• Title/Summary/Keyword: Fz

Search Result 205, Processing Time 0.029 seconds

Reaction Characteristics of Thermochemical Methane Reforming on Ferrite-Based Metal Oxide Mediums (페라이트계 금속 산화물 매체 상에서 열화학 메탄 개질 반응 특성)

  • Cha, Kwang-Seo;Lee, Dong-Hee;Jo, Won-Jun;Lee, Young-Seak;Kim, Young-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.2
    • /
    • pp.140-150
    • /
    • 2007
  • Thermochemical 2-step methane reforming, involving the reduction of metal oxide with methane to produce syngas and the oxidation of the reduced metal oxide with water to produce pure hydrogen, was investigated on ferrite-based metal oxide mediums. The mediums, CoFZ, CuFZ, or MnFZ, were composed of the mixture of M(M=Co, Cu or Mn)-substituted ferrite as an active component and $ZrO_2$ as a binder, respectively. The WZ medium, composed of the mixture of $WO_3$ and $ZrO_2$, was also prepared to compare. With an addition of $ZrO_2$, the surface area of the mediums was slightly increased and the sintering of active components was greatly suppressed during the reduction. The higher reactivity of the reduced mediums for water splitting was confirmed by the temperature programmed reaction. From the results of the thermochemical 2-step methane reforming, the reactivity of $CH_4$ reduction and water splitting with ferrite-based metal oxide mediums was relatively higher than that with WZ, and the order of reactivity of the mediums was MnFZ>CoFZ>CuFZ>WZ.

Tourmaline Crystal Growth by FZ Method (FZ법에 의한 Tourmaline 단결정 성장)

  • 강승민;신재혁;한종원;최종건;오근호;박한수;문종수
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.3 no.1
    • /
    • pp.31-36
    • /
    • 1993
  • Na-Fe Tourmalene ($NaFe_3Al_6B_3Si_6O_{27}F_4$)single crystals were grown by FZ method. The Growth conditions are counter rotation 20~30rpm, growth rate 1~5mm/hr in the atmospheric environment. The transition elements as Fe(in this research), Mn, Co, etc, are exist in the theoretical fomulae so that dopants were not added. The feed rod was sintered between $1000^{\circ}C$ and $1l00^{\circ}C$, but at higher temperature, it was difficult to manufacture the feed rod because of evaporation of the elements such as F. As grown crystals had a black color and the length of 50~60mm, the diameter of 5~6mm. X-ray powder diffraction pattern indicated that the composition of the feed rod was right to the Tourmaline composition. By FT-IR spectra, the state of bonding of each element was charaterized.

  • PDF

Apatite Single Crystal Growth by FZ Method (FZ법에 의한 Apatite 단결정 성장)

  • 강승민;신재혁;한종원;최종건;전병식;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.3 no.2
    • /
    • pp.93-98
    • /
    • 1993
  • In the ternary system of $CaF_2-CaO-P_2O_5$. Apatite$(Ca_{10}(PO_4)_6F_2)$ single crystal having a congruent point was grown by FZ process. The atmospheric condition was kept by oxygen blowing. Adjusting the growth parameters of rotation rate, growth rate and gas amount, we tried to find the optimum growth condition. By partly substituting Ca as Co element, the absorption of infrared is increased and the color effect was observed. Using the Laue back reflection, XRD and FTIR analysis, the characterization of the crystal was carried out.

  • PDF

Accuracy and Reliability of Ground Reaction Force System and Effect of Force Platform Mounting and Environment (지면반력장비의 정밀성, 신뢰도와 장비설치.사용 환경의 영향)

  • Park, Young-Hoon;Youm, Chang-Hong;Sun, Sheng;Seo, Kook-Woong;Kim, Eui-Hwan;Kim, Tae-Whan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • Ground reaction force (GRF) measures are one of the most commonly used in biomechanical study. GRF system is very useful educational tool to explain and demonstrate the Newton's law of universal gravitation and laws of motion as well. However, accuracy, intra- and inter- force platform measures' consistency, reliability, noise, and the effect of platform mounting to GRF measures were not clearly viewed. The aim of this study was to examine the above. GRFs of a plastic dummy and two subjects' quiet upright standing were collected at four university laboratories eight force platforms. The types of platforms, analysis programs, and platform set-up were various. Three 100s-trials were conducted with sampling frequency of 100 Hz. First two trials' vertical component of GRFs, Fz, and CoP sway ranges of mid-60s-portion of 100s trials were analyzed by the paired t-tests and one-way ANOVA. Six of eight platforms' 1st and 2nd trial dummy Fz were statistically different (p<.05) and all platforms ICC were poor (<.28). Fz of the two platforms in every four laboratories were statistically different (p<.05). There were white noises and/or very distinctive noises at specific frequency ranges in all Fz measures. 5 Hz low-pass filtering made clear the Fz differences. CoP ranges of dummy were less than 0.5 cm and the best was 0.02 cm. This CoP range finding agrees with previous results suggests the importance of force platform mounting and A/D card resolution.

The Effect of Acupuncture at PC7(Daereung) on EEG in Normal Human Subject (대릉(大陵)(PC7) 침자가 뇌파에 미치는 영향)

  • Park, Cheol-Jin;Lee, Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.141-157
    • /
    • 2010
  • Objectives : The aim of this study is to examine the effects of acupuncture at PC7(Daereung) on normal human EEG using power spectral analysis. Methods : EEG power spectrum exhibits site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 subjects (16 males and 14 females; averaged age = 23.4 years) were engaged with thirty channel EEG study. Results : In $\alpha$(alpha) band, the power values at Fp1, Fp2, F7, F8 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased. In $\beta$(beta) band, the power values at Fp1, Fp2 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased and at F8, TCP2 channels(p<0.05) during non-acupoint treatment were increased. In $\theta$(theta) band, the power values at Fp1, Fp2, F7, F8 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased. In $\delta$(delta) band, the power values at Fp1, Fp2, F7, Fz, F8 channels (p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel (p<0.05) during non-acupoint treatment was significantly decreased. $\alpha/\beta$ values during PC7 treatment were decreased. $\beta/\theta$ values during PC7 treatment were decreased. Conclusion : These results suggest that acupuncture at PC7 induce the change on $\alpha$(alpha), $\beta$(beta), $\theta$ (theta), $\delta$(delta) wave values being decreased and and bothe $\alpha/\beta$ and $\beta/\theta$ values being decreased respectively. This is considered that acupuncture at PC7 affects the activity of cerebral cortex and endocrine system.

Design and fabrication of robot′s finger 3-axis force sensor for grasping an unknown object (미지물체를 잡기 위한 로봇 손가락의 3축 힘감지센서 설계 및 제작)

  • 김갑순
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.229-232
    • /
    • 2002
  • This paper describes the development of robot's finger 3-axis force sensor that detects the Fx, Fy, and Fz simultaneously fur stably grasping an unknown object. In order to safely grasp an unknown object using the robot's fingers, they should detect the force of gripping direction and the force of gravity direction, and perform the force control using the detected farces. The 3-axis force sensor that detects the Fx, Fy, and Fz simultaneously should be used for accurately detecting the weight of an unknown object of gravity direction. Thus, in this paper, robot's finger for stably grasping an unknown object is developed. And, the 3-axis farce sensor that detects the Fx, Fy, and Fz simultaneously fur constructing a robot's finger is newly modeled using several parallel-plate beams, and is fabricated. Also, it is calibrated, and evaluated.

  • PDF

Temperature Gradient Estimation of Floating Zone Furnace by Mean Lamellar Spacing Measurement in DS-processed TiAl Alloys

  • Jung, I.S.;Park, Jong-Moon;Wee, D.M.;Oh, Myung-Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.28 no.2
    • /
    • pp.82-86
    • /
    • 2015
  • In this study, the temperature gradient of a floating zone (FZ) apparatus, which is very difficult to directly measure, could be estimated by using the relationships between the lamellar spacing of directionally solidified TiAl alloys and the solidification rate, It was found that the calculated temperature gradient of the FZ apparatus was much higher, and almost ten times higher than that of a Bridgman type directional solidification apparatus.

CHANGES IN ADHESION OF STREPTOCOCCUS MUTANS TO NANOCOMPOSITE RESINS AFTER ACIDULATED PHOSPHATE FLUORIDE GEL APPLICATION (나노컴포지트에서 Acidulated Phosphate Fluoride 적용에 따른 Streptococcus mutans 부착량 변화)

  • Jung, Young-Jung;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.427-436
    • /
    • 2005
  • Topical application of APF gel can increase the surface roughness of resin composites and the roughened surfaces may allow increased bacterial accumulation and surface staining. Resin specimens of two proprietary resin composites, Filtek Z250(FZ) and Filtek Supreme Universal(FS), and experimental resin composites containing 0%, 3%, 6% nanofillers(E0, E3, E6) were fabricated and divided into two groups of the same number; APF treatment group and no treatment group. The amount of S. mutans adhered to specimens and the mean surface roughness(Ra) were measured. The results were as follows; 1. In no treatment group, the amount of S. mutans adhered to FS was the smallest. It was significantly different from those of FZ, E3, E6(p<0.05) although it was not significantly different from that of E0(p>0.05). 2. For all resin composites used, the amount of S. mutans adhesion in APF treatment group was significantly greater than that in no treatment group(p<0.05). 3. In APF treatment group, the amount of S. mutans adhesion was significantly different between materials(p<0.05), and increased in order of FS, FZ, E0, E3 and E6. 4. Difference of the surface roughness(Ra) between materials was not statistically significant in both no treatment group and APF treatment group(p>0.05)

  • PDF

Influence on the Ground Reaction Force Parameters According to Wearing Positions of Backpacks During Stair Ascending and Descending (계단 오르기와 내리기 시 가방착용 위치가 지면반력 파라미터에 미치는 영향)

  • Hyun, Seung-Hyun;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.85-94
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the influence on the ground reaction force parameters according to wearing positions of backpack for during stair ascending and descending. Methods : Participants selected as subject were consisted of young female(n=10) and performed stairs walks(ascending and descending) with 2 types of wearing position(front of trunk[FT], rear of trunk[RT]). Passive(Fz 1) and active(Fz 2) forces of the vertical GRF were determined from time function and frequency domain. Also shear forces(Fx, Fy 1, Fy 2), dynamic postural stability index(MLSI, APSI, VSI, DPSI), loading rate and center of pressure (${\Delta}COPx$, ${\Delta}COPy$, COP area) were calculated from time function and frequency domain. Results : Fx, Fy 1, Fy 2, and Fz 1 in GRF didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher forces than that of stair ascending. Particularly, Fz 2 of stair ascending showed higher forces than that of stair descending(p<.001), RT types showed higher than that of FT types(p<.05). MLSI, APSI, VSI, and DPSI of stair descending showed the increased stability index than that of stair ascending(p<.05), MLSI of RT types showed the decreased stability index than that of FT types(p<.05). Loading rate didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher loading rate than that of stair ascending(p<.001). Also, ${\Delta}COPx$ in stair descending showed the increased movement than that of stair ascending(p<.05). Conclusions : A backpack of 10 kg(10 kg(ratio of body weights $17.61{\pm}1.17%$) showed significantly change GRF parameters according to wearing positions during stair ascending and descending. If possible, we suggest that the dynamic stability, in case of stairs walking with a smaller weights can be further improved.

Simultaneous Determination of Residual Synthetic Antimicrobials in Animal Muscles by High Performance Liquid Chromatography (액체 크로마토그라피를 이용한 동물 근육조직 중의 합성항균제 동시 분석)

  • 정규생;채명식;김창동;김종배
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.1
    • /
    • pp.25-35
    • /
    • 1993
  • This study is conducted to deyelop more conyenient simultaneous determination method by HPLC for mixed antimicrobial agents (sulfamerazine; SMR, sulfamethazine; SMT, sulfamonomethoxine; SMMX, sulfadimethoxine; SDMX, sulfaquinoxaline; SQX, furazolidone; FZ, zolene; ZOL and ethopabate; EPB in muscles of boline, pork and chicken. The drugs were extracted by dichloromethane and water. The extract, after solyent eyaporation, was partitioned in hexane/water and water/dichloromethane. The dichloromethane layer was filtrated with anhydrous $Na_5S0_4\;in\;_3G_3$ glass filter and was eyaporated to dryness. The residue was dissoIYed in mobile phase. The test solution analyzed by HPLC. The chromatograpic conditions were as follows; Column-Spheri 5 RP-8($4.6{\times}220,\;5\;{\mu}$), Wayelength-270 nm, Mobile phase-acetonitrile: 0.005 M oxalic acid (22 : 78). The ayerage recoyeries of drugs from muscles of boline, pork and chicken spiked standard solution were approximately 74~99%, 73~99% and 75~96%, respectiyely. The limits of detection were 5 ppb for SMR, SMT, SMMX, SDMX and EPB, and 8 ppb for SQX, FZ and ZOL.

  • PDF