• Title/Summary/Keyword: GOLD

Search Result 3,622, Processing Time 0.035 seconds

Olympic Advertisers Win Gold, Experience Stock Price Gains During and After the Games (오운선수작위엄고대언인영득금패(奥运选手作为广告代言人赢得金牌), 비새중화비새후적고표개격상양(比赛中和比赛后的股票价格上扬))

  • Tomovick, Chuck;Yelkur, Rama
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.1
    • /
    • pp.80-88
    • /
    • 2010
  • There has been considerable research examining the relationship between stockholders equity and various marketing strategies. These include studies linking stock price performance to advertising, customer service metrics, new product introductions, research and development, celebrity endorsers, brand perception, brand extensions, brand evaluation, company name changes, and sports sponsorships. Another facet of marketing investments which has received heightened scrutiny for its purported influence on stockholder equity is television advertisement embedded within specific sporting events such as the Super Bowl. Research indicates that firms which advertise in Super Bowls experience stock price gains. Given this reported relationship between advertising investment and increased shareholder value, for both general and special events, it is surprising that relatively little research attention has been paid to investigating the relationship between advertising in the Olympic Games and its subsequent impact on stockholder equity. While attention has been directed at examining the effectiveness of sponsoring the Olympic Games, much less focus has been placed on the financial soundness of advertising during the telecasts of these Games. Notable exceptions to this include Peters (2008), Pfanner (2008), Saini (2008), and Keller Fay Group (2009). This paper presents a study of Olympic advertisers who ran TV ads on NBC in the American telecasts of the 2000, 2004, and 2008 Summer Olympic Games. Five hypothesis were tested: H1: The stock prices of firms which advertised on American telecasts of the 2008, 2004 and 2000 Olympics (referred to as O-Stocks), will outperform the S&P 500 during this same period of time (i.e., the Monday before the Games through to the Friday after the Games). H2: O-Stocks will outperform the S&P 500 during the medium term, that is, for the period of the Monday before the Games through to the end of each Olympic calendar year (December 31st of 2000, 2004, and 2008 respectively). H3: O-Stocks will outperform the S&P 500 in the longer term, that is, for the period of the Monday before the Games through to the midpoint of the following years (June 30th of 2001, 2005, and 2009 respectively). H4: There will be no difference in the performance of these O-Stocks vs. the S&P 500 in the Non-Olympic time control periods (i.e. three months earlier for each of the Olympic years). H5: The annual revenue of firms which advertised on American telecasts of the 2008, 2004 and 2000 Olympics will be higher for those years than the revenue for those same firms in the years preceding those three Olympics respectively. In this study, we recorded stock prices of those companies that advertised during the Olympics for the last three Summer Olympic Games (i.e. Beijing in 2008, Athens in 2004, and Sydney in 2000). We identified these advertisers using Google searches as well as with the help of the television network (i.e., NBC) that hosted the Games. NBC held the American broadcast rights to all three Olympic Games studied. We used Internet sources to verify the parent companies of the brands that were advertised each year. Stock prices of these parent companies were found using Yahoo! Finance. Only companies that were publicly held and traded were used in the study. We identified changes in Olympic advertisers' stock prices over the four-week period that included the Monday before through the Friday after the Games. In total, there were 117 advertisers of the Games on telecasts which were broadcast in the U.S. for 2008, 2004, and 2000 Olympics. Figure 1 provides a breakdown of those advertisers, by industry sector. Results indicate the stock of the firms that advertised (O-Stocks) out-performed the S&P 500 during the period of interest and under-performed the S&P 500 during the earlier control periods. These same O-Stocks also outperformed the S&P 500 from the start of these Games through to the end of each Olympic year, and for six months beyond that. Price pressure linkage, signaling theory, high involvement viewers, and corporate activation strategies are believed to contribute to these positive results. Implications for advertisers and researchers are discussed, as are study limitations and future research directions.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Plasma D-dimer Determination in the Diagnosis of Pulmonary Embolism (폐색전증의 진단에 있어 혈청 D-dimer 측정의 진단적 가치)

  • Lim, Chae-Man;Kim, Hong-Kyu;Choi, Kang-Hyun;Lee, Sand-Do;Koh, Youn-Suck;Kim, Woo-Sung;Jang, Jae-Suck;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.69-74
    • /
    • 1996
  • Background: The diagnosis of pulmonary embolism (PE) based on clinical findings is often elusive and therefore requires confirmative diagnostic method. Pulmonary angiography, though the gold standard for the diagnosis of pulmonary embolism, is an invasive method and requires trained personnel and special equipment. Lung V/Q scan, on the other hand, is a noninvasive method but the diagnostic specificity and sensitivity arc not satisfactory in case that the results are either intermediate or low probability scan. Plasma D-dimer is generated when a thrombus is fibrinolysed by plasmin and is known to be increased in various thrombotic disorders. The aim of this study was to investigate the value of the determination of plasma D-dimer level in the diagnosis of pulmonary embolism. Methods: Pulmonary angiography was performed in 17 patients who were clinically suspected to have pulmonary embolism. 9 patients(PE, $56{\pm}13.4$ yrs, M:F=8:1) were diagnosed to have pulmonary embolism by pulmonary angiography. The control group were the 8 patients with negative pulmonary angiography and 13 orthopedic patients with no evidence of pulmonary embolism on scintigraphic and impedance plethysmographic studies(n=21) (non-PE, $54.5{\pm}11.1$ yrs, M:F=11:10). Plasma D-dimer was measured by latex agglutination method in study subjects and the results were analyzed according to the presence or absence of pulmonary embolism. Results: 1) The increased level of plasma D-dimer was more frequently observed in the patients with pulmonary embolism than in the controls(>0.5 mg/L, 8 in PE, 10 in non-PE; <0.5 mg/L, 1 in PE, 11 in non-PE, p=0.049). 2) The diagnostic value of plasma D-dimer level higher than 0.5 mg/L were as follows: sensitivity 88.9%(8/9), specificity 52.4%(11/21), positive predictive value 44.4%(8/18), and negative predictive value 91.7%(11/12). Conclusion: Plasma D-dimer determination showed high sensitivity and negative predictive value in the diagnosis of pulmonary embolism and is therefore thought to be useful in excluding the possibility of pulmonary embolism.

  • PDF

The Great Depression in High School Social Science Textbooks : Critiques and Suggestions (대공황에 대한 고등학교 사회과 교과서 서술의 문제점과 개선방안)

  • Kim, Duol
    • KDI Journal of Economic Policy
    • /
    • v.30 no.1
    • /
    • pp.171-209
    • /
    • 2008
  • The Great Depression is one of the most important economic incidents in the twentieth century. A significant and long-lasting impact of this event is the rise of the government intervention to the economy. Under the catastrophic downturn of the economic condition worldwide, people required their government to play an active role for economic recovery, and this $mentalit{\acute{e}}$ prolonged even after the Second World War. Social science textbooks taught at Korean high schools mostly referred to the Great Depression for explaining the reason of government intervention in economy. However, the mainstream view commonly found in the textbooks provides a misleading theological interpretation. It argues that inherent flaws of the market economy causes over-production/under-consumption, and that this mismatch ends up with economic crisis. The chaotic situation was resolved by substitution of the governments for the market, and the New Deal was introduced as the monumental example ('laissez-faire economy ${\rightarrow}$over-production${\rightarrow}$the Great Depression${\rightarrow}$government intervention${\rightarrow}$economic recovery'). Based on economic historians' researches for past three decades, I argue that this mainstream view commits the fallacy of ex-post justification. Unlike what the mainstream view claims, the Great Depression was neither the result of the 'market failure', nor the recovery from the Great Depression but was due to successful government policies. For substantiating this claim, I suggest three points. First, blaming the weakness or instability of the market economy as the cause of the Great Depression is groundless. Unlike what the textbooks describe, the rise of the U.S. stock price during the 1920s cannot be said as a bubble, and there was no sign of under-consumption during the 1920s. On the contrary, a new consensus emerging from the 1980s among economic historians illustrates that the Great Depression was originated from 'the government failure' rather than from the 'market failure'. Policymakers of European countries tried to return to the gold standard regime before the First World War, but discrepancies between this policy and the reality made the world economy vulnerable. Second, the mainstream view identifies the New Deal as Keynesian interventionism and glorifies it for saving the U.S. economy from the crisis. However, this argument is not true. The New Deal was not Keynesian at all. What the U.S. government actually tried was not macroeconomic stabilization but price and quantity control. In addition, New Deal did not brought about economic recovery that people generally believe. Even after the New Deal, industrial production or employment level remained quite low until the late 1930s. Lastly, studies on individual New Deal policies show that they did not work as they were intended. For example, the National Industrial Recovery Act increased unemployment, and the Agricultural Adjustment Act expelled tenants from their land. Third, the mainstream view characterizes the economic order before the Great Depression as laissez-faire, and it tends to attribute all the vice during the Industrial Revolution era to the uncontrolled market economy. However, historical studies show that various economic and social problems of the Industrial Revolution period such as inequality problems, child labor, or environmental problems cannot be simply ascribed to the problems of the market economy. In conclusion, the remedy for all these problems in high school textbooks is not to use the Great Depression as an example showing the weakness of the market economy. The Great Depression should be introduced simply as a historical momentum that had initiated the growth of government intervention. This reform of high school textbooks is imperative for enhancing the right understanding of economy and history.

THE COMPARISON OF CITRIC ACID AND TETRACYCLINE HCL ON TREATED ROOT SURFACES ON THE PROLIFERATION AND SPREADING OF PERIODONTAL LIGAMENT CELLS (치근면 탈회제인 테트라시이클린과 구연산이 치주인대세포 증식과 전개에 미치는 영향에 대한 비교)

  • Park, Jae-Wan;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.587-602
    • /
    • 1995
  • The purpose of this study was to compare the effects of citric acid and tetracycline HCI application to the root surfaces of periodontally diseased teeth on the proliferation and spreading of human periodontal ligament cells. The roots were prepared so that the comparison could be made among root planed, citric acid treated and tetracycline HCI treated surfaces. In the cell proliferation experiment, human periodontal ligament cells at a concentration of $1{\times}10^5$ cells/ml were seeded in each culture well with specimens and incubated for 6 hours. Then, the specimens were transferred to a fresh culture well and incubated for 24, 48, 72 hours respectively. The cell counting was done after trypsinization. In the cell spreading experiment, $1{\times}10^4$ cells/ml were seeded in each culture well and incubated for 30min, 6 hours and 24 hours at 37.5$^{\circ}C$ in a $CO_2$ incubator. Then, all specimens were fixed with phosphate buffered glutaraldehydes, postfixed with phosphate buffered osmium tetraoxide, stained with phosphate buffered tannic acid, dehydrated in ethanol, dried at a critical point, coated with gold and examined under a scanning electron microscope. The results were as follows:In the cell proliferation experiments, the number of attached cells increased more in the tetracycline treated group than in the other groups. In the initial attachment, the appearance of the tetracycline treated the groups was slightly more spread out than in the other groups. After 6 hours of incubation, it was observed in most of the cells that cell morphologic alteration went from ovoid shapes sto spindle shapes. After 24 hours of incubation, the cells of all groups had a fusiform appearance and were connected to each other by numerous cytoplasmic processes. The tetracycline and citric acid treated groups had a similar spreading appearance of periodontal ligament cells, but the tetracycline treated group was more effective in the cell proliferation than the citric acid group.

  • PDF

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

COMPARATIVE STUDY OF PHYSICAL PROPERTIES FOR VARIOUS BAND CEMENTS (수종의 밴드 접착 시멘트의 물성에 대한 비교 연구)

  • Yang, Kyu-Ho;Kim, Ki-Baek;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.427-432
    • /
    • 2009
  • The aim of this study was to compare the shear-peel strength and the fracture site of 5 commercially available orthodontic band cements. One hundred molar bands were cemented to extracted human 3rd molars. The specimens were prepared in accordance with the manufacturer's instructions for each cement. After storage in a humidor at $37^{\circ}C$ for 24 hours, the shear debonding force was assessed for each specimen using an universal testing machine with crosshead speed of 2 mm/minute. Maximal failure stress was converted to mean shear-peel strength, MPa. The predominant site of band failure was recorded visually for all specimens as either at the band/cement or cement/enamel interface. Mean shear-peel strength of Ormco was the highest(2.44${\pm}$0.57), followed by Fuji $Ortho^{TM}$(2.24${\pm}$0.50), $Ketac-Cem^{TM}$(2.10${\pm}$0.57), 3M $Unitek^{TM}$(1.82${\pm}$0.43), $Band-Lok^{TM}$(1.73${\pm}$0.28). There were statistically significant differences between Ormco and $Band-Lok^{TM}$, Ormco and 3M $Unitek^{TM}$, and Fuji $Ortho^{TM}$ and $Band-Lok^{TM}$(p<0.05). The predominant site of bonding failure for bands cemented with the Ormco was at the band/cement interface, whereas bands cemented with Ultra $Band-Lok^{TM}$ failed predominantly at the enamel/cement interface. There was no significant difference among the other cements(Fuji $Ortho^{TM}$, 3M $Unitek^{TM}$, $Ketac-Cem^{TM}$).

  • PDF

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF

Accuracy of Spirometry at Predicting Restrictive Pulmonary Impairment (제한성 환기장애의 진단에서 폐활량검사의 정확성)

  • Ahn, Young Mee;Koh, Won-Jung;Kim, Cheol Hong;Lim, Seong Yong;An, Chang Hyeok;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.330-337
    • /
    • 2003
  • Background : Low spirometric forced vital capacity(FVC) in conjunction with a normal or high ratio of the forced expiratory volume at 1 second to the forced vital capacity($FEV_1$/FVC%) has traditionally been classified as a restrictive abnormality. However, the gold-standard diagnosis of a restrictive pulmonary impairment requires a measurement of the total lung capacity (TLC). This study was performed to determine the predictive value of spirometric measurements of the FVC for diagnosing a restrictive pulmonary abnormality. Methods : Test results from 1,371 adult patients who undertook both spirometry and lung volume measurements on the same visit from January 1999 to December 2000 were enrolled in this study. The test values for the FVC, the TLC that was below 80% of predicted value, and a $FEV_1$/FVC% that was below 70%, were classified as being abnormal. Results : Of the 1,371 patients, 353 patients had a reduced a FVC. Of these patients, 186 patients had a reduced TLC. Therefore, the positive predictive value was 52.7%. Of the 196 patients with a normal $FEV_1$/FVC% and a reduced FVC, 148(75.5%) patients had a lower TLC. Thirty eight (24.2%) patients out of 157 patients with a low $FEV_1$/FVC% and a low FVC showed a restrictive defect. Conclusion : Spirometry is useful to rule out a restrictive pulmonary abnormality, but a restrictive pattern on the spirometry dose not mean there is a true restrictive disease. For the patients with a low FVC, TLC measurements are essential for diagnosing a restrictive pulmonary impairment.