• Title/Summary/Keyword: GAIT PATTERN

Search Result 295, Processing Time 0.022 seconds

A Position based Kinematic Method for the Analysis of Human Gait

  • Choi Ahn Ryul;Rim Yong Hoon;Kim Youn Soo;Mun Joung Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1919-1931
    • /
    • 2005
  • Human joint motion can be kinematically described in three planes, typically the frontal, sagittal, and transverse, and related to experimentally measured data. The selection of reference systems is a prerequisite for accurate kinematic analysis and resulting development of the equations of motion. Moreover, the development of analysis techniques for the minimization of errors, due to skin movement or body deformation, during experiments involving human locomotion is a critically important step, without which accurate results in this type of experiment are an impossibility. The traditional kinematic analysis method is the Angular-based method (ABM), which utilizes the Euler angle or the Bryant angle. However, this analysis method tends to increase cumulative errors due to skin movement. Therefore, the objective of this study was to propose a new kinematic analysis method, Position-based method (PBM), which directly applies position displacement data to represent locomotion. The PBM presented here was designed to minimize cumulative errors via considerations of angle changes and translational motion between markers occurring due to skin movements. In order to verify the efficacy and accuracy of the developed PBM, the mean value of joint dislocation at the knee during one gait cycle and the pattern of three dimensional translation motion of the tibiofemoral joint at the knee, in both flexion and extension, were accessed via ABM and via new method, PBM, with a Local Reference system (LRS) and Segmental Reference system (SRS), and then the data were compared between the two techniques. Our results indicate that the proposed PBM resulted in improved accuracy in terms of motion analysis, as compared to ABM, with the LRS and SRS.

Effects of Forefoot Rocker Shoes with Metatarsal Bar on Lower Extremity Muscle Activity and Plantar Pressure Distribution (중족골 바 형태의 전족부 라커 신발이 하지 근 활성도 및 족저압력 분포에 미치는 영향)

  • Park, In-Sik;Jung, Ji-Yong;Jeon, Keun-Hwan;Won, Yong-Gwan;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.113-121
    • /
    • 2012
  • The purpose of this study was to evaluate the effects of forefoot rocker shoes equipped with a metatarsal bar on lower extremity muscle activity and plantar pressure distribution. Ten healthy women in the age of twenties were participated in this study as the subjects. All subjects walked on a treadmill(Gait Trainer, BIODEX, USA) wearing normal shoes and metatarsal bar shoes, during which the plantar pressure distribution and muscle activity were measured. Using Pedar-X system(Novel Gmbh, Germany), the plantar pressure was measured for six regions of the foot: forefoot, midfoot, rearfoot, 1st metatarsal, 2-3th metatarsal, and 4-5th metatarsal, and for each sub-region, 4 features such as maximum force, contact area, peak pressure, and mean pressure were analyzed based on the plantar pressure. EMG(Electromyography) activity was measured by attaching surface electrodes to the rectus femoris, biceps femoris, tibialis anterior, and gastrocnemius medial head, and magnitude of muscle contraction was analyzed in IEMG(Integrated EMG) value. The results show that the maximum force, contact area, peak pressure, and mean pressure in the midfoot all increased while maximum force, peak pressure, contact area, mean pressure in the 1st metatarsal and 2-3th metatarsal all decreased when wearing functional shoes. Also, muscle activities in the four muscles were all decreased when wearing the functional shoes. This paper suggests that forfoot rocker shoes equipped with a metatarsal bar can help disperse the high pressure and absorb the shock to the foot as well as give positive influence on gait pattern and postural stability by reducing muscle fatigue during walking.

A Steerable Quadruped Walking Robotic System with Legs of a Closed-Chain Mechanism (폐쇄 기구형 다리의 조향가능 4족 보행 로봇 시스템)

  • Im, Seung-Cheol;Jeong, Hae-Seong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.118-123
    • /
    • 2000
  • Most quadruped walking robots under current research are individually controlling every joint ic make them step or walk according to an integrated strategy. Such methods are characterized by at least one pair of an actuator and a sensor installed per each 'oint so that the robots weigh execssively and move inefficiently in terms of energy expenditure. In addition, the task of controlling all the joints simultaneously is quite complex and prone to destabilize the robot motion. These respects keep the existing walking robots away from realistic applications such as transportation even if they have potentially, outstanding adaptability to swamps or uneven terrains as opposed to wheeled vehicles. So, this paper presents a new conceptual quadruped robot developed to walk and steer only with a minimal number of actuators owing to a closed-chain mechanism. To prove its actual performance including the adaptability to various types of terrains. experiments are done with the mammal-type prototype. And. it is also shown that the same concept can be easily extended to carry out different gait forms. for instance, that of spiders only with minor modifications.

Developing an Biomechanical Functional Performance Index for Parkinson's Disease Patients (한국형 파킨슨 환자의 역학적 기능수행지수 개발)

  • Shin, Sunghoon;Han, Byungin;Chung, Chulmin;Lee, Yungon
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.83-91
    • /
    • 2020
  • Objective: The study aimed to develop a functional performance index that evaluates the functional performance of Parkinson's patients, i.e., to integrate biomechanical measurements of walking, balance, muscle strength and tremor, and to use multiple linear regression with stepwise methods to identify the most suitable predictors for the progression of disease. Method: A total of 60 subjects were tested for sub-variables of four factors: walking, balance, isometric strength and hand tremors. Potential independet variables were extracted through correlation analysis of the sub-variables and dependent variables, Hoehn & Yahr scale. And then, a stepwise multiple regression analysis using the potential independent variables was performed to identify predictor of Hoehn & Yahr scale. Results: First, the results of the study showed that physical composition and gait had a relatively more correlated with the progression of the disease, compared to balance and hand tremor. Second, Parkinson's functional performance is characterized by dynamic pattern of walking, such as foot clearance and turning angle (TA) of walking, and a high-explained regression model is completed. Conclusion: The study emphasized the importance of walking variables and body composition in minor pathological features compared to Parkinson's patient's balancing ability and hand tremor. Specifically, it revealed that dynamic walking patterns functionally characterize patients. The results are worth considering when assessing functional performance related to the progression of the disease at the site.

A Study on the Distribution of Plantar Pressure in Adult Hemiplegia during Gait with the Use of Cane

  • Cha, Yong-Jun;Kim, Kyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.3
    • /
    • pp.49-53
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the plantar pressure distribution between the affected and unaffected side in adult hemiplegia during gait with the use of a quad-cane. Methods: Thirty-four stroke patients from 34 to 83 years of age were enrolled in this study, and in random order, all patients were asked to walk at their most comfortable speed three times along a walkway with the use of quad-cane over a period of three days. Plantar pressure distribution was measured with regard to foot contact pattern and center of pressure (CoP) trajectories during the stance phase, progressing from heel-strike to toe-off. The F-scan system was used to compare the foot pressure of the affected and unaffected sides. Results: A significant reduction in the total contact area, the width of fore foot (FF) and hind foot (HF), and anterior/posterior (AP) CoP trajectory of the affected side was found. However, contact pressure of the hind foot on the affected side during walking increased when compared to that on the unaffected side. Conclusion: We demonstrated that plantar pressure distribution on the affected side of adult hemiplegia patients was generally poorer than that on the unaffected side when these patients walked with cane assistance. However, the use of a quad-cane was shown to increase contact pressure of the hind foot on the affected side because weight can be borne on the affected side during heel-strike with use of the cane.

Estimation of Tibia Angle through Time-Varying Complementary Filtering and Gait Phase Detection (시변 상보필터와 보행상태 추정을 이용한 경골의 기울어짐 각도추정)

  • Song, Seok-ki;Woo, Hanseung;Kong, Kyoungchul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.10
    • /
    • pp.944-950
    • /
    • 2015
  • Recent studies on ankle-foot prostheses used for transtibial amputees have focused on the adaptation of the ankle angle of the prosthesis according to ground conditions. For adaptation to various ground conditions (e.g., incline, decline, and step conditions), ankle-foot prostheses should first recognize the ground conditions as well as the current human motion pattern. For this purpose, the ground reaction forces and orientation angle of the tibia provide fundamental information. The measurement of the orientation angle, however, creates a challenge in practice. Although various sensors, such as accelerometers and gyroscopes, can be utilized to measure the orientation angles of the prosthesis, none of these sensors can be solely used due to their intrinsic drawbacks. In this paper, a time-varying complementary filtering (TVCF) method is proposed to incorporate the measurements from an accelerometer and a gyroscope to obtain a precise orientation angle. The cut-off frequency of TVCF is adaptively determined according to the human gait phase detected by a fuzzy logic algorithm. The performance of the proposed method is verified through experiments.

Dynamic Gait embody using angular acceleration for a Walking Robot (각가속도를 이용한 이족 로봇의 동적 걸음새 구현)

  • Park, Jae-Mun;Park, Seung-Yub;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.209-216
    • /
    • 2007
  • In this paper, we embodied posture-stabilization and dynamic gait in a walking robot. 10 RC servo motors are used to operate joints. And the joints have enough moving ranges suitable in any walking pattern. Each joint trajectory is generated by cubic spline interpolation method and the stability of the trajectory is verified by using Zero Moment Point from the robot modeling. To avoid complex structure and expression, Zero Moment Point of the biped robot used angular acceleration is suggested. To measure the stability of the biped robot, Tilt sensor and gyro sensor are used. Finally, Personal Computer is used computer monitoring and data processing. Most of computation, such as 10 RC servo motor control, joint trajectory generating, ZMP compensation, sense measuring, etc, was used Digital Signal Processor.

  • PDF

A Case Study of Functional Electrical Stimulation(FES) for Paraplegic Patients (척수손상인의 기능적 전기자극을 이용한 보행)

  • Lee, Jae-Ho;Kim, Tack-Hoon
    • Physical Therapy Korea
    • /
    • v.3 no.3
    • /
    • pp.32-43
    • /
    • 1996
  • The purpose of this case study was to introduce functional electrical stimulation(FES) for paraplegic patients. FES provides the ability to rise from sitting to standing, maintenance of a standing position, and the ability to walk with a reciprocal gait. Six channels of electrical stimulation are sufficient for synthesis of a simple reciprocal gait pattern in these patients. During the double-stance phase, knee extensor muscles of both knees are stimulated, providing sufficient support for the body. Only one knee extensor muscle group is excited during the single-stance phase. The swing phase of the contralateral lower extremity is accomplished by eliciting the synergic flexor muscle response through electrical stimulation of afferent nerves. The transition from the double-stance phase to the swing phase is controlled by two hand switches used by the therapist or built into the handles of the walking frame for using by the patient. A twenty-five years old male was with a T9/T9 spinal cord injury due to a traffic accident and admitted to Yonsei Rehabilitation Hospital for comprehensive treatment. After 30 days of training using the Parastep(R) he was able to stand for 10 minutes. After 43 days, he was able to walk and at discharged he could walk for 100 meters.

  • PDF

Floor Slipperiness Effect on the Biomechanical Study of Slips and Falls

  • Myung, Ro-Hae;Smith, James L.;Lee, Soon-Yo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.22 no.3
    • /
    • pp.337-349
    • /
    • 1996
  • A study was conducted to find the possible relationship between slip distance and dynamic coefficient of friction (DCOF) through the biomechanical study of slips and falls using a broader variety of floors and levels of slipperiness than those used before. Four different floor surfaces covering the full range of floor slipperiness (with and without on oil contaminant) were prepared for ten subjects with each walking at a fixed velocity. The results showed that slip distance and heel velocity had a decreasing trend while stride length had a increasing trend as DCOF increased. The contaminant effect overpowered floor slipperiness effect because a higher DCOF surface with oil contaminant created longer slip distance than the lower DCOF with dry floor. Normal gait pattern and suggested heel velocity (10 to 20 cm/sec) were seen on dry floors but abnormally longer stride length and 5 to 10 times faster heel velocity were found an oily floors. In other words, faster heel velocity (greater than 10 to 20 cm/sec) is recommended to measure DCOF on oily floors because the assumption of normal gait was no longer valid.

  • PDF

Gait Implementation of Biped Robot for a continuous human-like walking (이족 보행 로봇의 인간과 유사한 지속보행을 위한 걸음새 구현)

  • Jin, Kwang-Ho;Jang, Chung-Ryoul;Koo, Ja-Hyuk;Choi, Sang-Ho;Kim, Jin-Geol
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3092-3094
    • /
    • 1999
  • This paper deals with the gait generation of Biped Walking Robot (IWR-III) to have a continuous walking pattern like human. For this, trajectory planning with the consideration of kick action is done in each walking step, and the coordinate transformation is done for simplifying the kinematics. The trunk moves continuously for all walking time and moves toward Z-axis. Balancing motion is acquired by FDM(Finite Difference Method) during the walking. By combining 4-types of pre-defined steps, multi-step walking is done. Using numerical simulator, dynamic analysis and system stability is confirmed. Walking motion is visualized by 3D-Graphic simulator. As a result, the motion of balancing joints can be reduced by the trunk ahead effect during kick action, and impactless smooth walking is implemented by the experiment.

  • PDF