• Title/Summary/Keyword: Future Distribution System

Search Result 819, Processing Time 0.025 seconds

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

A Study on the Distribution Map Construction of Asbestos Buildings Owned by Seoul Using QGIS (QGIS를 활용한 서울시 소유 석면건축물 분포지도 제작에 관한 연구)

  • Lee, Jin Hyo;Bae, Il Sang;Ha, Kwang Tae;You, Seung Sung;Han, Kyu Mun;Eo, Soo Mi;Jung, Kweon;Lee, Jin Sook;Koo, Ja Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.528-533
    • /
    • 2016
  • One of ways for effectively maintaining asbestos buildings is to select asbestos buildings to be removed firstly by manufacturing and analyzing asbestos map of various topics. Thus, in this study we manufactured asbestos map of various topics for the effective management of asbestos buildings owned by Seoul using QGIS (Quantum Geographic Information System). To select asbestos buildings likely to cause asbestos scattering problem and exposure into the air, we comprehensively took into consideration various topics such as asbestos buildings density, asbestos-area ratio, asbestos buildings distribution considering the population, first removal object, risk assessment, elapsed year. As described in this study, using the GIS may be utilized as a method for selecting asbestos buildings to be removed firstly as well as distribution of asbestos buildings. In the future, it is necessary to make assessment criteria considering diversification of property value in GIS such as the characteristics of the living environment around the asbestos buildings. This is expected to be utilized to manage the vulnerable region to asbestos exposure.

A Study on the Efficient Management Plan of Water Distribution Reservoirs Facility Using 3D Geospatial Information (3D 공간정보를 이용한 배수지시설물의 효율적인 관리방안에 관한 연구)

  • Jung, In Hun;Ro, Young Suk;Choi, Yun Soo;Woo, Sang Yoon;Kim, Chong Mun
    • Spatial Information Research
    • /
    • v.20 no.6
    • /
    • pp.109-118
    • /
    • 2012
  • Recent increasement of metropolitan infrastructure due to rapid expansion and development of urban areas which caused complexity and diversification of management system demands higher cost and effort to manage and maintain the facilities. The reason why it requires continuous and systematic management by national government is that the infrastructure facilities takes important role as it is directly related to public's living. Thus this study suggests an efficient management plan for increasement of work efficiency, cost reduction, and time saving by introducing 3D geospatial information system for water distribution reservoirs which is managed by the Office of Waterworks Seoul Metropolitan Government. This study evaluates and quantifies the range of work improvement using the 3D GIS technology through carrying out a survey targeting people in charge of the Office of Waterworks Seoul Metropolitan Government and other 8 offices. From the result of the research, applying the 3D-GIS improves by 90.32%, 93.55%, and 91.61% in the area of work efficiency, cost reduction, and time saving respectively. Consequently, using 3D GIS in future management of infrastructure could be used as a way of producing base data which supports administrative decision making through statistical and case analysis based on continuous data management. Also it would contribute to improving work efficiency by improving management system through preventing data omission.

Re-chlorination facility design to cope with virus intrusion in water distribution system (상수도 관망 내 바이러스 유입 대응을 위한 재염소 시설 설계)

  • Kim, Beomjin;Lee, Seungyub
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.4
    • /
    • pp.277-287
    • /
    • 2024
  • Water distribution system (WDS) is exposed to various water quality incidents during its operation. This study utilized Quantitative Microbial Risk Assessment (QMRA) to analyze the risk associated with potential virus intrusion in WDSs. Additionally, the study determined the location and operation of rechlorination facilities to minimize potential risk. In addition, water quality resilience was calculated to confirm that the chlorine concentration maintains within the target range (0.1-1.0 mg/L) during normal operation. Hydraulic analysis was performed using EPANET, while EPANET-MSX was linked to simulate the reactions between viruses and chlorine. The proposed methodology was applied to the Bellingham network in the United States, where rechlorination facilities capable of injecting chlorine concentrations ranging from 0.5 mg/L to 1.0 mg/L were considered. Results indicated that without rechlorination facilities, the Average risk was 0.0154. However, installing rechlorination facilities and injecting chlorine at a concentration of 1.0 mg/L could reduce the Average risk to 39.1%. It was observed that excessive chlorine injection through rechlorination facilities reduced water quality resilience. Consequently, a rechlorination facility with a concentration of 0.5 mg/L was selected, resulting in a reduction of approximately 20% in average risk. This study provides insights for designing rechlorination facilities to enhance preparedness against potential virus ingress in the future.

Application of Low Pressure Fogging System for Commercial Tomato Greenhouse Cooling (상업용 토마토온실 냉방을 위한 저압분무식 포그시스템의 적용)

  • Lee, Hyun-Woo;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The objective of the present study is to identify the applicability of a low pressure fogging system for cooling commercial tomato greenhouse. In particular, the cooling system in this experiment utilizes low pressure spray nozzles which were developed in Korea recently. The experimental result that the temperature in fog-cooled greenhouse was lower than the non-cooled greenhouse showed the cooling effect by the low pressure fogging system. But because the relative humidity in fog-cooled greenhouse was comparatively low, the satisfactory cooling effect could be acquired by narrowing the space of fog nozzles and extending fogging time to supply more fog spray quantity. The variation of temperature distribution in fog-cooled greenhouse along timelag was insignificant during short time, but that was great during long period of day. This result showed the variation of temperature along timelag was slight by fog cooling but great by other factors like radiation, ventilation, air flow, etc. The advanced operation technology of fog system was required to reduce the variation of temperature along time lag. We plan to suggest the advanced installation and operation technology of low pressure fogging system for cooling commercial tomato greenhouse by further experiments in near future.

Model Predictive Control of Bidirectional AC-DC Converter for Energy Storage System

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.165-175
    • /
    • 2015
  • Energy storage system has been widely applied in power distribution sectors as well as in renewable energy sources to ensure uninterruptible power supply. This paper presents a model predictive algorithm to control a bidirectional AC-DC converter, which is used in an energy storage system for power transferring between the three-phase AC voltage supply and energy storage devices. This model predictive control (MPC) algorithm utilizes the discrete behavior of the converter and predicts the future variables of the system by defining cost functions for all possible switching states. Subsequently, the switching state that corresponds to the minimum cost function is selected for the next sampling period for firing the switches of the AC-DC converter. The proposed model predictive control scheme of the AC-DC converter allows bidirectional power flow with instantaneous mode change capability and fast dynamic response. The performance of the MPC controlled bidirectional AC-DC converter is simulated with MATLAB/Simulink(R) and further verified with 3.0kW experimental prototypes. Both the simulation and experimental results show that, the AC-DC converter is operated with unity power factor, acceptable THD (3.3% during rectifier mode and 3.5% during inverter mode) level of AC current and very low DC voltage ripple. Moreover, an efficiency comparison is performed between the proposed MPC and conventional VOC-based PWM controller of the bidirectional AC-DC converter which ensures the effectiveness of MPC controller.

THE ORBITAL THERMAL ANALYSIS OF HAUSAT-2 AND ITS THERMAL CONTROL SUBSYSTEM PRELIMINARY DESIGN (HAUSAT-2의 궤도 열해석과 열제어계의 예비설계)

  • Lee Mi-Hyeon;Kim Dong-Woon;Chang Young-Keun
    • Bulletin of the Korean Space Science Society
    • /
    • 2005.04a
    • /
    • pp.129-132
    • /
    • 2005
  • This paper describes BAUSAT-2 orbital thermal analysis and preliminary design of thermal control subsystem. To design thermal control subsystem of HAUSAT-2, we have considered active & passive thermal control method based on basic theory and themal equilibrium equation. Using this result, suitable thermal control method and material have been selected. We have designed thermal control subsystem based on analysis of HAUSAT-2's thermal environments on sun synchronous orbit with altitude 650km, inclination $98^{\circ}$ and thermal distribution and range expectation of each HAUSAT-2's surface. Thermal analysis consists of system level, box level and board level analysis. We have completed system level and box level analysis. Till now, board level analysis of main heat dissipation board in progress. Thermal control subsystem has designed according to thermal analysis result. This design is to maintain all of the HAUSAT-2 components within the allowable temperature limits. In future, STM

  • PDF

A study on Installation of Facility Monitoring System in Computer Room's (전산실 기반설비감시시스템 구축에 관한 연구)

  • Choi, Woo-hyoung;Kim, Chang-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.159-161
    • /
    • 2013
  • Surveillance system that can respond quickly in case of failure to detect various disorders that can occur for a temperature chamber, and fire extinguishing equipment, such as UPS, communication room, and computer room of enterprises and institutions operating in infrastructure, and to systematically study. Major telecommunications equipment and computational facilities to manage, operating in an environment of air conditioners work status, distribution panel and the UPS status and fault status, rapid notification system in case of fire is needed. By identifying the status and problems of disability surveillance on the periphery of the existing computer room's infrastructure management guidelines presented in the next future Conception and systematic surveillance system for staff to refer to when designing considerations associated with data center monitoring system the necessity of the various studies are presented.

  • PDF

Integrated Watershed Modeling Under Uncertainty (불확실성을 고려한 통합유역모델링)

  • Ham, Jong-Hwa;Yoon, Chun-Gyoung;Loucks, Daniel P.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.4
    • /
    • pp.13-22
    • /
    • 2007
  • The uncertainty in water quality model predictions is inevitably high due to natural stochasticity, model uncertainty, and parameter uncertainty. An integrated modeling system under uncertainty was described and demonstrated for use in watershed management and receiving-water quality prediction. A watershed model (HSPF), a receiving water quality model (WASP), and a wetland model (NPS-WET) were incorporated into an integrated modeling system (modified-BASINS) and applied to the Hwaseong Reservoir watershed. Reservoir water quality was predicted using the calibrated integrated modeling system, and the deterministic integrated modeling output was useful for estimating mean water quality given future watershed conditions and assessing the spatial distribution of pollutant loads. A Monte Carlo simulation was used to investigate the effect of various uncertainties on output prediction. Without pollution control measures in the watershed, the concentrations of total nitrogen (T-N) and total phosphorous (T-P) in the Hwaseong Reservoir, considering uncertainty, would be less than about 4.8 and 0.26 mg 4.8 and 0.26 mg $L^{-1}$, respectively, with 95% confidence. The effects of two watershed management practices, a wastewater treatment plant (WWTP) and a constructed wetland (WETLAND), were evaluated. The combined scenario (WWTP + WETLAND) was the most effective at improving reservoir water quality, bringing concentrations of T-N and T-P in the Hwaseong Reservoir to less than 3.54 and 0.15 mg ${L^{-1}$, 26.7 and 42.9% improvements, respectively, with 95% confidence. Overall, the Monte Carlo simulation in the integrated modeling system was practical for estimating uncertainty and reliable in water quality prediction. The approach described here may allow decisions to be made based on probability and level of risk, and its application is recommended.

Current CRM Adoption in Korean Apparel Industry (국내 의류업체의 CRM 도입현황)

  • Ko, Eun-Ju
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.1 s.149
    • /
    • pp.1-11
    • /
    • 2006
  • The purpose of this study was to analyze the current CRM situation in Korean apparel industry. Specifically, research purposes were 1) to examine the concepts and benefits of CRM, 2) to examine CRM strategies, 3) to analyze CRM system(i.e., customer relationship management service, customer segmentation criteria, DB management system), and 4) to analyze the potential problems and CRM adoption plan. The subjects for this research were thirty CRM managers in Korean apparel firms classified by the company type(woman's wear, man's wear, casual wear, children's wear, retailer) interviewed from December 2003 to March 1004. The results of this study were as follows: First, the concept of CRM represented the prime customer relationship, continuous consideration, and customer management system. The benefits of CRM reflected re-sales, improvement of profit share, and acquisition of customer's data base. Second, concerning the CRM strategies, most companies focused on persistent customer management through mileage program, membership cards and also implemented product strategies such as demand forecasting, customization based on customer data analysis. We also found that industry preferred to use pricing strategies, for example, segmentation of customer through discrepancies of price in which customers are provided by discount and gift voucher services. Regarding distribution strategy, channel diversification, localized service, and convenient delivery system were used. As promotion strategies, they chose celebrating customers' personal events and promoting cultural events and issuing coupons. Third, regarding CRM system, information service was the most frequently adopted, important and highly beneficial category. Also POS/web-POS, homepage were main sources of information. RFM is the mostly commonly used customer segmentation criteria. Fourth, potential problems in CRM adoption were lack of CRM knowledge and performance measurement of CRM. Future CRM adoption plan included CRM education and development of CRM performance measures.