• Title/Summary/Keyword: GAC

Search Result 298, Processing Time 0.025 seconds

The global regulator GacS of a biological bacterium Pseudomonas chlororaphis O6 regulates expression of the stationary-phase sigma factor rpoS and reduces survival in oxidative stress.

  • Kang, Beom-Ryong;Cho, Baik-Ho;Kim, Young-Cheol
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.100.2-101
    • /
    • 2003
  • The global regulator, GacS (global antibiotic and cyanide sensor kinase), was required for the increased resistance to hydrogen peroxide occurring as cultures of the rhizobacterium, P. chlororaphis O6, matured. Specific stationary-phase peroxidase and catalase isozymes were absent in the GacS mutant, whereas a manganese-superoxide dismutase isozyme was expressed earlier and to a great extent than wild type. In the wild type cell, transcript accumulation of rpoS was higher in late logarithmic-phase cells than cells from mid logarithmic- or stationary-phase. Transcripts from rpoS in the GacS mutant were reduced in each of these growth phases compared to the wild type expression. The down stream sequence from rpoS lacked sequences encoding a small RNA, rsmZ, found in other pseudomonads and implicated in control of genes activated by the GacS system. These findings suggest that GacS-mediated regulation of RpoS plays role in control of oxidative stress in P. chlororaphis O6 by as yet an unknown mechanism.

  • PDF

Treatment of Melamine by GAC Adsorption According to Adsorbent Size: Kinetics and Dispersion-Diffusion (흡착제 크기에 따른 GAC의 멜라민 흡착 처리 : 반응속도와 분산-확산)

  • Lee, Jai-Yeop;Lee, Sangjung;Han, Ihnsup
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.65-72
    • /
    • 2013
  • Adsorption of melamine was examined using columns packed with granular activated carbon (GAC). Raw GAC was sieved with 20, 40, 60 and 80 mesh to determine the influence of adsorbent particle size on reaction and diffusion. The mass ratio of the adsorption capacity of GAC for melamine ranged from 9.19 to 11.06%, and adsorption rates increased with decreasing particle size within this range. Rate constants between 3.295 ~ 4.799 $min^{-1}$ were obtained using a pseudofirst-order equation that was used to determine adsorption kinetics. A surface diffusion model was adapted to take into account the unsteady-state equation of a spherical adsorbent by converting the surface concentration from a constant to a variable governed by a dispersion equation. The calculated values were fit with the experimental results by using the diffusion coefficients as regression parameters. The modified equation exhibited a more precise agreement with respect to the sum of the absolute error (SAE).

Decision of Backwashing frequency and method on the GAC adsorber (입상활성탄 흡착지 운영에서 역세척 주기와 팽창률의 영향 평가)

  • Chae, Seon-Ha;Cho, Chang-Hyun;Lee, Hee-Dae;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.753-762
    • /
    • 2010
  • The objective of this study was to evaluate the backwashing frequency and method on the Granular Activated Carbon (GAC) in G WTP. A backwashing period was determined as 50 days and 60 days, respectively. Prior to Backwashing by head loss build, biomass concentration in effluent as constant and DO concentration was maintained more than 11.5 mg/L in GAC bed. Peak turbidity of backwashing water was 73.6~303 NTU. Mean turbidity of backwashing water at initial 9 minute of backwash operation was 50.7~82.8 NTU. After 30 minute backwashing operation, final turbidity reaches approximately 10 NTU. The frequency of backwashing and turbidity of backwashing water overtime were evaluated. At 20days of backwashing frequency, the peak turbidity was 73 NTU and 42 NTU respectively when 10% and 25% of expansion of GAC were applied. At 14 minute of backwashing time, it was observed that turbidity of 10% expansion of GAC was higher than that of 20% expansion.

Effect of Operating Parameters on Electrochemical Degradation of Rhodamine B by Three-dimensional Electrode (3차원 전극을 사용한 Rhodamine B의 전기분해에 미치는 운전인자의 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.295-303
    • /
    • 2009
  • A simulated wastewater containing the dye Rhodamine B (RhB) was electrolytically treated using a three-dimensional electrode reactor equipped with granular activated carbon (GAC) as particle electrode. The effect of type of packing material (GAC, ACF, Nonwoven fabric fiber coated with activated carbon), amounts of GAC packing (25-100 g), current (0.5-3 A) and electrolyte concentration (0.5-3 g/l) was evaluated. Experimental results showed that performance for RhB decolorization of the 3 three-dimensional electrodes lie in: GAC > Nonwoven fabric fiber > ACF. When considered RhB decolorization, oxidants concentration and electric power, optimum GAC dosage was 50 g. Generated concentration of 3 oxidants ($ClO_2$, free Cl, $H_2O_2$) was increased with increase of applied current, however optimum current for RhB degradation was 2.5 A. The oxidants concentration was increased with increase of NaCl concentration and optimum NaCl dosage for RhB degradation was 1.5 g/l.

Treatment of ETA wastewater using GAC as particle electrodes in three-dimensional electrode reactor (활성탄 충진 3D 복극전기분해조를 이용한 ETA 처리)

  • Kim, Ran;Kim, Yu-Jin;Shin, Ja-Won;Kim, Jeong-Joo;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.241-249
    • /
    • 2013
  • Ethanolamine (ETA) is widely used for alkalinization of water in steam cycles of nuclear power plants with pressurized water reactor. When ETA contained wastewater was released, it could increase COD and T-N. The treatment of the COD and T-N from ETA wastewater was investigated using the GAC as particle electrodes in three-dimensional electrode reactor (TDE). This study evaluated the effectiveness of GAC as particle electrode using different packing ratio at 300 V. The results showed that GAC-TDE could reduce ETA much more efficiently than ZVI-TDE at the mass ratio of GAC to insulator, 1:2. Additionally, The effect of applied electric potential to COD and T-N reduction was investigated. The results showed the high COD, T-N reduction and current efficiency at the low electric potential. Using the GAC-TDE will provide a better ETA reduction with reducing electrical potential dissipation.

A comparative study of granular activated carbon and sand as water filtration media with estimation of model parameters

  • Chatterjee, Jaideep;A, Shajahan;Pratap, Shailendra;Gupta, Santosh Kumar
    • Advances in environmental research
    • /
    • v.6 no.1
    • /
    • pp.35-51
    • /
    • 2017
  • The use of Granular Activated Carbon (GAC) and naturally occurring silica (Sand) as filtration media in water and waste water treatment systems is very common. While GAC offers the additional functionality of being an "adsorptive" filter for dissolved organics it is also more expensive. In this paper we present an experimental evaluation of the performance of a bed of GAC for colloid removal and compare the same with that from an equivalent bed of Sand. The experiments are performed in an "intermittent" manner over extended time, to "simulate" performance over the life of the filter bed. The experiments were continued till a significant drop in water flow rate through the bed was observed. A novel "deposition" and "detachment" rate based transient mathematical model is developed. It is observed that the data from the experiments can be explained by the above model, for different aqueous phase electrolyte concentrations. The model "parameters", namely the "deposition" and "detachment" rates are evaluated for the 2 filter media studied. The model suggests that the significantly better performance of GAC in colloid filtration is probably due to significantly lower detachment of colloids from the same. While the "deposition" rates are higher for GAC, the "detachment" rates are significantly lower, which makes GAC more effective than sand for colloid removal by over an order of magnitude.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of GAC Packing Fraction (세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 입상 활성탄 충전율에 의한 영향)

  • Park, Jin-Yong;Lee, Hyuk-Chan
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • In this study, we used hybrid module that was composed of packing granular activated carbon (GAC) between module inside and outside of ceramic microfiltration membrane for advanced drinking water treatment. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, synthetic water was prepared with humic acid and kaolin. Packing fraction of GAC was changed from 0 to 24.05% to see effect of packing fraction. As a result, changing curves of resistance of membrane fouling ($R_f$) and permeate flux (J) during 3 h operation were almost overlapped independent of packing fraction of GAC. Treatment efficiencies of turbidity were very high above 99.46% at all packing fractions of GAC. And treatment efficiency of NOM, which was measured by $UV_{254}$ absorbance, was the highest value of 99.43% at packing fraction of 24.05%. Then, we operated the hybrid process during 13 h at packing fraction of 24.05%. As a result, J was rapidly dropped according to increase of membrane fouling within initial 1 h of operation, and almost constant after 3 h. And treatment efficiencies of turbidity and NOM were stable and high values of 99.52% and 96.63%, respectively.

An Experimental Study on the Toluene Control Characteristics of Biofilter Packed with Compost, Peatmoss and GAC (Compost, Peatmoss, GAC의 복합 메디아로 충전된 Biofilter의 Toluene 제어특성에 관한 실험적 연구)

  • Eom, Yun-Sung;Han, Se-Hyun;Jung, Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.265-276
    • /
    • 2007
  • The primary objective of this study is to investigate the effect of media on the performance of biofilters. Two types of experiments were carried out in this study. The first type of experiment used a biofilter with the media composed of three different packing materials of compost, peatmoss and GAC(granular activated carbon), whereas the second type used a biofilter with the media composed of compost only. It was found from the two experiments that the biofilter composed of compost, peatmoss and GAC showed better performance than the one composed of compost only with the higher toluene removal efficiency, lower pressure drop, and more uniform media moisture content. In particular, no appreciable media compression occurred for the biofilter composed of compost, peatmoss and GAC, whereas significant media compression took place in the biofilter composed of compost only. As suggested by the other researchers, it is likely that GAC may be responsible for the higher toluene removal efficiency in the case of the biofilter composed of mixed media especially for the early stage of biofiltration due to its adsorption capability of toluene of such high concentration as 300 ppm. It was also regarded that GAC may playa major role in maintaining lower media pressure drop in the case of the mixed media than the media with compost only because of its mechanical strength resisting to the compression. Nonetheless, further refined experiments may need to draw more accurate conclusion. The results of the additional test run using the same mixed media showed that the biofilter system using the mixed media can be consistently operated for more than 100 days very stably despite sudden change in operating conditions of temperature and flow rate.

Bacterial regrowth in biofilms formed in granular activated carbon filter adsorbers and the bacterial isolation and identification (입상 활성탄 여과지에서 세균의 재성장과 생물막 형성 세균의 분리 및 동정)

  • Lee, Gyucheol;Kwon, Soonbok;Lee, Byungki;Park, Jonggeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.205-212
    • /
    • 2008
  • This study aimed to investigate the biofilm formation, bacterial regrowth, and bacterial community structure in the granular-activated carbon (GAC) filter adsorbers (FAs) used in water treatment plants. In 2005 and 2006, raw water, settled water, GAC FA by depth, and filtered water were collected twice a year from water treatment plants (WTPs) B and S. The number of heterotrophic bacteria, including mesophilic and psychrophilic bacteria, in such collected waters was investigated along with the total number of coliforms therein. Heterotrophic bacteria were detected in most samples, mainly at the surface layers of the GAC FAs, and fewer such bacteria were found in the lower and bottom layers. An increase in the bacterial number, however, was observed in the samples from various depths of the GAC FAs in WTPs B and S compared with the surface layers. An increase in the bacterial number was also detected in the filtered water. This may indicate that there is a regrowth of the bacteria in the GAC FA. Considering, however, that heterotrophic bacteria were not found in the filtered water, it can be deduced that most bacteria are removed in the chlorination process. Coliforms were detected at the surface layer of the GAC FAs, but their regrowth was not observed. MicroLog systems were used to identify the bacteria community distribution. Eight genera and 14 species, including Pseudomonas spp., were detected in WTP B, and 8 genera and 9 species, including Aeromonas spp., in WTP S. Further studies are required to elucidate their role in the biofilms in water treatment processes.

Removal of Phenol Loaded with Activated Carbon by Potentiostatic Method (정전위전해에 의한 활성탄에 함유된 페놀 제거)

  • 김성우;박승조
    • Resources Recycling
    • /
    • v.10 no.4
    • /
    • pp.18-23
    • /
    • 2001
  • Air pollutants, phenol was generated in case of thermal regeneration of used activated carbon loaded with phenol and because of this problem, removal process of phenol were studied. Electrolytic oxidation of samples, used S.company granular activated carbon (WS-GAC), used C.company granular activated carbon (WC-GAC) and used L.company granular activated carbon (WL-GAC) loaded with phenol carried out by potentiostatic method in this study. In case of experiment was to come into operation in condition of samples containing 100 mg/g phenol, supporting electrolyte was 1.0% sodium chloride solution, Ti-Ir (10$\times$10$\textrm{cm}^2$) electrode and electrode distance was 2 cm, current density was $1.25 A/dm^2$, Obtained from the results of electrolytic oxidation experiments were not detected residual phenol. And then we knew about reaction time of electrolytic oxidation, current density, concentration of supporting electrolyte and electrode and electrode distance were 60 minutes, 1.25 A/dm$^2$, 1.0%, 2 cm.

  • PDF