• Title/Summary/Keyword: GI cancer detection

Search Result 52, Processing Time 0.025 seconds

Findings of F-18 FDG Whole Body PET in Patients with Stomach Cancer (위암 환자에서 F-18 FDG 전신 PET의 소견)

  • Kim, Byung-Il;Lee, Jong-Inn;Yang, Won-Il;Lee, Jae-Sung;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.5
    • /
    • pp.301-312
    • /
    • 2001
  • Purpose: Stomach cancer is one of the most common malignancies in Korea, but there is no report on FDG PET in patients with stomach cancer. We observed findings of FDG PET in patients with stomach cancer. Materials and Methods: In 13 patients with pre-operative stomach cancer, PET and CT were performed. Primary lesion and regional lymph nodes detection were aualyzed. Correlation between FDG uptake ratio and each prognostic factor of primary lesion was analyzed. In 19 patients diagnosed as recurrence or displaying suspicious symptoms, conventional work up including tumor marker and PET were performed. Recurrence detection of anastomotic site, distant metastasis, and tumor marker elevation were analyzed. Results: Sensitivity for primary lesion detection was 83.3% (CT 71.4%) and two submucosal lesions were undetected. FDG uptake ratio was variable and had no correlation with invasion-depth, size, Borrmann type, staging and differentiation. Sensitivity for regional lymph node detection was 58.3% (CT 58.3%) and the lesions less than 1cm were undetected. Sensitivity for recurrence detection was 100% but there were three false positives. Sensitivity for distant metastasis detection was 64.3% and significantly higher than that of conventional work-up (21.4%). Average of tumor marker level in patients who were confirmed as recurrence was higher than false positive. Conclusion: PET is more useful than conventional work up in distant metastasis detection when recurrence is suspected. In pre-operative stomach cancer, PET is comparable to CT for detection of primary lesion and regional lymph node metastasis and detection of distant metastasis requires further study.

  • PDF

Development of Image-based System for Multiple Fluorescence Imaging Study (다중형광영상 연구를 위한 영상기반 시스템 개발)

  • Yoon, WoongBae;Kim, Hong Rae;Lee, Hyun Min;Kim, Young Jae;Kim, Kwang Gi;Yoo, Heon;Lee, Seung Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.12
    • /
    • pp.1445-1452
    • /
    • 2015
  • In these days, fluorescent materials such as ICG or 5-ALA is used for the brain surgery. The patients who underwent brain tumor surgery has been increased during last 30 years and the survivorship rate increased 22∼33% in 5 years. Recently, the Fluorescence induction surgery is developed for more safety and improved the resection rate for the glioma in the neurosurgery field. In this study, we proposed fluorescence area detection method for ICG and 5-ALA fluorescence induced surgery using acquired images from image processing. Accuracy was 99.21% from ICG images, and 99.51% from 5-ALA images. Matthews correlation coefficient was 88.67% from ICG images, and 90.49% from 5-ALA images.

Review of Neurosurgical Fluorescence Imaging Systems for Clinical Application

  • Kim, Hong Rae;Lee, Hyun Min;Yoo, Heon;Lee, Seung Hoon;Kim, Kwang Gi
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.305-313
    • /
    • 2016
  • A number of fluorescence imaging techniques for use in the surgical removal of glioma have been developed over the course of the long history of neurosurgery. Various biomarkers, biochemical agents, and detection systems for glioma have also been developed. This review focuses on 5-aminolevulinic acid (5-ALA), which is used to detect glioma. Numerous forms of fluorescence-guided surgery use 5-ALA, which is helpful to the surgeon. The surgical microscope system is the observational method generally used with 5-ALA, while the loupe, endoscope, and exoscope are simpler alternatives. A system is needed for minimal resection and other issues that arise during neurosurgery. Such an enhanced system should be able to detect low-grade tumors and provide information on microinvasive diseases, resulting in an improved survival rate and better surgical skills. Development of systems that fulfill certain needs would help protect the brain function of the patient and broaden the use of such systems in neurosurgery.

A Way for Maximum Use of Cancer Risk Assessment System CARA (암 발생 위험도 분석 시스템 CARA의 활용도 극대화 방안)

  • Yang, Gi-Chul;Cho, Kwang-Moon
    • Journal of Digital Convergence
    • /
    • v.10 no.3
    • /
    • pp.121-126
    • /
    • 2012
  • In this paper, a way for maximum use of cancer risk assessment software system CARA which can assess cancer risks by using health related information only without doctor's diagnosis is proposed. A way of maximizing the usage of CARA with use of nation wide internet network is described along with the general description of CARA. If CARA is used, the damage causing by cancer can be reduced since it is possible to sort a group of people with high risks (before diagnosis at a hospital). Also, CARA is helpful for medical research by used as a tool to reveal correlations between personal information and cancers practically. Unlike other preexisting systems, CARA is a new system which can consider 30 different cancers simultaneously and it is very efficient for early detection of cancer.

A Study on Micro-calcification Detection in Digital Mammography (디지털 맘모그래피에서 미소석회화 검출을 위한 연구)

  • Whi-Vin Oh;Young-Jae Kim;Kwang-gi Kim;Hyung-Seok Choi;Young-Wook Seo;Young-Ho Cho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.11a
    • /
    • pp.112-113
    • /
    • 2008
  • 유방암은 유럽과 미국을 비롯해 전 세계적으로 증가하고 있으며 최근 우리나라에서도 가장 급속하게 늘고 있는 여성암중에 하나이다. 본 연구에서는 먼저 grey level co-occurrence matrix(GLCM)을 적용하여 유방영역을 분할한 후, median filter 를 적용하여 잡음을 제거하였다. 전처리 수행 후, 2차미분 행렬을 이용할여 미소석회화 부분을 강조한 후, 가우시안 정규분포도를 적용하여 미소석회화 후보군을 검출하였다. 검출된 후보군은 8 개의 feature 들을 적용하여 미소석회화를 최종 결정하였다. 본 연구를 통해서 조기 유방암 진단을 위한 발전된 미소석회화 검출 방법을 제안하였다.

Development of a Semi-Automated Detection Method and a Classification System for Bone Metastatic Lesions in Vertebral Body on 3D Chest CT (3차원 흉부 CT에서 추체 골 전이 병변에 대한 반자동 검출 기법 및 분류 시스템 개발)

  • Kim, Young Jae;Lee, Seung Hyun;Choi, Ja Young;Sun, Hye Young;Kim, Kwang Gi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.10
    • /
    • pp.887-895
    • /
    • 2013
  • Metastatic bone cancer, the cancer which occurred in the various organs and progressively spread to bone, is one of the complications in cancer patients. This cancer is divided into the osteoblast and osteolytic metastasis. Although Computer Tomography(CT) could be an useful tool in diagnosis of bone metastasis, lesions are often missed by the visual inspection and it makes clinicians difficult to detect metastasis earlier. Therefore, in this study, we construct a three-dimensional(3D) volume rendering data from tomography images of the chest CT, and apply a 3D based image processing algorithm to them for detection bone metastasis lesions. Then we perform a three-dimensional visualization of the detected lesions.From our test using 10 clinical cases, we confirmed 94.1% of average sensitivity for osteoblast, and 90.0% of average sensitivity, respectively. Consequently, our findings showed a promising possibility and potential usefulness in diagnosis of metastastic bone cancer.

Development of an RNA sequencing panel to detect gene fusions in thyroid cancer

  • Kim, Dongmoung;Jung, Seung-Hyun;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.19 no.4
    • /
    • pp.41.1-41.10
    • /
    • 2021
  • In addition to mutations and copy number alterations, gene fusions are commonly identified in cancers. In thyroid cancer, fusions of important cancer-related genes have been commonly reported; however, extant panels do not cover all clinically important gene fusions. In this study, we aimed to develop a custom RNA-based sequencing panel to identify the key fusions in thyroid cancer. Our ThyChase panel was designed to detect 87 types of gene fusion. As quality control of RNA sequencing, five housekeeping genes were included in this panel. When we applied this panel for the analysis of fusions containing reference RNA (HD796), three expected fusions (EML4-ALK, CCDC6-RET, and TPM3-NTRK1) were successfully identified. We confirmed the fusion breakpoint sequences of the three fusions from HD796 by Sanger sequencing. Regarding the limit of detection, this panel could detect the target fusions from a tumor sample containing a 1% fusion-positive tumor cellular fraction. Taken together, our ThyChase panel would be useful to identify gene fusions in the clinical field.

Cell-Free miR-27a, a Potential Diagnostic and Prognostic Biomarker for Gastric Cancer

  • Park, Jong-Lyul;Kim, Mirang;Song, Kyu-Sang;Kim, Seon-Young;Kim, Yong Sung
    • Genomics & Informatics
    • /
    • v.13 no.3
    • /
    • pp.70-75
    • /
    • 2015
  • MicroRNAs (miRNAs) have been demonstrated to play an important role in carcinogenesis. Previous studies revealed that miRNAs are present in human plasma in a remarkably stable form that is protected from endogenous RNase activity. In this study, we measured the plasma expression levels of three miRNAs (miR-21, miR-27a, and miR-155) to investigate the usefulness of miRNAs for gastric cancer detection. We initially examined plasma miRNA expression levels in a screening cohort consisting of 15 patients with gastric cancer and 15 healthy controls from Korean population, using TaqMan quantitative real-time polymerase chain reaction. We observed that the expression level of miR-27a was significantly higher in patients with gastric cancer than in healthy controls, whereas the miR-21 and miR-155a expression levels were not significantly higher in the patients with gastric cancer. Therefore, we further validated the miR-27a expression level in 73 paired gastric cancer tissues and in a validation plasma cohort from 35 patients with gastric cancer and 35 healthy controls. In both the gastric cancer tissues and the validation plasma cohort, the miR-27a expression levels were significantly higher in patients with gastric cancer. Receiver-operator characteristic (ROC) analysis of the validation cohort, revealed an area under the ROC curve value of 0.70 with 75% sensitivity and 56% specificity in discriminating gastric cancer. Thus, the miR-27a expression level in plasma could be a useful biomarker for the diagnosis and/or prognosis of gastric cancer.

Spatial Analysis of Breast Cancer Incidence in Iran

  • Mahdavifar, Neda;Pakzad, Reza;Ghoncheh, Mahshid;Pakzad, Iraj;Moudi, Asieh;Salehiniya, Hamid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.59-64
    • /
    • 2016
  • Breast cancer (BC) is the most common cancer in females (27% of the total) and the main cause of death (16%) due to cancer in women in developed and developing countries. Variations in its incidence rate among geographical areas are due to various contributing factors. Since there have been a lack of studies on this topic in our country, the present spatial analysis of breast cancer incidence in Iran in 2009 was conducted using data from the national cancer registry system. The reported incidences of the disease were standardized according to the World Health Organization population and the direct method. Then data was inserted into the GIS software and finally, using the Hot Spot Analysis (Geties-Ord Gi), high-risk areas were drawn. Provinces with incidences 1.96 SD higher or lower than the national average were considered as hot spots or cold spots, at the significance level of 0.05%. In 2009, a total of 7,582 cases of BC occurred in Iran. The annual incidence was 33.2 per hundred thousand people. Our study showed that the highest incidence of BC in women occurred in the central provinces of the country, Tehran, Isfahan, Yazd, Markazi and Fars. The results of hot spots analysis showed that the distribution of high-risk BC was focused in central parts of Iran, especially Isfahan province (p <0.01). The other provinces were not significantly different from the national average. The higher incidence in central provinces may be due to greater exposure to carcinogens in urban areas, a Western lifestyle and high prevalence of other risk factors. Further epidemiological studies about the etiology and early detection of BC are essential.

Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope (수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구)

  • Lee, Hyun Min;Kim, Hong Rae;Yoon, Woong Bae;Kim, Young Jae;Kim, Kwang Gi;Kim, Seok Ki;Yoo, Heon;Lee, Seung Hoon;Shin, Min Sun;Kwon, Ki Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we propose a microscope system for detecting both a tumor and blood vessels in brain tumor surgery as fluorescence images by using multiple light sources and a beam-splitter module. The proposed method displays fluorescent images of the tumor and blood vessels on the same display device and also provides accurate information about them to the operator. To acquire a fluorescence image, we utilized 5-ALA (5-aminolevulinic acid) for the tumor and ICG (Indocyanine green) for blood vessels, and we used a beam-splitter module combined with a microscope for simultaneous detection of both. The beam-splitter module showed the best performance at 600 nm for 5-ALA and above 800 nm for ICG. The beam-splitter is flexible to enable diverse objective setups and designed to mount a filter easily, so beam-splitter and filter can be changed as needed, and other fluorescent dyes besides 5-ALA and ICG are available. The fluorescent images of the tumor and the blood vessels can be displayed on the same monitor through the beam-splitter module with a CCD camera. For ICG, a CCD that can detect the near-infrared region is needed. This system provides the acquired fluorescent image to an operator in real time, matching it to the original image through a similarity transform.