• Title/Summary/Keyword: GROUND STATUS

Search Result 483, Processing Time 0.023 seconds

TIME SERIES ANALYSIS OF SPOT NDVI FOR IDENTIFYING IRRIGATION ACTIVITIES AT RICE CULTIVATION AREA IN SUPHANBURI PROVINCE, THAILAND

  • Kamthonkiae Daroonwan;Kiyoshe Honda;Hugh Turral
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.3-6
    • /
    • 2005
  • In this paper, the real scenario of water situation (e.g. water management, water availability and flooding) in an irrigated rice cultivation area in Suphanburi Province, Central-West Thailand is discussed together with the NDVI time series data. The result shown is derived by our classifier named 'Peak Detector Algorithm (PDA)'. The method discriminated 5 classes in terms of irrigation activities and cropping intensities, namely, Non-irrigated, Poorly irrigated - 1 crop/year, Irrigated - 2 crops/year, Irrigated - 3 crops/year and Others (no cultivation happens in a year or other land covers). The overall accuracy of all classified results (1999-2001) is around $77\%$ against independent ground truth data (general activities or function of an area). In the classified results, spatial and temporal inconsistency appeared significantly in the Western and Southern areas of Suphanburi. The inconsistency resulted mainly by anomaly of rainfall pattern in 1999 and their temporal irrigation activity. The algorithm however, was proved that it could detect actual change of irrigation status in a year.

  • PDF

A Study on the Development of a Lightning Warning System by the Measurement of Electric Field at the Ground (용량성 프로브와 광전송회로를 이용한 광대역 전압측정장치)

  • Kil, Gyung-Suk;Song, Jae-Yong;Park, Dae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.363-368
    • /
    • 2004
  • A reliable voltage measurement system is necessary to monitor status of power facilities in substations, which is easy to set up and is not influenced by electromagnetic interference in and around substation. In this paper, we described a voltage measurement system (VMS) which is composed of a capacitive voltage probe, an impedance converter, and an optical linker. To get a wide-band characteristic of the VMS, a high speed impedance converter was used, and the output impedance of the VMS was set at $50{\Omega}$ to match any types of observing instruments. The frequency bandwidth of the VMS. which was estimated by a step pulse, was ranges from 11.42 Hz to 13.65 MHz, and the VMS showed a good response characteristic in a high frequency domain such as impulse voltages as well as a commercial frequency voltage.

Estimation of deformation modulus for rock mass using stress distribution under ground in Large Plate Load Test (대형평판재하시험의 지중응력 측정결과를 이용한 연암의 변형계수 산정)

  • Park, Won-Tae;Lee, Min-Hee;Choi, Yong-Kyu;Kim, Seok-Chan;Kim, Jung-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.539-545
    • /
    • 2010
  • The field plate test has a good potential for determining since it measures both plate pressure and settlement. The deformation modulus of rock mass is differently measured for status of structures. The values of deformation modulus are obtained from laboratory test (uniaxial and triaxial test) and field test (pressuremeter test). Plate load test should be conducted by different loading plate sizes for geological structure of rock mass and scale of structures. In this paper, large plate load tests were performed to predict of structure's behavior and evaluate the ultimate bearing capacity of the foundation on soft rock. Simultaneously, deformation modulus of rock mass was estimated by back analysis of stresses measured in field test under rock mass. Finally, we verified the validation of deformation modulus of rock mass through result of large plate load test and numerical simulation.

  • PDF

Effect of a Sudden Increase in Light Intensity on Normalized Difference Vegetation Index (NDVI) Reflected from Leaves of Tobacco (급격한 광도 변화가 담배 잎에서 반사되는 Normalized Difference Vegetation Index에 미치는 영향)

  • Suh, Kyehong
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.543-547
    • /
    • 2017
  • Normalized Difference Vegetation Index (NDVI) has played an important role in assessing green plant biomass through remote sensing on global scale since the early 1970s. The concept of NDVI is based on the fact that green plants show higher reflection in near-infrared region than in visible region of the electromagnetic spectrum. However, it is well known that the relocation of chloroplasts in plant leaf cells may dramatically change the optical properties of plant leaves. In this study I traced the changes in the reflectance and transmittance properties of Tobacco leaves at the wavelengths of 660 and 800 nm after a sudden increase in light intensity. The results showed that NDVI of leaves gradually decreased from 72.7% to 69.9% when exposed to a sudden increase in light intensity from 30 to $1,200{\mu}mol/m^2{\cdot}s$. This means that the error resulting from the physiological status of the plant should be accounted for a more precise understanding of ground truth corresponding to the data from the remotely acquired images.

The Study of Evaluating The Degree of Consolidation of The Dredged and Reclaimed Soft Ground (준설매립된 연약지반의 압밀도 산정에 관한 연구)

  • Kim, Seung-Tyull;Jung, Hun-Chul;Park, Chi-Myeon;Shin, Kyung-Ha;Jung, Ki-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.469-478
    • /
    • 2005
  • Understanding of an accurate state of consolidation of underconsolidated clay body, like a recently dredged or reclaimed clay deposits, is one of the most difficult tasks. The estimation of the consolidation status of these clay bodies is often made by laboratory tests of numerical analyses. However these methods demonstrated crucial limitations in the accurate prediction. Therefore, the predicted degree of consolidation from various techniques is verified by actual measured field data. The degree of consolidation of clay body in the East Side Hinterland of Gwangyang Port(2nd Phase) is evaluated in this study by using various techniques such as oedometer test, CPTu, numerical analysis and piezometer tests etc. And the results are compared each other to find the most reliable prediction technique. The merit and reliability of each method is discussed in detail. It is revealed from in this study that the estimation of degree of consolidation by an actual pore water pressure measurements is the most reliable technique.

  • PDF

Power System Design for Next Generation LEO Satellite Application (차세대 저궤도 소형위성 적용을 위한 전력시스템 설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jan, Sung-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.283-287
    • /
    • 2005
  • In this paper, one general approach is proposed for the design of power system that can be applicable for next generation LEO satellite application. The power system consists of solar panels, battery, and power control and distribution unit(PCDU). The PCDU contains solar array modules, battery interface modules, low-voltage power distribution modules, high-voltage distribution modules, heater power distribution modules, on-board computer interface modules, and internal DC/DC converter modules. The PCDU plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. We review the functional schemes of the main constitutes of the PCDU such as the battery interface module, the auxiliary supply module, solar array regulators with maximum power point tracking(MPPT) technology, heater power distribution modules, spacecraft unit power distribution modules, and instrument power distribution module.

  • PDF

A Study on Ecological Evaluation of Habitat Suitability Index using GIS - With a case study of Prionailurus bengalensis in Samjang-Sanchung Road Construction - (GIS를 이용한 서식지적합성지수(HSI)의 생태영향평가 활용방안연구 - 삼장-산청 국도건설공사를 사례에서 삵을 중심으로 -)

  • Lee, Sang-Don;Kwon, Ji-Hye;Kim, Ah-Ram;Jung, Ji-Hyang
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.801-811
    • /
    • 2012
  • For biodiversity conservation, Biological Impact Assessment is very important. The focus of the study is to enhance efficient Environment Impact Assessment(EIA) based on collecting existing information of endangered species covering the status survey, estimation of effects and reducing methods. Habitat Suitability Index(HSI) can be applicable to Ecological Impact Assessment and finding various reducing methods based on estimating effects. For this study, the EIA report of Samjang - Sanchung highway construction was chosen as an example and Prionailurus bengalensis euptilura as an endangered species was chosen to assess the ecosystem impact on road construction. Water, road, ground coverage, slope, altitude as variables of habitat were weighted and final HSI map was calculated using Arc map and Arc view. Through comparing of before and after HSI, quantitative estimating on effects was possible to minimize impact of road construction to wildlife habitat.

A Study for the Improvement of the Fault Decision Capability of FRTU using Discrete Wavelet Transform and Neural Network (이산 웨이블릿 변환과 신경회로망을 이용한 FRTU의 고장판단 능력 개선에 관한 연구)

  • Hong, Dae-Seung;Ko, Yoon-Seok;Kang, Tae-Ku;Park, Hak-Yeol;Yim, Hwa-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1183-1190
    • /
    • 2007
  • This paper proposes the improved fault decision algorithm using DWT(Discrete Wavelet Transform) and ANNs for the FRTU(Feeder Remote Terminal Unit) on the feeder in the power distribution system. Generally, the FRTU has the fault decision scheme detecting the phase fault, the ground fault. Especially FRTU has the function for 2000ms. This function doesn't operate FI(Fault Indicator) for the Inrush current generated in switching time. But it has a defect making it impossible for the FI to be operated from the real fault current in inrush restraint time. In such a case, we can not find the fault zone from FI information. Accordingly, the improved fault recognition algorithm is needed to solve this problem. The DWT analysis gives the frequency and time-scale information. The neural network system as a fault recognition was trained to distinguish the inrush current from the fault status by a gradient descent method. In this paper, fault recognition algorithm is improved by using voltage monitoring system, DWT and neural network. All of the data were measured in actual 22.9kV power distribution system.

Development Status of High Enthalpy Plasma Equipment (전북대 고온플라즈마 설비 구축 및 응용연구 소개)

  • Choi, Chea-Hong;Lee, Mi-Yun;Kim, Min-Ho;Hong, Bong-Guen;Seo, Jun-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.694-696
    • /
    • 2011
  • The high enthalpy plasma research center in Chonbuk national university is under construction for four types of plasma equipments. The equipments are 1set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4 MW class enhanced Huels type plasma quipment, 1 set of 60 kW RF plasma equipment and 1 set of 200 kW RF plasma equipment. 60kW RF plasma system is R&D and pilot scale production equipment of nano powder synthesis and plasma spray coating. 200kW RF plasma system is mass production equipment with high power capacity of nano powder synthesis. 0.4MW plasma system can be applied to the ground test facility for material testing under re-entry conditions for space vehicles.

  • PDF

A Study on the Variation of Resistivity of the Unsaturated Sandy Soils Contaminated by Leachate (침출수로 오염된 불포화사질토의 전기비저항 변화에 대한 연구)

  • Yoon, Chun-Gyeong;Yoo, Chan
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.2
    • /
    • pp.112-122
    • /
    • 1998
  • Measurement of electrical resistivity in soils has been used for many years with purpose of estimating in situ porosity or density. Recently electrical resistivity has also been used as an indicator of soil contaimination. This paper presents the result of laboratory experiment to investigate the resistivity variation in contaminated sandy soils. The results can be used with the Cone Penetrometer Test (CPT) result to analyse ground condition. In the experiment, the water content and leachate concentration of soils were controlled by groundwater and leachate, and then the resistivity measurement was made with 'STING-R1' by Advanced Geosciences Inc. In the case of using groundwater, the resistivity was in the range of over 1000${\omega}{\cdot}m$, but in the case of using polluted water by leachate, the resistivity decreased significantly down to 10~ 100${\omega}{\cdot}m$ for the same moisture content. Also the resistivity varied according to the degree of saturatrion. Therefore, if soil is contaminated by leachate, the CPT with electrical resistivity sensor might be used to investigate the contamination status and plume migration. But exact component of leachate and the pollutant concentration are still hard to identify.

  • PDF