The Comparison of Plantar Foot Pressure in Normal Side of Normal People, Affected Side and Less Affected Side of Hemiplegic Patients During Stance Phase (보행 중 입각기 시 정상 성인과 편마비 환자의 환측과 건측의 족저압 분포 비교)

  • Yoon, Hyang-Woon;Lee, Sang-Yeol;Lee, Hyun-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.2
    • /
    • pp.87-92
    • /
    • 2009
  • Objects:The purpose of this study is to investigate the values of foot pressure of the stance phase during a gait cycle in hemiplegic gait. Method:42 patients who had a stroke and 42 healthy adults were evaluated by the RSscan system to analyze the stance phase of hemiplegic gait. The stance phase was evaluated as plantar foor pressure. Results:1) Foot plantar pressure of toe area, affected side and less affected side showed low distribution of the plantar foot pressure which is lower than plantar foot pressure of normal adults(p<0.05). 2) Foot plantar pressure of metatarsal area, showed significantly differences among hemiplesic patient's affected side and less affected side and distribution of plantar foot pressure of normal adults(p<0.05). 3) Foot plantar pressure of heel area, hemiplesic patients' affected side and less affected side showed lower distribution of the plantar foot pressure than plantar foot pressure of normal adults(p<0.05). Conclusion:The results of this study suggest that not only affected side but also less affected side in hemiplegic patients showed significantly differences in distribution of the plantar foot pressure of normal adults.

  • PDF

The Effect of Height Increase Elevator Shoes Insole on Gait and Foot Pressure (키높이 깔창이 성인남성의 보행 및 발의 압력분포에 미치는 영향)

  • Goo, Bong-Oh
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.2
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of 0cm, 2.5cm, 5cm height increase elevator shoes insole on gait and foot pressure Methods: Fifteen young adult were recruited this study. Gait and foot was measured by Gait AnalyzerTM(Tech Storm Inc. korea). Statistical analysis was used one-way ANOVA to know difference between 0cm, 2.5cm insole and 5cm insole Results: There was no significantly difference on foot length, foot width, foot angle, step time during gait. But step length and step width was significantly difference during gait. There was no significantly difference on gait ratio during stance phase. There was significantly difference on forefoot pressure and rearfoot pressure ratio. Conclusion: These results indicate that height increase elevator shoes insole may be caused step length, step width decreaseed during gait. It caused forefoot pressure increased and rearfoot pressure decreased on foot.

A 3D Posture Measuring and Display System for Hemiplegic Patients (편마비 환자를 위한 3차원 보행 자세 측정 및 디스플레이 시스템)

  • Hwang, Yong-Ha;Kim, Yong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.119-127
    • /
    • 2014
  • TIn this paper, Hemiplegic patients have gait characteristics different from normal persons. This paper presents a posture measuring and display system reflecting their characteristics. Patients wear 3 sensor modules on thigh, calf and foot. To enhance measuring precision of each sensor module, 3D accelerometer and 3D gyroscope are combined. Gait posture is displayed in 3D by modeling thigh, calf and foot as connected 3D objects based on data of the sensor modules. For convenience in inspecting unusual gait posture of hemiplegic patients, any view angle of the 3D display can be selected. In addition, the current gait phase of RLA(Rancho Los Amigos) gait cycle is determined and displayed in real-time by utilizing the posture information, The phase sequence and duration of each phase can be used in evaluating gait quality of patients.

Effects of Performing Dual Task on Temporospatial Gait Variables in Subjects With Subacute Stroke (아급성기 뇌졸중 환자의 이중 과제 수행이 보행의 시·공간적 변수에 미치는 영향)

  • Jang, Young-Min
    • PNF and Movement
    • /
    • v.15 no.3
    • /
    • pp.361-371
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the effects of performing a dual task on gait velocity, temporospatial variables, and symmetry in subjects with subacute stroke. Methods: The study included 14 independent community ambulators with gait velocity of 0.8m/s. The Korean mini-mental state examination, the Berg balance scale, the Trunk impairment scale, and the Fugl-Meyer assessment scale were used to recruit homogeneous subjects. Subjects performed a single task (10m ambulation at a comfortable speed) and a dual task (10m ambulation at a comfortable speed while carrying a water-filled glass). Gait variables were examined with the OptoGait system. Results: The findings of this study were as follows: 1) Gait velocity decreased significantly in the dual-task condition as compared to the single task condition. 2) There were no significant differences between the paretic and non-paretic stances. 3) Paretic swing decreased significantly in the dual-task condition as compared to the single task condition. 4) The non-paretic, double-limb support phase increased significantly in the dual-task condition as compared to the single- task condition. 5) There was no significant difference in temporal symmetry. 6) Non-paretic step length decreased significantly in the dual-task condition as compared to the single-task condition. 7) There was no significant difference in spatial symmetry. Conclusion: Performing dual tasks decreases gait velocity, paretic swing phase, and non-paretic step length, while it increases non-paretic double limb support. In addition, although there is no difference in temporospatial symmetry, there is high inter-subject variability in temporospatial symmetry. Thus, dual tasks should be selected in accordance with the functional level of the hemiplegic patient, and inter-subject variability of the individual should be considered when dual tasks are considered for gait-training of hemiplegic patients.

The reliability test of a smart insole for gait analysis in stroke patients

  • Seo, Tae-Won;Lee, Jun-Young;Lee, Byoung-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.30-40
    • /
    • 2022
  • Background: This study analyzed the reliability of smart guides for gait analysis in patients with stroke. Design: Cross-sectional study. Methods: The participants of the study were 30 patients with stroke who could walk more than 10 m and had an MMSE-K test score of ≥24. Prior to the experiment, the subjects or their guardians entered their demographic characteristics including gender, age, height, weight into the prepared computer. The experiment was conducted in a quiet, comfortable, and independent location, and the patient was reminded of the equipment description, precautions, and safety rules for walking. A smart insole was inserted into the shoes of the patients and the shoes were put on before the patients walked three times on the 5-m gait analysis system mat installed in the laboratory. Results: The reliability of the equipment was compared with that of the gait analysis system, and the results of this study are as follows: among the gait analysis items, velocity had an ICC=0.982, the cadence had an ICC=0.905, the swing phase on the side of the gait cycle had an ICC=0.893, the swing phase on the side of the gait had an ICC=0.839, that on the non-affected side had an ICC=0.939, single support on the affected side had an ICC=0.812, and support on the non-affected side had an ICC=0.767. Conclusion: The results of this study indicate no statistical difference between the smart insole and the gait analysis system. Therefore, it is believed that real-time gait analysis through smart insole measurement could help patients in rehabilitation.

Effect of Trans cranial Directed Current Stimulus on Temporal and Spatial Walking Capacity for Hemiparalysis Patients (경 두개 직류자극이 뇌졸중 환자의 시간적, 공간적 보행능력에 미치는 영향)

  • Lee, Yeon Seop;Jun, Hun Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.3
    • /
    • pp.75-84
    • /
    • 2022
  • Background: This study was to investigate the effect of non-invasive transcranial direct current stimulation due to hemiplegic patients due to stroke on temporal and spatial gait ability. Design: Randomized sham controlled trial. Methods: For the study method, 42 patients with hemiplegia due to stroke were randomly assigned to 14 patients each, and the general walking group, tDCS walking group, and tDCS (sham) walking group were subjected to 5 times a week, 30 minutes a day, and 6 weeks. In the temporal gait variables of hemiplegic patients due to stroke, the effect of the gait time, gait cycle, single support, double support, swing phase, stance phase, gait speed, cadence were measured. In spatial variables, one step length and one step length were measured. Results: As a result of the study, the EG group significantly increased in the step time, gait velocity, and cadence of the paralysis side in the comparison of temporal walking variables between groups according to the application of tDCS of walking ability in hemiplegic patients due to stroke patients(p<.05). In the change in spatial walking variables between groups according to the application of tDCS, the step length and stride length of the EG group showed a significant increase. Both the comparison of temporal and spatial symmetry walking variables between groups according to tDCS application was not significant(p>.05) Conclusion: As a result, tDCS has an effective effect on the improvement of the gait ability of stroke patients. In particular, it is an effective method of physical therapy that can improve the cadence and speed of gait, which can be combined with the existing gait training to effectively increase the gait of hemiplegia due to stroke patients.

Preliminary Study of Ambulation Training on Electromechanical Gait Trainer in Stroke Patients (전동식 보행 훈련기를 이용한 뇌졸중 환자 보행훈련의 사전연구)

  • Kim, Jae-Hyun;An, Seung-Huon;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • Purpose : The purpose of this study was to investigate the effect of electromechanical gait trainer therapy in stroke patients. The gait trainer was designed to provide nonambulatory subjects the repetitive practice of a gait-like movement without overstraining therapist. To simulate normal gait, discrete stance and swing phase, lasting 60% and 40% of the gait cycle respectively, and the control of the movement of the centre of mass were required. Methods : This preliminary study investigated during 8 weeks therapy on the gait trainer could improve gait ability in 5 subacute and chronic hemiparetic stroke patients. Gait ability(time up & go [TUG], comfortable and maximal gait speed and functional ambulation category[FAC]), functional movement of lower extremity(Fugl-Meyer Assessment [FMA] and composite spasticity score [CSS]) and sensory of lower extremity(Fugl-Meyer Assessment sensory [FMA-s])were the measured. Results : TUG, comfortable and maximal gait speed and FMA were improved significantly. Although FAC, FMA-s and CSS were improved, there were not statistically significant. Conclusion : Therefore, the gait trainer enabled affected patients the repetitive practice of a gait-like movement, which is important for the restoration of walking ability.

  • PDF

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.3
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

Characteristics of Vertical Acceleration at Center of Mass of the Body in Normal Gait (정상보행시 체중심의 수직 가속도 특성)

  • Yi, Jin-Bock;Kang, Sung-Jae;Kim, Young-Ho
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.39-46
    • /
    • 2002
  • In this study, vertical acceleration of center of mass was observed along normal gait phases in 9 healthy male volunteers (aged $25.7{\pm}2.18$). The developed wireless accelerometric device was attached on the intervertebral space between L3 and L4 using a semi-elastic waist belt. A three-dimensional motion analysis system, synchronized with the accelerometry, was used for detecting gait phases. There was no significant correlation between the body weight and the acceleration. The first peak curve covered loading response phase. The second downward peak point was matched accurately with the opposite toe-off. In mid-stance and terminal stance, the acceleration curve highly resembled the vertical ground reaction force curve. There was no significant difference in timing between the final upward peak point and the initial contact. Therefore, the developed accelerometry system would be helpful in determining determine temporal gait pattems in patients with gait disorders.

  • PDF

Portable Gait-Event Detection System for FES Locomotion (FES 보행을 위한 휴대용 보행 이벤트 검출 시스템)

  • Kong, Se-Jin;Kim, Chul-Seung;Park, Kwan-Yong;Eom, Gwang-Moon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.5
    • /
    • pp.248-253
    • /
    • 2006
  • The purpose of this study is to develop a portable gait-event detection system which is necessary for the cycle-to-cycle FES(functional electrical stimulation) control of locomotion. To make the system portable, we made following modifications in the gait signal measurement system. That is, 1) to make the system wireless using Bluetooth communication, 2) to make the system small-sized and battery-powered by using low power consumption ${\mu}$ P(ATmega8535L). The gait-events were analyzed in off-line at the main computer using ANN(Artificial Neural Network). The Proposed system showed no mis-detection of the gait-events of normal subject and hemiplegia subjects. The performance of the system was better than the previous wired-system.