• Title/Summary/Keyword: GMB

Search Result 408, Processing Time 0.026 seconds

The Optimization of the Number and Positions of Foot Pressure Sensors to Develop Smart Shoes

  • Yoo, Sihyun;Gil, Hojong;Kim, Jongbin;Ryu, Jiseon;Yoon, Sukhoon;Park, Sang Kyoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.395-409
    • /
    • 2017
  • Objective: The purpose of this study was to optimize the number and positions of foot pressure sensors using the reliability analysis of the center of pressure (COP) in smart shoes. Background: Foot pressure can be different according to foot region, and it is important which region of the foot pressure needs to be measured. Method: Thirty adults (age: $20.5{\pm}1.8years$, body weight: $71.4{\pm}6.5kg$, height: $1.76{\pm}0.04m$) participated in this study. The foot pressure data were collected using the insole of Pedar-X system (Novel GmbH, USA) with a sampling frequency of 100Hz during 1.3m/s speed walking on the treadmill (Instrumented treadmill, Bertec, USA). The intraclass correlation coefficients (ICC) were calculated between the COP positions using 4, 5, 6, 7, 8, and 99 sensors, while one-way repeated measure ANOVA was performed between the standard deviation (SD) of the COP positions. Results: The medio-lateral (M/L) COP position using 99 sensors was positively correlated with the M/L COP positions using 6, 7, and 8 sensors; however, it was not correlated with the M/L COP positions using 4 and 5 sensors during landing phase (1~4%) (p<.05). The antero-posterior (A/P) COP position using 99 sensors was positively correlated with the A/P COP positions using 4, 5, 6, 7, and 8 sensors (p<.05). The SD of the COP position using 99 sensors was smaller than the SD of the M/L COP positions using 4, 5, 6, 7, and 8 sensors (p<.05). Conclusion: Based on our findings, it is desirable to arrange at least 6 sensors in smart shoes. Application: The study of optimizing the number and positions of foot pressure sensors would contribute to developing more effective smart shoes using foot pressure technology.

Estimation of Genetic Variation in Holstein Young Bulls of Iran AI Station Using Molecular Markers

  • Rahimi, G.;Nejati-Javaremi, A.;Saneei, D.;Olek, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.4
    • /
    • pp.463-467
    • /
    • 2006
  • Genetic profiles of Iranian Holstein young bulls at the national artificial insemination station were determined on the basis of individual genotypes at 13 ISAG's recommended microsatellites, the most useful markers of choice for parentage identification. In the present study a total of 119 individuals were genotyped at 13 microsatellite loci and for possible parent-offspring combinations. A high level of genetic variation was evident within the investigated individuals as assessed from various genetic diversity measures. The mean number of observed alleles per microsatellite marker was 9.15 and the number of effective alleles as usual was less than the observed values (4.03). The average observed and expected heterozygosity values were 0.612 and 0.898, respectively. The mean polymorphic information content (PIC) value (0.694) further reflected a high level of genetic variability. The average exclusion of probability (PE) of the 13 markers was 0.520, ranging from 0.389 to 0.788. The combined exclusion of probability was 0.999, when 13 microsatellite loci were used for analysis in the individual identification system. Inbreeding was calculated as the difference between observed and expected heterozygosity. Observed homozygosity was less than expected which reflects inbreeding of -3.7% indicating that there are genetic differences between bull-sires and bull-dams used to produce young bulls. The results obtained from this study demonstrate that the microsatellite DNA markers used in the present DNA typing are useful and sufficient for individual identification and parentage verification without accurate pedigree information.

Factor Analysis and Intergroup Awareness Investigation of Workers' Safety in Logistic Center (물류센터 근로자의 안전인식에 대한 요인분석 및 집단간 인식 비교)

  • Choi, Hyunjoon;Moon, Sangyoung;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.113-119
    • /
    • 2015
  • This study is to examine the workers' awareness of the safety in logistic centers. For that purpose, the exploratory factor analysis of workers' safety awareness in logistic centers was performed at first, and the 6 variables extracted from the factor analysis were then used to investigate the difference in intergroup awareness of the safety environment in the logistic centers. We administered a survey to 147 workers attending the logistic centers and collected data from them. The results of the study showed that the intergroup awareness of the safety environment turned out to be statistically different from each other in terms of working environment, safe behavior, work risk, safety knowledge and effort, risk justification and compromising attitudes. Experiences in industrial accidents influenced awareness of working environment, work risk and risk justification. The group who experienced accidents is more likely to feel risky and unsatisfied with working place, and their awareness toward risk justification was high as well. It was also observed that there exists awareness difference between manager group and worker group. The group who manages the working place showed more positive awareness of working environment, safe behavior, work risk, safety knowledge and effort, risk justification and compromising attitudes than the worker group. On the contrary, the worker group showed high recognition in risk of working place, and felt that they are willing to compromise on safety for increasing production. The scale of the logistic center produced negative influence on awareness of safety. The group in small logistic center showed the highest awareness in safety, whereas the group in large logistic center with more than 100 workers showed the highest awareness in risk. They are more likely to deviate from correct and safe work procedures due to over-familiarity with the job, as well. The findings suggest that there is a need for the safety management and education to change the workers' understanding and attitudes towards safety.

Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner (CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가)

  • Kim, Sa-Hak;Kim, Jae-Hong;Kim, Chong-Kyen
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.673-678
    • /
    • 2015
  • The purpose of this study was to evaluate the reliability and accuracy of linear measurements in digital models compared to master model. A master model (ANKA-4; Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Four linear measurements were recorded between landmarks, directly on the master model and the digital models by a single examiner. Measurements were made with a digital caliper from manual model and with the software from the virtual models. The t-test for paired samples and intraclass correlation coefficient (ICC) were used for statistical analysis. The measurement of two methods showed good reliability. The mean differences between master and digital model were 0.06~0.12 mm. These in vitro studies show that accuracy and reliability of the digital impression is similar to that of the gold standard. Therefore digital impression was also considered to be a acceptable for placement clinically.

Influence of The Neck acupressure massage and The Neck Cream Including Korean Herbal Extract on The Neck Wrinkles and Facial Blood Circulation. (경항부 수기요법과 한방 목 크림이 목 주름과 안면 혈행에 미치는 영향 연구)

  • Kim, Eun-Joo;Kim, Ji-Seong;Yu, Sun-Hye;Rho, Ho-Sik;Kim, Duck-Hee;Kim, Han-Gon;Cho, Ga-Young
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.15 no.1
    • /
    • pp.85-91
    • /
    • 2009
  • Objectives: We investigated the influence of the neck acupressure massage and the neck cream including korean herbal extract on the neck wrinkles and blood circulation. Methods: Korean female($37.47{\pm}3.66$ years, n=18) aged 30-39 years were participated in this study. We measured the neck wrinkles with PRIMOS(GFMesstechnik GmbH, Germany) and blood circulation of neck and facial skin with Laser Doppler Imaging-Periscan PIM II(Perimed AB, Sweden). Results: The neck wrinkles were significantly decreased after applying neck cream. But when with the neck acupressure massage, the neck wrinkles were decreased 2-fold than applying only the neck cream. The skin blood circulation was significantly increased on the neck and facial skin immediately after the neck acupressure massage. But this effect was not significantly different after 8 weeks Conclusions: This result suggests that the neck acupressure massage can improve the anti-wrinkles effect of the neck cream including Korean herbal extract.

  • PDF

Pharmacological Therapies of Obesity: A Review of Current Treatment Options

  • Bacher, H.Peter;Shepherd, Gillian M.;Legler, Udo F.
    • Biomolecules & Therapeutics
    • /
    • v.17 no.4
    • /
    • pp.348-352
    • /
    • 2009
  • Over the last decade, the incidence of overweight and obesity has nearly doubled in many countries and is considered a pandemic. Obesity was identified as a major risk factor for cardiovascular disease as the same level as smoking and diabetes. Visceral fat is considered one of the key contributors to outcome and certain ethnic groups such as Asians seem to be more affected than others. Weight reduction through lifestyle changes was found to be impactful to improve overall health, but weight loss and maintenance thereof is limited and difficult to sustain. Surgical intervention demonstrated a greater weight loss in the severely obese and was associated with improved all-cause mortality. Despite numerous pharmacological targets and a high medical need, only few drugs have been successfully developed. Earlier studies with amphetamine-derived compounds showed significant weight loss but their critical safety profiles led to market withdrawals and disappointment. More recent compounds; orlistat - a lipase inhibitor, rimonabant - a cannaboid-1-receptor antagonist, and sibutramine - a combined serotonin/norepinephrine re-uptake inhibitor, all demonstrated similar significant efficacy; however, they carry specific safety profiles making them unsuitable for every patient. The main limitation of pharmacotherapy is the absence of clear benefit-risk assessments through outcome studies. Such a study - the SCOUT trial - was designed to compare sibutramine versus placebo and the effect on morbidity and mortality in nearly 10,000 obese patients with additional risk factors. Such studies could provide new scientific evidence for obesity treatment and may support future pharmacological approaches.

AFM fabrication of oxide patterns on 4H-SiC surface (4H-SiC 표면에서 AFM의 산화 패턴 제작)

  • Jo, Yeong-Deuk;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.64-64
    • /
    • 2009
  • Atomic force microscopy (AFM) fabrication of oxide patterns is an attractive technique for nanoscale patterns and related device structures, SiC exhibits good performance in high-power, high-frequency, and high-temperature conditions that is comparable to the performance of Si. The AFM fabrication of oxide patterns on SiC is important for electronic applications. However, there has not been much reported investigations on oxidation of SiC using AFM. We achieved the local oxidation of 4H-SiC using the high loading force of ~100 nN, although the oxidation of SiC is generally difficult mainly due to the physical hardness and chemical inactivity. All the experiments were performed using atomic force microscopy (S.I.S. GmbH, Germany) with a Pt/Ir-coated Si tip at ~40% humidity and room temperature. The spring constant and resonance frequency of the tip were around ~3 N/m and ~70 kHz. We fabricated oxide patterns on n-type 4H-SiC ($\sim10^{19}/cm^3$) and n-type Si ($\sim1.9\times10^{16}/cm^3$). In summary, we demonstrated that the oxide patterns can be obtained over the electric field of ${\sim}\times10^7 V/cm$ and the high loading force using the tip as a cathode. The electric field transports the oxyanions (OH-) to the positively biased surface.

  • PDF

Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy (레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.137-146
    • /
    • 2004
  • Laser Induced Breakdown Spectroscopy(LIBS) system is being developed as an in-situ analysis system for the radioactive waste glass in the cold crucible melter. In order to complete the LIBS system, a spectrometer, a detector, and a laser were structured. An ESA 3000 (LLA Instruments GmbH, Germany) including a calibrated Kodak KAF-1001 CCD detector was selected as the spectrometer. A Q-switched Nd-YAG Brilliant(Quantel, France) laser was selected as an energy source. As the first research stage, the excitation temperatures of Fe(I) as a function of the detector's delay intervals(500, 1000, 1500, 2000ns) were evaluated using the Einstein-Boltzmann equation. The optimized excitation temperature of Fe (I) was 7820k at the delay time of 1500㎱ using the 532nm Nd-YAG laser pulse. This LIBS system will be optimized under the real environment vitrification facility in the near future and then used to be in-situ analyzed the glass compositions in the melter qualitatively.

  • PDF

Experimental panoramic positioning errors for inducing condylar cutoff and superimposition of cervical vertebrae on the mandibular ramus (하악과두 잘림과 경추의 하악지 겹침을 야기하는 파노라마방사선촬영 오류)

  • Kang, Byung Cheol;Kim, Min Jong;Park, Hye Sun;Hwang, Sel Ae;Yoon, Suk Ja;Lee, Jae Seo
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.134-141
    • /
    • 2018
  • Purpose: To measure the head tilting angle creating initial condylar cut-off and to find the head position inducing the superimposition of the cervical vertebrae over the mandibular ramus on panoramic radiograph. Materials and Methods: The panoramic radiographs were taken with Didactic skull on cervical spine model (Scientific GmbH, Hamburg, Germany) using Kodak 8000c Digital Panoramic radiography. For the inherent radiolucency of the plastic skull model, radiopaque 1 mm diameter lead wires were attached along the margin of the mandibular condyle, ramus, mandibular body, cervical vertebrae, and FH plane of the skull model. For measuring the head tilting angle creating the condylar head cutoff, panoramic radiographs were taken by tilting the FH plane downward in 5 degree increments. For finding the distance between transverse process of the third cervical vertebra and gonion inducing superimposition of cervical vertebrae on the mandibular ramus, panoramic radiographs were taken by decreasing the distance in 0.5 cm increments. Result and Conclusion: The condylar cutoff began to appear when the head of skull model was tilted downward by 15o. As the head tilting angle increasing, the condylar cutoff became more prominent. The superimposition of cervical vertebrae over the mandibular ramus began to appear when the distance between the gonion and third cervical vertebra was 1.0 cm. As the distance decreasing, the superimpostion became more prominent.

  • PDF

Amelanotic Melanoma on Fingertip: A Case Report (수지첨부에 발생한 멜라닌결핍흑색종의 치험례)

  • Paik, Hye Won;Kim, Sang Wha;Byeon, Jun Hee
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.312-315
    • /
    • 2008
  • Purpose: Amelanotic melanoma represents a melanoma with an absence or a small number of melanin pigments and comprises 2% of all melanomas. These melanomas are frequently misdiagnosed, probably because of its nonspecific clinical features and difficulty in diagnosis, resulting in delayed diagnosis and treatment. We report a patient with amelanotic melanoma, who underwent surgical treatment with sentinel lymph node biopsy using gamma probe. Methods: A 32-year-old female was presented with a slowly growing ill-defined, hypopigmented nonerythematous lesion with nail defect on right index finger tip. Preoperative punch biopsy was performed, showing an amelanotic melanoma. Sentinel lymph node biopsy was done using gamma probe(Crystal probe system, CRYSTAL PHOTONICS GmbH, Germany) and confirmed no evidence of regional lymph node metastases. The patient underwent amputation at the proximal interphalangeal joint. Results: Histopathologic findings showed superficial spreading melanoma. There were no melanin pigments in Hematoxylin & Eosin stain but positive immunohistochemical stainings for S-100 protein and Hmb45, which were consistent with amelanotic melanoma. Patient's postoperative course was uneventful without any complication and had no evidence of recurrence of tumor in 6 months follow-up period. Conclusion: Amelanotic melanoma is extremely rare subtype of malignant melanoma with histopathologic findings of atypical melanocytes without melanin pigments. Early detection is crucial since survival is strongly related to tumor thickness and tissue invasion at the time of diagnosis. Wide excision is the treatment of choice and other conjunctive therapy has not been successful.