-week control group. In addition, nucleus located in the muscle fiber was frequently observed. 2. The experimental group showed a similar phenomenom to the normal muscles in terms of glycogen granules in the 1-week group, where as fiber were not distinguishable in4-weeks group which indicated that the degenerative changes had occured. 3. The NADH-TR reaction showed that the red muscle slightly increased in the 2-weeks group, and the distinguished was impossible the red fiber 4. The ultrastructures of the muscles in both groups were severely bend, and a number of vacuoles were observed due to the destruction of mitochondria..

  • PDF

Corrosion Behavior of Aluminium Coupled to a Sacrificial Anode in Seawater (희생양극 하에서 알루미늄의 해수 부식 거동)

  • Kim Jong-Soo;Kim Hee-San
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.1
    • /
    • pp.25-34
    • /
    • 2006
  • Al-Mg alloy, an open rack vaporizer(ORV) material was reported to be corroded in seawater environments though the ORV material was coupled to thermally sprayed Al-Zn alloy functioning a sacrificial anode. In addition, the corrosion behavior based on the calculated corrosion potential did not match the observed corrosion behavior. Hence, the goal of this study is to get better understanding on Al or Al-Mg alloy coupled to Al-Zn alloy and to provide the calculated corrosion potential representing the corrosion behavior of the ORV material by immersion test, electrochemical tests, and calculation of corrosion and galvanic potential. The corrosion potentials of Al and Al alloys also depended on alloying element as well as surface defects. The corrosion potentials of Al and Al-Mg alloy were changed with time. In the meantime, the corrosion potentials of Al-Zn alloys were not. The corrosion rates of Al-Zn alloys were exponentially increased with zinc contents. The phenomena were explained with the stability of passive film proved by passive current density depending on pH and confirmed by the model proposed by McCafferty. Dissimilar material crevice corrosion (DMCC) test shows that higher content of zinc caused Al-Mg alloy corroded more rapidly, which was due to the fact that higher corrosion rate of Al-Zn makes [$H^+$] and [$Cl^-$] more concentrated within pit solution to corrode Al-Mg alloy. Considering electrochemical reactions within pit as well as bulk in the calculation gives better prediction on the corrosion behavior of Al and Al-Mg alloy as well as the capability of Al-Zn alloy for corrosion protection.

Attitudes Towards Homecare Beauty Devices in Women in Correlation to Narcissism (여성의 자기애에 따른 홈케어 뷰티디바이스 이용 태도)

  • Kang, Shin-Ok;Kim, Moon-Ju
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.5
    • /
    • pp.212-224
    • /
    • 2022
  • This study aims to provide data on attitudes towards the use of Homecare beauty devices in correlation to narcissism of women between ages 30-59. Through statistical analysis of 563 survey questions, data displayed that respondents' age, level of education, marital status, economic status, and career status showed a strong correlation with implicit narcissism, while explicit narcissism only showed a correlation with age and career status. The most popular skincare location was shown to be 'self-provided at home', and the most popular item purchased being 'galvanic devices'. Secondly, attitudes towards the use of homecare beauty devices in correlation towards implicit narcissistic respondents were only to the consideration of its use, while explicit narcissists displayed a strong correlation between the purchase of a product and the recommendation of others. While this is the first study on attitudes towards homecare beauty devices in relation to a personality-based trait like narcissism and it displayed meaningful results, a more in-depth study in the future dealing with a larger region and respondent groups of a wider age and gender group should be undertaken.

A research on attentive gaze by physiological signal (생리신호에 의한 시선 집중도 추출에 대한 연구)

  • Kim, Jong-Hwa;Hwang, Min-Cheol;Park, Gang-Ryeong;Lee, Ui-Cheol;U, Jin-Cheol;Kim, Chi-Jung;Kim, Yong-U;Kim, Ji-Hye
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.160-163
    • /
    • 2009
  • 본 연구는 생리신호에 의한 집중된 시선과 집중하지 않는 시선을 분류하고자 한다. 이를 검증하기 위해 시각적으로 높은 집중과 낮은 집중을 요구하는 두가지 과제를 피실험자에게 제시하고 PPG(Photoplethysmogram), GSR(Galvanic Skin Response) 그리고 SKT(Skin Temperature)센서를 사용한 자율신경계 반응과 시선 움직임을 측정하였다. 과제는 $3{\times}3$으로 화면 구역을 나누고 각 구역에 문자를 제시하고 역방향 문자를 찾도록 하였다. 실험에는 20 명의 대학생이 참여하였으며, 1 번의 실험에 12 종류의 다른 문자배열을 제시 받았으며 1 번의 연습을 포함하여 총 5 회 실시후 데이터를 분석하였다. 높은 집중일 경우와 낮은 집중일 경우를 T-test 분석 결과, 자율신경계에서는 높은 집중일 경우 PPG 주파수가 증가하고 GSR과 SKT는 감소한 결과를 보였다. 따라서 시선의 집중도에 따라 다른 자율신경계 반응과 시선반응을 보이는 것을 확인하였다.

  • PDF