• Title/Summary/Keyword: GC-MS (gas chromatographic-mass spectrometry)

Search Result 34, Processing Time 0.043 seconds

GC-MS and GC-FID Analysis of Citronella Oil Products for Indicator Ingredient Identification

  • Sumin Kang;Wooil Kim;Jin Wuk Lee;Sangwon Cha
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.160-165
    • /
    • 2023
  • Citronella oil, an essential oil extracted through steam distillation from the leaves and stems of Cymbopogon, is a natural complex substance (NCS) regulated by the Korean government for its use in insect repellents. The component ratios of NCSs like citronella oil vary due to differences in manufacturing processes and origins, presenting a challenge in identifying and quantifying these substances in consumer chemical products. This study analysed ten commercially available products of the most commonly used types of citronella oil, specifically Java and Ceylon types, using gas chromatography (GC)-mass spectrometry (MS) and GC with flame ionization detection (FID). Through chromatographic data, we aimed to determine the components that can qualitatively identify citronella oil and the indicator ingredients that can be used for content analysis.

Electrospray Ionization Mass Spectrometric Observation of Oligomers in Paal-Knorr Synthesis of 2,5-Dimethyl-1-phenylpyrrole

  • Park, So-Young;Chun, Man-Seog;Song, Jin-Su;Kim, Hie-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.575-578
    • /
    • 2005
  • Electrospray ionization mass spectrometry (ESI MS) was used, along with gas chromatography-mass spectrometry (GC-MS), to monitor Paal-Knorr synthesis of 2,5-dimethyl-1-phenylpyrrole by condensation of aniline with 2,5-hexanedione. In addition to 2,5-dimethyl-1-phenylpyrrole observed as a single spot by TLC, unexpected dimer size compounds were observed by GC-MS. Dimers and trimers were observed by ESI MS. ESI tandem mass spectrometry was used to select plausible structures for the dimer. ESI MS with or without liquid chromatographic separation is useful for observing oligomeric byproducts with low volatility produced in organic reactions.

Quality Assessment of Curcuma longa L. by Gas Chromatography-Mass Spectrometry Fingerprint, Principle Components Analysis and Hierarchical Clustering Analysis

  • Li, Ming;Zhou, Xin;Zhao, Yang;Wang, Dao-Ping;Hu, Xiao-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2287-2293
    • /
    • 2009
  • Gas Chromatography-Mass Spectrometry (GC-MS) fingerprint analysis, Principle Components Analysis (PCA), and Hierarchical Cluster Analysis (HCA) were introduced for quality assessment of Curcuma longa L. (C. longa). The GC-MS fingerprint method was developed and validated by analyzing 33 batches of samples of C. longa from different geographic locations. 18 chromatographic peaks were selected as characteristic peaks and their relative peak areas (RPA) were calculated for quantitative expression. Two principal components (PCs) were extracted by PCA. C. longa collected from Guizhou and Fujian were separated from other samples by PC1, capturing 71.83% of variance. While, PC2 contributed for their further separation, capturing 11.13% of variance. HCA confirmed the result of PCA analysis. Therefore, GC-MS fingerprint study with chemometric techniques provides a very flexible and reliable method for quality assessment of C. longa.

Simultaneous Determination of Valproic Acid and its Toxic Metabolites, 4-ene-VPA and 2,4-diene-VPA in Rat Plasma using a Gas Chromatographic-mass Spectrometric Method

  • Lee, Min-Sun;Lee, Young-Joo;Chung, Bong-Chul;Jung, Byung-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.3
    • /
    • pp.155-160
    • /
    • 2010
  • A gas chromatographic-mass spectrometric (GC-MS) method was developed for the simultaneous determination of valproic acid (VPA) and its toxic metabolites, 4-ene-VPA and 2,4-diene-VPA in rat plasma. Extraction was performed in weak acidic condition (pH 5.2) to avoid degradation of 4-ene-VPA and 2,4-diene-VPA. The recoveries for 4-ene-VPA and 2,4-diene-VPA were more than 70% and that for VPA was 33-42%. R value for each compounds exceeded 0.998 in calibration curve during all the analysis. Accuracy and precision ranged from 88.3 to 113.2% and from 2.16 to 14.2%, respectively The method was successfully applied to monitor plasma concentrations of VPA, 4-ene-VPA and 2,4-diene-VPA after intravenous administration of VPA at the dose of 100 mg/kg, suggesting that these toxic metabolites may involved in the hepatotoxicity induced by VPA.

Analysis of $\beta$-Blockers in Whole Blood by GC/MS-SIM

  • Rhee, Jong-Sook;Yang, Hee-Jin;Seol, Il-Ung;Koo, Ki-Ser
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.219.3-219.3
    • /
    • 2003
  • We describe here solid-extraction and derivatisation methods of ${\beta}$-adrenoceptor blocking drugs used for the treatment of various cardiovascular disorders such as hypertension, angina pectoris and cardiac arrhythmia: propranolol, metoprolol, sotalol, timolol, oxprenolol, alpranolol, atenolol, pindolol. Solid-extraction and derivatisation methods are described involving the use of Bond Elut Certify cartridges, MSTFA and MBTFA. Gas chromatographic-mass spectrometry analysis(GC/MS) was carried out select-ion monitroing mode. (omitted)

  • PDF

Determination of bisphenol-A using GC/MS in Can Materials (기체크로마토그래피/질량분석법을 이용한 캔 물질에서의 bisphenol-A 분석)

  • Kim, Ki-Cheol;Kim, Yang-Hee;Choi, Ok-Kyung;Ko, Hoan-Uck;Yim, Jun-Rae;Choi, Kyo-Hong;Cho, Hyun-Woo;Kim, Hye-Young;Kim, Myungsoo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.499-503
    • /
    • 2001
  • A new simple, rapid and sensitive gas chromatographic technique for the determination of bisphenol-A in can materials, which is the major material of epoxy resin and polycarbonate polymer, is proposed. This method is characterised by derivatization of the bisphenol-A with a acylating reagent forming the acetate derivative to optimize the chromatographic property. The detection of bisphenol-A is performed based on GC/MS (gas chromatography/mass spectrometry). Several beverages were analyzed by the proposed method for the determination of bisphenol-A Bisphenol-A was assayed the range of $0.11{\sim}11.40{\mu}g/can$ from the can materials.

  • PDF

Determination of MTBE, TBA and BTEX in Soil by Headspace Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1693-1698
    • /
    • 2012
  • A headspace gas chromatographic mass spectrometric (GC-MS) assay method was developed for the simultaneous determination of methyl tertiary butyl ether (MTBE), $tert$-butyl alcohol (TBA) and benzene, toluene, ethyl benzene and xylene (BTEX) in soil contaminated with gasoline. 2 g of soil sample were placed in a 10 mL headspace vial filled with 5 mL of phosphoric acid solution (pH 3) saturated with NaCl, and the solution was spiked with fluorobenzene as an internal standard and sealed with a cap. The vial was heated in a heating block for 40 min at $80^{\circ}C$. The detection limits of the assay were 0.08-0.12 ${\mu}g$/kg for the analytes. For five independent determinations at 10 and 50 ${\mu}g$/kg, the relative standard deviations were less than 10%. The method was used to analyze fifty six soil samples collected from various regions contaminated with gasoline in Korea. The developed method may be valuable for the monitoring of the analytes in soil.

Determination of Icing Inhibitors (Ethylene Glycol Monomethyl Ether and Diethylene Glycol Monomethyl Ether) in Ground Water by Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang;Jung, Dong-Gyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.806-808
    • /
    • 2004
  • A gas chromatography/mass spectrometric assay method has been developed for the simultaneous determination of icing inhibitors, ethylene glycol monomethyl ether and diethylene glycol monomethyl ether in ground water contaminated with JP-8. Ethylene glycol monobutyl ether and ethylene glycol monoethyl ether were used as the internal standard and surrogate, respectively. 100 mL of ground water was extracted twice with 20 mL of methylene chloride. The extract was concentrated to dryness, dissolved with 100 ${\mu}$L of methanol and analyzed by GC-MS (SIM). The use of an Innowax column gave the peaks good chromatographic properties, and the extraction of these compounds from samples gave recoveries of about 50% with small variations. The method detection limits of the target compounds were in a range of 0.5-0.8 ng/mL in ground water.

Determination of total iodide in seawater by gas chromatography-mass spectrometry (Gas chromatography-mass spectrometry를 이용한 해수 중 총 요오드 정량분석)

  • Shin, Ueon-Sang
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.445-450
    • /
    • 2002
  • A sensitive gas chromatographic method has been established for the determination of total iodide in seawater as their volatile organic derivative. The method is based on the formation of 4-iodo-2,6-dimethylphenol with 2,6-dimethylphenol in matrix and a single-step extraction of the derivative with ethyl ether, which are then measured by gas chromatography-mass spectrometry (selected ion monitoring). Iodate in sea water was completely reduced to iodide with ascorbic acid and acetic acid. The detection limit was 0.1 ng/mL in seawater and the calibration curve showed good linearity with r=0.9997. The method was sensitive, reproducible and simple enough to permit the reliable routine analysis of total iodide in seawater. Total iodide in sea water was found about 30 ng/ml.

A Rapid Method for Analysing Polycyclic Aromatic Hydrocarbons (PAH's) in Urban Dust Using Supercritical Fluid Extraction (SFE) and Gas Chromatography/Mass Spectrometry (GC/MS)허귀석, 김달호 (초임계유체추출과 GC/MS를 이용한 도심 대기분진 중 PAH들의 신속한 분석법에 관한 연구)

  • Heo, Gwi Seok;Kim, Dal Ho
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.726-733
    • /
    • 1994
  • Supercritical fluid extraction (SFE) followed by gas chromatographic separation and mass spectrometric (MS) detection were used in rapid analysis of polycyclic aromatic hydrocarbons (PAH's) in air particulate material extracted for 30 min with 10 ml of supercritical $N_2O$ without another sample preparation step. Two samples, urban dust in Seoul area and a certified air particulate reference material 1649 supplied by the NBS (National Bureau of Standards), were processed for the purpose of evaluating extraction and analysis methods. As a result, the quantitative recovery of PAH's in the SFE method was relatively lower than conventional organic solvent extraction methods, but reproducibility was resonable, and analysis time was reduced remarkably. The method has proved to be suitable for monitoring of PAH's in air particulate material.

  • PDF