• Title/Summary/Keyword: GAS Boiler

Search Result 362, Processing Time 0.026 seconds

An Experimental Study on the Load Delivery Characteristics of Hybrid Energy System with Geothermal and Solar Heat Sources (지열-태양열원 복합시스템의 부하추종특성에 관한 실험 연구)

  • Hwang, In-Ju;Woo, Nam-Sub
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.2 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of the present study is to investigate the load delivery characteristics of a hybrid-renewable energy system with geothermal and solar heat sources for hot water, heating and cooling of a residential house in Korea. The hybrid energy system consists of ground source heat pump of 2 RT for cooling with a 150 m vertical U-bend ground heat exchanger, solar collectors of 4.8 m2 and gas fired backup boiler. The averaged coefficient of performance of geothermal module during cooling and heating seasons are evaluated as about 4.5 and 3.8, respectively.

  • PDF

Development of Waste Plastics-Based RDF and Its Combustion Properties

  • Park, Woo-Zin;Chung, Young-Hee
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.765-769
    • /
    • 2001
  • The refuse-derived fuel(RDF) is manufactured using waste plastics-based materials and its physical and chemical properties are analyzed. The manufacturing process consists of hand picking, primary magnetic separation, crushing, secondary magnetic separation, feeding and extrusion. The RDF products have a higher calorie content of over 6, 000 ㎉/kg and high stability because the waste plastics and paper are mainly selected. The combustion flue gas of RDF products is satisfied with the emission criteria of incinerator. The heavy metal concentration of combustion byproduct from the RDF boiler is also satisfied with the criteria and appears to be lower concentration than that of a common municipal waste incinerator.

  • PDF

Flow Characteristic Analysis in Accordance with Geometrical Modification of Air Distribution Plate in Gasboiler Combustion Chamber (가스보일러 연소실 공기분배판의 기하학적 형상에 따른 유동특성 해석)

  • Kim, Jae-Jung;Son, Young-Gap;Chang, Seog-Weon;Ryu, Dong-Su
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.859-864
    • /
    • 2000
  • This paper reports a numerical flow characteristic analysis in gas boiler combustion chamber. The numerical results with simplification and assumptions were found within 30% of the experiment. A lot of geometrical modification has been invested in attempt to obtain the uniform flow in the combustion chamber exit. As a result, the velocity magnitude of the combustion chamber is relate with the hole size in air distribution plate. The velocity uniformity of the combustion chamber is relate with the number of holes and location in air distribution plate.

  • PDF

Complex Process Control using the Adaptive Neural Fuzzy Inference System

  • Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.351-351
    • /
    • 2000
  • Since the heat exchange system, such as the boiler of power plant, gas turbine, and radiator require an application of intelligent control system for a high rate heat efficiency and the efficiency of these systems is depended on the control methods it is important for operator to understand control system of these systems and intelligent control technologies. In order to properly apply control equipment and intelligent technology to these process control systems, it is necessary to understand fuzzy, neural network, genetics, and immune as well as the basic aspects and operation principle of the process that relate control, interrelationships of the process characteristics, and the dynamics that are involved. Generally, since PID controllers are used in these systems it is difficult far engineer to understand both the complex dynamics and the intelligent control method. In this paper, we design an effective experimental system for the intelligent control education and analyze its characteristics through experimental system and each intelligent method to study how they can learn intelligent control system by experiments.

  • PDF

Development of Preheating Module for Domestic Heating Facility, Using PCM(Phase Change Material) Thermal Storage Equipment (상변화물질(PCM)을 이용한 가정용 보일러의 잠열축열식 예열모듈 개발)

  • Son, Chul-Min;Kim, Tae-Wook;Na, Kyu-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.3
    • /
    • pp.163-169
    • /
    • 2009
  • A preheating module for domestic heating facility will increase a energy efficiency. That collects the wasted heat of exhaust gas and saves the energy. So a heating load is decreased because of a preheating that has a heating energy. Using of a preheating module, a boiler can reduce frequent operation of a burner. So it is increased persistence, decreased discharging noxious gases. Therefore we will intend to develop a heating facility that is a convenient system for the saving energy.

  • PDF

Development of Fuzzy Logic Controller for Automatic Combustion of Refuse Incinerator (쓰레기 소각로 자동 연소를 위한 퍼지 제어기의 개발)

  • Song, Young-Seuk;Park, Jang-Geon;Kim, Yong-Tae;Lee, He-Young;Zeungnam Bien
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1996.10a
    • /
    • pp.123-128
    • /
    • 1996
  • In this paper, a fuzzy controller is proposed for the operation of stoker-type refuse incinerator with many kinds of uncertain factors. To build the exact mathematical model is very difficult because of the variation of physical/chemical properties of refuse as a fuel and the complexity of the combusiton process. The fuzzy controller consists of fuzzy sensor, fuzzy decision maker and tracking part. The rules based on the professional operators empirical knowledge are made for the control of the boiler evaporation rate, emission gas and refuse throughput. For the performance measure of the proposed fuzzy controller, the model of the incinerator is constructed and the simulation results are given.

  • PDF

A Study on the maintenance situation of the deteriorted high-rise apartments (노후 고츨아파트의 유지관리 및 개선실태 조사)

  • 주서령;이미정
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.75-83
    • /
    • 2001
  • The deteriorted high-rise apartments make a social problem in now days. As a result, and new alternative plan for deteriorted high-rise apartments such as the remodeling concept must be considered. This study aims to develop the remodeling items which is the guide lines when remodeling of the apartment will be conducted. Thorough the case studies of maintenance and repair status of the deteriorted apartments in seoul, reasonable guidelines for selection of remodeling items were developed. Physical maintenance items includes those that need major repair activity like wall painting, water proof roof, change/repairs/implement of heating system, boiler, city gas pipelines, cold and hot water pipes, elevators, cleaning of water tanks. The period of repair is shorter than the durable year of law or codes. As a result of the study, basic maintenance items and actual repair period were proposed. This result will be the basic guidelines for remodeling items.

  • PDF

A Study on the Discharge Characteristics and the Collection Efficiency of the Electrostatic Precipitator for Pulverized Coal Boiler (미분탄 연소 보일러용 전기집진기의 방전특성 및 집진특성에 관한 연구)

  • Lee, Tae-Sik;Son, Jin-Woon;Nam, Chang-Woo;Lee, Kyu-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.10
    • /
    • pp.570-576
    • /
    • 2000
  • The discharge and the collection efficiency characteristics of an electrostatic precipitator have been studied under various operating conditions. The specific resistivity of pulverized coal dust was about 1013∼1014[${\Omega}{\cdot}cm$] and reached the maximum value of 6${\times}$1013[${\Omega}{\cdot}cm$] at 150[$^{\circ}C$]. Back corona has been occurred as dust contents and gas temperature increase. In the case of back corona occurrence, collection effciency decreased rapidly. This problem has been solved by increasing moisture contents. Experimental results showed that collection efficiency of the full wave voltage was higher than that of the pulse wave voltage. The modification parameter k of the collection efficiency equation was about 0.42.

  • PDF

Evaluation of self-heating propensity and its relation with fuel properties of various coals (다양한 탄종별 자체발열 특성과 물성의 비교 분석)

  • Kim, Jungsoo;Lee, Yongwoon;Im, Hyeon Soo;Park, Hoyoung;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.83-85
    • /
    • 2013
  • With an increase in the use of low rank coals in power plants, various operational issues were raised in the fuel storage and supply, combustion, boiler and flue gas treatment systems. In the fuel storage and supply system, the main issue is the self-heating propensity of low rank coals leading to spontaneous combustion in yard storage, transport and pulverization. This study evaluated the reactivity of various sub-bituminous and bituminous coals with oxygen at low temperatures by analyzing the temperature increase characteristics of coals under a constant flow rate of oxygen supply. The results were quantified to a self-heating index and the relation with the fuel properties were evaluated.

  • PDF

Processes of Outflow of the Boiling Steam-Water Mixture in the Widening Part of Hydro-Steam Turbine Nozzles

  • Leonid, Serejkin;Boris, Shifrin;Victor, Perov;Alexandr, Goldin
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.12
    • /
    • pp.178-184
    • /
    • 2022
  • Renewable energy sources based on solar radiation, wind energy, geothermal energy, and biomass energy have now reached the level of industrial application. A new way to generate electricity using low-potential heat is to install a hydro-steam turbine. In hydro-steam turbines, hot water is supplied directly to turbine rotor nozzles without prior separation into steam and water in separators, which significantly increases the efficiency of hot water energy use. Such turbines are suggested to be used as autonomous energy sources in geothermal heating systems, heating water boilers and cooling systems of chemical reactors, metallurgical furnaces, etc. The authors conclude that the installation of hydro-steam turbines in heating plants and process boiler plants can also be effective if the used exhaust steam-water mixture at the turbine outlet is used to heat the network water or as return water.