• 제목/요약/키워드: Gage

검색결과 563건 처리시간 0.023초

경락노선상 임피던스 측정기(MIR-2)의 측정신뢰도 개선방안 연구 (Improvement of the repeatability and reproducibility of the meridian impedance measurement system MIR-2)

  • 인창식;이혜정;김종열;이우철
    • Korean Journal of Acupuncture
    • /
    • 제24권4호
    • /
    • pp.55-67
    • /
    • 2007
  • Objectives : The repeatability and reproducibility of MIR-2, a newly developed impedance measurement device (four electrode method) on skin are of the meridian system, is evaluated and a method to improve the reliability is discussed. Methods : Multiple gage R&R studies were conducted for the impedance measurements over bilateral KI3 acupoint in ten participants by three assessors using MIR-2 device. Gage R&R studies were repeated after controlling the acupoint locating method or one value correction by replacing one assessor's outlying value with an average of the other assessors' values to explore any feasibility of improvement of measurement reliability. Results : Controlling acupoint locating method and replacing one value with an average of other assessors' value led to improved variation metrics in a gage R&R study. Conclusions : Measurement reliability can be improved by controlling measurement procedures or by using repeated measurement method, which will facilitate development of clinically applicable measurement device with reliability.

  • PDF

2024-T3 A1 합금의 이방성이 피로균열진전속도와 정류거동에 미치는 영향 (Effect of Anisotropy on Fatigue Crack Propagation Rate and Arrest Behavior with 2024-T3 Alumunum Alloy)

  • 오세욱;김태형;오정종
    • 한국해양공학회지
    • /
    • 제7권1호
    • /
    • pp.124-132
    • /
    • 1993
  • In order to examine the effect of anisotropy and stress ratio on fatigue crack propagation rate and opening-closing behavior and also arrest behavior by single tension peak overload, the fatigue tests of constant amplitude atress and single tension peak overload adding to cycle of constant amplitude were carried out in stress ratio of -0.4, -0.2, and 0.4 with materials of T-L and L-T directions in 2024-T3 aluminum alloy plate. Crack opening-closing begavior were measured by the compliance method using COD gage and strain gage. In case of the crack opening-closing behavior was measured by strain gage, the effect of stress ratio is unchangeable. But in the case of COD gage, that is remarkably decreased. Fictitious effective stress intensity factor(U sub(f)) and effective stress intensity factor ratio(U) in L-T direction was higher than those in T-L direction and also threshold arrest overload ratio incrased as stress ratio decreased and that of T-L direction was higher than that in L-T direction.

  • PDF

복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study- (Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study -)

  • 남동현
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

게이지 R&R과 성능지수를 이용한 측정시스템과 공정능력 평가 방법 (Evaluation Method for Measurement System and Process Capability Using Gage R&R and Performance Indices)

  • 주영돈;이동주
    • 산업경영시스템학회지
    • /
    • 제42권2호
    • /
    • pp.78-85
    • /
    • 2019
  • High variance observed in the measurement system can cause high process variation that can affect process capability badly. Therefore, measurement system analysis is closely related to process capability analysis. Generally, the evaluation for measurement system and process variance is performed separately in the industry. That is, the measurement system analysis is implemented before process monitoring, process capability and process performance analysis even though these analyses are closely related. This paper presents the effective concurrent evaluation procedure for measurement system analysis and process capability analysis using the table that contains Process Performance (Pp), Gage Repeatability & Reproducibility (%R&R) and Number of Distinct Categories (NDC). Furthermore, the long-term process capability index (Pp), which takes into account both gage variance and process variance, is used instead of the short-term process capability (Cp) considering only process variance. The long-term capability index can reflect well the relationship between the measurement system and process capability. The quality measurement and improvement guidelines by region scale are also described in detail. In conclusion, this research proposes the procedure that can execute the measurement system analysis and process capability analysis at the same time. The proposed procedure can contribute to reduction of the measurement staff's effort and to improvement of accurate evaluation.

스트레인게이지법을 사용한 그라스세라믹의 동적 파괴특성평가 (Evaluation of dynamic fracture characteristics for advanced glass ceramics using strain gage method)

  • 노남수;김재훈;이영신;김덕회;문순일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.112-115
    • /
    • 2005
  • 본 연구는 램제트 엔진의 돔포트 커버의 소재로 사용 될 첨단 그라스 세라믹(MACOR) 소재에 대한 동적 파괴인성 시험을 목적으로 한다. 다양한 노치반경의 시험편에 대하여 스트레인게이지법을 사용한 정적과 동적 파괴인성 시험을 수행하였다.

  • PDF

레이저 간섭장치를 이용한 높이마이크로미터 교정장치의 개발 (Development of height micrometer calibration system by using laser interferometer)

  • 엄태봉;양상희;우인후;임재선;정명세
    • 한국정밀공학회지
    • /
    • 제5권3호
    • /
    • pp.43-47
    • /
    • 1988
  • Height micrometer is a kind of end standards. It consists of a stack of gage blocks which is capable of moving up and down by a micrometer head. Height micrometer requires calibration with very high accuracy because its resolution is generally 1 .mu. m and its accuracy is higher than few micro- meters. Conventionally, comparison with gage blocks is used to calibrate height micrometer, but it is less accurate and time consuming method. A height micrometer calibration system using a laser interferometer instead of gage blocks has been developed. The measuring range of the system is 300mm, and the accuracy is better than ${\pm}0.5{\mu}m$ A new method of maintaining the laser-beam alignment is described as well.

  • PDF

HCF용 스트럿의 개선을 위한 연구 - Motorized Strut & Digital Gage (A Study on the Improvement of the Strut for the HCF - Motorized Strut & Digital Gage)

  • 심형준;한창수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.263-268
    • /
    • 2001
  • Two ways of improvement of the strut for the HCF was made in this paper. The strut for the existing HCF is a passive link, which results the posture of the HCF and related bones. The accuracy of the HCF depends on the accuracy of the strut length. A "digital gage" was proposed to increase the accuracy of the strut by presenting the measuring result as figures in manual mode operation. And a "motorized strut system" was designed for the automated HCF operation. A strut was equipped with a motor, "motorized strut" can be operated manually and automatically. In automatic mode, the HCF operating data is generated by the HCF schedule package in PC and is downloaded to the "motorized strut system" controller. By these two improvements, changes in orthopedic equipments like HCF and other Ilizarov fixators are expected.

  • PDF

도플러방식과 헤테로다인 방식의 광간섭법을 병용한 절대높이 측정 정밀도 향상 (Improvement of Measurement Accuracy for Absolute Height by Using Two Types of Doppler and Heterodyne Optical Interferometry)

  • 안근식;장경영;문희관
    • 한국정밀공학회지
    • /
    • 제13권6호
    • /
    • pp.128-135
    • /
    • 1996
  • This paper proposes a high precision measurement technique to obtain the height of gage block with a few millimeter height. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, in the second step, heterodyne laser interferometry is adopted to acquire the precision value. A new kind of phase detector is constructed in the low cost for the heterodyne interferometer and its linearity with ${\pm}1%$ is confirmed by experiment. Also measurement error factors due to enviroments are discussed and methodology to reduce such errors is proposed. Preliminary experiments are carried out for the gage blocks of as high as a few millimeter.

  • PDF

Strain Gaged와 A/D 변환기를 이용한 하중, 변형률 측정장치 제작 (Design and Assembling of Load and Strain Measuring Equipment using Strain Gage and A/D Converter)

  • 박태근;양민복;백태현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.293-294
    • /
    • 2006
  • The conventional strain measuring device is costly and complicated - it is not simple to understand its structure. Hence, strain gage and the A/D converter are assembled to come up with a load and a strain measuring device. The device was tested for measuring the strain in a loaded specimen and the experimental results were compared to those obtained by a commercial strain indicator.

  • PDF

측정 시스템 분석 모형의 고찰 및 새로운 모형의 제안 (Review and Suggestions of Models for Measurement System Analysis)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제10권1호
    • /
    • pp.191-195
    • /
    • 2008
  • The present study contributes reviewing and suggesting various models for measurement system analysis (MSA). Measurement errors consist of accuracy, linearity, stability, part precision, repeatability and reproducibility (R&R). First, the major content presents split-plot design, and the combination method of crossed and nested design for obtaining gage R&R. Second, we propose $\bar{x}-s$ variable control chart for calculating the gage R&R and number of distinct category. Lastly, investigating the determination of gage performance curve which establishes the control specification propagating calibration uncertainties and measurement errors is described.