• Title/Summary/Keyword: GHP

Search Result 109, Processing Time 0.027 seconds

Data Mining-Based Performance Prediction Technology of Geothermal Heat Pump System (지열 히트펌프 시스템의 데이터 마이닝 기반 성능 예측 기술)

  • Hwang, Min Hye;Park, Myung Kyu;Jun, In Ki;Sohn, Byonghu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • This preliminary study investigated data mining-based methods to assess and predict the performance of geothermal heat pump(GHP) system. Data mining is a key process of the knowledge discovery in database (KDD), which includes five steps: 1) Selection; 2) Pre-processing; 3) Transformation; 4) Analysis(data mining); and 5) Interpretation/Evaluation. We used two analysis models, categorical and numerical decision tree models to ascertain the patterns of performance(COP) and electrical consumption of the GHP system. Prior to applying the decision tree models, we statistically analyzed measurement database to determine the effect of sampling intervals on the system performance. Analysis results showed that 10-min sampling data for the performance analysis had highest accuracy of 97.7% over the actual dataset of the GHP system.

Heating Performance of Geothermal Heat Pump System Applied in Cold Climate Region(Mongolia) (한랭지(몽골) 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu;Choi, Jae Ho;Min, Kyung Chon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Geothermal heat pump (GHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. These systems use the ground as a heat source in heating mode operation and a heat sink in cooling mode operation. The aim of this study is to evaluate the heating performance of the GHP system for a residential building ($420m^2$) in Ulaanbaatar, Mongolia. In order to demonstrate the feasibility of a sustainable performance of this system, we installed the water-to-water geothermal heat pump with ten vertical ground heat exchangers and measured operation parameters from October 19, 2013 to March 26, 2014. The results showed that the entering source temperature of brine from the ground heat exchangers was in a range of the design target temperature of $-10^{\circ}C$ for heating. For total values of the representative results, the ground heat exchangers extracted heat of 53.51 MWh from the ground. In addition, the GHP system supplied heat of 83.55 MWh to the building and consumed power of 30.27 MWh. Consequently, the average heating seasonal performance factor ($SPF_h$) of the overall system was evaluated to be 2.76 during the measurement period of the heating season.

A Study on Estimating Real-time Thermal Load During GHP Operation in Heating Mode (GHP 난방 모드 운전시 실시간 부하 추정방법에 관한 연구)

  • Seo, Jeong-A;Shin, Young-Gy;Oh, Se-Je;Jeong, Sang-Duck;Ji, Kyoung-Chul;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • The present study has been conducted to propose an algorithm regarding real-time load estimation of a gas engine-driven heat pump. In the study, thermal load of an indoor unit is estimated in terms of air-side and refrigerant-side. The air-side estimation is based on a typical heat exchanger model and is found to be in good agreement with experimental data. When it comes to the refrigerant-side load, a pressure difference across a valve must be estimated. For the estimation, it is assumed to be proportional to a bigger pressure difference that is available either by measurement or by estimation. Relative good agreement between the air- and refrigerant-sides suggests that the assumption may be plausible for the load estimation. The summed flow rate of all of indoor units is in good agreement with the throughput of the compressor which are calculated from the manufacturer's software. Accordingly, estimated thermal loads are also in good agreement. The proposed algorithm may be further developed for improved control algorithm and fault diagnosis.

Experimental Study on Correction of Thermal Conductivity Obtained by Heat Flow Method using Commercial Guarded Hot Plate Method Apparatus (상용 보호열판법 열전도율 측정장비를 사용한 열유속법의 열전도율 값 보정에 대한 실험적 연구)

  • Lee, Jin-Sung;Kim, Kyung-Su;Kim, Yooil;Woo, Suck-Min;Yun, Seungjin
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.169-174
    • /
    • 2015
  • This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.

세계적 에너지설비 기술서비스 기업으로 거듭난다

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.16
    • /
    • pp.22-25
    • /
    • 2002
  • 한국가스공사의 자회사로서 천연가스의 생산, 공급설비를 전문으로 취급하는 한국가스기술공업㈜는 지난 7년여동안 고도의 가스설비 전문기술력 배양을 위해 집중적 투자와 교육훈련을 실시해 왔으며, 기술경쟁력 강화와 경영혁신운동 추진으로 세계적인 에너지설비 기술서비스 기업으로 거듭나고자 한다. 더욱이 조명과 인버터에 치중해있던 ESCO사업 분야도 GHP와 CES로의 확장을 모색하는 등 발길이 분주하다.

  • PDF

강원지역 대표 ESCO 에너지토털서비스 기업으로 확장

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.17
    • /
    • pp.22-25
    • /
    • 2002
  • 강원도 원주에 위치한 엘레코전자는 지난 2000년 설립 이후 조도개선 사업을 주력업종으로 시작하여, 최근에는 GHP와 폐열회수기로의 아이템 전환을 시도하고 있다. 강원지역에서의 성공적인 ESCO 사업을 발판으로 향후 조명설비 제조에서부터 진단, 시공에 이르기까지 전반적인 에너지업무를 수행할 수 있도록 에너지 종합 시스템을 갖춘 기업으로 성장하는 것이 이들의 목표이다.

  • PDF

냉난방기기의 에너지 효율 및 이산화탄소 배출 비교 분석

  • Jeong, Si-Yeong;Park, Yun-Cheol
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.11
    • /
    • pp.22-26
    • /
    • 2010
  • 660 $m^2$(200평) 상업용 건물을 기준하여 멀티히트펌프와 GHP를 포함한 냉난방기기의 에너지 효율과 이산화탄소 배출 특성을 비교 분석.

  • PDF

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF