• 제목/요약/키워드: GFRP패널

검색결과 13건 처리시간 0.025초

경량 GFRP 패널을 이용한 하수관거공사용 복공 가시설 시스템의 개발 (Development of Lining-Board System Using Light-Weight GFRP Panels for Sewer-Pipe Construction)

  • 박신전;홍기증
    • 복합신소재구조학회 논문집
    • /
    • 제5권3호
    • /
    • pp.23-31
    • /
    • 2014
  • Recently, sewer-pipe constructions replacing deteriorated pipes are currently underway in the downtown area. To resolve many problems in the conventional method of open-cut construction, lining-board system using light-weight GFRP panels is developed. The pultruded GFRP panels can be successfully used for the developed lining-board system as temporary decks and retaining walls in virtue of light weight, high strength and high durability. In this paper, the structural safety and serviceability of the lining-board system are examined through FE analyses and experiments. Further more, a field application of the lining-board system is presented. The field application shows that quality and environment of construction can be significantly improved.

압축과 비틂을 동시에 받는 복합스터드의 구조적 성능에 관한 연구 (A Study on the Structural Performance of Hybrid Studs Subjected to Compression and Torsion)

  • 정윤진;권영봉;곽명근;배규웅
    • 한국강구조학회 논문집
    • /
    • 제18권5호
    • /
    • pp.543-551
    • /
    • 2006
  • 최근까지 벽식 스틸하우스에 구조재로 주로 적용되어오고 있는 박판냉간성형형강 스터드의 경우 열교현상에 의한 단열상의 문제를가지고 있기 때문에 추가적인 단열재를 사용하여야 한다. 이러한 문제를 해결하기 위한 새로운 개념의 아연도금강판(t =1.0mm-1.2mm)과 난연 강화플라스틱(GFRP) 패널 (t=4.0mm-6.0mm)로 구성된 복합스터드가 개발되었다. 복합스터드 패널을 주택 에 적용하기 위하여, 복합스터드의 구조적인 거동 및 내하력 평가를 수행하였다. 본 논문에서는 ATTM(Axial/Torsional Test machine)을 이용하여 수행된 압축력과 비틂을 동시에 받는 복합스터드의 실험적인 연구결과를 기술하였다. 압축-비틂 실험의 주요 변수는 복합스터드의 길이, 초기 압축력, 가력방법 등이며, 초기 압축력을 일정하게 유지한 상태에서 스터드 시험체가 종국적인 파괴에 이르도록 비틂 하중을 점차 증가시키는 방법으로 실험을 수행하였다. 또한 고강도 아연도금강판과 GFRP의 기계적인 특성을 고려한 비선형 유한요소해석을 수행하여 실험결과와 비교, 검증하였다.

유리섬유보강 폴리머 복합패널의 피로특성 (Fatigue Properties of Glass Fiber Reinforced Polymer Composite Panels)

  • 연규석;김수보;유능환
    • 한국농공학회논문집
    • /
    • 제46권6호
    • /
    • pp.29-36
    • /
    • 2004
  • In this study, The fatigue properties of the GFRP composite panels of which core was made of the polymer mortar and both facings were reinforced by the high-tensile GFRP were surveyed. Composite-panel specimens consisted of polymer mortar core and GFRP compressive and tensile sides with various thickness were produced for an experimental study. Flexural fatigue tests were conducted to examine the correlation between the fatigue load and the fatigue life for various thickness of core and facings, and its results are presented. The correlation obtained in this study between the fatigue load and the fatigue life for various thickness arc in good agreement with the modified Miner's law.

유리섬유보강 박판패널에 의한 철근콘크리트 구조물의 보수.보강공법 (Repair and Strengthening of R/C Structure Using Glass Fiber Reinforced Plastic Thin Panels)

  • 천의균;진형장;박석암;김행준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.866-873
    • /
    • 2000
  • Reinforced concrete structure can be strengthened by glass fiber reinforced plastic thin panels. The GFRP-Thin Panels are manufactured by pressing form and their application technique are similar to steel plates. The use of FGRP-Thin Panels presents several advantages. The advantages of this structural system are the case of application, the elimination of joint and corrosion at the epoxy-panel interface. This paper introduces the method of manufacturing about GFRP-Thin Panels, mechanical properties and the application of reinforced concrete structures.

  • PDF

GFRP보강 폴리머 모르타르 샌드위치 패널의 휨 거동 (Flexural Behaviors of Sandwich Panels of Polymer Mortar Reinforced with GFRP)

  • 지경용;연규석;유근우;김남길;권윤환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.159-164
    • /
    • 2001
  • In this study, a polymer mortar sandwich panel (PMSP) was developed : Core was made with the polymer mortar whose compressive strength was about 840 kgf/$\textrm{cm}^2$, and both facings were made with the glass fiber reinforced plastics (GFRP). The results showed that the strain energies and the ductility indices increased 16-340 times and 2-8 times, respectively, as the thicknesses of facings increased from 0.6 to 3.0mm with fixing the core thickness to constants (12-36mm). On the other hand, these values showed a tendency of decrease as the core thickness increased regardless of thickness of facings. A set of basic data for the structural analysis could be provided by investigating the correlations, within the scope of this research, between the resisting moment and the thicknesses of core and facings.

  • PDF

GFRP보강 MMA개질 폴리머 모르타르 샌드위치 패널의 휨 거동 (Flexural Behavior of Sandwich Panels Using MMA Modified Polymer and GFRP)

  • 연규석;유근우;주명기;김남길;권윤환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.105-110
    • /
    • 2002
  • In this study, a MMA modified polymer mortal sandwich panels was developed : Core was made with the MMA modified polymer mortar whose compressive strength was about 1020 kgf/cm$^2$, and both facings were made with the glass fiber reinforced plastics (GFRP). The results showed that the strain energies increased 20-33 times, respectively, as the thicknesses of facings increased from 1.50 to 2.76 mm with fixing the core thickness to constants (30-50 mm). On the other hand, these values showed a tendency of decrease as the core thickness increased regardless of thickness of facings. A set of basic data for the structural analysis could be provided by investigating the correlations, within the scope of this research, between the resisting moment and the thicknesses of core and facings.

  • PDF

개량형 가동보에 적용하기 위한 패널형 유리섬유보강 폴리머 복합재료 클램핑 플레이트의 환경노출 성능 (Environmental Exposure Performance of a Panel-Type Glass-Fiber-Reinforced Polymer Composite Clamping Plate for an Improved Moveable Weir)

  • 유성열;전종찬;신형진;박찬기
    • 한국농공학회논문집
    • /
    • 제59권5호
    • /
    • pp.73-81
    • /
    • 2017
  • The improved movable weir supplements the advantages and disadvantages of the rubber weir and the conduction gate. It consists of a stainless steel gate, air bags, and a steel clamping plate. The stainless steel gate is the main body of the weir, and the inflatable rubber sheet serves to support the steel gate. The steel clamping plate is typically in direct continuous contact with water, but this leads to corrosion issues that can reduce the life of the entire movable weir. In this study, a panel-type glass-fiber-reinforced polymer (GFRP) clamping plate was designed and fabricated. The test results showed that the flexural load of the panel-type GFRP composite clamping plate was over twice that of the wings type GFRP clamping plate. The lowest moisture absorption value was obtained upon exposure to tap water, and exposure to other solutions showed similar values. Additionally, flexural load testing after exposure to an accelerated environment found the lowest residual loads of 80.51 % and 78.50 % at 50 and 100 days, respectively, for exposure to a $CaCl_2$ solution, while exposure to other environments showed residual failure loads of over 80 % at both 50 and 100 days.

투수성 GFRP 보강 복합체 개발 및 투수성에 대한 연구 (A Study on the Development and Performance Evaluation of Permeable GFRP Strengthening Panel for RC Structure)

  • 조병완;강석원;박철;김장욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.65-73
    • /
    • 2013
  • 최근 콘크리트 구조물의 보강방법으로 FRP (Fiber Reinforced Polymer)를 이용한 외부부착보강공법이 많이 활용되고 있다. FRP 외부 부착보강은 중량에 비하여 높은 강도 및 강성, 우수한 내구성과 시공성 등 여러 가지 장점을 가지는 공법이다. 그러나 외부부착보강은 구조물이 투수성이 낮은 보강재로 밀폐되고 수분이 외부로 배출되지 못함으로 인하여, 장기적인 구조물의 손상을 발생시키는 문제점이 있다. 본 연구에서는 계면의 수분을 적절하게 배출할 수 있는 GFRP 보강재를 개발하고 투수성능을 측정하는데 주목적을 두고 있다. 이를 위하여 본 연구에서는 기존에 많이 사용되고 있는 보강공법을 투수가능한 구조로 변형하고 GFRP 함량을 변수로 보강재의 투수과정을 모사하는 실내 투수시험을 수행하여 보강재의 투수계수를 측정하였다. 또한 보강재의 투수과정에 대한 수치해석을 수행하여 측정된 투수계수 값을 이론적으로 검증하고자 하였다. 그 결과 섬유 함량중 75%의 섬유 함량에서 가장 많은 0.5129 $g/h\;m^2$의 수분이 배출되었으며, 인장강도 역시 75%였을 때 최대인장강도인 4,76.6MPa를 나타내어 75% 유리섬유 함량의 COSREM GP패널이 통기성 및 구조적으로 가장 우수한 것으로 나타났다.

BFRP 보강이 직사각형 단면 철근콘크리트 기둥의 지진거동에 미치는 영향 (Effect of BFRP Wrapping on Seismic Behavior of Rectangular RC Columns)

  • 이혜린;조정현;이승건;이수형;홍기증
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.153-160
    • /
    • 2020
  • 지진동 하의 구조 시스템에서 기둥은 가장 중요한 구조 요소 중 하나이다. 이러한 관계로, 철근콘크리트(RC) 기둥의 내진 성능에 FRP 보강이 미치는 영행을 평가하기 위하여 광범위한 실험 연구가 이루어졌다. 이 중 상당수는 CFRP 또는 GFRP로 보강된 원형 단면 또는 정사각형 단면의 RC 기둥의 지진 거동에 집중하였다. 단면의 형태가 FRP 보강으로 인한 구속 효과에 영향을 미치기 때문에, 보강 효과와 최종 파괴 패턴이 형상에 따라 상이할 수 있다. 본 연구에서는 현무암 섬유를 함유한 BFRP 시트와 복합섬유 패널로 보강한 직사각형 단면을 가진 RC 기둥의 지진 거동을 살펴보기 위하여 반복하중 실험을 수행하였다. 실험 결과는 보강 효과가 크지 않았음을 보여주는데, BFRP 시트와 복합섬유 패널에 의한 구속 효과의 증가가 미미했음을 의미하며, 이는 기둥 단면 형상에 일부 기인하는 것으로 판단된다.