• Title/Summary/Keyword: GHA

Search Result 91, Processing Time 0.032 seconds

Detailed Investigation on Factors Governing Liquid Crystal Alignment on Rubbed Polystyrene Films

  • Hahm, Seok-Gyu;Lee, Taek-Joon;Lee, Seung-Woo;Yoon, Jin-Hwan;Kim, Gha-Hee;Chang, Tai-Hyun;Ree, Moon-Hor
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.899-902
    • /
    • 2004
  • The molecular reorientations and surface morphologies of rubbed films formed from atactic polystyrene (PS) samples with various molecular weights were investigated in detail. Previously unknown surface topography features were newly discovered in rubbed films, depending on molecular weights: submicroscale groove-like meandering structures composed of fine-grooves like pebbles in tens nanometers are present, oriented perpendicular to the rubbing direction. The vinyl main chains, however, were preferentially reoriented along the rubbing direction and the planes of the phenyl side groups were preferentially reoriented perpendicular to the rubbing direction with para-directions that were positioned nearly normal to the film plane. Nematic liquid crystal (LC) molecules were found to always align on the rubbed PS surfaces along the orientation direction of the submicroscale grooves generated by rubbing.

  • PDF

Properties of Malonyl-CoA Decarboxylase from Rhizobium trifolii

  • An, Jae-Hyung;Lee, Gha-Young;Song, Jong-Hee;Lee, Dai-Woon;Kim, Yu-Sam
    • BMB Reports
    • /
    • v.32 no.4
    • /
    • pp.414-418
    • /
    • 1999
  • A novel gene for malonyl-CoA decarboxylase was discovered in the mat operon, which encodes a set of genes involved in the malonate metabolism of Rhizobium trifolii (An and Kim, 1998). The subunit mass determined by SDS-PAGE was 53 kDa, which correspond to the deduced mass from the sequence data. The molecular mass of the native enzyme determined by field flow fractionation was 208 kDa, indicating that R. trifolii malonyl-CoA decarboxylase is homotetrameric. R. trifolii malonyl-CoA decarboxylase converted malonyl-CoA to acetyl-CoA with a specific activity of 100 unit/mg protein. Methylmalonyl-CoA was decarboxylated with a specific activity of 0.1 unit/mg protein. p-Chloromercuribenzoate inhibited this enzyme activity, suggesting that thiol group(s) is(are) essential for this enzyme catalysis. Database analysis showed that malonyl-CoA decarboxylase from R. trifolii shared 32.7% and 28.1% identity in amino acid sequence with those from goose and human, respectively, and it would be located in the cytoplasm. However, there is no sequence homology between this enzyme and that from Saccharopolyspora erythreus, suggesting that malonyl-CoA decarboxylases from human, goose, and R. trifolii are in the same class, whereas that from S. erythreus is in a different class or even a different enzyme, methylmalonyl-CoA decarboxylase. According to the homology analysis, Cys-214 among three cysteine residues in the enzyme was found in the homologous region, suggesting that the cysteine was located at or near the active site and plays a critical role in catalysis.

  • PDF

The Effect of the Environmental Factor on the Emotion and Satisfaction at the Waiting Lounge of the International Cruise Terminal (국제여객터미널 대합실의 환경요소와 감정, 만족도 간의 영향 관계)

  • Kim, Gha-Ryong;Yhang, Wii-Joo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.06a
    • /
    • pp.210-211
    • /
    • 2014
  • The study was to investigate the effect of the environmental factor on the emotion and satisfaction at the waiting lounge of the international cruise terminal. The results of the study were found as follows: first, the physical environmental factor of the lounge influenced on the positive emotion. Second, the social factor affected the positive emotion. Finally, emotion affected the positive satisfaction. This study suggested that environmental factor was totally affected by emotion and thus environmental management depended on an individual characteristics of the individual place. The port authority will need more efforts to make a better waiting lounge setting for higher tourist satisfaction.

  • PDF

Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator (이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구)

  • Koo, Bon-Yeoul;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Use of Li-K-Cd Alloy to Remove MCl3 in LiCl-KCl Eutectic Salt (Li-K-Cd 합금을 이용한 LiCl-KCl 용융염에서 금속염화물의 제거)

  • Kim, Gha-Young;Kim, Tack-Jin;Jang, Junhyuk;Kim, Si-Hyung;Lee, Chang Hwa;Lee, Sung-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.309-313
    • /
    • 2018
  • In this study, we prepared Li-K-Cd alloy, which meets the requirement of eutectic ratio of Li:K, to maintain the operating temperature of the drawdown process at $500^{\circ}C$ and to achieve the reuse of LiCl-KCl molten salt. The prepared Li-K-Cd alloys were added to LiCl-KCl salt bearing U and Nd at $500^{\circ}C$ to investigate the removal of $UCl_3$ in the salt. The reduction of $UCl_3$ in the salt was examined by measuring the OCP value of salt and analyzing the salt composition by ICP-OES. Reduction was also visually confirmed by change of salt color from dark purple to white. The experimental results reveal that the prepared Li-K-Cd alloy has reductive extractability for $UCl_3$ in salt. By improving the preparation method, the Li-K-Cd alloy can be applied to the drawdown process.

Effect of Adenosine Analogues on the Renal Function and Renin Release (가토의 신장기능과 Renin분비에 미치는 Adenosine Analogues의 영향)

  • Song, Yun-Sik;Choi, Byung-Soo;Kim, Suhn-Hee;Cho, Kyung-Woo
    • The Korean Journal of Physiology
    • /
    • v.22 no.2
    • /
    • pp.319-332
    • /
    • 1988
  • The regulations of renal function and renin release are influenced by neural, humoral and physical factors. During the last decade, considerable progress has been made in the identification and characterization of these extrinsic renal control systems. Mechanisms intrinsic to the kidney are also important for renal function. These include the autoregulation of blood flow, and the local control of renin secretion. Fundamental questions regarding the mechanism of these intrinsic controls remain unanswered. Recently, endogenous renal adenosine has been claimed to influence the tubuloglomerular feedback control and renin release. Two subclasses of adenosine receptors $A_1{\;}and{\;}A_2$ have been described. The present experiment was carried out to evaluate the effects of $N_6-cyclohexyladenosine$ $(CHA,{\;}A_1{\;}selective)$ and 5'-N-ethylcarbox-amide adenosine $(NECA,{\;}A_2{\;}selective)$ on the renal function and renin release in the unanesthetized rabbit. Intra-renal arterial infusion of NECA $(0.3{\sim}10.0n{\;}mole/min/rabbit)$ or CHA $(0.03{\sim}10.0n{\;}mole/min/rabbit)$ caused a prompt and dose-dependent decrease in urine volume, glomerular filtration rate (GFR), renal plasma flow (RPF), filtration fraction (FF), electrolyte excretion and free water clearance $(CH_2O)$, the effect being much more profound with CHA than with NECA. The NECA infusion resulted in a profound decrease of systemic blood pressure, but the CHA infusion did not. Both NECA and GHA infusions caused a prompt and dose-dependent decrease in renin secretion rate, again the effect being greater with CHA than with NEGA. These results suggest that both $A_1{\;}and{\;}A_2$ adenosine receptors may be involved in the intrinsic control of renal function and renin release, and that the $A_1$ receptors plays a more important role than the $A_2$ receptor in the regulation of renal fnction.

  • PDF

The Design and Implementation of SSPA(Solid State Power Amplifier) using chip device (Chip소자를 이용한 SSPA 설계 및 제작에 관한 연구)

  • Kim Yong-Hwan;Min Jun-ki;Kim HyunJin;Yoo Hyeong-soo;Lee Hyeong-kyu;Hong Ui-seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.2 no.2 s.3
    • /
    • pp.65-72
    • /
    • 2003
  • In this work a 6-stage hybrid power amplifier which can be used for the wireless communication systems for MMC(hficrowave Micro Cell) and ITS wireless communication system is designed and fabricated. Ihe power amplifier's each stages was fabricated Hetero-junction Power FET of bare chip type and an alumina substrate with $\varepsilon_{r}$=9.9 and 15-mil thickness. The measured results of power amplifier module showed 33.2$\~$36.5 dB small signal gain, 33.0$\~$34.0 dBm output power at forward frequency (17.6 GHa $\~$ 17.9 CHz) and 36.0$\~$37.0 dB small signal gain, 33.0$\~$34.5 dBm output power at reverse frequency (19.0 GHz $\~$19.2GHz).

  • PDF

Actual Condition Investigation of Radiologist on the Hand Washing Management and Personal Hygiene Management (방사선사의 손 씻기 관리와 개인위생관리의 실태조사)

  • Han, Sang-Hyun;Hong, Dong-Hee;Kim, Gha-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.1
    • /
    • pp.409-415
    • /
    • 2012
  • The purpose of this study is to know the status of management of nosocomial infection and to present basic data for improving management of nosocomial infection. As a result, the average score of the recognition and performance of radiologist on the management of hand washing is 4.378, and 4.199 of 5. The average score of the recognition and performance of radiologist on the management of personal hygiene is 4.284, and 3.990 of 5. The recognition of hand washing management according to the general character, statistically significant difference according to the gender, age, education, career. In the performance is statistically significant difference according to the gender, marriage situation. In the recognition of personal hygiene management according to the general character, statistically significant difference according to the age, education, career. Performance of statistically significant difference according to the marriage situation, career. Finally, statistically significant difference between recognition and performance of radiologists on management of hand washing(r=0.453, p=0.000) and personal hygiene(r=0.415, p=0.000).

A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT) (영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구)

  • Kim, Gha-Jung;Ryu, Jun-Min;Choi, Jun-Gu;Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.75-81
    • /
    • 2016
  • The recent radiation therapy field can provide treatment which guarantees a high degree of accuracy, due to patient set-up using various image guided radiation therapy(IGRT) instruments. But the additional absorbed dose to patient's normal tissues is increasing. Therefore, this study measured the absorbed dose to surrounding normal tissues which is caused by patient set-up using OBI, CBCT, ExacTrac, among various IGRT instruments. The absorbed dose to the head, the chest, the abdomen, and the pelvis from CBCT was 12.57 mGy, 20.82 mGy, 82.93 mGy, and 52.70 mGy, respectively. Also, the absorbed dose from OBI and ExacTrac ranged from 0.76 to 8.58 mGy and from 0.14 to 0.63 mGy, respectively. As a result, CBCT's absorbed dose was far higher than other instruments. CBCT's surface dose was far higher than others, too, but OBI's entrance skin dose was almost the same as CBCT's.

An Experimental Study on the Performance of Multi-Diameter Lateral for Riverbed Filtration (하상여과용 다직경 수평집수관의 효능에 대한 실험연구)

  • Bae, Gha-Ram;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.359-364
    • /
    • 2012
  • In order to prevent the decrease in well efficiencies due to friction in the axial flow in long, large-diameter laterals, a multi-diameter lateral was devised and tested through lab-scale sand-box experiments to assess its performance. In the experiment, three different production rates were applied over the multi-diameter and the three single-diameter laterals to obtain the hydraulic head distributions for each, which was used to assess the performance of the laterals. Results elucidated that the multi-diameter lateral reduced the material cost by more than a third, in comparison to the single-diameter lateral, while maintaining the production rate at higher than 93%, proving its superiority. Furthermore, results indicated that exit velocities exceeding 0.8 m/sec in horizontal wells tended to distort the hydraulic head distribution near the exit, providing evidence of its inefficiency.