• Title/Summary/Keyword: GAS Boiler

Search Result 362, Processing Time 0.031 seconds

Establishing the Models for Optimized Design of Water Injection in Boilers with Waste-heat-recovery System (가습연소 폐열회수 보일러의 물분사 설계모델 구축에 관한 연구)

  • Shin, Jaehun;Moon, Seoksu
    • Journal of ILASS-Korea
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2021
  • In order to improve the overall efficiency and meet the emission regulations of boiler systems, the heat exchanging methods between inlet air and exhaust gas have been used in boiler systems, named as the waste-heat-recovery condensing boiler. Recently, to further improve the overall efficiency and to reduce the NOx emission simultaneously, the concept of the water injection into the inlet air is introduced. This study suggests the models for the optimized design parameters of water injection for waste-heat-recovery condensing boilers and performs the analysis regarding the water injection amount and droplet sizes for the optimized water injection. At first, the required amount of the water injection was estimated based on the 1st law of thermodynamics under the assumption of complete evaporation of the injected water. The result showed that the higher the inlet air and exhaust gas temperature into the heat exchanger, the larger the amount of injected water is needed. Then two droplet evaporation models were proposed to analyze the required droplet size of water injection for full evaporation of injected water: one is the evaporation model of droplet in the inlet air and the other is that on the wall of heat exchanger. Based on the results of two models, the maximum allowable droplet sizes of water injection were estimated in various boiler operating conditions with respect to the residence time of the inlet air in the heat exchanger.

Heat Flow Analysis of Inner Groove Tube for Latent Heat Exchanger in Condensing Gas Boiler (콘덴싱 가스보일러 잠열교환기의 이너 그루브 튜브 열유동 해석)

  • Yong, Kyeong-Jung;Lim, Byung-Chul;Park, Sang-Heup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4052-4056
    • /
    • 2014
  • These days, household condensing gas boilers are an obligatory trend. The use of environmentally-friendly boilers that emit less pollutant, such as CO and NOx, are strongly recommended. In this paper, heat flow analysis of the additional inner groove in the tube of the secondary latent heat exchanger was studied to increase the efficiency. A 20% difference in the heat transfer area was obtained with the addition of an inner grove, which showed an increase in the amount of heat transferred. This was confirmed using three-dimensional numerical analysis. With the addition of an inner groove, the exit temperature increased by $1^{\circ}C$. This increase in exit temperature was considered to be a substantial increase in the efficiency of the condensing gas boiler.

A Study on the Effect of Recirculated Exhaust Gas upon Exhaust Emissions of Boiler with a FGR System (FGR 시스템 보일러의 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Jung, Kwang-Ho;Cho, Yong-Soo;Bae, Myung-Whan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.405-415
    • /
    • 2007
  • The effects of recirculated exhaust gas on exhaust emissions under four kinds of nozzle tip with the different fuel consumption rates are experimentally investigated by using an once-through boiler with a FGR system. The purpose of this study is to develop the FGR control system for reducing $NO_x$ emissions in boilers. Intake and exhaust oxygen concentrations, and equivalence ratio are considered to figure out the effect of FGR rate on exhaust emissions at various fuel consumption rates. It is found that $NO_x$ emissions are markedly decreased, while soot emissions are increased owing to the drop of intake and exhaust oxygen concentrations, and the rise of equivalence ratio as FGR rates are elevated. One can also conclude that the reduction in $NO_x$ emissions is more considerably influenced by the variation of equivalence ratio due to the FGR rate than the fuel consumption rate.

Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler (자트로파 유(Crude Jatropha Oil)에 대한 보일러 직접 연소 특성)

  • Kang, Sae-Byul;Kim, Jong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2934-2939
    • /
    • 2008
  • We conducted a test of a direct burning of crude Jatropha oil (CJO) in a commercial boiler system. The fuel, crude Jatropha oil is not biodiesel which comes from transeterification process of bio oil, but it is pure plant oil. The higher heating value (HHV) of the CJO is 39.3 MJ/kg (9,380 kcal/kg) and is higher than that of a commercial heating oil, 37.9 MJ/kg. The kinematic viscosity of CJO is 36.2 mm2/s at $40^{\circ}C$ and 8.0 mm2/s at $100^{\circ}C$. The burner used in the test is a commercial burner for a commercial heatingoil and its capacity is 140 kW (120,000 kcal/h). We did a preliminary test whether the combustion is stable or not. The preliminary test was a kind of open air combustion test using the commercial burner with crude Jatropha oil. We found that the combustion can be stable if the crude Jatrophaoil temperature is higher than $90^{\circ}C$. We measured the flue gas concentration by using a gas analyzer. The NOx concentration is $80{\sim}100\;ppm$ and CO concentration is nearly 0 ppm at flue gas O2 concentration of 3.0 and 4.5%.

  • PDF

The Experimental Study on the Heat Transfer Characteristics (가스보일러 코일형 열교환기의 열전달 특성에 관한 실험적 연구)

  • Hong, S.H.;Kim, Y.K.;Kim, I.G.;Kim, D.C.;Lee, C.E.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • The performance of gas-fired boilers were experimentally investigated. The heat exchanger used for the experiments consisted of circular tube with longitudinal fins for the gas side and a spiral coil for the water side. The burner was located at the top of the heat exchanger, and the burned gas flowed down to the exit. The experiments carried out for different water flow rates, the heat capacities of the boiler and the number of baffle. The thermal efficiency of the upward flow was higher than that of the downward flow of the water in the heat exchanger. As the boiler capacity increased, the thermal efficiency decreased. As the number of the baffles increase, the thermal efficiency increased and the increasing rate of the efficiency decreased. The gas-side overall heat transfer coefficient was independent of the flow rate of the water. The effect of the number of the baffles on the heat transfer coefficient was greater than that of the boiler capacity.

  • PDF

Combustion Characteristics of Heavy Fuel Oil-water Emulsion

  • Kim Houng-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.88-92
    • /
    • 2006
  • This study is intended to check the flame temperature to raise in burning grade C heavy fuel oil and emulsion fuel oil in a boiler and to measure the concentration of Dry Shoot(DS) and Soluble Organic Fraction(SOF) after collecting the Particulate Matters (PM). The flames temperature in boiler was measured by burning grade C heavy oil and oil-water emulsion (C heavy oil $70\%\;and\;30\%$ of water) Combustion characteristics of two fuels was also compared by trapping particulate matters (PM) in exhaust gas and measuring the generated quantities of DS and SOF in fuel gas.

A Study on Desulfurization and Denitrification of Flue Gas in Industry Boiler (산업용 보일러의 배연탈황 및 탈질에 관한 연구)

  • 이태호;정순형;정흥기
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.99-104
    • /
    • 1995
  • The objective of this study was to investigate the effect on denuclearization and decertification of flue gas by utilizing Mg( OH)$_{2}$ and NaOH as reagents in industrial boiler. We used packed absorber with Tellerette in all cases. And pH of circulation solution, rate of liquid per gas in absorber, COD concentration by pH variation in oxidation basin were inves- tigated. The following conclusions were obtained from experimental results: 1. Concerning running cost for reagents, Mg( OH)$_{2}$ reagent for treatment of flue gas was more economical than NaOH. 2. While Mg( OH )$_{2}$ and NaOH as absorbents were used, then the ratio of denuclearization was 96 and 97% respectively and nitrification was recorded 29 and 25% . 3. In this absorption tests the optimum condition for ratio of liquid per gas, pH and nonregenerable salt concentration of circulation solution were 3.6ℓ /Nm$^{3}$, 6.0, 0.5∼1.0% respectively, 4. Initial COD in oxidation basin was 800 ∼ 1,00099ut after adjusting to pH 7.0, COD of effluent water was less than 20ppm.

  • PDF

A Thermodynamic Study on Exhaust Heated Gas Turbine Cycle (연소기 후치 가스터빈에 관한 열역학적 연구)

  • Park, J.K.;Ohu, S.C.;Yang, O.Y.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.18-28
    • /
    • 1994
  • An exhaust-heated gas turbine cycle equipped with a waste heat recovery boiler and ammonia absorption-type refrigerator using waste heat is newly devised and analyzed. The general performance of this cycle is compared with that of the conventional gas turbine cycle. This cycle shows a potential high efficiency. When 1500K of gas turbine inlet temperature the efficiency is 53 percent as compared to 45 percent for a conventional combined cycle. Suction cooling of this cycle leads to improve the thermal efficiency and the specific output.

  • PDF

A Study on Design Characteristics of Yeosu Circulating Fluidized Bed Boiler (여수화력 순환유동상 보일러의 설계특성 고찰)

  • Kim, Jae-Sung;Lee, Jong-Min;Kim, Dong-Won;Kim, Tae-Hyun;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • 340 MWe circulating fluidized bed (CFB) boiler in Yeosu power station is under construction. The circulating fluidized bed boiler in the Yeosu power plant has a number of differences from other domestic boilers in terms of scale and design. Evaluation of design parameters of the Yeosu CFB boiler should be required because the direct application of existing technology is limited. In this study, design characteristics of the Yeosu CFB boiler was summarized. And thermogravimetric analysis was conducted with comparing other rank coals. Watersteam side heat absorption, flue gas temperature and heat transfer coefficient were calculated by heat and mass balance. Design parameters for the Yeosu CFB boiler were discussed along with typical value in the CFB design range.