• 제목/요약/키워드: Gait signal

검색결과 83건 처리시간 0.022초

FES 보행을 위한 휴대용 보행 이벤트 검출 시스템 (Portable Gait-Event Detection System for FES Locomotion)

  • 공세진;김철승;박관용;엄광문
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권5호
    • /
    • pp.248-253
    • /
    • 2006
  • The purpose of this study is to develop a portable gait-event detection system which is necessary for the cycle-to-cycle FES(functional electrical stimulation) control of locomotion. To make the system portable, we made following modifications in the gait signal measurement system. That is, 1) to make the system wireless using Bluetooth communication, 2) to make the system small-sized and battery-powered by using low power consumption ${\mu}$ P(ATmega8535L). The gait-events were analyzed in off-line at the main computer using ANN(Artificial Neural Network). The Proposed system showed no mis-detection of the gait-events of normal subject and hemiplegia subjects. The performance of the system was better than the previous wired-system.

Relationships Between the Transfemoral Socket Interface Pressure and Myoelectric Signal of Residual Limb During Gait

  • Hong, J.H.;Lee, J.Y.;Chu, J.U.;Lee, J.Y.;Mun, M.S.
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1070-1073
    • /
    • 2002
  • The biomechanical interaction between the stump and the prosthetic socket is critically important to achieve close-to-normal ambulation. Many investigators suggested that the pressure changes during gait of transfemoral amputees are closely related to the prosthetic alignment, the socket shape, the stump size, and the residual muscle activity. The effects of the prosthetic alignment, the socket shape, and the stump size on the interface pressure were investigated previously. However, there is no report how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. Since designs of socket fur lower limb amputees need to consider the socket interface pressure characteristics, the interface pressure patterns by the residual muscle activities during gait should be investigated. In this study, myoelectric signals (MES) and socket interface pressure in residual limb of transfemoral amputees were measured during the stance and swing phases of gait. For the purpose, specially designed quadrilateral sockets that MES electrodes could be instrumented were fabricated. A total of two transfemoral amputees were participated in the experiments. The measured temporal MES amplitude and interface pressure in knee flexor (biceps femoris) and extensor (rectus femoris) had significant correlations (P < 0.05). Based on the test results, It was suggested that the residual muscle activity of transfemoral amputees stump is an important factor affecting socket pressure changes during walk.

  • PDF

Gait Angle Prediction for Lower Limb Orthotics and Prostheses Using an EMG Signal and Neural Networks

  • Lee Ju-Won;Lee Gun-Ki
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권2호
    • /
    • pp.152-158
    • /
    • 2005
  • Commercial lower limb prostheses or orthotics help patients achieve a normal life. However, patients who use such aids need prolonged training to achieve a normal gait, and their fatigability increases. To improve patient comfort, this study proposed a method of predicting gait angle using neural networks and EMG signals. Experimental results using our method show that the absolute average error of the estimated gait angles is $0.25^{\circ}$. This performance data used reference input from a controller for the lower limb orthotic or prosthesis controllers while the patients were walking.

다중 생체 신호 기반 보행 단계 감지 및 판단 (Gait Phases Detection and Judgment based Multi Biomedical Signals)

  • 김서준;정의철;송영록;윤광섭;이상민
    • 재활복지공학회논문지
    • /
    • 제6권2호
    • /
    • pp.43-48
    • /
    • 2012
  • 본 논문에서는 Electromyogram(EMG) 신호와 허벅지 각도 측정 장치, 발바닥 저항 센서를 이용하여 보행의 단계를 판단하는 방법을 제시한다. 신호의 측정을 위하여 건강한 성인 남성 5명을 대상으로 실험을 실시하였고 정상 보행에서의 EMG, 허벅지 각도, 발바닥 저항 센서를 통한 변화를 측정 하였다. EMG 신호의 획득을 위하여 실험자의 대퇴 사두근, 대퇴 이두근, 전경골근, 장딴지근에 Ag/AgCl 표면 전극을 부착하였으며, 양측 발뒤꿈치와 앞꿈치에 저항센서를 부착 하였다. 허벅지 각도 측정 장치는 굴곡 25도, 신전 20도 까지 범위를 가지며 이를 통하여 허벅지의 각도를 측정 하였다. 실험 결과 보행 시 입각기와 유각기를 명확히 판단 할 수 있었으며 세부적으로 8단계의 보행 상태를 판단 할 수 있었다.

  • PDF

상·하향 계단보행을 위한 근전도 신호 기반 보행단계 인식 (Gait Phase Recognition based on EMG Signal for Stairs Ascending and Stairs Descending)

  • 이미란;류재환;김상호;김덕환
    • 전자공학회논문지
    • /
    • 제52권3호
    • /
    • pp.181-189
    • /
    • 2015
  • 동력의족은 하지 절단 환자나 다리근력이 부족한 사람들의 보행 보조를 위해 사용된다. 동력의족의 자연스러운 구동을 위해 선 보행단계가 잘 분류되어야 한다. 물리센서를 이용하여 보행단계를 분류하는 기존 연구는 동력의족이 사전에 훈련된 보행속도로만 재현되는 단점이 있다. 따라서 본 논문에서는 물리센서를 사용하지 않고, 근전도 신호만을 이용하여 오르막, 내리막 계단보행을 각각 4단계로 분류하는 방법을 제안한다. 근전도 신호를 RMS, VAR, MAV, SSC, ZC, WAMP 특징으로 산출하여 LDA(Linear Discriminant Analysis) 분류기를 통해 보행단계를 인식한다. 훈련 단계에서는 AHRS센서를 이용하여 무릎각도 변화에 따른 보행단계 범위를 생성한다. 실험 결과, 선행 연구의 경우 오르막 보행에서 평균 58.5%, 내리막 보행에서 35.3%의 정확도를 보인다. 반면, 제안하는 방법은 오르막 보행에서 평균 85.6%, 내리막 보행에서 69.5%의 인식률을 보인다. 또한, 본 연구를 통해 개별 근육 별 보행단계 평균 인식률을 분석하였다.

보행주기 검출용 모션 센서 시스템의 비교 (Comparison of Motion Sensor Systems for Gait Phase Detection)

  • 박선우;손량희;류기홍;김영호
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

Influence of mobile phone texting on gait parameters during ramp ascent and descent

  • Kim, Hyunjin;Park, Jaemyoung;Cha, Jaeyun;Song, Chang-Ho
    • Physical Therapy Rehabilitation Science
    • /
    • 제3권1호
    • /
    • pp.43-48
    • /
    • 2014
  • Objective: The purpose of this study was to examine the influences on gait features during mobile phone use while ramp walking. Design: Cross-sectional study. Methods: Thirty-three healthy adult subjects performed four walking conditions on an outside ramp with a 5 m length, 1.5 m width, and a $5^{\circ}$ angle. All participants were touch screen mobile phone users. Four walking conditions were used: 1) ramp ascent, 2) ramp descent, 3) texting during ramp ascent, and 4) texting during ramp descent. In conditions 3) and 4), subjects texted the words of "Aegukga"-the song of patriotism-while walking. Upon the signal of start, the subjects walked the ramp during texting. Gait parameters were measured at the length of 3 m excluding 1 m of the start and end of the total length. Each situation was repeated three times for each subject, and mean values were calculated. For gait examination, a gait analyzer was used (OptoGait). Results: Subjects ranged in age from 23 to 38 years (mean age, 27.73). Eighty-three percent of subjects in our study had experienced an accident during mobile phone use. Texting on a mobile phone while walking significantly decreased ramp gait, speed, cadence, stride length, step length, and single support (p<0.05) and significantly increased stride time, step time, gait cycle, and double support (p<0.05). There was a significant difference in cadence, step length, stride time, step time, and single support during ramp ascent and descent (p<0.05). Conclusions: Texting on a mobile phone while walking significantly decreased gait quality.

Adaptive Cross-Device Gait Recognition Using a Mobile Accelerometer

  • Hoang, Thang;Nguyen, Thuc;Luong, Chuyen;Do, Son;Choi, Deokjai
    • Journal of Information Processing Systems
    • /
    • 제9권2호
    • /
    • pp.333-348
    • /
    • 2013
  • Mobile authentication/identification has grown into a priority issue nowadays because of its existing outdated mechanisms, such as PINs or passwords. In this paper, we introduce gait recognition by using a mobile accelerometer as not only effective but also as an implicit identification model. Unlike previous works, the gait recognition only performs well with a particular mobile specification (e.g., a fixed sampling rate). Our work focuses on constructing a unique adaptive mechanism that could be independently deployed with the specification of mobile devices. To do this, the impact of the sampling rate on the preprocessing steps, such as noise elimination, data segmentation, and feature extraction, is examined in depth. Moreover, the degrees of agreement between the gait features that were extracted from two different mobiles, including both the Average Error Rate (AER) and Intra-class Correlation Coefficients (ICC), are assessed to evaluate the possibility of constructing a device-independent mechanism. We achieved the classification accuracy approximately $91.33{\pm}0.67%$ for both devices, which showed that it is feasible and reliable to construct adaptive cross-device gait recognition on a mobile phone.

고령자 및 편마비 환자의 3 차원 동작분석을 통한 보행 특성에 관한 연구 (Study on Gait Analysis of Elders and Hemiplegia Patients using 3D Motion Analysis)

  • 장혜연;한정수;한창수
    • 한국정밀공학회지
    • /
    • 제29권7호
    • /
    • pp.730-736
    • /
    • 2012
  • Latest, many researchers do research on wearable robot. The purpose of the researches is very diverse, it will improve efficiency in the industry, taken to replace the many workers in the military field and taken to assist bodily functions run out by aging. However, there is no clear Differentiated strategy depending on the purpose for design and control of the wearable robot. Although a common purpose is to drive the robot by the sensor signal (intent signals), the optimization about the mechanism and control studies must be done according to the user's physical ability and purpose. In this study, the study's first phase for the development of wearable robotic gait rehabilitation, gait characteristics were analyzed elders and hemiplegia patients using a 3D gait analysis system (VICON512). As a result, asymmetric gait characteristics of the hemiplegia patients were found compared with the normal elderly.