• 제목/요약/키워드: GAS Leakage

검색결과 723건 처리시간 0.024초

Optimum Design of a Non-Destructive Testing System to Maximize Magnetic Flux Leakage

  • Park, G.S;Jang, P.W;Rho, Y.W
    • Journal of Magnetics
    • /
    • 제6권1호
    • /
    • pp.31-35
    • /
    • 2001
  • This paper describes the design method of a magnetic system to maximize the magnetic flux leakage (MFL) in a non-destructive testing (NDT) system. The defect signals in a MFL type NDT system mainly depend on the change of the magnetic leakage flux in the region of a defect. The characteristics of the B-H curves are analysed and a design method to define the operating point on B-H curves for maximum leakage is performed. The computed MFL signal by a nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG, the traveling detector unit in gas pipe, in an 8 inch test tube with defects. The rhombic defects could be successfully identified from the defect signals.

  • PDF

지하주차장 내 수소연료 자동차의 수소 누설로 인한 수소 확산에 대한 수치해석 연구 (A NUMERICAL SIMULATION OF HYDROGEN DIFFUSION FOR THE HYDROGEN LEAKAGE FROM FCV IN UNDERGROUND PARKING LOT)

  • 최종락;허남건;이은덕;이광범
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.477-482
    • /
    • 2011
  • In the present study, the diffusion process of hydrogen leaking from a FCV (Fuel Cell Vehicle) in an underground parking lot was analyzed by numerical simulations in order to assess the risk of a leakage accident. The temporal and spatial changes of the hydrogen concentration as well as the flammable region in the parking lot were predicted numerically. The effects of the leakage flow rate and an additional ventilation fan were investigated to evaluate the ventilation performance in the parking lot to relieve the accumulation of the leaked hydrogen gas. The present numerical analysis can provide useful information such as the distribution of the leaked hydrogen concentration for safety of various hydrogen applications.

  • PDF

건축물내 일산화탄소 경보기 설치에 관한 연구 (A Study on Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석;오정석
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2008년도 춘계학술 발표회
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

가정용 연료전지 시스템 내부 수소 누출 시 센서 응답 특성에 관한 연구 (A experimental study on the sensor response at hydrogen leakage in a residential fuel cell system)

  • 김영두;신동훈;정태용;남진현;김영규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2009-2014
    • /
    • 2007
  • Hydrogen is a fuel of fuel cell system, which has powerful explosion possibility. Hence, the fuel cell system needs safety evaluation to prevent risk of hydrogen leakage. We use a actual size chamber of a common fuel cell module to analyze hydrogen. Hydrogen injection holes are located in lower part of the chamber in order to simulated hydrogen leakage. The hydrogen sensor can detect range of 0${\sim}$4%. Since the hydrogen gas, of which leaked amount is controled by MFC, are injected at the bottom holes, the transient sensor signals are measured. At a condition of 10cc/s of hydrogen leakage, the sensor detects hydrogen leakage after 22sec and there is also several seconds of time delay depending on the position of the sensor. This experimental data can be applied for the design of the hydrogen detection system and ventilation system of a residential fuel cell system.

  • PDF

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

수소충전소의 안전성 평가 연구 (A Study on Safety Assessment of Hydrogen Station)

  • 표돈영;김양화;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.499-504
    • /
    • 2019
  • Due to the rapid spread and low minimum ignition energy of hydrogen, rupture is highly likely to cause fire, explosion and major accidents. The self-ignition of high-pressure hydrogen is highly likely to ignite immediately when it leaks from an open space, resulting in jet fire. Results of the diffusion and leakage simulation show that jet effect occurs from the leakage source to a certain distance. And at the end of location, the vapor cloud explosion can be occurred due to the formation of hydrogen vapor clouds by built-up. In the result, it is important that depending on the time of ignition, a jet fire or a vapor cloud explosion may occur. Therefore, it is necessary to take into account jet effect by location of leakage source and establish a damage minimizing plan for the possible jet fire or vapor cloud explosion. And it is required to any kind of measurements such as an interlock system to prevent hydrogen leakage or minimize the amount of leakage when detecting leakage of gas.

동적 위험 분석을 위한 사고확률 추정 방법에 관한 연구 (Estimation of Accident Probability for Dynamic Risk Assessment)

  • 박병철;임채옥;남인혁;신성철
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.315-325
    • /
    • 2023
  • Recently, various dynamic risk analysis methods have been suggested for estimating the risk index by predicting the possibility of accidents and damage. It is necessary to maintain and support the safety system for responding to accidents by continuously updating the probability of accidents and the results of accidents, which are quantitative standards of ship risk. In this study, when a LNG leakage that may occur in the LN G Fuel Gas Supply System (FGSS) room during LN G bunkering operation, a reliability physical model was prepared by the change in monitoring data as physical parameters to estimate the accident probability. The scenario in which LNG leakage occur were configured with FT (Fault Tree), and the coefficient of the covariate model and Weibull distribution was estimated based on the monitoring data. The possibility of an LNG leakage, which is the top event of FT, was confirmed by changes in time and monitoring data. A method for estimating the LNG leakage based on the reliability physical analysis is proposed, which supports fast decision-making by identifying the potential LNG leakage at the accident.

화학물질 누출에 따른 긴급 확산 방재시스템 개선 방안 연구 (A Study on the Improvement of Emergency Block and Diffusion Prevention System for Hazardous Chemicals Leakage)

  • 이덕재;윤정현;유병태
    • 한국가스학회지
    • /
    • 제22권5호
    • /
    • pp.89-99
    • /
    • 2018
  • 화학물질을 취급하는 중 소업체의 경우 누출 사고 시 자동화 시스템이 갖춰진 안전장치에 의한 방재체계가 아닌 근로자에 의한 긴급 방재가 주로 이루어져 인명 환경피해 등의 발생 가능성이 높다. 본 연구는 이러한 한계점을 개선하기 위해 화학물질 취급공정 중 누출 사고 발생 빈도에 따라 누출 예상지점에 선별적으로 쉽게 탈 부착이 가능한 긴급 확산방재시스템에 대해 연구하였다. 이를 통해 사고대응이 상대적으로 취약한 중소기업의 화학사고를 시스템적으로 예방하여 화학물질 누출사고에 의한 인명, 환경피해를 방지할 수 있다.

Test Results of the Mechanical Face Seal for a Turbopump

  • Kwak, Hyun-D.;Jeon, Seong-Min;Kim, Jin-Han
    • KSTLE International Journal
    • /
    • 제8권1호
    • /
    • pp.11-15
    • /
    • 2007
  • The mechanical face seal has been tested in Korea Aerospace Research Institute (KARl) for turbopump applications. In the turbopump under current development, the mechanical face seal is installed between fuel pump and turbine to prevent a mixture of fuel and combustion gas. Generally the mechanical face seal in turbopump is exposed to severe environment because of great rotational speed, high temperature of combustion gas and high level of pressure difference. Thus a series of tests were performed to guarantee the reliability of mechanical face seal by means of simulating the practical operating conditions. The tests were conducted up to 20,000 rpm with pressure difference of 800 kPa and temperature of 620 K In addition several carbon materials for mechanical face seal were conducted to the tests to compare the life time. During the tests, the performance against leakage was monitored and the carbon wear was also measured to estimate the life of a mechanical face seal The results show that the leakage flow rates of mechanical face seal is ignorable compared to an overall flow rate of fuel pump. The carbon material which has the finest wear resistance was found during the tests. Lastly no critical failure of mechanical face seal was found during the tests and the reliability of mechanical face seal for turbopump was successfully proved.

자동차 연료호스, 인젝터 및 압력조절기 연결부에서 LP 가스 누출에 의한 화재사례 고찰 (Study for Fire Examples of LPG Leakage Including Fuel hose, Injector and Pressure Regulator Connector in Vehicle)

  • 이일권;국창호;서문원;정동화
    • 한국가스학회지
    • /
    • 제17권3호
    • /
    • pp.8-13
    • /
    • 2013
  • 이 논문의 목적은 LPG 자동차에서 연료누설에 의한 화재관련 사례에 대하여 연구하는 것이다. 첫 번째 사례는, 엔진의 연료 레귤레이터 및 인젝터 사이의 고압호스와 연결되는 연료 라인을 수리한 다음 고정하는 볼트를 규정토크로 조이지 않아 호스가 빠지면서 LP 가스가 누출되어 엔진의 열에 의해 화재가 발생한 것을 확인하였다. 두 번째 사례는, 인젝터를 교환한 다음 흡기매니폴드 유닛의 조립부에 삽입할 때 고정하는 고정부를 점검하지 않고 고정부가 변형되어 휜 상태에서 조립한 결과 연료의 누설을 방지하는 O링이 찢어져 이 사이로 연료가 누출된 것으로 확인되었다. 세 번째 사례는, 연료압력 조절기 유닛에는 연료 차단 솔레노이드 밸브가 연결되어 있는데 수리 후 이 연결 커넥터의 기밀작업을 철저하게 하지 않아서 미세하게 LP 가스가 누설되다가 어느 순간에 많은 양의 가스가 누설되면서 엔진의 열에 의해 화재가 발생된 것을 확인하였다. 따라서, 연료 시스템에 문제가 없는지 철저하게 관리하여 화재의 발생이 최소가 되도록 하여야 한다.