• 제목/요약/키워드: GFRP(Glass Fiber Reinforced Plastic)

검색결과 125건 처리시간 0.024초

Bonding Performance of Glulam Reinforced with Textile Type of Glass- and Aramid-Fiber, GFRP and CFRP

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권2호
    • /
    • pp.156-162
    • /
    • 2011
  • To evaluate the bonding performance of reinforced glulam, the textile type of glass fiber and aramid fiber, and the sheet type of glass fiber reinforced plastic (GFRP) and carbon fiber reinforced plastic (CFRP) were used as reinforcements. The reinforced glulam was manufactured by inserting reinforcement between the outmost and middle lamination of 5ply glulam. The types of adhesives used in this study were polyvinyl acetate resins (MPU500H, and MPU600H), polyurethane resin and resorcinol resin. The block shear strengths of the textile type in glass fiber reinforced glulam using MPU500H and resorcinol resin were higher than 7.1 N/$mm^2$, and these glulams passed the wood failure requirement of Korean standards (KS). In case of the sheet types, GFRP reinforced glulams using MPU500H, polyurethane resin and resorcinol resin, and CFRP reinforced glulams using MPU500H and polyurethane resin passed the requirement of KS. The textile type of glass fiber reinforced glulam using resorcinol resin after water and boiling water soaking passed the delamination requirement of KS. The only GFRP reinforced glulam using MPU500H after water soaking passed the delamination requirement of KS. We conclude that the bonding properties of adhesive according to reinforcements are one of the prime factors to determine the bonding performance of the reinforced glulam.

Analysis of steel-GFRP reinforced concrete circular columns

  • Shraideh, M.S.;Aboutaha, R.S.
    • Computers and Concrete
    • /
    • 제11권4호
    • /
    • pp.351-364
    • /
    • 2013
  • This paper presents results from an analytical investigation of the behavior of steel reinforced concrete circular column sections with additional Glass Fiber Reinforced Polymers (GFRP) bars. The primary application of this composite section is to relocate the plastic hinge region from the column-footing joint where repair is difficult and expensive. Mainly, the study focuses on the development of the full nominal moment-axial load (M-P) interaction diagrams for hybrid concrete sections, reinforced with steel bars as primary reinforcement, and GFRP as auxiliary control bars. A large parametric study of circular steel reinforced concrete members were undertaken using a purpose-built MATLAB(c) code. The parameters considered were amount, location, dimensions and mechanical properties of steel, GFRP and concrete. The results indicate that the plastic hinge was indeed shifted to a less critical and congested region, thus facilitating cost-effective repair. Moreover, the reinforced concrete steel-GFRP section exhibited high strength and good ductility.

유리섬유 강화 플라스틱과 알루미늄 합금 접합을 위한 유한요소해석 (Finite element analysis for joining glass fiber reinforced plastic and aluminium alloy sheets)

  • 조해용;김동범
    • Journal of Welding and Joining
    • /
    • 제33권2호
    • /
    • pp.78-84
    • /
    • 2015
  • Self-piercing rivet(SPR) is mechanical joining methods and which can be joining dissimilar materials. Unlike conventional riveting, SPR also needs no pre-drilled holes. During plastically deformation, SPR pierces upper sheet and joins it to under sheet. SPR has been mainly applied to the joining the automobile body and some materials, such as glass fiber reinforced polymer and aluminum alloy, which represent the sheet-formed materials for lightweight automobile. Glass fiber reinforced plastic(GFRP) has been considered as a partial application of the automobile body which is lighter than steels and stronger than aluminium alloys. It is needed SPR to join Al alloy sheets and GFRP ones. In this paper, in order to design the rivet and anvil, which are suitable for GFRP, the joinability was examined through simulations of SPR joining between GFRP and Al alloy sheets. For this study, AutoCAD was used for the modeling and the simulated using commercial FEM code DEFORM-2D. The simulated results for SPR process joining between GFRP and Al alloys were confirmed by the same conditions as experimental trials.

의장적 기둥의 설계를 위한 유리섬유강화플라스틱과 철의 접합부 강도의 실험적 연구 (Experimental Study of Glass Fiber Reinforced Plastic-Steel Connection for Decorative Column)

  • 황경주;최취경
    • 한국공간구조학회논문집
    • /
    • 제13권4호
    • /
    • pp.41-47
    • /
    • 2013
  • For the artistic column used by Glass Fiber Reinforced Plastic(GFRP), the connection of steel with GFRP were needed. Due to the fabricating characteristics of hand laminating, GFRP surfaces had to be connected. Because there were no existed data of these connection, experimental study has to be followed so that the structural strength and buckling mode could be investigated. In this paper, therefore, the axial tests of steel with GFRP were performed. The connection of GFRP's surfaces could be also tested as well. As a result, it could be figured out that the strength of these connections were determined by the adhesive strength.

충격속도에 따른 GFRP 및 AFRP의 충격흡수에너지 거동

  • 김철웅;송삼홍;오동준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.74-74
    • /
    • 2004
  • 탄소섬유강화 적층재(Carbon Fiber Reinforced Plastic, 이하 CFRP)는 강성도는 뛰어나지만 충격특성에는 취약한 단점이 있다. 따라서 충격저항과 충격에너지 흡수율이 상대적으로 우수한 유리섬유강화 적층재(Glass Fiber Reinforced Plastic, GFRP) 및 아라미드섬유강화 적층재(Aramid Fbier Reinforced Plastic, 이하 AFRP)를 CFRP 적용분야에 대체하고 점차적으로 피로특성을 개선시켜 나간다면 특성이 더욱 개선된 제품을 사용할 수 있을 것으로 판단된다.(중략)

  • PDF

SENT시험편을 이용한 CFRP/GFRP 하이브리드 적층재의 노치선단부 변형률 평가 (The Strain Evaluation of the Notch tip Area for the CFRP/GFRP Hybrid Laminate Plate using the SENT Specimen)

  • 강지웅
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.15-21
    • /
    • 2014
  • The aim of this work is conduct the study on light weight and structural performance improvement of the composite wind power blade. GFRP (Glass Fiber Reinforced Plastic) pre-empted by CFRP(Carbon Fiber Reinforced Plastic), the major material of wind power blade, was identified the superiority of mechanical performance through the tensile and fatigue test. SENT(Single Edge Notched Tension) specimen fracture test was conducted on the specimen that laminated together 2 ply CFRP with 4 ply GFRP through DIC(Digital Image Correlation) analysis. The SENT specimen thickness and $a_0/W$ ratio is 1.45 mm and 0.2, respectively. The fracture test accomplished with displacement control with 0.1 mm/min at the room temperature. The experimental apparatus used for the fracture test consisted of a 50kN universal dynamic tester and CCD camera connected to a personal computer (PC), which was used to record images of the specimen surface. Following data acquisition, the images and load-displacements were transferred to the PC, on which the DIC software was implement. The experiment and DIC analysis results show that CFRP/GFRP laminated composite exhibits improvement of the strength, compared with that of the existing blade material. This study shows the result that the strength of CFRP rotor blade of wind turbine satisfies through the experimental and DIC method.

유리섬유보강 박판패널에 의한 철근콘크리트 구조물의 보수.보강공법 (Repair and Strengthening of R/C Structure Using Glass Fiber Reinforced Plastic Thin Panels)

  • 천의균;진형장;박석암;김행준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.866-873
    • /
    • 2000
  • Reinforced concrete structure can be strengthened by glass fiber reinforced plastic thin panels. The GFRP-Thin Panels are manufactured by pressing form and their application technique are similar to steel plates. The use of FGRP-Thin Panels presents several advantages. The advantages of this structural system are the case of application, the elimination of joint and corrosion at the epoxy-panel interface. This paper introduces the method of manufacturing about GFRP-Thin Panels, mechanical properties and the application of reinforced concrete structures.

  • PDF

FRP로 보강된 RC보의 전단보강효과 비교연구 (A Comparative Study on the Shear-Strengthening Effect of RC Beams Strengthened by FRP)

  • 심종성;김규선
    • 콘크리트학회지
    • /
    • 제10권4호
    • /
    • pp.101-111
    • /
    • 1998
  • 본 논문의 목적은 전단내력이 부족한 R/C보에 CFS(Carbon Fiber Sheets), CFRP(Carbon Fiber Reinforced Plastic), GFRP(Glass Fiber Reinforced Plastics)를 이용해 전단보강을 할 경우에 보의 역학적 거동특성을 규명하기 위한 것이다. 본 논문의 목적을 달성하기 위하여 총 19개의 시험체가 제작되었으며, 실험변수로는 전단스팬비, 보강재료, 보강방법, 보강간격 및 방향을 산정하였다. 본 논문의 실험결과, FRP를 이용해 전단내력이 부족한 R/C보에 보강을 하였을 경우 약 50~70%정도의 보강효과를 나타내었다. 또한 소성이론에 근거한 철근콘크리트보의 전단강도 예측모델을 개발하였고 실험치와의 비교를 통해 개발된 모델의 적합성을 검증하였다.

GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 접합부의 모멘트저항 성능평가 (Moment Resistance Performance Evaluation of Larch Glulam Joints using GFRP-reinforced Laminated Plate and GFRP Rod)

  • 정홍주;송요진;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.40-47
    • /
    • 2016
  • 구조용 집성재 라멘 접합부에 일반적으로 사용되는 접합철물을 대신하여 단판과 GFRP (Glass Fiber Reinforced Plastic)를 복합시킨 GFRP 보강적층판과 삽입 접착형 GFRP rod를 접합물로 사용하였다. 이들을 적용시킨 접합부에 대한 모멘트저항 성능평가 결과, 접합철물을 이용한 실험체(Type-1)와 비교하여 GFRP 보강적층판과 GFRP rod 핀을 사용한 실험체의 항복모멘트는 4% 낮게 측정되었으나 회전강성은 29% 높게 측정되었다. 또한 GFRP 보강적층판과 목재(Eucalyptus marginata)핀을 사용한 실험체는 Type-1 실험체와 비교하여 항복모멘트 11%, 회전강성 56% 높게 측정되며 가장 양호한 성능을 나타냈었다. 파괴형상과 완전탄소성 분석을 통해서도 핀에 의한 전단내력으로부터의 취성파괴가 아닌 연성거동을 나타내며, 접합내력이 상승하고 부재의 일체화가 이루어짐을 확인하였다. 반면, GFRP rod를 삽입 접착한 실험체는 접착 불량으로 측정이 불가하거나 접합성능이 매우 낮게 측정되었다.

국부 열손상을 받은 복합재료의 탄성파특성 (Characteristics of Elastics Waves of Fiber-Reinforced Plastic with Localized Heat Damage)

  • 남기우;김영운
    • 한국해양공학회지
    • /
    • 제16권4호
    • /
    • pp.48-53
    • /
    • 2002
  • Fiber-reinforced composites are extensively used in electronic, ship and aerospace applications due to their high strength and high toughess. In these applications, they are often subjected to localized heat damage due to various sources. In order to ensure their reliability, it is important to predict their residual properties using nondestructive evaluation thchniques. Fabric fiber composite specimens were manufactured with six layers of the glass-fiber prepreg and the carbon-fiber prepreg, respectively. The specimens were subjected to a localized heat damage using a heated copper tip with a diameter of 10mm at 35$0^{\circ}C$(CFRP) and 30$0^{\circ}C$(GFRP), respectively. The specimens were then subjected to tension tests while acoustic emission (AE) activities of specimens were collected. The AE activity of all specimens showed three types of distinct frequency regions. Those are matrix cracking, failure of the fiber/matrix interface and fiber breakage.