• Title/Summary/Keyword: GUM(Guide to the expression of Uncertainty in Measurement)

Search Result 28, Processing Time 0.026 seconds

Uncertainty of Peroxide Value Determination in Fat in Follow up Formula (성장기용 조제식에 함유된 유지성분의 과산화물가 측정불확도)

  • Kim, Sung-Han;Kwack, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.885-892
    • /
    • 2004
  • Peroxide values (PV) of fat from fallow up formula were determined using redox-potentiometric titration method and standard method, which is based on KI oxidation by hydroperoxides and volumetric titration of liberated iodine, and their uncertainties were compared. Uncertainty sources in measurement, such as sample weight, sodium thiosulfate concentration, and titer, were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement and Draft EURACHEM/CITAC Guide. Analytical results and combined standard uncertainties of peroxide values (PV) determined by standard burette and potentiometric titrations were $2.05{\pm}0.17\;and\;1.96{\pm}0.07\;meq/kg$, respectively, suggesting potentiometric titration method is suitable for determining PV of fat with low PV, because uncertainty of PV determination obtained by potentiometric titration was lower than that obtained by burette titration.

Measurement Uncertainty Analysis of Performance Test for Coordinate Measuring Machine (3차원 좌표 측정기 성능 시험법에 대한 측정 불확도 해석)

  • Lee, Seung-Pyo;Kang, Hyung-Joo;Ha, Sung-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.91-99
    • /
    • 2009
  • Because of both precise measurement and efficient quality control, coordinate measuring machines(CMMs) have been widely used in the industry. The purpose of this paper is to present a method to estimate the CMM measurement uncertainty using design of experiments. A factorial design is applied to carry out the performance test proposed by ISO 10360 and to investigate CMM measurement errors associated to orientation and length of the length bar. In order to assess the measurement uncertainty for the performance test, an analysis of the uncertainty components that make up the uncertainty budget has been carried out. The procedure for evaluating the uncertainty of it follows GUM ("Guide to the expression of uncertainty in measurement"). The results show that the proposed method is suitable to investigate CMM performance and determine the contribution of machine variables to measurement uncertainty.

Error factors and uncertainty measurement for determinations of amino acid in beef bone extract (사골농축액 시료 중에 함유된 아미노산 정량분석에 대한 오차 요인 및 측정불확도 추정)

  • Kim, Young-Jun;Kim, Ji-Young;Jung, Min-Yu;Shin, Young-Jae
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.125-134
    • /
    • 2013
  • This study was demonstrated to estimate the measurement uncertainty of 23 multiple-component amino acids from beef bone extract by high performance liquid chromatography (HPLC). The sources of measurement uncertainty (i.e. sample weight, final volume, standard weight, purity, standard solution, calibration curve, recovery and repeatability) in associated with the analysis of amino acids were evaluated. The estimation of uncertainty obtained on the GUM (Guide to the expression of uncertainty in measurement) and EURACHEM document with mathematical calculation and statistical analysis. The content of total amino acids from beef bone extract was 36.18 g/100 g and the expanded uncertainty by multiplying coverage factor (k, 2.05~2.36) was 3.81 g/100 g at a 95% confidence level. The major contributors to the measurement uncertainty were identified in the order of recovery and repeatability (25.2%), sample pretreatment (24.5%), calibration-curve (24.0%) and weight of the reference material (10.4%). Therefore, more careful experiments are required in these steps to reduce uncertainties of amino acids analysis with a better personal proficiency improvement.

Uncertainty Quantification of Thermophysical Property Measurement in Space and on Earth: A Study of Liquid Platinum Using Electrostatic Levitation

  • Jannatun Nawer;Takehiko Ishikawa;Hirohisa Oda;Chihiro Koyama;Douglas M. Matson
    • Journal of Astronomy and Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.93-100
    • /
    • 2023
  • A study of uncertainty analysis was conducted on four key thermophysical properties of molten Platinum using a noncontacting levitation technique. More specifically, this work demonstrates a detailed reporting of the uncertainties associated with the density, volumetric thermal expansion coefficient, surface tension and viscosity measurements at higher temperatures for a widely used refractory metal, Platinum using electrostatic levitation (ESL). The microgravity experiments were conducted using JAXA's Electrostatic Levitation Furnace (ELF) facility on the International Space Station and the terrestrial experiments were conducted using NASA's Marshal Space Flight Center's ESL facility. The performance of these two facilities were then quantified based on the measurement precision and accuracy using the metrological International Standards Organization's Guide to the Expression of Uncertainty Measurement (GUM) principles.

Estimation of Measurement Uncertainty in Vitamin C Analysis from Vegetable and Fruit Juice (야채음료 중 비타민 C 분석에 있어서의 측정불확도 추정)

  • Kim, Young-Jun;Kim, Hyeon-Wee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1053-1059
    • /
    • 2003
  • This study aimed to determine the amount of vitamin C from vegetable & fruit juice by high performance liquid chromatograhy (HPLC). Components for estimation of measurement uncertainty associated with the analysis of vitamin C, such as standard weight, purity, molecular weight, dilution of standard solution, calibration curve, recovery, and precision, were importantly applied. The estimation of uncertainty obtained with systematic and random error based on the GUM (Guide to the expression of uncertainty in measurement) and EURACHEM document with mathematical calculation and statistical analysis. The components, evaluated ty either Type A or Type B methods, were combined to produce an overall value of uncertainty known as the combined standard uncertainty. An expanded uncertainty was obtained by multiplying the combined standard uncertainty with a coverage factor (k) calculated from the effective degree of freedom. The content of vitamin C from vegetable and fruit juice was 27.53 mg/100g and the expanded uncertainty by multiplying by the coverage factor (k, 2.06) was 0.63 mg/100g at a 95% confidence level. It was concluded that the main sources were, in order of recovery and precision, weight and purity of the reference material, dilution of the standard solution, and calibration curve. Careful experiments on other higher uncertainties is further needed in addition to better personal proficiency in sample analysis in terms of accuracy and precision.

Pitch Measurement of 150 nm 1D-grating Standards Using an Nano-metrological Atomic Force Microscope

  • Jonghan Jin;Ichiko Misumi;Satoshi Gonda;Tomizo Kurosawa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.3
    • /
    • pp.19-25
    • /
    • 2004
  • Pitch measurements of 150 nm one-dimensional grating standards were carried out using a contact mode atomic force microscopy with a high resolution three-axis laser interferometer. This measurement technique was named as the 'nano-metrological AFM'. In the nano-metrological AFM, three laser interferometers were aligned precisely to the end of an AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$ stabilized He-Ne laser at a wavelength of 633 nm. Therefore, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM could be used to directly measure the length standard. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). The primary source of uncertainty in the pitch-measurements was derived from the repeatability of the pitch-measurements, and its value was about 0.186 nm. The average pitch value was 146.65 nm and the combined standard uncertainty was less than 0.262 nm. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

Uncertainty Study of Added Resistance Experiment (부가저항 실험의 불확실성 연구)

  • Park, Dong-Min;Lee, Jaehoon;Kim, Yonghwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.5
    • /
    • pp.396-408
    • /
    • 2014
  • In this study, uncertainty analysis based on ITTC(International Towing Tank Conference) Recommended Procedures is carried out in the towing-tank experiment for motion responses and added resistance. The experiment was conducted for KVLCC2 model in head sea condition. The heave, pitch and added resistance were measured in different wave conditions, and the measurement was repeated up to maximum 15 times in each wave condition in order to observe the uncertainty of measured data. The uncertainty analysis was carried out by adopting the ISO-GUM(International Organization for Standardization, Guide to the Expression of Uncertainty in Measurements) method recommended by ITTC. This paper describes the details about the analysis method, uncertainty and the measured uncertainty for each source. The uncertainty analysis results are summarized as a tabular form. To validate the accuracy of the present measurement, the experimental results are compared with the results of numerical computation and other experiment. From the present uncertainty analysis, the main sources of uncertainty are identified, which can be very useful to improve the accuracy for added resistance experiment.

150 nm Pitch Measurement using Metrological AFM (길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정)

  • ;I. Misumi;S. Gonda;T. Kurosawa
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters (2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구)

  • Choi Jong Oh;Lee Woan Kyu;Lim Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

A Study on the Development and the Uncertainty Analysis of Oil Flow Standard System (기름 유량표준장치의 개발 및 측정 불확도에 관한 연구)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1071-1080
    • /
    • 2003
  • A national standard system was developed in order to calibrate and test the oil flowmeters for the petroleum field. A stop valve and a gyroscopic weighing scale were employed for the primary standard of the flow quantity. It is operated by the standing start and finish mode and the static weighing method. The model equation for uncertainty evaluation was based on the calibration principle of standard system. The sources of the uncertainties were quantified and combined according to the GUM(Guide to the Expression of Uncertainty in Measurement). It was found that the standard system had the relative expanded uncertainty of 0.04 % in the range of 18 - 350 ㎥/h. According to the uncertainty budget, the uncertainties of the fluid density and the volume of pipeline, which were temperature dependent, contributed 92% of final uncertainty in the oil flow standard system.