• Title/Summary/Keyword: G-민감도

Search Result 505, Processing Time 0.032 seconds

Magnetoresistive Properties of Array IrMn Spin Valves Devices (어레이 IrMn 스핀밸브 소자의 자기저항특성 연구)

  • Ahn, M.C.;Choi, S.D.;Joo, H.W.;Kim, G.W.;Hwang, D.G.;Rhee, J.R.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.

Detection of Antibodies in Serum and Cerebrospinal Fluid to Tonoplasma gondii by Indirect Latex Agglutination Test and Enzyme-Linked Immunosorbent Assay (간접 Latex 응집반응과 ELISA에 의한 중추신경계 질환 환자의 혈청 및 뇌척수액에서 Toxoplasmu gondii에 대한 항체 검출)

  • 최원영;남호우
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.2
    • /
    • pp.83-90
    • /
    • 1992
  • Sensitivity of anti-Texoplasma antibody (IgG) test by enzyme·linked immunosorbent assay (ELISA) was evaluated in comparison with indirect laten agglutination (ILA) using 2,016 paired human samples of serum and cerebrospinal quid (CSF) . The samples were collected from neurologic patients in Korea with mass lesions in central nervous system(CNS) as revealed by imaging diagnosis(CTIMRI). When the sera were screened for anti-Toxoplasma antibody by ILA, 76 cases (3.8%) were positive (1:32 or higher titers). In the pairs samples of CSF, no positive reactions were observed. When ELISA was performed using PBS extract of Percoll purified tachysoites as antigen, cut-off absorbance was determined as 0.40 for serum and 0.27 for CSF tests. The antibody positive rates by ELISA were 7.0% in serum and 5.6% in CSF Of them, 40 cases(2.0%) showed positive reactions in both serum and CSF, The antibody positive rates were higher in groups older than 40 years, The rates were higher in male(4.7% by ILA, 8.3% by ELISA) than in female(2.2% by ILA, 5.0% by ELISA). The rates in CSF showed no such sex difference. ELISA showed twice higher positive rates when serum was tested, and was sensitive enough to detect specific antibodies in CSF. Etiologic relations between positive antibody tests and CNS lesions remained unknown.

  • PDF

A Proposal on Modified g-index for Evaluating Research Performance (연구성과 평가를 위한 g-지수의 변형 지수 제안)

  • Lee, Jae Yun
    • Journal of the Korean Society for information Management
    • /
    • v.34 no.3
    • /
    • pp.209-228
    • /
    • 2017
  • This study suggests a new Hirsch-type composite index, 'transposed g-index' with a different viewpoint on h-index and g-index. From this new point of view, the axes of the graph describing the h-index and g-index are transposed so that the horizontal axis corresponds to the citation frequency threshold and the vertical axis corresponds to the number of documents. Based on this transposed graph, a new indicator transposed g-index is suggested and applied to library and information science researchers' outcomes in Korean Citation Index database. The results show that this new index has more discriminating power than h-index and g-index, and is more sensitive to differences in quantitative aspects than quality of research. It is expected that the transposed g-index will be helpful for the multifaceted evaluation of the research outcome because it has differentiating characteristics that distinguish consistent researchers who continue to study from those who do not.

A Study on the Framework of Customer Orientation, Interest Rate Sensitivity, and Customer Loyalty in the Banking Services: The Moderating Roles of Deposit Interest and Loan Interest Rates (은행서비스에서 고객지향성, 금리민감도, 고객애호도의 구조에 관한 연구: 예금이자율과 대출이자율의 조절효과)

  • Ha, Hong-Youl;Choi, Chang-bok
    • Asia Marketing Journal
    • /
    • v.12 no.3
    • /
    • pp.43-62
    • /
    • 2010
  • The notion of customer orientation is now importantly considered in the context of banking industries. Despite customer-oriented organizational cultures, there are few studies addressing the relationship between customer orientation and its outcomes. In particular, this study aims at testing the effect of customer orientation as a key marketing effort designed by a bank. This is because interest rate sensitivity is critical for evaluating banking services after raising the base rate. In so doing, first, this study investigates the relationships among customer orientation, interest rate sensitivity, and customer loyalty. Second, this paper examines how the moderating effects of both deposit interest and loan interest rates influence the linkages of customer orientation-interest rate sensitivity and customer orientation-customer loyalty. To test the proposed model, research data are collected from 304 subjects who use banking services(e.g., Shin-Han, Kookmin, the First Bank, Hana, and Woori banks). Each construct was measured by published items and the psychometric properties of the three constructs, excluding two constructs of the moderators, were evaluated by employing the method of confirmatory factor analysis via the use of AMOS. The model fit was also evaluated using the CFI, TLI, and RMSEA fit indices that are recommended based on their relative stability and insensitivity to sample size. The findings show that the relationship between customer orientation and customer loyalty is significant, whereas the relationships between customer orientation and interest rate sensitivity and between interest rate sensitivity and customer loyalty are not supported. Although customer orientation is highly evaluated, customers' interest rate sensitivity that results in the comparison of interest rates plays an important role in reducing the effect of customer orientation. As a consequence, interest rate sensitivity does not influence customer loyalty. First of all, one of interesting results in this study is that the moderating effect of loan interest rate is quite different from deposit interest rate. In the case of deposit interest rate, the linkages both customer orientation-interest rate sensitivity and customer orientation-customer loyalty are insignificant. In the case of loan interest rate, however, the two proposed linkages are supported. As our proposed relationships are still in its infancy in the context of banking industry, our study contributes to enhance scholars' knowledge of bank services and provides insights for practitioners when their marketing strategies, particularly both deposit and interest rates, have to be established. Finally, this research also illuminates the need for further research that considers the influence of customer orientation on consumer's decision-making and bank profits. More specifically, the results are encouraging and will lead us to further investigate this key outcome of the banking deposit/interest rates.

  • PDF

A Seamless Voice Call Handover Scheme for the 3G LTE System (3G LTE 시스템을 위한 끊김없는 음성 호 핸드오버 방법)

  • Kim, Kyung-Min;Jung, Hyun-Duk;Lee, Jai-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2A
    • /
    • pp.174-185
    • /
    • 2010
  • A seamless handover between the 3G LTE and legacy 3G system is required for the smooth deployment of the 3G LTE system which is the next generation cellular network system. Especially on voice call handover, the service interruption time is very sensitive for user's satisfaction and therefore, a seamless voice call handover scheme is necessarily required. However, handover between the 3G LTE and the 3G CS system is hard to be achieved due to the lack of interface between two systems and the restriction of radio resource. In this paper, a new network entity called SCSE is proposed and inter-working between the 3G LTE and the 3G CS systems is enabled. Also contributed to the feature of the SCSE, the handover procedure is simplified and the service interruption time is minimized as a consequence. The evaluation result shows that the proposed SCSE scheme exclusively meets the service interruption time requirement which is smaller than 300 ms.

Serological Diagnosis of Human Sparganosis by means of micro-ELISA (효소면역측정법을 이용한 스파르가눔증의 혈청학적 진단)

  • Hyuck Kim;Suk-Il Kim;Seung-Yull Cho
    • Parasites, Hosts and Diseases
    • /
    • v.22 no.2
    • /
    • pp.223-228
    • /
    • 1984
  • Seven cases of surgically proven sparganosis were serologically tested by means of microELISA for their specific IgG antibody levels. For that purpose, crude saline extract of spargana from snake, Natrix tigrina lateralis was prepared and used as antigen. The sparganosis sera were also tested with Paragonimus and Cysticercus antigens to observe the cross reactivity. A total of 71 sera from normal control, ectopic and pulmonary paragonimiasis, clonorchiasis, cysticerCOSIS and Taenia saginata cases were also included. Except for one case of old calcified infection, all of 6 human sparganosis showed higher serum levels of specific IgG antibody when the differential point of positive reaction was set at the absorbance value of 0.25 (the sensitivity being 85.7%). In control and other helminthic infections, all except 3 cases of T. saginata infection showed negative reaction to sparganum antigen (the specificity being 90.7%). None of sparganosis cases showed cress reactivity to Paragonimus and Cysticercus antigens. Undiluted cerebrospinal l1uid also showed high levels of antibody when central nervous system was invaded. The serologic diagnosis by means of micro ELISA could be a useful tool in epidemiological study of human sparganosis in susceptible population, as well as in individual diagnosis.

  • PDF

Intracranial synthesis of specific IgG antibody in cerebrospinal fluid of neurocysticercosis patients (뇌유구낭미충증 환자의 뇌척수액내 특이 IgG항체의 기원)

  • 조승열;김석일
    • Parasites, Hosts and Diseases
    • /
    • v.26 no.1
    • /
    • pp.15-26
    • /
    • 1988
  • To determine the source of Cysticercus·specIfic IgG antibody in cerebrospinal fluid(CSF), paired samples of serum and CSF were collected from confirmed neurocysticercosis, other neurologic diseases and normal control. The antibody levels in serum and CSF were measured by ensyme-linked immunosorbent assay (ELISA). With the measurement of total protein, albumin and IgG concentration in serum and CSF, the contribution of IgG in CSF were calculated in transudation, exudation and intracranial synthesis using the formula of Tourtellotte and Ma (1978). Mean concentrations of total protein, albumin, IgG and proportional IgG levels in CSF by transudation, exudation and intracranial synthesis were elevated in neurocysticercosis. But only the intracranial synthesis of IgG showed a statistically significant correlation with the specific IgG antibody levels in CSF. In CSF from lateral ventricle in the 4th ventricular neurocysticercosis, the protein concentrations were normal and the specific antibody levels were negative. However, in consecutively secured lumbar CSF from the same patients, the former were increased and the latter were positive. These results indicated that, in neurocysticercosis, the specific IgG antibody in CSF was a local product of intracranial synthesis.

  • PDF

Detection of Giardia lamblia in River Water Samples Using PCR and RT-PCR (PCR 및 RT-PCR을 이용한 하천수 중 Giardia lamblia 검출)

  • Cho, Eun-Ju;Lee, Mok-Young;Byun, Seung-Heun;Han, Sun-Hee;Ahn, Seoung-Koo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.904-908
    • /
    • 2007
  • The protozoan pathogen Giardia lamblia has been major cause of waterborne enteric disease. In this study, we tried to identify G. lamlbia of human infectious species and to detect viable C. lamblia in river water samples including three sites of Han River mainstream and an its creek using PCR and RT-PCR technique. The PCR/RT-PCR methods were performed by using giardin primer based on the giardin gene targeting ventral disk of Giardia. Sensitivity testing in the DNA/RNA extraction and PCR/RT-PCR amplification steps showed that it was possible to detect a single cyst of G. lamblia and viable G. lamblia. The PCR/RT-PCR methods were compared with immunofluorescence(IF) assay by analyzing 48 samples collected from the mainstream water and the creek water. The mean concentration of the total cysts were 6.3 cysts/10 L(arithmetic mean, n = 48) and the positive detection rate were 62.5%(30/48). And the mean concentration of the cysts excluding empty cysts were 4.5 cysts/10 L and the positive detection rate were 52.1%(25/48). It resulted that 24 of 48 samples included Giardia lamblia by PCR assay and 10 of 48 samples included viable G. lamblia by RT-PCR assay. It resulted that the PCR/RT-PCR technique would be available to river water samples with low concentration of Giardia cysts. And it could support the Korean protozoan standard method, which provides useful information for species and viability.

SOI CMOS Miniaturized Tunable Bandpass Filter with Two Transmission zeros for High Power Application (고 출력 응용을 위한 2개의 전송영점을 가지는 최소화된 SOI CMOS 가변 대역 통과 여파기)

  • Im, Dokyung;Im, Donggu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.174-179
    • /
    • 2013
  • This paper presents a capacitor loaded tunable bandpass chip filter using multiple split ring resonators (MSRRs) with two transmission zeros. To obtain high selectivity and minimize the chip size, asymmetric feed lines are adopted to make a pair of transmission zeros located on each side of passband. Compared with conventional filters using cross-coupling or source-load coupling techniques, the proposed filter uses only two resonators to achieve high selectivity through a pair of transmission zeros. In order to optimize selectivity and sensitivity (insertion loss) of the filter, the effect of the position of asymmetric feed line on transmission zeros and insertion loss is analyzed. The SOI-CMOS switched capacitor composed of metal-insulator-metal (MIM) capacitor and stacked-FETs is loaded at outer rings of MSRRs to tune passband frequency and handle high power signal up to +30 dBm. By turning on or off the gate of the transistors, the passband frequency can be shifted from 4GH to 5GHz. The proposed on-chip filter is implemented in 0.18-${\mu}m$ SOI CMOS technology that makes it possible to integrate high-Q passive devices and stacked-FETs. The designed filter shows miniaturized size of only $4mm{\times}2mm$ (i.e., $0.177{\lambda}g{\times}0.088{\lambda}g$), where ${\lambda}g$ denotes the guided wave length of the $50{\Omega}$ microstrip line at center frequency. The measured insertion loss (S21)is about 5.1dB and 6.9dB at 5.4GHz and 4.5GHz, respectively. The designed filter shows out-of-band rejection greater than 20dB at 500MHz offset from center frequency.

Immunological properties of the 30 kDa antigen of Toxoplasma gondii (단클론 항체를 이용하여 정제한 톡소포자충 30 kDa 항원의 면역학적 특성)

  • Lee, Yeong-Hwa;No, Tae-Jin;Sin, Dae-Hwan
    • Parasites, Hosts and Diseases
    • /
    • v.35 no.1
    • /
    • pp.55-62
    • /
    • 1997
  • The molecular weight 30 kDa membrane protein of Toxoplusma Sondii (Toxoplasma 30 kDa) apparently conserved in most strains of T. gondii and sera of infected hosts. The present study aimed to elucidate Toxoplasmc 30 kDa as a useful diagnotic antigen for serodiagnisis of toxoplasmosis by ELISA and for induction of protective immunity. Murine spleen cells immunized with the membrane antigen of T. gondii were fused with mouse Sp2/0-Ag 14 myeloma cells. Out of 8 clones selected, five were IgG2b, the others belonged to IgG 1 and IgG2a. The 30 kDa antigen was distributed mainly on the surface membrane of tachyzoites by indirect fluorescence method. Murine peritoneal macrophages which were activated by 30 kDa antigen produced more amounts of NO2 compared with crude antigen-treated group, however there were no significant differences in toxoplamacidal activity between the two groups. Higher specificity of Toxoplosma 30 kDa antigen was recognized for serodiagnosis of toxoplasmosis than the crude antigen. From these results, ToxopLasmo 30 kDa antigen enhances the cytotoxic effect of macrophages as well as a more reliable means for the serodiagnosis of toxoplasmosis by ELISA. Key words: Toxoplosma gondii, 30 kDa antigen (p30), mouse, serodiagnosis, macrophage, cytotoxicity.

  • PDF