• Title/Summary/Keyword: GTV

Search Result 59, Processing Time 0.023 seconds

Simultaneous Modulated Accelerated Radiation Therapy and Concurrent Weekly Paclitaxel in the Treatment of Locally Advanced Nasopharyngeal Carcinoma

  • Xie, Cong-Ying;Jin, Xian-Ce;Deng, Xia;Xue, Sheng-Liu;Jing, Zhao;Su, Hua-Fang;Wu, Shi-Xiu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6129-6132
    • /
    • 2012
  • Objectives: To evaluate the feasibility and efficacy of simultaneous accelerated radiation therapy (SMART) and concurrent weekly paclitaxel in the treatment of locally advanced nasopharyngeal carcinoma. Methods: Forty-one patients with pathologically confirmed nasopharyngeal carcinoma were treated by SMART with concurrent weekly paclitaxel. Daily fraction doses of 2.5 Gy and 2.0 Gy were prescribed to the gross tumor volume (GTV) and clinical target volume (CTV) to a total dose of 70 Gy and 56 Gy, respectively. Paclitaxel of $45mg/m^2$ was administered concurrently with radiation therapy every week. Adjuvant chemotherapy was given four weeks after the completion of the radiotherapy (RT) if the tumor demonstrated only a partial response (PR). Results: All patients completed the radiotherapy (RT) course. Adjuvant chemotherapy was administered to 12 patients due to PR. The CR (complete remission) rate was 82.9% three months after RT. Thirty-nine (95.1%) patients completed the concurrent weekly chemotherapy with paclitaxel, and two patients skipped their sixth course. Seven patients had a 15% dosage reduction at the fifth and sixth course due to grade 3 mucositis. The median follow-up was 30 (range, 14-42) months. The three-year overall survival (OS), metastases-free survival (MFS), and local control rates were 77.0%, 64.4%, and 97.6%, respectively. No correlation between survival rate and T or N stage was observed. Grade 3 acute mucositis and xerostomia were present in 17.1% and 7.1%, respectively. Conclusion: SMART with concurrent weekly paclitaxel is a potentially effective and toxicity tolerable approach in the treatment of locally advanced NPC.

Spect-guidance to Reduce Radioactive Dose to Functioning Lung for Stage III Non-small Cell Lung Cancer

  • Wang, Zhong-Tang;Wei, Li-Li;Ding, Xiu-Ping;Sun, Ming-Ping;Sun, Hong-Fu;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1061-1065
    • /
    • 2013
  • Objective: To investigate the treatment effect of additional information obtained by single photon emission computed tomography (SPECT) lung perfusion imaging (LPI) in the radiotherapy planning process for patients with stage III non-small cell lung cancer (NSCLC). Methods: 39 patients with stage III NSCLC were enrolled. Gross tumor volume (GTV) was outlined by SPECT/CT images, SPECT-LPIs being used to define functional lung (FL) and non-functional lung (NFL) regions. Two sets of IMRT plans were designed to deliver 64Gy to PTV. One was a regular IMRT plan using CT images only (Plan 1), and the other was a corresponding IMRT plan using co-registered images (Plan 2). $FL_{Vx}$ (the % volume of functional lung receiving ${\geq}$x Gy) and $WL_{Vx}$ (% volume of whole lung to receive ${\geq}$x Gy) were compared by paired Student's t test. Kendalls correlation was used to analyze the factor (s) related with the FLV20 decrease. Results: Compared with plan 1, both $WL_{Vx}$ and $FL_{Vx}$ were decreased in plan 2. $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V30}$ and $WL_{V35}$ decreased 9.7%, 13.8%, 17.2%, 12.9%, 9.8% and 9.8%, and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ and $FL_{V35}$ decreased 10.8%, 14.6%, 17.3%, 14.5%, 14.5% and 10.5%. $FL_{Vx}$ decreased significantly compared with $WL_{Vx}$. There were significant differences in $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V3}$ and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ between plan 1 and plan 2 (P=0.002, 0.000, 0.000, 0.005, 0.027 and 0.002, 0.000, 0.000, 0.006, 0.010). According to Kendall correlation analysis, NFL had a negative relation with the percentage FLV20 decrease (r=-0.559, P<0.01), while the distance of PTV and NFL center had a significantly positive relation with the percentage of FLV20 decrease (r=0.768, P<0.01). Conclusion: Routine use of SPECT-LPI for patients undergoing radiotherapy planning for stage III NSCLC appears warranted.

The Objective Measurement of the Lung Parenchyma Motion for Planning Target Volume Delineation (폐 부위 Planning Target Volume(PTV)설정시 폐 움직임의 객관적 측정)

  • Chung, Weon-Kyu;Cho, Jeong-Gill
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.387-392
    • /
    • 1997
  • Purpose : To quantify the movement of lung Parenchyma for ICRU 50 Planning Target Volume (PTV) delineation of the lung region. Materials and Method : Fluoroscopic observations and measurements are Performed on 10 patients with chest region cancer who have normal putmonary functions We have divided the lung region into 12 parts for the right lung, 10 parts for the left lung and four to five Points of lung parenchyma were selected for anatomical analysis Points, Fluoroscopic images are sent to a computer and then movements are measured. Results : Both lowe lobes showed the longest longitudinal movements because of breathing (average 14.1mm, maximum 22.1mm), while anteroposterior displacement showed the smallest value. Lateral movements of the lung parenchyma averaged 6.6mm, and the maximum value was 9.1mm, (both hilar regions showed maximum values because of cardiac motion) Conclusion : We could quantify the lung movements by measuring parenchyma displacements. The movements of both upper lobes were less than those of the middle and upper lobes in longitudinal and transverse movements. Optimal margins can be selected for PTV delineation using these results.

  • PDF

Radiation Dose-escalation Trial for Glioblastomas with 3D-conformal Radiotherapy (3차원 입체조형치료에 의한 아교모세포종의 방사선 선량증가 연구)

  • Cho, Jae-Ho;Lee, Chang-Geol;Kim, Kyoung-Ju;Bak, Jin-Ho;Lee, Se-Byeoung;Cho, Sam-Ju;Shim, Su-Jung;Yoon, Dok-Hyun;Chang, Jong-Hee;Kim, Tae-Gon;Kim, Dong-Suk;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.237-246
    • /
    • 2004
  • Purpose: To investigate the effects of radiation dose-escalation on the treatment outcome, complications and the other prognostic variables for glioblastoma patients treated with 3D-conformal radiotherapy (3D-CRT). Materials and Methods: Between Jan 1997 and July 2002, a total of 75 patients with histologically proven diagnosis of glioblastoma were analyzed. The patients who had a Karnofsky Performance Score (KPS) of 60 or higher, and received at least 50 Gy of radiation to the tumor bed were eligible. All the patients were divided into two arms; Arm 1, the high-dose group was enrolled prospectively, and Arm 2, the low-dose group served as a retrospective control. Arm 1 patients received $63\~70$ Gy (Median 66 Gy, fraction size $1.8\~2$ Gy) with 3D-conformal radiotherapy, and Arm 2 received 59.4 Gy or less (Median 59.4 Gy, fraction size 1.8 Gy) with 2D-conventional radiotherapy. The Gross Tumor Volume (GTV) was defined by the surgical margin and the residual gross tumor on a contrast enhanced MRI. Surrounding edema was not included in the Clinical Target Volume (CTV) in Arm 1, so as to reduce the risk of late radiation associated complications; whereas as in Arm 2 it was included. The overall survival and progression free survival times were calculated from the date of surgery using the Kaplan-Meier method. The time to progression was measured with serial neurologic examinations and MRI or CT scans after RT completion. Acute and late toxicities were evaluated using the Radiation Therapy Oncology Group neurotoxicity scores. Results: During the relatively short follow up period of 14 months, the median overall survival and progression free survival times were $15{\pm}1.65$ and $11{\pm}0.95$ months, respectively. The was a significantly longer survival time for the Arm 1 patients compared to those in Arm 2 (p=0.028). For Arm 1 patients, the median survival and progression free survival times were $21{\pm}5.03$ and $12{\pm}1.59$ months, respectively, while for Arm 2 patients they were $14{\pm}0.94$ and $10{\pm}1.63$ months, respectively. Especially in terms of the 2-year survival rate, the high-dose group showed a much better survival time than the low-dose group; $44.7\%$ versus $19.2\%$. Upon univariate analyses, age, performance status, location of tumor, extent of surgery, tumor volume and radiation dose group were significant factors for survival. Multivariate analyses confirmed that the impact of radiation dose on survival was independent of age, performance status, extent of surgery and target volume. During the follow-up period, complications related directly with radiation, such as radionecrosis, has not been identified. Conclusion: Using 3D-conformal radiotherapy, which is able to reduce the radiation dose to normal tissues compared to 2D-conventional treatment, up to 70 Gy of radiation could be delivered to the GTV without significant toxicity. As an approach to intensify local treatment, the radiation dose escalation through 3D-CRT can be expected to increase the overall and progression free survival times for patients with glioblastomas.

Evaluation of the Efficiency of the Foxtail Millet Vacuum Cushion in Skin Cancer Radiation Treatment (자체 제작한 Foxtail Millet Vacuum Cushion의 광자선 피부암 치료 시 유용성 검증)

  • Choi, Shin-Cheol;Lee, Kyung-Jae;Jung, Sung-Min;Oh, Tae-Seong;Park, Jong-Il;Shin, Hyun-Kyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2012
  • Purpose: The sufficiency of skin dose and the reemergence of patient set-up position to the success of skin cancer radiation treatment is a very important element. But the conventional methods to increase the skin dose were used to vacuum cushion, bolus and water tank have several weak points. For this reason, we producted Foxtail Millet Vacuum Cushion and evaluated the efficiency of the Foxtail Millet Vacuum Cushion in skin cancer Radiation treatment. Materials and Methods: We measured absolute dose for 3 materials (Foxtail Millet Vacuum Cushion, bolus and solid water phantom) and compared each dose distribution. We irradiated 6 MV 100 MU photon radiation to every material of 1 cm, 2 cm, 3 cm thickness at three times. We measured absolute dose and compared dose distribution. Finally we inspected the CT simulation and radiation therapy planing using the Foxtail Millet Vacuum Cushion. Results: Absolute dose of Foxtail Millet Vacuum Cushion was similar to absolute dose of bolus and solid water phantom's result in each thickness. it Showed only the difference of 0.1~0.2% between each material. Also the same result in dose distribution comparison. About 97% of the dose distribution was within the margin of error in the prescribed ranges ($100{\pm}3%$), and achieved the enough skin dose (Gross Tumor Volume dose : $100{\pm}5%$) in radiation therapy planing. Conclusion: We evaluated important fact that Foxtail Millet Vacuum Cushion is no shortage of time to replace the soft tissue equivalent material and normal vacuum cushion at the low energy radiation transmittance. Foxtail Millet Vacuum Cushion can simultaneously achieve the enough skin dose in radiation therapy planing with maintaining normal vacuum cushion' function. Therefore as above We think that Foxtail Millet Vacuum Cushion is very useful in skin cancer radiation treatment.

  • PDF

Rectal Balloon for the Immobilization of the Prostate Internal Motion (전립선암의 방사선치료 시 직장풍선의 유용성 평가)

  • Lee Sang-Kyu;Beak Jong-Geal;Kim Joo-Ho;Jeon Byong-Chul;Cho Jeong-Hee;Kim Dong-Wook;Na Soo-Kyong;Song Tae-Soo;Cho Jae-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.113-124
    • /
    • 2005
  • Purpose : The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. Materials and Methods : In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning samely repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal ballon position and verified the isodose distribution of rectum wall at closed prostate. Results : Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. Conclusion : The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficients for treated prostate cancer patients.

  • PDF

Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site (간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교)

  • Park, Byung-Do;Jung, Sang-Hoon;Park, Sung-Ho;Kwak, Jeong-Won;Kim, Jong-Hoon;Yoon, Sang-Min;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • The purpose of this study is to evaluate the variation of radiation dose distribution for liver tumor located in liver dome and for the interest organs(normal liver, kidney, stomach) with the pencil beam convolution (PBC) algorithm versus anisotropic Analyticalal algorithm (AAA) of the Varian Eclipse treatment planning system, The target volumes from 20 liver cancer patients were used to create treatment plans. Treatment plans for 10 patients were performed in Stereotactic Body Radiation Therapy (SBRT) plan and others were performed in 3 Dimensional Conformal Radiation Therapy (3DCRT) plan. dose calculation was recalculated by AAA algorithm after dose calculation was performed by PBC algorithm for 20 patients. Plans were optimized to 100% of the PTV by the Prescription Isodose in Dose Calculation with the PBC algorithm. Plans were recalculated with the AAA, retaining identical beam arrangements, monitor units, field weighting and collimator condition. In this study, Total PTV was to be statistically significant (SRS: p=0.018, 3DCRT: p=0.006) between PBC and AAA algorithm. and in the case of PTV, ITV in liver dome, plans for 3DCRT were to be statistically significant respectively (p=0.013, p=0.024). normal liver and kidney were to be statistically significant (p=0.009, p=0.037). For the predictive index of dose variation, CVF ratio was to be statistically significant for PTV in the liver dome versus PTV (SRS r=0.684, 3DCRT r=0.732, p<0.01) and CVF ratio for Tumor size was to be statistically significant (SRS r=-0.193, p=0.017, 3DCRT r=0.237, p=0.023).

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

Clinical Experience of Three Dimensional Conformal Radiation Therapy for Non-Small Cell Lung Cancer (비소세포성 폐암에서 3차원 입체조형 방사선 치료 성적)

  • Choi Eun Kyung;Lee Byong Yong;Kang One Chul;Nho Young Ju;Chung Weon Kuu;Ahn Seung Do;Kim Jong Hoon;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.265-274
    • /
    • 1998
  • Purpose : This prospective study has been conducted to assess the value of three dimensional conformal radiation therapy (3DCRT) for lung cancer and to determine its potential advantage over current treatment approaches. Specific aims of this study were to 1) find the most ideal 3DCRT technique 2) establish the maximum tolerance dose that can be delivered with 3DCRT and 3) identify patients at risk for development of radiation pneumonitis. Materials and Methods : Beginning in Nov. 1994, 95 patients with inoperable non-small cell lung cancer (stage I; 4, stage II; 1, stage IIIa; 14, stage IIIb; 76) were entered onto this 3D conformal trial Areas of known disease and elective nodal areas were initially treated to 45 Gy and then using 3DCRT technique 65 to 70 Gy of total dose were delivered to the gross disease. Sixty nine patients received 65 Gy of total dose and 26 received 70 Gy Seventy eight patients (82.1$\%$) also received concurrent MVP chemotherapy. 3DCRT plans were compared with 2D plans to assess the adequacy of dose delivery to target volume, dose volume histograms for normal tissue, and normal tissue complication Probabilities (NTCP). Results : Most of plans (78/95) were composed of non-coplanar multiple (4-8) fields. Coplanar segmented conformal therapy was used in 17 pateints, choosing the proper gantry angle which minimize normal lung exposure in each segment. 3DCRT gave the full dose to nearly 100$\%$ of the gross disease target volume in all patients. The mean NTCP for ipsilateral lung with 3DCRT (range; 0.17-0.43) was 68$\%$ of the mean NTCP with 2D treatment planning (range; 0.27-0.66). DVH analysis for heart showed that irradiated volume of heart could be significantly reduced by non-coplanar 3D approach especially in the case of left lower lobe lesion. Of 95 patients evaluable for response, 75 (79$\%$), showed major response including 25 (26$\%$) with complete responses and 50 (53$\%$) with partial responses. One and two rear overall survivals of stage III patients were 62.6$\%$ and 35.2$\%$ respectively. Twenty percent (19/95) of patients had pneumonitis; Eight patients had grade 1 pneumonitis and 11 other patients had grade 2. Comparison of the average of NTCP for lung showed a significant difference between patients with and without radiation pneumonitis. Average NTCP for Patients without complication was 62$\%$ of those with complications. Conclusions : This study showed that non-coplanar multiple fields (4-8) may be one of the ideal plans for 3DCRT for lung cancer. It also suggested that 3DCRT may provide superior delivery of high dose radiation with reduced risk to normal tissue and that NTCP can be used as a guideline for the dose escalation.

  • PDF