• Title/Summary/Keyword: GS28

Search Result 73, Processing Time 0.032 seconds

Personal Identification Based on Radio Signal Strength for Ubiquitous Healthcare Systems

  • Lee, Jong-Shill;Park, Sang-Hae;Chee, Young-Joon;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.325-331
    • /
    • 2007
  • Personal identification is essential for the automatic measurement of biosignal information in home healthcare systems. Personal identification is usually achieved with passive radio frequency identification (RFID), which does little more than store a unique identification number. However, passive RFID is not ideal for automatic identification. We present a user identification system based on radio signal strength indication (RSSI) using ZigBee for active RFID tags. Personal identification is achieved by finding the largest RSSI value from aggregated beacon messages that are periodically transmitted by active RFID tags carried by users. Obtaining reliable person!'.! identification without restricting the orientation requires a certain distance between the closest active RFID tag from the ZED and the second closest tag. The results show that the closest active RFID tag from the ZED and the second closest tag must be at least 70 cm apart to achieve reliable personal identification.

The effect of negative bias stress stability in high mobility In-Ga-O TFTs

  • Jo, Kwang-Min;Sung, Sang-Yun;You, Jae-Lok;Kim, Se-Yun;Lee, Joon-Hyung;Kim, Jeong-Joo;Heo, Young-Woo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.154-154
    • /
    • 2013
  • In this work, we investigated the characteristics and the effects of light on the negative gate bias stress stability (NBS) in high mobility polycrystalline IGO TFTs. IGO TFT showed a high drain current on/off ratio of ${\sim}10^9$, a field-effect mobility of $114cm^2/Vs$, a threshold voltage of -4V, and a subthresholdslpe(SS) of 0.28V/decade from log($I_{DS}$) vs $V_{GS}$. IGO TFTs showed large negative $V_{TH}$ shift(17V) at light power of $5mW/cm^2$ with negative gate bias stress of -10V for 10000seconds, at a fixed drain voltage ($V_{DS}$) of 0.5V.

  • PDF

The comparative analysis on the distribution of cancers (암환자 분포의 비교 분석)

  • Kim, Seung-Kook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.155-165
    • /
    • 2000
  • This paper is based on the records of researching the patients with cancer in the Chunnam National University Hospital from January 1990 to December 1999 and referred to the Korea Cancer Center Hospital's annual report. The results are as the following : 1. Along the total O.P.D 5,680,284, the patients of therapeutic radiology are 201,367 in $3.55\%$ 2. Among the 12,404 cancer patients, stomach cancer patients are $2,048(16.51\%),\;liver\;cancer\;patients\;are\;1,490(12.01\%),\;lung\;cancer\;patients\;are\;1,418(11.43\%)\;cervix\;and\;uterus\;cancer\;patients\;are\;1,102(8.88\%)$ and sexual ratio of male to female appeared 1.38 : 1 Therefore, male cancer patients are more than female patients. 3. The age distribution of cancer was $2,791(22.50\%)\;by\;55{\sim}64\;age,\;2,582(20.82\%)\;by\;45{\sim}54\;age,\;and\;2,530(20.40\%)\;by\;65{\sim}74\;age.\;Therefore,\;the\;60\%\;of\;all\;cancer\;patients\;were\;45{\sim}75$ ages. 4. Among the 9,815 therapeutic radiology patients, $1,755(17.89\%)\;are\;in\;the\;uterus\;system,\;1,534(15.63\%)\;are\;in\;the\;head\;and\;neck,\;1,519(15.48\%)$ are in the lung. Therefore, the proportion of three kinds of therapeutic radiology patients is about $50\%$. 5. The occupational distributions of 12,404 cancer patients$(90{\sim}99\;year)\;are\;2,795(22.53\%)\;by\;orderly\;farmers,\;2,763(22.28\%)\;by\;house\;wives,\;586(4.71\%)\;by\;businessmen,\;and\;391(3.15\%)$ by public service personnel. Industrial, miners, forest men, soldiers didn't nearly appear. 6. The number of patients of cancer diagnosis was $9,431(76.03\%)\;by\;the\;biopsy\;of\;primary\;region,\;and\;2,201(17.74\%)$ by clinical examination Therefore, those two kinds of methods took a propertion of about $94\%.\;The\;number\;of\;deceases\;on\;departments\;was\;153(32.42\%)\;in\;PD,\;133(28.18\%)\;in\;GI,\;63(13.35\%)$ in GS. Therefore, those three kinds of deceases took a proportion of about $74\%$.

  • PDF

Microbiological Contamination in Office Buildings by Work Space Structure (사무공간 구조에 따른 실내공기 중 생물학적 오염분포 특성)

  • Won, Dong-Hwan;Huh, Eun-Hae;Jeong, Ho-Chul;Moon, Kyong-Whan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.213-222
    • /
    • 2012
  • Objectives: This study was undertaken in order to evaluate by work space zoning and structure the concentrations of biological contaminants in the indoor air of domestic office buildings. Methods: Air samples were collected in the office spaces of 15 office buildings in Seoul from June 28 to July 28, 2011. Prior to the sampling, each office was classified into 'open-plan office', 'cellular office' and 'mixed office' according to the work space zoning. To evaluate the biological contamination of indoor air, total suspended bacteria (TSB), Gram positive bacteria (GPB), Staphylococcus aureus (S.A), Methicillin-resistant Staphylococcus aureus (MRSA), Gram negative bacteria (GNB) and fungi were investigated. During the sampling, temperature, relative humidity and carbon dioxide ($CO_2$) were measured. Results: The TSB concentrations ($GM{\pm}GSD$) were $452({\pm}1.3)cfu/m^3$ in open-plan offices, $366({\pm}1.3)cfu/m^3$ in cellular offices and $287({\pm}1.5)cfu/m^3$ in mixed offices, and there were significant differences between the three groups (p<0.05). The highest concentrations ($GM{\pm}GSD$) of fungi were found in the indoor air of cellular offices $128({\pm}1.0)cfu/m^3$, which was at least three times higher than the concentrations in mixed offices $43({\pm}1.0)cfu/m^3$ (p<0.05). Conclusions: Microbiological contamination in the indoor air of office buildings by work space structure was the highest with the open-plan office layout which includes no high walls or doors separating the occupants.

Identification of Defect Type by Analysis of a Single PD Pulse in Gas Insulated Structure (가스절연 구조에서 단일 부분방전펄스 분석에 의한 결함 판별)

  • Jo, Hyang-Eun;Kim, Sun-Jae;Jeong, Gi-Woo;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.5
    • /
    • pp.320-325
    • /
    • 2015
  • This paper dealt with a defect identification algorithm which is based on single partial discharge (PD) pulse analysis in gas insulated structure. Four types of electrode systems such as a needle-plane, a plane-needle, a free particle and a crack inside spacer were fabricated to simulate defects in gas insulated switchgear (GIS). We measured single PD pulse by an oscilloscope with a sampling rate of 5 GS/s and a frequency bandwidth of 1 GHz. Data aquisition and signal processing were controlled by a LabVIEW program. Physical shapes of PD pulses were compared with kurtosis, skewness and time-based parameters as rising time, falling time and pulse-width. These parameters were analysed by an algorithm with a back propagation algorithm (BPA). By applying the algorithm, the identification rate was 97% for the needle-plane electrode, 96% for the plane-needle electrode, 91% for the free particle and 93% for the crack inside spacer. The results verified that the algorithm could identify the type of defects in GIS.

Sizing of Vertical Borehole Heat Exchangers using TRNOPT (TRNOPT를 이용한 수직 지중열교환기 길이 산정 방법에 관한 연구)

  • Park, Seung-Hoon;Lee, Hyun-Soo;Jang, Young-Sung;Kim, Eui-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.402-407
    • /
    • 2016
  • Ground-coupled heat pump systems have been widely used, as they are regarded as a renewable energy source and ensure a high annual efficiency. Among the system components, borehole heat exchangers (BHE) play an important role in decreasing the entering water temperature (EWT) to heat pumps in the cooling season, and consequently improve the COP. The optimal sizing of the BHEs is crucial for a successful project. Other than the existing sizing methods, a simulation-based design tool is more applicable for modern complex geothermal systems, and it may also be useful since design and engineering works operate on the same platform. A simulation-based sizing method is proposed in this study using the well-known Duct STorage (DST) model in Trnsys. TRNOPT, the Trnsys optimization tool, is used to search for an optimal value of the length of BHEs under given ground loads and ground properties. The result shows that a maximum EWT of BHEs during a design period (10 years) successfully approaches the design EWT while providing an optimal BHE length. Compared to the existing design tool, very similar lengths are calculated by both methods with a small error of 1.07%.

Developments of Advanced Connection Type for Improvements of Mixed Structures (II) (혼합구조의 성능 향상을 위한 개선된 접합부의 개발 (II): 개선된 접합방식의 성능확인을 위한 모형실험 및 해석)

  • Yun, Ik Jung;Lho, Byeong Cheol;Kim, Moon Kyum;Cho, Sung Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.207-214
    • /
    • 2008
  • This study presents a way to validate the quality level of the proposed connection type and verify the experimental test, and performs a 3D nonlinear analysis corresponding to the experimental test. Two mixed-structure beams were cast and tested under a four-point static loading. Force-displacement relation, force-strain relation, force-opening width, and failure mode were observed from comparing the numerical results of the adopted FE model. Nonlinear analysis of mixed structures was carried out by utilizing the contact elements of a general purpose structural analysis computer program (ABAQUS). The results of numerical and experimental simulation show that the proposed L-shaped connection has greater stiffness under flexural loading and better structural performance with regard to the connection.

Estimation of Genetic Parameters for Gestation Length, Wean to First Service, Litter Size and Stillborn Piglets in a Closed Nucleus Swine Breeding Herd (특정 종돈집단의 임신기간, 이유후초종부일, 총산자수 및 사산에 대한 유전모수 추정)

  • Lee, Deukhwan;Son, Jihyun
    • Journal of Animal Science and Technology
    • /
    • v.55 no.5
    • /
    • pp.389-398
    • /
    • 2013
  • This study was conducted to investigate the genetic relationships among four reproductive traits. Data for this study were 7616 records from 1910 Landrace (L) and 10,454 records from 2283 Yorkshire (Y) in a closed nucleus swine herd. Traits considered on this study were gestation length (GL), total number of piglets born (TNB), wean to first service (WFS), and number of stillborn per litter (NSB). Heritabilities and genetic correlations were estimated by using the Bayesian inferences via Gibbs sampling in a four trait linear-threshold repeatability animal mixed model by designating NSB as a categorical trait in the L and Y purebred populations. Effects on the statistical model were considered for parity, contemporary group as fixed and service sire, permanent environmental, animal additive genetic effects as random. Estimates of heritability were 0.21, 0.23, 0.16, and 0.09 for GL, WFS, TNB, and NSB in the L population and 0.35, 0.16, 0.14 and 0.10 for corresponding traits in the Y population, respectively. Genetic correlation for GL was -0.59 and -0.28 with TNB and -0.58 and -0.17 with NSB in the L and Y populations, respectively. The NSB was positively correlated with TNB in the L and Y populations in genetic and environmental aspects. Therefore, the NSB should be taken into account in selecting sows for improving prolificacy of dam line breeding swine stock.

Comparision Between Noise Levels of Hospital Wards and the Nurses Efforts for Noise Management in Selected General Hospital (종합병원 병동별 간호사실의 소음정도와 간호사실들의 소음인지도 및 소음관리노력 비교)

  • Jung, Hyun-Wook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.174-182
    • /
    • 2001
  • This study was performed to find out the differences between noise levels of hospital wards and the nurses efforts for noise management in some general hospitals. The hospital wards selected were the intensive care unit(ICU), the emergency room(ER), the nursery room(NR), the internal medicine(IM), the general surgery(GS) among the 5 general hospitals located in Seoul. The data were collected from August 3 to September 13, 1999 through questionnaire survey and noise measurement in each nursing station of hospital wards. Data analysis was done by SPSS 8.0 package among the 305 questionnaires and 24 hours monitored noise levels. Frequency, Chi-square and ANOVA test were used. The study results were as belows: 1. The noise level measured by 24 hours monitoring survey were exceeded on the standard limit in all the hospital wards. Data also showed that noise levels were significantly different in each ward among the three shifts working duties. 2. The subjects were all female nurses. They were mostly working in the ICU ward(28.9%). They were 26~30 years old (43.9%), junior college graduates(57.0%), working for 1~5 years(55.1%) as staff-nurse(85.6%). There were no significant differences between hospital wards and general characteristics of nurses. 3. The noise levels perceived by nurses were regarded as 'Highly noisy'(56.4%), especially during the 11:30 and 15:30 (30.2%) o'clock. Data also showed that noise education was not ever given to nurses(89.9%). Nurses also responded that they hardly put an effort to reduce noise level(54.8%). However, there were significant differences between wards and noisy working time, experience of noise education and level of effort for noise reduction. 4. Nurses also perceived the ventilator alarm and EKG-alarm as the most disturbing sounds in the ICU, human voice and telephone ringing in the ER, human voice and EKG-alarming in the NR, human voices and telephone ringing in IM and GS both wards respectively in order. There were significant differences between hospital wards and noise making factors. 5. Nurses were shown that they regarded highly 'Sound reduction of the human voice', 'Careful handling on medical instruments', and 'Immediate appliances on alarming materials' as the practical method for noise management. There were significant differences between hospital wards and behavioral practical efforts for noise management. According to that results, the statistical differences were shown in the 24 hour monitored noise levels in each ward. Also, nurses perceived the noise severity differently and they approached variously on the practical efforts for noise reduction in each ward. Thus, author thinks that concrete and systematic endeavor will be necessary for noise reduction and management in hospitals for better working and healing environment for both of patients and staffs.

  • PDF

EFFECT OF POLYPHOSPHATE IN ROOT CANAL SEALERS ON THE GROWTH OF ORAL BACTERIA (Polyphosphate가 함유된 근관충전재가 구강세균의 성장에 미치는 영향)

  • 박석범;최기운;최호영
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.141-152
    • /
    • 2001
  • Eliminating the infecting bacteria of the root canal system and preventing reinfection must be the main objectives of all endodontic works. None of commercially available root canal sealers have the properties of desirable tissue compatibility and strong antibacterial activity. The purpose of this study is to develope an ideal root canal sealer using commercially available polyphosphate (polyP), Calgon, which is known to be antibacterial and safe. For the study. resin type AH26, zinc oxide eugenol type Tubli Seal. Ca(OH)$_2$ type Apexit as base sealers for polyP (0~3%) and para formaldehyde containing N2 as a control base were selected. Specimens (3$\times$4mm) of the sealers were prepared in a 37$^{\circ}C$ incubator for 3 and 10 days and their antibacterial activity against streptococci and black pigmented anaerobic rods was observed using an agar diffusion method. The result were as follows: 1. Among 3 day old root canal sealers. N2 as a positive control showed the strongest antibacterial effect. followed by AH26. Tubli Seal and. Apexit which barely showed antibacterial activity against the test bacteria. In contrast. 10 day old AH26 showed a greater antibacterial activity than 10 day old N2. 2. All sealer specimens showed a greater antibacterial activity against black pigmented anaerobic rods than streptococci. Three day old ones appeared to be more antibacterial than 10 day old ones except for Apexit. 3. As compared to N2, 3 day old AH26 demonstrated a similar antibacterial activity against black pig mented anaerobic rods but to a lesser extent to streptococci. Ten day old AH26 showed a greater antibacterial activity against black pigmented anaerobic rods than 10 day old N2. 4. As compared to AH26. Tubli Seal generally revealed a lower antibacterial activity but it showed a greater antibacterial activity aginst S. gordonii Challis. 5. Enhancement of antibacterial activity by polyP was more clearly observed when it was added to Ca(OH)$^{\circ}C$ based root canal sealers. Tubli Seal and N2. 6. The addition of polyP enhanced the antibacterial activity of 3 day old AH26 against S. gordonii G9B (16%) and Challis (29%), and P. gingivalis 2561 (24%) only. Moreover, polyP failed to increase antibacterial activity of 10 day old AH26 against the test strains but P. gingivalis A7A1 28(13%). 7. The addition of polyP increased the antibacterial effect of 3 day old Tubli Seal on several test bacteria including s. mutans GS 5 (50%). s. gordonii G9B (47%) and Challis (122%). and all the test strains of P. gingivalis (13~35%) except for 9 14K 1. The addition of polyP to 10 day old Tubli Seal increased antibacterial activity of the root canal sealer against most test strains. 8. 3 day old Apexit failed to show antibacterial activity. if any very little against S. mutans GS 5 and Pr. intermedia ATCC 49046. However. polyP increased its antibacterial activity by 50 and 69%, respectively. Increase of antibacterial activity of 10 day old Apexit by polyP was more clearly observed than that of 3 day old one.

  • PDF