• 제목/요약/키워드: GHA

검색결과 91건 처리시간 0.028초

Detailed Investigation on Factors Governing Liquid Crystal Alignment on Rubbed Polystyrene Films

  • Hahm, Seok-Gyu;Lee, Taek-Joon;Lee, Seung-Woo;Yoon, Jin-Hwan;Kim, Gha-Hee;Chang, Tai-Hyun;Ree, Moon-Hor
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.899-902
    • /
    • 2004
  • The molecular reorientations and surface morphologies of rubbed films formed from atactic polystyrene (PS) samples with various molecular weights were investigated in detail. Previously unknown surface topography features were newly discovered in rubbed films, depending on molecular weights: submicroscale groove-like meandering structures composed of fine-grooves like pebbles in tens nanometers are present, oriented perpendicular to the rubbing direction. The vinyl main chains, however, were preferentially reoriented along the rubbing direction and the planes of the phenyl side groups were preferentially reoriented perpendicular to the rubbing direction with para-directions that were positioned nearly normal to the film plane. Nematic liquid crystal (LC) molecules were found to always align on the rubbed PS surfaces along the orientation direction of the submicroscale grooves generated by rubbing.

  • PDF

Properties of Malonyl-CoA Decarboxylase from Rhizobium trifolii

  • An, Jae-Hyung;Lee, Gha-Young;Song, Jong-Hee;Lee, Dai-Woon;Kim, Yu-Sam
    • BMB Reports
    • /
    • 제32권4호
    • /
    • pp.414-418
    • /
    • 1999
  • A novel gene for malonyl-CoA decarboxylase was discovered in the mat operon, which encodes a set of genes involved in the malonate metabolism of Rhizobium trifolii (An and Kim, 1998). The subunit mass determined by SDS-PAGE was 53 kDa, which correspond to the deduced mass from the sequence data. The molecular mass of the native enzyme determined by field flow fractionation was 208 kDa, indicating that R. trifolii malonyl-CoA decarboxylase is homotetrameric. R. trifolii malonyl-CoA decarboxylase converted malonyl-CoA to acetyl-CoA with a specific activity of 100 unit/mg protein. Methylmalonyl-CoA was decarboxylated with a specific activity of 0.1 unit/mg protein. p-Chloromercuribenzoate inhibited this enzyme activity, suggesting that thiol group(s) is(are) essential for this enzyme catalysis. Database analysis showed that malonyl-CoA decarboxylase from R. trifolii shared 32.7% and 28.1% identity in amino acid sequence with those from goose and human, respectively, and it would be located in the cytoplasm. However, there is no sequence homology between this enzyme and that from Saccharopolyspora erythreus, suggesting that malonyl-CoA decarboxylases from human, goose, and R. trifolii are in the same class, whereas that from S. erythreus is in a different class or even a different enzyme, methylmalonyl-CoA decarboxylase. According to the homology analysis, Cys-214 among three cysteine residues in the enzyme was found in the homologous region, suggesting that the cysteine was located at or near the active site and plays a critical role in catalysis.

  • PDF

국제여객터미널 대합실의 환경요소와 감정, 만족도 간의 영향 관계 (The Effect of the Environmental Factor on the Emotion and Satisfaction at the Waiting Lounge of the International Cruise Terminal)

  • 김가령;양위주
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2014년도 춘계학술대회
    • /
    • pp.210-211
    • /
    • 2014
  • 본 연구는 국제여객터미널 대합실의 환경요소와 감정, 만족 간의 영향관계에 대하여 알아보고자 하였다. 구조모형 검증결과 첫째, 대합실의 물리적 환경요소는 감정에 정(+)의 영향을 미치는 것으로 나타났다. 둘째, 대합실의 사회적 환경요소는 감정에 정(+)의 영향을 미치는 것으로 나타났다. 셋째, 감정은 만족도에 정(+)의 영향을 미치는 것으로 나타났다. 따라서 환경적 요소는 감정에 영향을 미치는 중요한 요소이므로 장소의 특성에 따라 환경적 요소들에 대한 관리가 요구된다. 또한 환경적 요소는 감정을 매개로 만족도에 영향을 미치게 되므로 관광객들의 감정에 부정적 영향을 미치지 않도록 국제여객터미널 관련 주체는 대합실 환경에 대한 지속적인 관심과 관광객들의 이용 만족도를 향상 시킬 수 있는 환경마련에 노력해야 할 것이다.

  • PDF

이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구 (Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator)

  • 구본열;김가중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Li-K-Cd 합금을 이용한 LiCl-KCl 용융염에서 금속염화물의 제거 (Use of Li-K-Cd Alloy to Remove MCl3 in LiCl-KCl Eutectic Salt)

  • 김가영;김택진;장준혁;김시형;이창화;이성재
    • 방사성폐기물학회지
    • /
    • 제16권3호
    • /
    • pp.309-313
    • /
    • 2018
  • Li-Cd 합금을 이용한 환원추출방식을 LiCl-KCl 기반의 drawdown 공정에 적용하게 되면, LiCl-KCl 공융염의 조성이 파괴되므로 공정온도를 높여야 하며, 전해정련 및 전해제련과 같은 공정에 LiCl-KCl 용융염을 재사용할 수 없게 된다. 따라서, 본 연구에서는 공융염 조성에 적합한 Li-K-Cd 합금을 제조하였으며, 이를 이용하여 U와 Nd가 포함된 LiCl-KCl 염에 투입하여 용융염 내 $UCl_3$의 제거가 가능한지 평가하였다.

가토의 신장기능과 Renin분비에 미치는 Adenosine Analogues의 영향 (Effect of Adenosine Analogues on the Renal Function and Renin Release)

  • 송윤식;최병수;김선희;조경우
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.319-332
    • /
    • 1988
  • The regulations of renal function and renin release are influenced by neural, humoral and physical factors. During the last decade, considerable progress has been made in the identification and characterization of these extrinsic renal control systems. Mechanisms intrinsic to the kidney are also important for renal function. These include the autoregulation of blood flow, and the local control of renin secretion. Fundamental questions regarding the mechanism of these intrinsic controls remain unanswered. Recently, endogenous renal adenosine has been claimed to influence the tubuloglomerular feedback control and renin release. Two subclasses of adenosine receptors $A_1{\;}and{\;}A_2$ have been described. The present experiment was carried out to evaluate the effects of $N_6-cyclohexyladenosine$ $(CHA,{\;}A_1{\;}selective)$ and 5'-N-ethylcarbox-amide adenosine $(NECA,{\;}A_2{\;}selective)$ on the renal function and renin release in the unanesthetized rabbit. Intra-renal arterial infusion of NECA $(0.3{\sim}10.0n{\;}mole/min/rabbit)$ or CHA $(0.03{\sim}10.0n{\;}mole/min/rabbit)$ caused a prompt and dose-dependent decrease in urine volume, glomerular filtration rate (GFR), renal plasma flow (RPF), filtration fraction (FF), electrolyte excretion and free water clearance $(CH_2O)$, the effect being much more profound with CHA than with NECA. The NECA infusion resulted in a profound decrease of systemic blood pressure, but the CHA infusion did not. Both NECA and GHA infusions caused a prompt and dose-dependent decrease in renin secretion rate, again the effect being greater with CHA than with NEGA. These results suggest that both $A_1{\;}and{\;}A_2$ adenosine receptors may be involved in the intrinsic control of renal function and renin release, and that the $A_1$ receptors plays a more important role than the $A_2$ receptor in the regulation of renal fnction.

  • PDF

Chip소자를 이용한 SSPA 설계 및 제작에 관한 연구 (The Design and Implementation of SSPA(Solid State Power Amplifier) using chip device)

  • 김용환;민준기;김현진;유형수;이형규;홍의석
    • 한국ITS학회 논문지
    • /
    • 제2권2호
    • /
    • pp.65-72
    • /
    • 2003
  • 본 연구를 통하여 MMC(Microwave Micro Cell)를 위한 무선 중계 시스템과 ITS용 무선장비등에 사용 될 수있는 6단의 하이브리드 전력증폭기를 설계 및 제작하였다. 전력 증폭기 각단의 능동소자는 bare chip 형태의 Hetero-junction Power FET를 이용하였으며, $\varepsilon_{r}$=9.9, 15-mil 두께의 알루미나기판을 사용하여 제작하였다. 측정 결과 시스템의 순방향 주파수인 17.6GHz - 17.gGEU에서 33.2~36.5dB의 소신호 이득과 33.0$\~$34.0dBm까지의 출력전력을 얻었고, 역방향 주파수인 19.0GHt$\~$19.2GHz에서 36.0$\~$37.0dB의 소신호 이득을 출력전력은 33.0$\~$34.5dBm을 얻었다.

  • PDF

방사선사의 손 씻기 관리와 개인위생관리의 실태조사 (Actual Condition Investigation of Radiologist on the Hand Washing Management and Personal Hygiene Management)

  • 한상현;홍동희;김가중
    • 한국콘텐츠학회논문지
    • /
    • 제12권1호
    • /
    • pp.409-415
    • /
    • 2012
  • 본 연구의 목적은 방사선사의 병원감염관리 중 손 씻기 관리와 개인위생관리에 관한 인식도와 실천도를 조사하여 병원감염예방에 대한 실태를 조사하기 위해 실시 되었다. 그 결과로는 방사선사의 손 씻기 관리의 인식도와 실천도는 5점 만점을 기준으로 4.378, 4.199 이었고, 개인위생관리의 인식도와 실천도는 5점 만점을 기준으로 4.284, 3.990 이었다. 또한 손 씻기 관리의 인식도에서 일반적 특성 중 성별, 연령, 학력, 근무경력이 유의한 차이가 있었으며, 실천도에서는 성별, 결혼여부가 유의한 차이가 있었다. 개인위생관리의 인식도에서 일반적 특성 중 연령, 학력, 근무경력이 유의한 차이가 있었으며, 실천도에서는 결혼여부, 근무경력이 유의한 차이가 있었다. 마지막으로, 손 씻기 관리와 개인위생관리의 인식도와 실천도의 상관관계는 손씻기 관리 r=0.453, 개인위생관리 r=0.415로 인식도가 높을수록 실천도가 높게 나타났다.

영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구 (A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT))

  • 김가중;류준민;최준구;홍동희
    • 한국콘텐츠학회논문지
    • /
    • 제16권1호
    • /
    • pp.75-81
    • /
    • 2016
  • 최근 방사선 치료 분야에서는 다양한 영상유도 방사선 치료(IGRT) 장치들을 이용한 환자 셋업으로 고도의 정밀성이 보장된 치료가 가능해 졌다. 그러나 환자의 정상 조직에 받는 추가 선량 또한 더불어 증가되고 있다. 이에 본 연구에서는 영상유도 방사선 치료 장치 중 OBI, CBCT, ExacTrac를 이용한 환자 셋업에 주변 정상 조직에 받는 피폭선량을 측정하였다. 결과 팬텀 중심부의 선량이 CBCT의 경우 두부 12.57 mGy, 흉부 20.82 mGy, 복부 82.93 mGy, 골반부위 52.70 mGy로 측정되었으며 OBI는 0.76 ~ 8.58 mGy, ExacTrac의 경우 0.14 ~ 0.63 mGy로 CBCT의 피폭선량이 다른 장비에 비해 월등히 높게 나타나는 것을 알 수 있었다. 표면 선량의 경우에서도 CBCT가 다른 장비에 비해 높게 나타났으나 입사 피부표면 선량(Enterance skin dose)의 경우 OBI도 CBCT의 피폭선량과 거의 비슷한 흡수선량이 측정 되었다.

하상여과용 다직경 수평집수관의 효능에 대한 실험연구 (An Experimental Study on the Performance of Multi-Diameter Lateral for Riverbed Filtration)

  • 배가람;김승현
    • 대한환경공학회지
    • /
    • 제34권5호
    • /
    • pp.359-364
    • /
    • 2012
  • 장대형 수평집수관은 내부에서 축방향 흐름에 대한 마찰저항으로 인해 우물효율이 낮아지므로 이를 방지하기 위하여 다직경 수평집수관을 제안하였고, 그 효능을 평가하기 위해 실험실 규모의 모래통 실험을 수행하였다. 실험에서는 다직경과 여러 직경의 단직경 집수관에 대해 산출유량을 달리하면서 집수관에서의 수두분포를 파악하였으며, 이를 통해서 집수관의 효능을 평가하였다. 연구결과 다직경 집수관은 단직경에 비해 재료비가 1/3 이상 절감되면서도 그 산출유량은 최대직경의 단직경 집수관의 93% 이상이어서 그 효능이 우수함을 알 수 있었다. 또한, 출구유속이 약 0.8 m/sec 이상에서는 수평집수관의 수두분포가 왜곡되어 수리학적으로 비효율적인 수평우물임을 알 수 있었다.