• 제목/요약/키워드: GFRP composite

검색결과 323건 처리시간 0.026초

복합적층 트러스 코어형 샌드위치 판구조물의 진동특성을 고려한 최적설계 (Optimum Design of the Laminated Composite Sandwich Plate Structure of Truss Core considering Vibration Characteristics)

  • 정석모;홍도관;안찬우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.703-709
    • /
    • 2001
  • In this paper, we analyzed the laminated composite sandwich plate structure of truss core with changing values of the designing parameters. As a result, in designing parameters of that, the more height and thickness of the laminated composite plate's core, the more increase of natural frequency. In this type of structure, in the case of applying core of the laminated composite plate and antisymmetric stacking, natural frequency has high value and we calculated the optimum angle-ply making natural frequency maximum. Natural frequency of CFRP is higher than that of GFRP. Both are materials of the laminated composite plate. The mode shapes are various along with the angle-ply of the laminated composite plate.

  • PDF

알루미늄/GFRP 혼성 사각튜브의 정적 압축 붕괴 및 에너지 흡수 특성 (Axial crush and energy absorption characteristics of Aluminum/GERP hybrid square tube)

  • 김구현;이정주
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.168-171
    • /
    • 1999
  • For the axial crushing tests of various shape of tubes, it was reported that composite tubes need trigger mechanism to avoid brittle failure. In this study, static axial crush tests were performed with the new aluminum/GFRP hybrid tubes. Glass/Epoxy prepregs were wrapped around aluminum tube and co-cured. The failure of hybrid tube was stable and progressive without trigger mechanism, and specific energy absorption was increased to maximum 34% in comparison with aluminum tube. Effective energy absorption is possible for inner aluminum tube because wrapped composite tube constrain the deflection of aluminum tube and reduce the folding length. The failure of hybrid composite tube was stable without trigger mechanism because inner aluminum tube could play the role of crack initiator and controller. Aluminum/Glass-Epoxy hybrid tube is suitable for the vehicle front structure due to effective energy absorption capability, easy production, and simple application for RTM process.

  • PDF

모재-섬유 함침 비율에 따른 건설용 GFRP 기둥구조의 고유진동 특성 (Natural Frequency Characteristics of GFRP Pole Structures for Civil Structures with Different Fiber-Volume Fraction)

  • 이상열
    • Composites Research
    • /
    • 제27권2호
    • /
    • pp.66-71
    • /
    • 2014
  • 본 연구는 GFRP 복합재료로 구성된 기둥 구조에 대하여 마이크로 역학 접근방법에 의한 섬유의 함침비율 변화에 따라 탄성계수를 예측하고 매크로 역학 기반으로 고유진동 특성을 분석하였다. 본 연구에서 제시하는 멀티 스케일 접근법에 의한 유한요소 모델은 해석의 정확성과 재료들 간의 상관관계를 상세하고 정확이 보여준다는 장점이 있다. 수치해석은 적층 갯수, 적층배열, 섬유함침비율의 변화에 따라서 고유진동의 변화를 분석하는데 중점을 두고 있다. 수치예제로부터 섬유와 모재의 재료비율은 거시적 동역학적 특성에 중요한 영향을 주고 있음을 알 수 있었다. 본 연구는 고유진동에 영향을 미치는 최적의 섬유와 모재 재료비율을 상세 분석하였으며, 해석 결과는 건설용으로서의 복합소재 기둥구조가 경제적이면서 우수한 동적 구조 성능을 만족하도록 설계하는데 기여할 수 있을 것으로 기대된다.

복합재 판스프링의 재료특성에 따른 스프링 강성변화와 초기 파단하중 예측 (Prediction of Spring Rate and Initial Failure Load due to Material Properties of Composite Leaf Spring)

  • 오성하;최복록
    • 대한기계학회논문집A
    • /
    • 제38권12호
    • /
    • pp.1345-1350
    • /
    • 2014
  • 본 연구에서는 자동차 판스프링을 대상으로 유리섬유 복합재의 적용을 위한 해석적 방법들을 제시하였다. 즉, 판스프링의 정적거동에 영향을 미치는 복합재 재료의 구성 성분비와 섬유각의 변화 등을 고려한 해석을 수행하였다. GFRP 복합재의 기계적 성질들은 ASTM 표준시험 방법을 따라서 직접 측정하였으며, 역해석 방법을 통해서 섬유와 수지 각각의 직교이방성과 등방성 성질들을 시험결과들로부터 재구성하였다. 다음으로 섬유의 방향과 섬유와 수지의 함유량 비와 같은 주요 재료변수들의 변화에 따른 스프링 계수들의 변화를 분석하였다. 마지막으로 초기 파괴하중을 예측하기 위해서 선형 탄성해석과 파손조건식을 이용해서 점진적 파괴해석을 수행하였으며, 그 결과 최초의 손상부위는 전단응력에 의해 판스프링의 모서리 부위에서 발생하였다.

적층수에 따른 GFRP 피막 Al 평활재의 저주기 피로수명 평가 (Low Cycle Fatigue Life Behavior of GFRP Coated Aluminum Plates According to Layup Number)

  • 명노준;서지혜;이은균;최낙삼
    • Composites Research
    • /
    • 제31권6호
    • /
    • pp.332-339
    • /
    • 2018
  • 섬유 금속 적층판(Fiber metal hybrid laminate, FML)은 금속재료와 FRP의 접합으로 기존의 금속 소재가 가지지 못했던 뛰어난 물성과 가벼운 무게로 경제적인 구조용 재료로 사용된다. 그러나 섬유의 형태와 종류, 적층조건에 따라 물성의 차이가 크며, 파괴거동을 예측하기 어렵다는 단점이 있다. 본 논문에서는 Al6061-T6 합금에 직조형태의 유리섬유 플라스틱(GFRP, GEP118)을 적층피막한 복합재의 파손거동에 대해 연구한다. Al합금에 GFRP 1, 3, 5 겹을 피막한 3가지 조건으로 성형하고, 피막의 적층수를 변수로 정적시험과 저주기 피로시험을 병행하여 파손거동을 분석하였다. 저주기 피로시험에서는 변형률-수명 해석, 전변형률 에너지밀도법을 사용하여 분석하고, 피로수명을 예측하여 하이브리드 재료에 대한 수명예측성을 분석하였다. 인장해석 결과, GFRP 피막으로 인한 강화효과는 없었고, 피로시험시 나타나는 히스테리시스 형상은 GFRP피막 유무와 피막 수에 상관없이 모재인 Al합금의 거동을 따랐다. 저주기 피로시험 결과 GFRP의 피막으로 피로강도가 증가하였지만, GFRP의 두께에 따라 비례하여 증가하지는 않았다.

비파괴시험에 의한 GFRP Pipe의 평가 (The Evaluation of GFRP Pipe by NDT Methods)

  • 이주석;조경식;장홍근;이승희
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.48-55
    • /
    • 1989
  • It is desirable to develop the effective NDT techniques to evaluate the strength of composite structures. In this study several of acoustic NDT techniques were applied to investigate useful parameters for evaluating the filament wound GFRP structures and following results were obtained. 1. Propagation velocity of stress wave to axial direction in the filament wound GFRP pipe depends on the effective modulus along the propagation direction and source location was parcticable from the a measured velocities. 2. By the application of acoustic emission techniques to GFRP pipe during hydraulic test, it was proven to be possible to detect the damage initiating pressure which could be evaluated nondestructively through the measuring of stress wave energy factor(SWEF). 3. The final failure pressure of GFRP was greatly influenced in the presence of pass through defects, and void-like defects were more dangerous than the laminar type defects.

  • PDF

GFRP를 이용한 경량중공 합성 바닥의 진동 특성에 관한 연구 (Study on the Vibration Characteristics of Light-Weight Void Composite Floor using GFRP)

  • 류재호;박세호;주영규;김상대
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2010년도 정기 학술발표대회
    • /
    • pp.35.1-35.1
    • /
    • 2010
  • 최근 고층형 주거 시설이 많이 보편화됨에 따라 층고절감과 시공의 효율성 제고 등에 대한 요구가 크게 증가하고 있다. 이에 층고를 절감하면서 동시에 장스팬을 구현할 수 있는 GFRP를 이용한 경량 중공 합성 바닥을 개발하였다. 이 바닥 시스템은 웨브에 개구부를 가지는 비대칭 철골보와 중공 경량체, 콘크리트 그리고 내력 보강 및 내화 성능 증진을 위해 비대칭 철골보 하부에 부착한 GFRP(Glass Fiber Reinforced Plastics)로 구성된다. 본 연구에서는 이 GFRP를 이용한 경량중공 합성 바닥의 진동 특성을 부재 단위 실험체를 제작하여 실험적으로 검토하였으며, 이를 통해 본 개발 합성 바닥의 고유 진동수 및 감쇠율을 측정하였다, 그 결과 기존의 이론에 근접한 진동 특성을 나타내었다.

  • PDF

Shear behaviour of RC T-beams strengthened with U-wrapped GFRP sheet

  • Panda, K.C.;Bhattacharyya, S.K.;Barai, S.V.
    • Steel and Composite Structures
    • /
    • 제12권2호
    • /
    • pp.149-166
    • /
    • 2012
  • This paper presents an experimental investigation on the performance of 2.5 m long reinforced concrete (RC) T-beams strengthened in shear using epoxy bonded glass fibre fabric. Eighteen (18) full scale, simply supported RC T-beams are tested. Nine beams are used as control beam specimens with three different stirrups spacing without glass fibre reinforced polymer (GFRP) sheet and rest nine beams are strengthened in shear with one, two, and three layers of GFRP sheet in the form of U-jacket around the web of T-beams for each type of stirrup spacing. The objective of this study is to evaluate the effectiveness, the cracking pattern and modes of failure of the GFRP strengthened RC T-beams. The test result indicates that for RC T-beams strengthened in shear with U-jacketed GFRP sheets, increase the load carrying capacity by 10-46%.

Analysis of steel-GFRP reinforced concrete circular columns

  • Shraideh, M.S.;Aboutaha, R.S.
    • Computers and Concrete
    • /
    • 제11권4호
    • /
    • pp.351-364
    • /
    • 2013
  • This paper presents results from an analytical investigation of the behavior of steel reinforced concrete circular column sections with additional Glass Fiber Reinforced Polymers (GFRP) bars. The primary application of this composite section is to relocate the plastic hinge region from the column-footing joint where repair is difficult and expensive. Mainly, the study focuses on the development of the full nominal moment-axial load (M-P) interaction diagrams for hybrid concrete sections, reinforced with steel bars as primary reinforcement, and GFRP as auxiliary control bars. A large parametric study of circular steel reinforced concrete members were undertaken using a purpose-built MATLAB(c) code. The parameters considered were amount, location, dimensions and mechanical properties of steel, GFRP and concrete. The results indicate that the plastic hinge was indeed shifted to a less critical and congested region, thus facilitating cost-effective repair. Moreover, the reinforced concrete steel-GFRP section exhibited high strength and good ductility.