• Title/Summary/Keyword: GMI

Search Result 50, Processing Time 0.039 seconds

TISSUE CHANGE AFTER EMBEDDING GELATIN MATRIX IMPLANT(FFIBREL®) IN SUBCUTANEOUS TISSUE OF RATS;HISTOLOGIC, IMMUNOHISTOCHEMICAL AND SCANNING ELECTRON MICROSCOPIC STUDY (백서의 피하조직에 Gelatin Matrix Implant (Fibrel®) 매식시 조직변화에 관한 연구)

  • Kim, Hong-Jin;Lee, Chong-Heon;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.341-354
    • /
    • 1998
  • GMI (Fibrel${(R)}$) is one of the dermal filling substances which have been successfully used for the treatment of depressed cutaneous scar and wrinkles. It's major components are; Gelatin powder, which provides a framework for the clot to form and remains stable under the scar, and ${\varepsilon}$-aminocaproic acid, which inhibits the production of fibrinolysin, and Plasma, which provides the necessary ingredients for collagen synthesis. GMI has advantages of low immunogenicity and increased longevity. It has been known to induce fibroblast activity and promote new collagen synthesis. We used 34 Sprague-Dawley rats which were bred under the same condition and duration. 18 of experimental animals were undergone cardiac puncture, and their blood were collected, centrifugated, and stored in freezer. Out of 16 animals, control group were injected with 2ml plasma into the subcutaneous tissue of Lt. scapular, while experimental group were implanted of 2 ml GMI into the Rt. same area. Experimental animals were sacrificed at the 3rd day, 5th day, 1st week and 2nd week respectively after implantation of GMI. To observe the histopathologic change of GMI and surrounding tissue reaction of GMI, we had examined with H&E staining, immunohistochemical staining with vimentin, ${\alpha}$-SMA, S-100 under LM and SEM. The obtained results were as follows ; 1. In LM study, the inflammatory cell infiltrations and granulation tissue formation were observed, and muscle tissues were well attached with adipose tissues in the control group. In the experimental group, inflammatory cell infiltrations had been observed by the 2nd week and irregular adipiose tissues and well differentiated mesenchymal tissues were examined. 2. In immunohistochemical study, the experimental group of ${\alpha}$-SMA study, there were a prominent positive response on endothelial development of granulation tissues and mesenchymal tissues compare with the control group. In vimentin study, positive response on mescenchymal fibroblast continued to 2nd week, but negative in the control group. In S-100 study, both groups were positively responded on irregular adipose tissues. 3. In SEM study, collagen fibers were embedded by the plasma by the 5th day in the control group, and in the 3rd day experiment GMI were resorved but communited with collagen fiber till the 1st week. Collagen fibers were infilt-rated into GMI at the 2nd week and the infilltrated GMI were conglomerated with the mature adipose cells and the collagen fibers. From the above results, GMI implantation in the subcutaneous tissue of Sprague-Dawley rat, the mild infiltration of inflammatory cells were showed till 2nd week and the granulation tissues were observed. GMI were nearly resorbed till 2nd week, but well attached with adipose tissue and collagen fibers. The endothelium and fibroblasts were actively proliferated. Adipose tissues and mesenchymal tissue cells were observed. As already expressed, GMI showed resorptive change in course of time without any early immune reaction, and seemed to induce fibroblast activity and promote new collagen synthesis.

  • PDF

GMI Magnetic Field Sensor Based on a Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.221-224
    • /
    • 2010
  • A laboratory sensor model was designed, constructed, and tested based on a newly proposed working principle of magnetic field detection. The principle of sensing employed a time-coded method in correlation with exploiting the advantageous features of the GMI effect. The sensor demonstrated a sensitivity of $10\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. The sensing element in the form of an amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ long, was fit into a small field modulation coil of 60 mm length. At a magnetic field modulation in the range of hundreds of Hz, the change in time interval of two adjacent GMI voltage peaks was linearly related to the external magnetic field to be measured. This mechanism improved the sensor linearity of the GMI sensor to better than 0.2% in the measuring range of ${\pm}100\;{\mu}T$.

Dependence of GMI Profile on Size of Co-based Amorphous Ribbon

  • Jin, L.;Yoon, S.S.;Kollu, P.;Kim, C.G.;Suhr, D.S.;Kim, C.O.
    • Journal of Magnetics
    • /
    • v.12 no.1
    • /
    • pp.31-34
    • /
    • 2007
  • The Co-based ribbons with different length were annealed in different magnetic field and GMI profiles were investigated in order to clarify the influence of ribbon size on GMI effect. The GMI ratio decreased with the decreasing in length and also decreased with increasing annealing field. While, the slope of GMI profiles inclined and the field range showing linearity was broadened. It shows prospect to low field sensor, especially for a navigation sensor.

Effectiveness of graded motor imagery in subjects with frozen shoulder: a pilot randomized controlled trial

  • Gurudut, Peeyoosha;Godse, Apurva Nitin
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.152-159
    • /
    • 2022
  • Background: Subjects with frozen shoulder (FS) might not be comfortable with vigorous physical therapy. Clinical trials assessing the effect of graded motor imagery (GMI) in FS are lacking. The aim of this study was to determine the effect of GMI as an adjunct to conventional physiotherapy in individuals with painful FS. Methods: Twenty subjects aged 40-65 years having stage I and II of FS were randomly divided into two study groups. The conventional physiotherapy group (n = 10) received electrotherapy and exercises while the GMI group (n = 10) received GMI along with the conventional physiotherapy thrice a week for 3 weeks. Pre- (Session 1) and post- (Session 9) intervention analysis for flexion, abduction, and external rotation range of motion (ROM) using a universal goniometer, fear of movement using the fear avoidance belief questionnaire (FABQ), pain with the visual analogue scale, and functional disability using the shoulder pain and disability index (SPADI) was done by a blinded assessor. Results: Statistically significant difference was seen within both the groups for all the outcomes. In terms of increasing abduction ROM as well as reducing fear of movement, pain, and functional disability, the GMI group was significantly better than control group. However, both groups were equally effective for improving flexion and external rotation ROM. Conclusions: Addition of GMI to the conventional physiotherapy proved to be superior to conventional physiotherapy alone in terms of reducing pain, kinesiophobia, and improving shoulder function for stage I and II of FS.

GMI Microwave Sea Surface Temperature Validation and Environmental Factors in the Seas around Korean Peninsula (한반도 주변해 GMI 마이크로파 해수면온도 검증과 환경적 요인)

  • Kim, Hee-Young;Park, Kyung-Ae;Kwak, Byeong-Dae;Joo, Hui-Tae;Lee, Joon-Soo
    • Journal of the Korean earth science society
    • /
    • v.43 no.5
    • /
    • pp.604-617
    • /
    • 2022
  • Sea surface temperature (SST) is a key variable that can be used to understand ocean-atmosphere phenomena and predict climate change. Satellite microwave remote sensing enables the measurement of SST despite the presence of clouds and precipitation in the sensor path. Therefore, considering the high utilization of microwave SST, it is necessary to continuously verify its accuracy and analyze its error characteristics. In this study, the validation of the microwave global precision measurement (GPM)/GPM microwave imager (GMI) SST around the Northwest Pacific and Korean Peninsula was conducted using surface drifter temperature data for approximately eight years from March 2014 to December 2021. The GMI SST showed a bias of 0.09K and an average root mean square error of 0.97K compared to the actual SST, which was slightly higher than that observed in previous studies. In addition, the error characteristics of the GMI SST were related to environmental factors, such as latitude, distance from the coast, sea wind, and water vapor volume. Errors tended to increase in areas close to coastal areas within 300 km of land and in high-latitude areas. In addition, relatively high errors were found in the range of weak wind speeds (<6 m s-1) during the day and strong wind speeds (>10 m s-1) at night. Atmospheric water vapor contributed to high SST differences in very low ranges of <30 mm and in very high ranges of >60 mm. These errors are consistent with those observed in previous studies, in which GMI data were less accurate at low SST and were estimated to be due to differences in land and ocean radiation, wind-induced changes in sea surface roughness, and absorption of water vapor into the microwave atmosphere. These results suggest that the characteristics of the GMI SST differences should be clarified for more extensive use of microwave satellite SST calculations in the seas around the Korean Peninsula, including a part of the Northwest Pacific.

GMI Magnetic Field Sensor based on Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2009.12a
    • /
    • pp.217-219
    • /
    • 2009
  • A GMI magnetic field sensor working based on time-coded principle has been investigated and designed. The laboratory model has been constructed and tested carefully, demonstrating the sensitivity of $3\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. An amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ in length, was chosen to be sensing element which was fit into a small field modulation coil of 60 mm in length. The sensor is working based on a time-coded principle that, with the magnetic field modulation was chosen in range of hundreds of Hz, the change in time interval of two adjacent GMI peaks relating to external DC magnetic field is proportional to the intensity of the external field to be measured. This mechanism has made a great improvement to the linearity of the sensor.

  • PDF

Current sensor application of giant magnetoimpedance in amorphous materials (교류자기저항효과를 이용한 비정질 리본 전류센서)

  • Rheem, Y.W.;Kim, C.G.;Kim, C.O.;Kim, G.D.;Park, Y.T.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.11-13
    • /
    • 2002
  • The performance of DC current sensor based on giant magnetoimpedance (GMI) effect in amorphous ribbon has been tested. The ribbon after field annealing shows the maximum GMI ratio of 30 % at 100 kHz measuring frequency. In the sensor element of sample wound the circular form, GMI ratio and sensitivity are decreased due to internal stress. The sensor voltage output increases with applied DC current up to 1 A with a good linearity, of which direction can be known due to asymmetric characteristics.

  • PDF

Time-Coded GMI Magnetic Field Sensor

  • Cao, Xuan-Huu;Son, Derac
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.129-131
    • /
    • 2009
  • A time-coded giant magnetoimpedance (GMI) magnetic field sensor was investigated and designed. The successfully constructed and tested laboratory model demonstrated a sensitivity of 5 ${\mu}s/{\mu}T$ in the field range of $\pm200{\mu}T$. The sensing element in the form of an amorphous thin wire, 100 mm in diameter $\times50$ mm long, was fit into a small field modulation coil of 60 mm length. At a magnetic field modulation in the range of hundreds of Hz, the change in time interval of two adjacent GMI voltage peaks was linearly related to the external magnetic field to be measured. This mechanism improved the sensor linearity to better than 0.3% in the measuring range of $\pm200{\mu}T$.

Surface Crystalline Modification for Asymmetric Giant Mngnetoimpedance Profile in Annealed Co-based Amorphous Ribbons

  • Rheem, Y.W;Kim, C.G;Kim, C.O;Choi, Y
    • Journal of Magnetics
    • /
    • v.6 no.3
    • /
    • pp.86-89
    • /
    • 2001
  • Microstructure modifications are investigated for annealed Co-based amorphous ribbon in vacuum and open air. X-ray diffraction (XRD) spectra for annealed sample in vacuum indicate atomic arrangements with initial nucleation of hcp-Co crystallite at 38$0^{\circ}C$ annealing temperature. However, the XRD spectra in samples with long annealing times of $t_a\geq300$ min demonstrate sharp and good developed surface crystalline hcp-, fcc- Co and $Co_2$Si phases. The giant magnetoimpedance (GMI) profile at 0.1 MHz displaying one-peak behavior in vacuum annealed samples at T = 38$0^{\circ}C$ irrespective of annealing time $t_a$ from 20 to 480 mim. For the annealed samples in an open air, the GMI profile shows two-peaks for $t_a$ = 20 min annealed sample. However, one of peaks disappears and an asymmetric GMI profile exhibits a drastic step-like change near zero field for $t_a\geq300$min. Such asymmetric GMI characteristics is related to the surface microstructures of fcc-Co, hop-Co and $Co_2$Si crystalline phases.

  • PDF