• 제목/요약/키워드: GAs analysis

검색결과 9,140건 처리시간 0.031초

가스 터빈 Hot gas casing에 대한 유동 및 열응력 해석 (A study on the flow and thermal analysis of the hot gas casing of gas turbine)

  • 최영진;이영신;김재훈;박원식;김현수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.557-561
    • /
    • 2004
  • The hot gas casing of gas turbine has operated high temperature and thermal gradient. The structure safety of hot gas casing will be highly depend on the thermal stress. In this paper, flow and thermal stress analysis of hot gas casing is carried out using ANSYS program. The obtained temperature data by flow analysis of hot gas casing apply the load condition of the thermal analysis. The thermal stress analysis is carry out the elastic-plasticity analysis. The pressure, temperature and velocity of the flow and thermal stress of the hot gas casing are presented.

  • PDF

인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석 (Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage)

  • 최연석;이인환
    • 한국기계가공학회지
    • /
    • 제18권5호
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.

DEA 기법을 활용한 안전관리자의 운영 효율성 평가 (A Study on the Efficiency Analysis for the Operations of the Safety Patrol applying the DEA Approach)

  • 유우연;장서일;강경식;이동훈;이경식;조영도
    • 대한안전경영과학회지
    • /
    • 제9권5호
    • /
    • pp.17-25
    • /
    • 2007
  • All of the city gas companies in Korea must employ the gas safety patrols by law. The gas safety patrols are responsible for the various tasks including daily gas pipeline patrol to prevent gas accidents. Since the size of jurisdiction varies among the city gas companies, it is very difficult to compare their efficiency for the operations of the safety patrol each other directly. The objective of this research is to develop the methodology to analyze and compare the efficiency of the safety patrol's operations among various city gas companies. Several factors that are related to the safety patrol's duty on the gas safety factors were identified and DEA(Data Envelopment Analysis) model for efficiency analysis was developed. Finally, the DEA model was applied to the collected data from six city gas companies. The less efficient city gas companies can benchmark the higher efficient city gas companies in order to improve the safety control systems.

Rotordynamic Analysis for Stepped-Labyrinth Gas Seals Using Moodys Friction-Factor Model

  • Ha, Tae-Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권9호
    • /
    • pp.1217-1225
    • /
    • 2001
  • The governing equations are derived for the analysis of a stepped labyrinth gas seal generally used in high performance compressors, gas turbines, and steam turbines. The bulk-flow is assumed for a single cavity control volume set up in a stepped labyrinth cavity and the flow is assumed to be completely turbulent in the circumferential direction. The Moodys wall-friction-factor model is used for the calculation of wall shear stresses in the single cavity control volume. For the reaction force developed by the stepped labyrinth gas seal, linearized zeroth-order and first-order perturbation equations are developed for small motion about a centered position. Integration of the resultant first-order pressure distribution along and around the seal defines the rotordynamic coefficients of the stepped labyrinth gas seal. The resulting leakage and rotordynamic characteristics of the stepped labyrinth gas seal are presented and compared with Scharrers theoretical analysis using Blasius wall-friction-factor model. The present analysis shows a good qualitative agreement of leakage characteristics with Scharrers analysis, but underpredicts by about 20%. For the rotordynamic coefficients, the present analysis generally yields smaller predictied values compared with Scharrers analysis.

  • PDF

Study on Decomposition Gas Characteristics and Condition Diagnosis for Gas-Insulated Transformer by Chemical Analysis

  • Kim, Ah-Reum;Kwak, Byeong Sub;Jun, Tae-Hyun;Park, Hyun-Joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.447-454
    • /
    • 2020
  • Since SF6 gas was discovered in the early 1900s, it has been widely used as an insulation material for electrical equipment. While various indicators have been developed to diagnose oil-immersed transformers, there are still insufficient indicators for the diagnosis of gas-insulated transformers. When necessary, chemical diagnostic methods can be used for gas-insulated transformers. However, the field suitability and accuracy of those methods for transformer diagnosis have not been verified. In addition, since various types of decomposition gases are generated therein, it is also necessary to establish appropriate analysis methods to cover the variety of gases. In this study, a gas-insulated transformer was diagnosed through the analysis of decomposition gases. Reliability assessments of both simple analysis methods suitable for on-site tests and precise analysis methods for laboratory level tests were performed. Using these methods, a gas analysis was performed for the internal decomposition gases of a 154 kV transformer in operation. In addition, simulated discharge and thermal fault experiments were demonstrated. Each major decomposition gas generation characteristics was identified. The results showed that an approximate diagnosis of the inside of a gas-insulated transformer is possible by analyzing SO2, SOF2, and CO using simple analysis methods on-site. In addition, since there are differences in the types of decomposition gas generation patterns with various solid materials of the internal transformer, a detailed examination should be performed by using precise analysis methods in the laboratory.

에너지시설(도시가스배관)의 사고시 영향 평가 (Consequence Analysis of Energy Facility(City Gas Pipeline))

  • 박교식;이진한;조영도;박진희
    • 한국가스학회지
    • /
    • 제7권1호
    • /
    • pp.10-18
    • /
    • 2003
  • 도시가스시설에서 사고가 발생할 때 그 영향을 평가하는 방법론에 대하여 현실을 고려한 모델을 개발하였다. 즉 사건수목분석(ETA)을 통하여 발생할 수 있는 사고의 형태를 도출하였고 가스의 누출 속도를 음속인 경우와 아음속인 경우에 대하여 계산하였다. 가스의 누출시 화재가 주로 피해를 유발하므로 화재가 발생하여 사망, 화상 및 건물에 피해를 줄 수 있는 경우 그 피해범위를 산정하는 방법을 제시하였다. 마지막으로 적절한 가정을 도입하여 사고로 인한 총 손실비용을 계산하는 방법을 제시하였다.

  • PDF

국내 수소사고사례 분석 (Analysis of Hydrogen Accident in Korea)

  • 조영도;탁송수;최경석;이종락;박교식
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.82-87
    • /
    • 2004
  • Hydrogen is considered to be the most important future energy carrier in many applications reducing greenhouse gas emissions significantly. To be applicable as energy carrier the safety issues associated with hydrogen applications needs to be investigated and fully understood. In order to analyze the risks associated with hydrogen applications, accidents associated with hydrogen in Korea from 1963 to 2002 have been analysed in this work. From analysis of accidents, we propose the necessity of research on hydrogen releases, dispersion in air, and explosion due to high hazardous of hydrogen.

도시가스 배관의 설비손상확률평가 (Frequence Analysis for City Gas Pipeline)

  • 박교식;이진한;조영도;박진희
    • 한국가스학회지
    • /
    • 제7권2호
    • /
    • pp.14-21
    • /
    • 2003
  • 도시가스 배관에서 위험을 유발할 수 있는 사건의 발생빈도를 구하기 위하여 주요 사고원인인 굴착공사, 외부부식, 지반침하 및 장치손상 등에 의한 사고발생빈도를 구하는 방법을 제시하였다. 굴착공사로 인한 손상은 FTA에 의해 기본사상(Basic event)을 도출하고, 부식에 의한 손상확률은 시간변화에 따른 부식결함의 잔존강도를 평가하는 평가식을 제시하였다. 지반침하로 인한 손상은 기준손상율을 구하고 여기에 손상모드인자 및 보정인자를 고려한 모델을 이용하여 구하였다. 장치원인에 의한 손상확률은 고유고장율과 특정고장율 자료를 모두 반영할 수 있는 방법을 제시하였으며 그 계산 예도 제시하였다.

  • PDF

드레인-소스 전극 간극의 변화에 따른 Gas Sensor의 열에너지 확산 해석 (Heat Energy Diffusion Analysis in the Gas Sensor Body with the Variation of Drain-Source Electrode Distance)

  • 장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.589-595
    • /
    • 2017
  • MOS-FET structured gas sensors were manufactured using MWCNTs for application as NOx gas sensors. As the gas sensors need to be heated to facilitate desorption of the gas molecules, heat dispersion plays a key role in boosting the degree of uniformity of molecular desorption. We report the desorption of gas molecules from the sensor at $150^{\circ}C$ for different sensor electrode gaps (30, 60, and $90{\mu}m$). The COMSOL analysis program was used to verify the process of heat dispersion. For heat analysis, structure of FET gas sensor modeling was proceeded. In addition, a property value of the material was used for two-dimensional modeling. To ascertain the degree of heat dispersion by FEM, the governing equations were presented as partial differential equations. The heat analysis revealed that although a large electrode gap is advantageous for effective gas adsorption, consideration of the heat dispersion gradient indicated that the optimal electrode gap for the sensor is $60{\mu}m$.

Application of Advanced Impact Analysis in Developing Iran's Gas Industry Scenarios

  • Servati, Yasser;Ghodsypour, Seyed Hassan;Soleimani, Mansooreh
    • Industrial Engineering and Management Systems
    • /
    • 제15권4호
    • /
    • pp.307-317
    • /
    • 2016
  • According to most of energy sector experts, at least in the next two decades, fossil energy plays important role in fulfilling required energy in the world. Based on these conditions, the investigation of the conditions of major countries providing natural gas in the world can be useful in analysis of future development of this clean fuel. According to the latest estimations of British Petroleum Company, Iran with 18.2% natural gas reservoirs has the first natural gas reservoirs in the world. The main purpose of this paper is developing scenarios of gas industry in Iran. To achieve the mentioned goals, besides investigation of existing methods of scenario design and existing production scenarios, natural gas export and consumption in Iran and the world in 2035, the most important scenarios of gas industry in Iran are formulated by critical uncertainty analysis approach using quantitative advanced time based impact analysis in 2035 horizon.