• Title/Summary/Keyword: G-sensitivity

Search Result 1,367, Processing Time 0.03 seconds

Serotypes and Sensitivity Distribution of Pseudomonas aeruginosa (임상재료에서 분리된 녹농균의 혈청형과 약제 감수성과의 관계)

  • Park, Kwang-Woong;Cho, Yang-Ja
    • The Journal of the Korean Society for Microbiology
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 1982
  • The correlation between the serotypes and sensitivity distribution of Pseudomonas aeruginosa was studied with stock strains of department, strains isolated from various clinical sources and strains of haspital environment of the past two years. Two hundred and fifty seven strains were typable and 38 strains were untypable out of 295 clinical sorces. Serotype B was most provalent(27.6%) followed by serotype G(24.9%), serotype E(23.3%) and serotype A(7.8%) among 257 typable strains. However, no serotype J,L and M were observed. Serotype B,G,E and A were isolated from pus, sputum, wound, burn site and urine. Serotypes E were most frequently isolated from nasal discharge and serotypes K were isolated from pus. There were no apparent differences in sensitivity distribution of streptomycin, carbenicillin and ampicillin between the clinical and The environmental origin. However, the strains of environmental origin were found to be relatively more susceptable to tetracycline, gentamicin and fradiomycin than the strains of clinical sources in high concentration. The strains of clinical sources of serotype B,G,E and A showed different resistant patterns to all antimicrobial agents except for carbenicillin. Serotype E showed the highest percentage resistance followed by serotype G,B and A.

  • PDF

Design, Fabrication, Static Test and Uncertainty Analysis of a Resonant Microaccelerometer Using Laterally-driven Electrostatic Microactuator (수평구동형 정전 액추에이터를 이용한 금속형 공진가속도계의 설계, 제작, 정적시험 및 오차분석)

  • Seo, Yeong-Ho;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.520-528
    • /
    • 2001
  • This paper investigates a resonant microaccelerometer that measures acceleration using a built-in micromechanical resonator, whose resonant frequency is changed by the acceleration-induced axial force. A set of design equations for the resonant microaccelerometer has been developed, including analytic formulae for resonant frequency, sensitivity, nonlinearity and maximum stress. On this basis, the sizes of the accelerometer are designed for the sensitivity of 10$^3$Hz/g in the detection range of 5g, while satisfying the conditions for the maximum nonlinearity of 5%, the minimum shock endurance of 100g and the size constraints placed by microfabrication process. A set of the resonant accelerometers has been fabricated by the combined use of bulk-micromachining and surface-micromachining techniques. From a static test of the cantilever beam resonant accelerometer, a frequency shift of 860Hz has been measured for the proof-mass deflection of 4.3${\pm}$0.5$\mu\textrm{m}$; thereby resulting in the detection sensitivity of 1.10${\times}$10$^3$Hz/g. Uncertainty analysis of the resonant frequency output has been performed to identify important issues involved in the design, fabrication and testing of the resonant accelerometer.

Relative Sensitivity Analysis of the Soil Water Characteristics Curve

  • Eom, Ki-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.6
    • /
    • pp.712-723
    • /
    • 2015
  • This study was conducted to develop the SWCC estimation equation using scaling technique, and to investigate relative sensitivity of the SWCC according to the soil water tension, for the four kinds of soil texture such as Sand [S], Sandy Loam [SL], Loam [L] and Clay Loam [CL]. The SWCC estimation equation of scale factor [${\Theta}sc$] (Eq. 1) was developed based on the log function (Eq. 2) and exponential function (Eq. 3). ${\Theta}sc=[({\Theta}-{\Theta}r)/({\Theta}s-{\Theta}r)]$ (Eq. 1) ${\Theta}sc=-0.196ln(H)+0.4888$ (Eq. 2) ${\Theta}sc=0.3804(H)^{(-0.448)}$ (Eq. 3) where, ${\Theta}$: water content (g/g %), ${\Theta}s$: water content at 0.1bar, ${\Theta}r$: water content at 15bar, H: soil water tension (matric potential) (bar) Relative sensitivity of soil water content was decreased as increase soil water tension, those according to soil water tension were 0.952~0.620 compared to 0.1bar case. Relative sensitivity of scale factor was also decreased as increase soil water tension, those according to soil water tension were 0.890~0.577 compared to 0.2bar case.

Research on Optimizing Luminosity Factor Through Color Filter $Y_{1-X}G_X$, $Y_{1-X}P_X$ ($Y_{1-X}G_X$, $Y_{1-X}P_X$ 칼라필터를 통한 시감도 최적화 연구)

  • Kim, YongGeun;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.47-56
    • /
    • 2009
  • Purpose: To find optimized luminosity factor of color from light transmission filter. Methods: To make $Y_{1-x}G_{x}$, $Y_{1-x}P_{x}$ by using CR-39 compound within dipping method, mixing up Y(Yellow), G(green) and P(pink) for optimize eye sensitivity. Modeling for relative luminous efficiency(relative sensitivity) curves in Luminose transmission, it could be resolved by Multiplying sensitivity of eye within transmission rate of Lens ($P_f({\lambda}=T({\lambda}){\cdot}P({\lambda}).)$.). To evaluate Wavelength between 400~700 nm, relative luminous efficiency curve in Area and Height value is being used. Results: In color filter of $Y_{1-x}G_{x}$ position of x equals to 0.04, 0.1, 0.08, 0.12, 0.14, 0.5 at ${\beta}=S_1/S_0{\cdot}100$ each consist value of 76.1, 77.9, 80.7, 81.6, 80.2, 18.6 In color filter of $Y_{1-x}P_{x}$ position of x equals to 1.00, 0.2, 0.6, 0.8 at ${\beta}=S_1/S_0{\cdot}100$ each consist value of 74.3, 74.0, 70.5, 33.0 The result from experiment $Y_{1-x}P_{x}$ value less than $Y_{1-x}G_{x}$, from evaluating luminous efficiency curve and test was successfully optimized. Conclusions: Optimized relative luminous efficiency curve result have value of X=0.12-0.14 at $Y_{1-x}G_{x}$.

  • PDF

High-sensitivity NIR Sensing with Stacked Photodiode Architecture

  • Hyunjoon Sung;Yunkyung Kim
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.200-206
    • /
    • 2023
  • Near-infrared (NIR) sensing technology using CMOS image sensors is used in many applications, including automobiles, biological inspection, surveillance, and mobile devices. An intuitive way to improve NIR sensitivity is to thicken the light absorption layer (silicon). However, thickened silicon lacks NIR sensitivity and has other disadvantages, such as diminished optical performance (e.g. crosstalk) and difficulty in processing. In this paper, a pixel structure for NIR sensing using a stacked CMOS image sensor is introduced. There are two photodetection layers, a conventional layer and a bottom photodiode, in the stacked CMOS image sensor. The bottom photodiode is used as the NIR absorption layer. Therefore, the suggested pixel structure does not change the thickness of the conventional photodiode. To verify the suggested pixel structure, sensitivity was simulated using an optical simulator. As a result, the sensitivity was improved by a maximum of 130% and 160% at wavelengths of 850 nm and 940 nm, respectively, with a pixel size of 1.2 ㎛. Therefore, the proposed pixel structure is useful for NIR sensing without thickening the silicon.

Screening for Colorectal Neoplasias with Fecal Occult Blood Tests: False-positive Impact of Non-Dietary Restriction

  • Roslani, April Camilla;Abdullah, Taufiq;Arumugam, Kulenthran
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.237-241
    • /
    • 2012
  • Objective: Screening for colorectal cancer using guaiac-based fecal occult blood tests (gFOBT) is well established in Western populations, but is hampered by poor patient compliance due to the imposed dietary restrictions. Fecal immunochemical tests (FIT) do not require dietary restriction, but are more expensive than gFOBT and therefore restrict its use in developing countries in Asia. However, Asian diets being low in meat content may not require diet restriction for gFOBT to achieve equivalent results. The objective of this study was to evaluate and compare the validity and suitability of gFOBT and FIT or a combination of the two in screening for colorectal neoplasias without prior dietary restriction in an Asian population. Methods: Patients referred to the Endoscopic Unit for colonoscopy were recruited for the study. Stool samples were collected prior to bowel preparation, and tested for occult blood with both gFOBT and FIT. Dietary restriction was not imposed. To assess the validity of either tests or in combination to detect a neoplasm or cancer in the colon, their false positive rates, their sensitivity (true positive rate) and the specificity (true negative rate) were analyzed and compared. Results: One hundred and three patients were analysed. The sensitivity for picking up any neoplasia was 53% for FIT, 40% for gFOBT and 23.3% for the combination. The sensitivities for picking up only carcinoma were 77.8%, 66.7% and 55.5%, respectively. The specificity for excluding any neoplasia was 91.7% for FIT, 74% for gFOBT and 94.5% for a combination, whereas for excluding only carcinomas they were 84%, 73.4% and 93.6%. Of the 69 with normal colonoscopic findings, FOBT was positive in 4.3%, 23.2 %and 2.9% for FIT, gFOBT, or combination of tests respectively. Conclusion: FIT is the recommended method if we are to dispense with dietary restriction in our patients because of its relatively low-false positivity and better sensitivity and specificity rates.

A Design Using Sensitivity Information (민감도 정보를 이용한 설계 방법)

  • Kim, Y.I.;Yi, J.W.;Park, G.J.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1248-1253
    • /
    • 2003
  • Sensitivity information has been used for linearization of nonlinear functions in optimization. Basically, sensitivity is a derivative of a function with respect to a design variable. Design sensitivity is repeatedly calculated in optimization. Since sensitivity calculation is extremely expensive, there are studies to directly use the sensitivity in the design process. When a small design change is required, an engineer makes design changes by considering the sensitivity information. Generally, the current process is performed one-by-one for design variables. Methods to exploit the sensitivity information are developed. When a designer wants to change multiple variables with some relationship, the directional derivative can be utilized. In this case, the first derivative can be calculated. Only small design changes can be made from the first derivatives. Orthogonal arrays can be used for moderate changes of multiple variables. Analysis of Variance is carried out to find out the regional influence of variables. A flow is developed for efficient use of the methods. The sensitivity information is calculated by finite difference method. Various examples are solved to evaluate the proposed algorithm.

  • PDF

Improvement of the Ammonia Analysis by the Phenate Method in Water and Wastewater

  • Park, Ga-Eun;Oh, Ha-Na;Ahn, Sam-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2032-2038
    • /
    • 2009
  • The amount of phenol and NaOH for the colorimetric determination of ammonia in Korean standard methods (KSM) is found to be highly excessive compared to the standard methods of several other countries. The absorbance of indophenol formed by the Berthelot reaction for ammonia analysis was measured under the various reaction conditions classified in experiment groups 1, 2, 3, 4 and KSM and American standards methods (ASM), and the relationships between the absorbance of indophenol and concentration of ammonia were compared. The amount of phenol can be reduced to 10 g (current 25 g in KSM) and NaOH can be reduced to 1.76 g (current 11 g in KSM) for the preparation of 200 mL phenate solution, and the absorbance sensitivity increased. The concentration of the phenol and NaOH correlatively affect the pH of the solution, which is a critical variable in achieving the maximum sensitivity and rapid and stable color development.

Evaluation of Image Quality by Using Various Detector Materials according to Density : Monte Carlo Simulation Study (몬테카를로 시뮬레이션 기반 밀도에 따른 다양한 검출기 물질을 적용한 획득 영상 평가)

  • LEE, Na-Num;Choi, Da-Som;Lee, Ji-Su;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.459-464
    • /
    • 2021
  • The detector performance is important role in acquiring the gamma rays from patients. Among parameters of detector performances, there is density, which relates to respond to gamma rays. Therefore, we confirm the detection efficiency according to various detector materials based on the density parameter using GATE (geant4 application for emission tomography) simulation tool. The NaI (density: 3.67 g/cm3), CZT (Cadimium Zinc Telluride) (density: 5.80 g/cm3), CdTe (Cadmium Telluride) (5.85 g/cm3), and GAGG (Gadoinium Aluminum Gallium Garnet) (density g/cm3) were used as detector materials. In addition, the point source and quadrant bar phantom, which is modeled for 0.5, 1.0, 1.5, and 2.0 mm thicknesses, were modeled to confirm the quatitative analysis using sensitivity (cps/MBq) and the full width at half maximum (FWHM, mm) at the 2.0 mm bar thickness containing visual evaluation. Based on the results, the sensitivity for NaI, CZT, CdTe, and GAGG detector materials were 0.12, 0.15, 0.16, and 0.18 cps/MBq. In addition, the FWHM for quadrant bar phantom in the 2.0 mm bar thickness is 3.72, 3.69, 3.70, and 3.73 mm for NaI, CZT, CdTe, and GAGG materials, respectively. Compared with performance of detector materials according to density, the high density can improve detection efficiency in terms of sensitivity and mean count. Among these detector materials, the GAGG material is efficient for detection of gamma rays.