• Title/Summary/Keyword: GROUND FIRE

Search Result 343, Processing Time 0.028 seconds

Measurement of Ceiling Temperature in Tunnel for Heights and Fire Sizes of Fire Source (화원의 높이 및 화재크기별 터널 천장온도 측정 실험)

  • Park, Won-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.5-10
    • /
    • 2015
  • The "Ondong tunnel" is not used now where is one of the tunnels in the Janghang line which is from Cheonan to Iksan. The length of the tunnel is 214 m. The location of the fire source is center of the tunnel and the pool fire with heptane is for the fire source. Tests are carried out for the various fire sizes, the height and obstructed/open condition of the fire source. Temperature on the top of the tunnel is measured. Even if the fire size is same, the maximum temperature on the ceiling of the tunnel for the elevated fire source is very larger than the maximum for the ground fire source. As the fire size is lager the maximum temperature on the ceiling is higher. These test results can be very useful for design and guidelines of fire detectors in tunnels.

Cable Functional Failure Temperature Evaluation of Cable Exposed to the Fire of Nuclear Power Plant (원자력발전소 케이블 노출 화재 시 기능상실온도 분석)

  • Lim, Hyuk-Soon;Bae, Yeon-Kyoung;Chi, Moon-Goo
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments. The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, investigation and cause analysis of cable fire in Nuclear Power Plant, we described the cable fire temperature and functional failure criteria and the cable functional failure temperature evaluation by exposed fire is studied.

Comparison of Litter Production and Nutrient returned to Forest Floor according to Forest Fire Type and Recovery (산불유형과 회복정도에 따른 낙엽생산량과 임상으로 이입되는 영양염류 함량)

  • Kim, Jung-Sup;Yang, Keum-Chul
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • This study has compared the different types of forest fire sites and the unburned site at Samcheuk-si Gangwon-do by assessing the amount of litter production, nutrient concentration returned to forest floor from July 2007 through October 2010. The research showed that the average amounts of litterfall produced in the unburned site, the crown fire site(C-1), the crown fire site(C-3) and the ground fire site(G-2) were $7.74{\pm}2.56$, $1.17{\pm}0.67$, $2.97{\pm}0.44$ and $2.92{\pm}0.42ton{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively. In the unburned site, the average amounts of total nitogen(T-N), total phosphorus(T-P), potassium(K), calcium(Ca) and magnesium(Mg) returned to the forest floor were $22.20{\pm}12.43$, $1.16{\pm}0.46$, $2.68{\pm}1.44$, $16.22{\pm}4.69$ and $1.36{\pm}0.32 kg{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively whereas those in the crown fire site(C-1) were $3.73{\pm}2.31$, $0.10{\pm}0.09$, $0.27{\pm}0.20$, $2.75{\pm}2.58$ and $0.24{\pm}0.27 kg{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively. This study showed that the nutrient content returned to forest floor was higher in the following order: unburned site(Un) > crown fire site(C-3) > ground fire site(G-2) > crown fire site(C-1).

Thermal Conductivity Measurement of Grouting Materials for Ground Heat Exchanger Borehole (지중 열교환기 보어홀 그라우팅 재료의 열전도도 측정)

  • Sohn, Byong-Hu;Shin, Hyun-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.493-500
    • /
    • 2006
  • This paper concerns the measurement of thermal conductivity of grouting materials for ground loop heat exchanger. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of neat bentonite and mixtures of bentonite and various additives. Relative to the total mixture mass, as the percent additive was increased the mixture thermal conductivity increased. For the bentonite-silica sand mixtures, the higher density of the sand particles resulted in much higher mixture thermal conductivity. The quartzite and silica sands produced the largest increases in mixture thermal conductivity, while common masonry and limestone sands produced lower thermal conductivity increases.

Some Effects of Fire on Vegetation, Soil and Soil Microflora adjacent to DMZ in Korea (식생, 토양 및 토양미생물에 미치는 불의 효과에 대하여)

  • 홍순우
    • Journal of Plant Biology
    • /
    • v.11 no.4
    • /
    • pp.9-20
    • /
    • 1968
  • In general there are few cases which were caused by lightening and no fire was observed to have been caused but by artificial or accidental fires during preliminary survey. And then the most scales of burning in Korea are like the fig. 2. Temperature 5 cm apart from flame at the burning site were known to range from 165$^{\circ}$to 20$0^{\circ}C$ in surface fire on Myozangdong, pine-quercus dominant community and from 120$^{\circ}$ to 145$^{\circ}C$ in surface fire of Wolwoonni, Mischanthus dominant area and from 120$^{\circ}$ to 14$0^{\circ}C$ in ground fire of Wangzinkun, Mischanthus dominant, respectively. Through the preliminary survey, fire indicater plants in Korea were confirmed as Mischanthus coreensis Hack and Carex alterifolia Franch. The plants of highest frequency appeared in the burnt sites were known to as Potentilla cryptotaeniae Max, Mischanthus coreensis Hack, Carex alterifolia Franch and Artemisia brachyphylla Kitamura. Lespedezas were proved as one of the fire tolerant and Pinus densiflora was found out as the lowest intolerant plant to fire. The acidity of burnt soil was decreased according to the considerable amount of ash left on the ground. The acidity of surface soil was more decreased than the below 10cm of soil. The chemical composition(NO3, P, K, Mg, Total-N and Organic-C) of burnt soil was more increased than those of the unburnt sites. And the population changes of soil microflora seemed to have a certain tendency. The population of soil microflora was increased a little according to climatic conditions. Also there was an initial decrease in the population of microflora followed immediately by a significant increase.

  • PDF

Assessment of Post-Earthquake Fire Behavior of a Steel MRF Building in a Low Seismic Region

  • Chicchi, Rachel;Varma, Amit
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1470-1481
    • /
    • 2018
  • Building-level response to post-earthquake fire hazards in steel buildings has been assessed using primarily two-dimensional analyses of the lateral force resisting system. This approach may not adequately consider potential vulnerabilities in the gravity framing system. For this reason, three-dimensional (3D) finite element models of a 10-story case study building with perimeter moment resisting frames were developed to analyze post-earthquake fire events and better understand building response. Earthquakes are simulated using ground motion time histories, while Eurocode parametric time-temperature curves are used to represent compartment fires. Incremental dynamic analysis and incremental fire analysis procedures capture a range of hazard intensities. Findings show that the structural response due to earthquake and fire hazards are somewhat decoupled from one another. Regardless of the level of plastic hinging present in the moment framing system due to a seismic event, gravity column failure is the initiating failure mode in a fire event.

Enhancing fire resistance of steel bridges through composite action

  • Kodur, Venkatesh K.R.;Gil, Augusto
    • Steel and Composite Structures
    • /
    • v.43 no.3
    • /
    • pp.353-362
    • /
    • 2022
  • Bridge fire hazard has become a growing concern over the last decade due to the rapid increase of ground transportation of hazardous materials and resulting fire incidents. The lack of fire safety provisions in steel bridges can be a significant issue owing steel thermal properties that lead to fast degradation of steel properties at elevated temperatures. Alternatively, the development of composite action between steel girders and concrete decks can increase the fire resistance of steel bridges and meet fire safety requirements in some applications. This paper reviews the fire problem in steel bridges and the fire behavior of composite steel-concrete bridge girders. A numerical model is developed to trace the fire response of a typical bridge girder and is validated using measurements from fire tests. The selected bridge girder is composed by a hot rolled steel section strengthened with bearing stiffeners at midspan and supports. A concrete slab sitting on the top of the girder is connected to the slab through shear studs to provide full composite action. The validated numerical model was used to investigate the fire resistance of real scale bridge girders and the effect of the composite action under different scenarios (standard and hydrocarbon fires). Results showed that composite action can significantly increase the fire resistance of steel bridge girders. Besides, fire severity played an important role in the fire behavior of composite girders and both factors should be taken into consideration in the design of steel bridges for fire safety.

Refinement of Ground Truth Data for X-ray Coronary Artery Angiography (CAG) using Active Contour Model

  • Dongjin Han;Youngjoon Park
    • International journal of advanced smart convergence
    • /
    • v.12 no.4
    • /
    • pp.134-141
    • /
    • 2023
  • We present a novel method aimed at refining ground truth data through regularization and modification, particularly applicable when working with the original ground truth set. Enhancing the performance of deep neural networks is achieved by applying regularization techniques to the existing ground truth data. In many machine learning tasks requiring pixel-level segmentation sets, accurately delineating objects is vital. However, it proves challenging for thin and elongated objects such as blood vessels in X-ray coronary angiography, often resulting in inconsistent generation of ground truth data. This method involves an analysis of the quality of training set pairs - comprising images and ground truth data - to automatically regulate and modify the boundaries of ground truth segmentation. Employing the active contour model and a recursive ground truth generation approach results in stable and precisely defined boundary contours. Following the regularization and adjustment of the ground truth set, there is a substantial improvement in the performance of deep neural networks.