• Title/Summary/Keyword: G3 calculation

Search Result 365, Processing Time 0.024 seconds

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

Survey on the Status of C. sinensis Infection in Rural Inhabitants (Yeoju Eup, Kyunggi Do) (농촌지역 주민(여주읍)에 있어서 간흡충 감염현황 조사 - 학생을 통한 대변수집 방안 및 결과 -)

  • Chung, Myung-Sook;Lee, Joon-Sang;Rim, Han-Jong;Yum, Yong-Tae;Cha, Chul-Whan;Koo, Bum-Hwan
    • Journal of agricultural medicine and community health
    • /
    • v.11 no.1
    • /
    • pp.3-11
    • /
    • 1986
  • In order to observe the infestation rate and intensity of C. sinensis in Yeoju Eup, Kyung-gi Do, 9,512 stool specimens were collected from the inhabitants through student's helps. The specimens were examined by cellophane thick smear technique and Stoll's egg dilution technique. The epidemiological status was analysed statistically by the regession equation and catalytic curve with the results obtained from this area. The results are as follows: 1) Collection rate oft he stool samples was 66.5%, 9.512 out of 14,300 inhabintants complied with our survey. 2) The infestation rate of C.sinensis was 5.0%, and for male 7.8%, for female 2.3%. 3) Average E.P.G. by Stoll's egg dilution technique in this area was 1,572, and for male 1,853, for female 676. 4) The degree of the intensity of C. sinensis infection by E.P.G. count was distributed as 65.2% in light infection, 32.0 % in moderate infection, 2.8% in heavy infection and none in very heavy infection. 5) The intensity of endemicity in this area was represented with the regression equation calculated with cumulative percentages of E.P.G. counts. Regression equation was y=3.887+1.695 log x and Cs. $D_{50}$ was 4.54. 6) The two-stage catalytic model was applied and the calculation lead to the equation $y=0.267(e^{-0.004t}-e^{-0.019t})$; a=0.004 < b=0.019. 7) Other helminthic infection rate in this area was 1.4% in A.lumbricoides 2.7% in T. trichiura, 1.6% in M. yokogawai md 0.2% in Taenia sp. respectively.

  • PDF

Risk Assessment of 5-Chloro-2-Methylisothiazol-3(2H)-One/2-Methylisothiazol-3(2H)-One (CMIT/MIT) Used as a Preservative in Cosmetics

  • Kim, Min Kook;Kim, Kyu-Bong;Lee, Joo Young;Kwack, Seung Jun;Kwon, Yong Chan;Kang, Ji Soo;Kim, Hyung Sik;Lee, Byung-Mu
    • Toxicological Research
    • /
    • v.35 no.2
    • /
    • pp.103-117
    • /
    • 2019
  • The mixture of 5-chloro-2-methylisothiazol-3(2H)-one (CMIT) and 2-methylisothiazol-3(2H)-one (MIT), CMIT/MIT, is a preservative in cosmetics. CMIT/MIT is a highly effective preservative; however, it is also a commonly known skin sensitizer. Therefore, in the present study, a risk assessment for safety management of CMIT/MIT was conducted on products containing 0.0015% of CMIT/MIT, which is the maximum MIT level allowed in current products. The no observed adverse effect level (NOAEL) for CMIT/MIT was 2.8 mg/kg bw/day obtained from a two-generation reproductive toxicity test, and the skin sensitization toxicity standard value for CMIT/MIT, or the no expected sensitization induction level (NESIL), was $1.25{\mu}g/cm^2/day$ in humans. According to a calculation of body exposure to cosmetics use, the systemic exposure dosage (SED) was calculated as 0.00423 mg/kg bw/day when leave-on and rinse-off products were considered. Additionally, the consumer exposure level (CEL) amounted to $0.77512{\mu}g/cm^2/day$ for all representative cosmetics and $0.00584{\mu}g/cm^2/day$ for rinse-off products only. As a result, the non-cancer margin of safety (MOS) was calculated as 633, and CMIT/MIT was determined to be safe when all representative cosmetics were evaluated. In addition, the skin sensitization acceptable exposure level (AEL)/CEL was calculated as 0.00538 for all representative cosmetics and 2.14225 for rinse-off products; thus, CMIT/MIT was considered a skin sensitizer when all representative cosmetics were evaluated. Current regulations indicate that CMIT/MIT can only be used at concentrations 0.0015% or less and is prohibited from use in other cosmetics products. According to the results of this risk assessment, the CMIT/MIT regulatory values currently used in cosmetics are evaluated as appropriate.

The Synthesis of Eu3+ Doped with TiO2 Nano-Powder and Application as a Pesticide Sensor

  • Yao, Fei;Sun, Yang;Tan, Chunlei;Wei, Song;Zhang, Xiaojuan;Hu, Xiaoyun;Fan, Jun
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.6
    • /
    • pp.932-935
    • /
    • 2011
  • Using tetrabutyl titanate as precursor, $Eu^{3+}$ doped $TiO_2$ nano-powder was prepared by sol-gel method, the nature of luminescence of nano-powder was studied. The interaction of chlorpyrifos with $Eu^{3+}$ doped $TiO_2$ was studied by absorption and fluorescence spectroscopy. The results indicated the fluorescence intensity of $Eu^{3+}$ doped $TiO_2$ was quenched by chlorpyrifos and the quenching rate constant ($k_q$) was $1.24{\times}10^{11}\;L/mol{\cdot}s$ according to the Stern-Volmer equation. The dynamics of photoinduced electron transfer from chlorpyrifos to conduction band of $TiO_2$ nanoparticle was observed and the mechanism of electron transfer had been confirmed by the calculation of free energy change (${\Delta}G_{et}$) by applying Rehm-Weller equation as well as energy level diagram. A new rapid method for detection of chlorpyrifos was established according to the fluorescence intensity of $Eu^{3+}$ doped $TiO_2$ was proportional to chlorpyrifos concentration. The range of detection was $5.0{\times}10^{-10}-2.5{\times}10^{-7}mol/L$ and the election limit ($3{\sigma}$) was $3.2{\times}10^{-11}$ mol/L.

Frontier Orbitals of Fifteen C20H17(OH)3 Regioisomers: Hybrid DFT B3LYP Study

  • Lee, Seol;Lee, Ji Young;Lee, Kee Hag
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2403-2407
    • /
    • 2013
  • The hybrid density-functional (B3LYP/6-31G(d,p)) method was used to analyze the substitution effect on the $C_{20}H_{20}$ cage based on calculation of the frontier orbitals of fifteen $C_{20}H_{17}(OH)_3$ derivatives. All substitution products were geometrically optimized without constraints and confirmed by frequency analysis. The results suggest that the cis-1 cis-1 cis-2 regioisomer is the most stable isomer, which implies that hydrogen bonding exerts a stronger effect on the relative energies of the trihydroxide than long-range interactions. Thus, this supports the experimental result in which the bisvicinal tetrol was of particular preparative-synthetic interest. While the LUMO of each of the $C_{20}H_{17}(OH)_3$ regioisomers was equivalently delocalized over the void within the cage, the HOMO was limitedly delocalized on substituents and carbons in close proximity to the substituents. The characteristics of the HOMO of each of the regioisomers vary based on the substitution sites. This indicates that the 15 regioisomers of each $C_{20}H_{20}$ trisubstituted derivative might undergo an entirely different set of characteristic chemical reactions with electrophilic reagents. The results further suggest that the penta-substituted OH groups on the surface of the fullerene cage are more likely to be localized on a pentagon than to be homogeneously delocalized.

ESTIMATION OF ROLL COEFFICIENT OF UNDERWATER VEHICLE USING A CALCULATION OF HYDRODYNAMIC FORCES (동유체력 계산을 이용한 수중운동체의 횡동요 계수 변화 예측)

  • Kim, T.W.;Kang, T.J.;Park, W.G.;Jung, C.M.
    • Journal of computational fluids engineering
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • For Underwater vehicles, Unwanted roll excursions are inevitable as they are caused by induced propeller torque, disturbances, and banking motion during turns. To estimate the manoeuvring performance of underwater vehicle, it is necessary to obtain the roll coefficient of body. This paper was covered estimation of roll coefficient of underwater vehicle using STAR-CCM+, commercial CFD(Computational Fluid Dynamics) code. The RANS equations for incompressible fluid flows was solved numerically by using a finite volume method. An MRF(Moving Reference Frame) Method was Also adopted for rotations of body. For the validation, the flow around a DARPA SUBOFF bare hull model was simulated and good agreement with experiments was obtained. And Pure roll coefficients were calculated and campared with the experimental data which were presented by Seoul National University. Finally, an underwater vehicle model with propeller was simulated and analyzed for estimation of roll coefficient variation caused by induced propeller torque.

Population Pharmacokinetic Modeling of Vancomycin in Patients with Cancer (암환자에게 반코마이신의 집단약물동태학 모델연구)

  • 최준식;민영돈;범진필
    • YAKHAK HOEJI
    • /
    • v.43 no.2
    • /
    • pp.160-168
    • /
    • 1999
  • The purpose of this study was to determine pharmacokinetic parameters of vancomycin using peak and trough plasma level (PTL) and Bayesian analysis in 20 Korean normal volunteers, 16 gastric cancer and 12 lymphoma patients and also using the compartment model dependent (nonlinear least squares regression: NLSR) and compartment model independent (Lagrange) analysis in 10 ovarian cancer patients. Nonparametric expected maximum (NPEM) algorithm for calculation of the population pharmacokinetic parameters was used, and these parameters were applied for clinical pharmacokinetic parameters by Bayesian analysis. Vancomycin was administered as dose of 1.0 g every 12 hrs for 3 days by IV infusion over 60 minutes in normal volunteers, gastric cancer and lymphoma patients. Population pharmacokinetic parameters, K and Vd in gastric cancer and lymphoma patients using NPEM algorithm were $0.158{\pm}0.014{\;}hr^{-1},{\;}0.630{\pm}0.043{\;}L/kg{\;}and{\;}0.131{\pm}0.0261{\;}hr^{-1},{\;}0.631{\pm}0.089{\;}L/kg$ respectively. The K and Vd in gastric cancer and lymphoma patients using Bayesian analysis were $0.151{\pm}0.027,{\;}0.126{\pm}0.056{\;}hr^{-1}{\;}and{\;}0.62{\pm}0.105,{\;}0.63{\pm}0.095{\;}L/kg$. The K and Vd in ovarian cancer patient using the NLSR and Lagrange analysis were $0.109{\pm}0.008,{\;}0.126{\pm}0.012{\;}hr^{-1}{\;}and{\;} 0.76{\pm}0.08,{\;}0.69{\pm}0.19{\;}L/kg$, respectively. It is necessary for effective dosage regimen of vancomycin in cancer patients to use these population parameters.

  • PDF

A study on the calculation model for emissivities of combustion gases (燃燒氣體의 放射率 計算模型에 관한 硏究)

  • 허병기;이청종;양지원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.6
    • /
    • pp.904-912
    • /
    • 1987
  • The main mode of heat transfer of combustion gases at high temperature is thermal radiation of nonluminous gases, CO$_{2}$ and H$_{2}$O. Therefore the information of the emissivities of CO$_{2}$ and H$_{2}$O would be very important in the thermal performance analysis of furnace. In this study, an exponential model for the emissivities of CO$_{2}$ and H$_{2}$O was derived as function of P$_{g}$L and polynomial of reciprocal of temperature. Error analysis between the calculated values from present model and the valued of Hottel Chart was performed over temperature range of 1000-5000 R and a partial-pressure-length product range of 0.003 to 20 ft-atm. For CO$_{2}$ gray gas, the error percent between the calculated values and the values from Hottel Chart was distributed within 2.5% in case of using a polynomial in 1/T of degree 4. For H$_{2}$O gray gas, the model has an error range of 0 to 2.5% in case of using a polynomial in 1/T of degree 3.

Metabolic Flux Distribution in a Metabolically Engineered Escherichia coli Strain Producing Succinic Acid

  • Hong, Soon-Ho;Lee, Sang-Yup
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.4
    • /
    • pp.496-501
    • /
    • 2000
  • Escherichia cole NZN111, which is known as a pfl ldhA double mutant strin, was metabolically engineered to produce succinic acid by overexpressing malic enzyme into the E. coli controlled by a trc promoter. Fermentation studies were carried out in a LB medium by first growing cells aerobically to an $OD_{600}$ of 5. At this point, 0.01 mM IPTG was added to induce the overexpression of malic enzyme and the agitation speed was gradually lowered. When the culture $OD_{600}$ reached 11, a complete anaerobic condition was achieved by flushing with a $CO_3-H_2$ gas mixture. When NZN111(pTrcML) was cultured at $37^{\circ}C$, the final succinic acid concentration of 2.8 g/l could be obtained after 30 h of anaerobic cultivation. The fermentation results were analyzed by the calculation of metabolic fluxes. Metaolic flux analysis showed that about 85% of phosphoenolpyruvate (PEP) was converted to pyruvate, and further converted to malic acid by malic enzyme.

  • PDF

Velocity and Pressure Measurement of Channel Cavity Flow by PTV (PTV에 의한 채널캐비티 유동의 속도 및 압력계측)

  • Cho, D.H.;Kim, J.G.;Lee, Y.H.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.59-66
    • /
    • 1997
  • The present study adopted the PTV method for the velocity acquisition. The system consists of an image grabber built-in a personal computer and a laser-based sheet light projector and particle identification softwares. Velocity vectors are obtained, by PTV and they are used as velocity components for Poisson equation for pressure. Related boundary conditions and no-slip condition at solid wall and the linear velocity extrapolation on the upper side of cavity are well examined for the present study. For calculation of pressure, resolution of grid is basically $40{\times}40$ and 2-dimensional uniform mesh using MAC staggered grid is adopted. The result of experiment reveal that, newly suggested measuring method is capable of estimating pressure and velocity distribution of flow field reasonably.

  • PDF