• 제목/요약/키워드: GOM Inspect software

검색결과 4건 처리시간 0.018초

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts

  • Anne Kaline Claudino Ribeiro;Aretha Heitor Verissimo;Rodrigo Falcao Carvalho Porto de Freitas;Rayanna Thayse Florencio Costa;Burak Yilmaz;Sandra Lucia Dantas de Moraes;Adriana da Fonte Porto Carreiro
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.139-150
    • /
    • 2024
  • PURPOSE. The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND METHODS. A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time. RESULTS. The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001). CONCLUSION. The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study

  • Dina Mohamed Ahmed Elawady;Wafaa Ibrahim Ibrahim;Radwa Gamal Ghanem;Reham Bassuni Osman
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권4호
    • /
    • pp.201-211
    • /
    • 2024
  • PURPOSE. The aim of this prospective clinical study was to compare the influence of palatal vault forms on accuracy and speed of intraoral (IO) scans in completely edentulous cases. MATERIALS AND METHODS. Based on the palatal vault form, participants were divided into three equal groups (n = 10 each); Class I: moderate; Class II: deep; Class III: flat palatal vault. A reference model was created for each patient using polyvinylsiloxane impression material. The poured models were digitized using an extraoral scanner. The resultant data were imported as a solid CAD file into 3D analysis software (GOM Inspect 2018; Gom GmbH, Braunschweig, Germany) and aligned using the software's coordinate system to determine its X, Y, and Z axes. Five digital impressions (DIs) of maxilla were captured for each patient using an intraoral scanner (TRIOS; 3Shape A/S, Copenhagen, Denmark) and the resultant Standard Tessellation Language (STL) scan files served as test models. Trueness was evaluated by calculating arithmetic mean deviation (AMD) of the vault area between reference and test files while precision was evaluated by calculating AMD between captured scans to measure repeatability of scan acquisition. The scan time taken for each participant was also recorded. RESULTS. There was no significant difference in trueness and precision among the groups (P = .806 and .950, respectively). Average scan time for Class I and III palatal vaults was 1 min 13 seconds and 1 min 37 seconds, respectively, while class II deep palatal vaults showed the highest scan time of 5 mins. CONCLUSION. Palatal vault form in edentulous cases has an influence on scan time. However, it does not have a substantial impact on the accuracy of the acquired scans.

2급 악간관계를 보이는 하악 무치악 환자에서 디지털 진단기술을 이용한 임플란트 피개의치 수복증례 (Utilization of digital technology in fabricating mandibular implant overdenture for skeletal class II edentulous patient: A case report)

  • 이연이;홍성진;백장현;노관태;권긍록
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.364-373
    • /
    • 2019
  • 2급 악간관계를 갖는 환자는 1급 악간관계인 환자와는 달리 불안정한 교합을 가질 수 있으며, 무치악인 경우 총의치를 사용할 때 불안정한 교합을 보이면서 의치의 움직임이 커질 가능성이 있다. 이런 환자에 있어 임플란트 피개의치를 사용함으로써 의치의 안정을 향상시킬 수 있다. 임플란트 피개의 치에서 attachment 종류는 크게 bar type과 solitary type으로 나눌 수 있는데 각각 적응증이 있어 상황에 따라 적용을 달리 하여야 한다. 본 증례는 2급 악간관계를 가진 하악 무치악 환자에서 임플란트 피개의치를 계획함에 있어 디지털 기술을 이용함으로써 더 적합한 attachment를 선택하고 임플란트의 위치 및 깊이를 미리 계획하여 계획한 위치에 식립하였다. 상악은 국소의치로 수복하였고 하악은 임플란트 피개의치로 수복하여 만족할만한 결과를 얻었기에 이를 보고하고자 한다.

Influence of Band and Loop Type Space Maintainer on Intraoral Scanning Accuracy of an Adjacent Tooth

  • Ju Ri Ye;Yong Kwon Chae;Ko Eun Lee;Hyo-Seol Lee;Sung Chul Choi;Ok Hyung Nam
    • Journal of Korean Dental Science
    • /
    • 제16권2호
    • /
    • pp.149-155
    • /
    • 2023
  • Purpose: The purpose of this study was to evaluate whether the presence of a space maintainer affects the accuracy of an intraoral scanner. Materials and Methods: The maxillary primary first molar typodont tooth was removed from the primary dentition typodont model and a band and loop type space maintainer was delivered. After the model was connected to a dental phantom, intraoral scan was performed using TRIOS 4 (3Shape A/S, Copenhagen, Denmark). The scan was repeated with the same technique without the space maintainer. Each scan was performed 10 times. All scan files into a GOM inspect 2018 software and evaluated the accuracy. The accuracy was evaluated on trueness and precision, and calculated using the root mean square value. Result: When there was a space maintainer in the oral cavity, the trueness value was 0.10±0.02 mm and the precision value was 0.15±0.03 mm. In the absence of the space maintainer, the trueness value was 0.12±0.03 mm and the precision value was 0.16±0.04 mm. There were no significant differences depending on the presence of a space maintainer (P>0.05). Conclusion: Within the limits of this study, the accuracy of the intraoral scanner was not influenced by the presence of space maintainer.