• Title/Summary/Keyword: Fusion imaging

Search Result 229, Processing Time 0.032 seconds

Rapid Rigid Registration Method Between Intra-Operative 2D XA and Pre-operative 3D CTA Images (수술 중 촬영된 2D XA 영상과 수술 전 촬영된 3D CTA 영상의 고속 강체 정합 기법)

  • Park, Taeyong;Shin, Yongbin;Lim, Sunhye;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1454-1464
    • /
    • 2013
  • In this paper, we propose a rapid rigid registration method for the fusion visualization of intra-operative 2D XA and pre-operative 3D CTA images. In this paper, we propose a global movement estimation based on a trilateration for the fast and robust initial registration. In addition, the principal axis of each image is generated and aligned, and the bounding box of the vascular shape is compared for more accurate initial registration. For the fine registration, two images are registered where the distance between two vascular structures is minimized by selective distance measure. In the experiment, we evaluate a speed, accuracy and robustness using five patients' data by comparing the previous registration method. Our proposed method shows that two volumes can be registered at optimal location rapidly, and robustly comparing with the previous method.

Bone Cement Dislodgement : One of Complications Following Bone Cement Augmentation Procedures for Osteoporotic Spinal Fracture

  • Ha, Kee-Yong;Kim, Young-Hoon;Yoo, Sung-Rim;Molon, Jan Noel
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.5
    • /
    • pp.367-370
    • /
    • 2015
  • Bone cement augmentation procedures have been getting more position as a minimally invasive surgical option for osteoporotic spinal fractures. However, complications related to these procedures have been increasingly reported. We describe a case of bone cement dislodgement following cement augmentation procedure for osteoporotic spinal fracture by reviewing the patient's medical records, imaging results and related literatures. A 73-year-old woman suffering back and buttock pain following a fall from level ground was diagnosed as an osteoporotic fracture of the 11th thoracic spine. Percutaneous kyphoplasty was performed for this lesion. Six weeks later, the patient complained of a recurrence of back and buttock pain. Radiologic images revealed superior dislodgement of bone cement through the 11th thoracic superior endplate with destruction of the lower part of the 10th thoracic spine. Staged anterior and posterior fusion was performed. Two years postoperatively, the patient carries on with her daily living without any significant disability. Delayed bone cement dislodgement can occur as one of complications following bone cement augmentation procedure for osteoporotic spinal fracture. It might be related to the presence of intravertebral cleft, lack of interdigitation of bone cement with the surrounding trabeculae, and possible damage of endplate during ballooning procedure.

Idiopathic Hypertrophic Spinal Pachymeningitis : Report of Two Cases and Review of the Literature

  • Kim, Jee-Hee;Park, Young-Mok;Chin, Dong-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.392-395
    • /
    • 2011
  • Idiopathic hypertrophic spinal pachymeningitis (IHSP) is a rare inflammatory disease characterized by hypertrophic inflammation of the dura mater and various clinical courses that are from myelopathy. Although many associated diseases have been suggested, the etiology of IHSP is not well understood. The ideal treatment is controversial. In the first case, a 55-year-old woman presented back pain, progressive paraparesis, both leg numbness, and voiding difficulty. Initial magnetic resonance imaging (MRI) demonstrated an anterior epidural mass lesion involving from C6 to mid-thoracic spine area with low signal intensity on T1 and T2 weighted images. We performed decompressive laminectomy and lesional biopsy. After operation, she was subsequently treated with steroid and could walk unaided. In the second case, a 45-year-old woman presented with fever and quadriplegia after a spine fusion operation due to lumbar spinal stenosis and degenerative herniated lumbar disc. Initial MRI showed anterior and posterior epidural mass lesion from foramen magnum to C4 level. She underwent decompressive laminectomy and durotomy followed by steroid therapy. However, her conditions deteriorated gradually and medical complications occurred. In our cases, etiology was not found despite through investigations. Initial MRI showed dural thickening with mixed signal intensity on T1- and T2-weighted images. Pathologic examination revealed chronic nonspecific inflammation in both patients. Although one patient developed several complications, the other showed slow improvement of neurological symptoms with decompressive surgery and steroid therapy. In case of chronic compressive myelopathy due to the dural hypertrophic change, decompressive surgery such as laminectomy or laminoplasty may be helpful as well as postoperative steroid therapy.

Preliminary Application of Synthetic Computed Tomography Image Generation from Magnetic Resonance Image Using Deep-Learning in Breast Cancer Patients

  • Jeon, Wan;An, Hyun Joon;Kim, Jung-in;Park, Jong Min;Kim, Hyoungnyoun;Shin, Kyung Hwan;Chie, Eui Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.149-155
    • /
    • 2019
  • Background: Magnetic resonance (MR) image guided radiation therapy system, enables real time MR guided radiotherapy (RT) without additional radiation exposure to patients during treatment. However, MR image lacks electron density information required for dose calculation. Image fusion algorithm with deformable registration between MR and computed tomography (CT) was developed to solve this issue. However, delivered dose may be different due to volumetric changes during image registration process. In this respect, synthetic CT generated from the MR image would provide more accurate information required for the real time RT. Materials and Methods: We analyzed 1,209 MR images from 16 patients who underwent MR guided RT. Structures were divided into five tissue types, air, lung, fat, soft tissue and bone, according to the Hounsfield unit of deformed CT. Using the deep learning model (U-NET model), synthetic CT images were generated from the MR images acquired during RT. This synthetic CT images were compared to deformed CT generated using the deformable registration. Pixel-to-pixel match was conducted to compare the synthetic and deformed CT images. Results and Discussion: In two test image sets, average pixel match rate per section was more than 70% (67.9 to 80.3% and 60.1 to 79%; synthetic CT pixel/deformed planning CT pixel) and the average pixel match rate in the entire patient image set was 69.8%. Conclusion: The synthetic CT generated from the MR images were comparable to deformed CT, suggesting possible use for real time RT. Deep learning model may further improve match rate of synthetic CT with larger MR imaging data.

A case of McKusick-Kaufman syndrome

  • Son, Se-Hyung;Kim, Yoon-Joo;Kim, Eun-Sun;Kim, Ee-Kyung;Kim, Han-Suk;Kim, Beyong-Il;Choi, Jung-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.5
    • /
    • pp.219-223
    • /
    • 2011
  • McKusick-Kaufman syndrome (MKS) is an autosomal recessive multiple malformation syndrome characterized by hydrometrocolpos (HMC) and postaxial polydactyly (PAP). We report a case of a female child with MKS who was transferred to the neonatal intensive care unit of Seoul National University Children's Hospital on her 15th day of life for further evaluation and management of an abdominal cystic mass. She underwent abdominal sonography, magnetic resonance imaging, genitography and cystoscopy which confirmed HMC with a transverse vaginal septum. X-rays of the hand and foot showed bony fusion of the left third and fourth metacarpal bones, right fourth dysplastic metacarpal bone and phalanx, right PAP and hypoplastic left foot with left fourth and fifth dysplastic metatarsal bones. In addition, she had soft palate cleft, mild hydronephroses of both kidneys, hypoplastic right kidney with ectopic location and mild rotation, uterine didelphys with transverse vaginal septum and low-type imperforated anus. She was temporarily treated with ultrasound-guided transurethral aspiration of the HMC. Our patient with HMC and PAP was diagnosed with MKS because she has two typical abnormality of MKS and she has no definite complications of retinal disease, learning disability, obesity and renal failure that develop in Bardet-Biedl syndrome, but not in MKS until 33 months of age. Here, we describe a case of a Korean patient with MKS.

Development of a Vehicle Positioning Algorithm Using In-vehicle Sensors and Single Photo Resection and its Performance Evaluation (차량 내장 센서와 단영상 후방 교차법을 이용한 차량 위치 결정 알고리즘 개발 및 성능 평가)

  • Kim, Ho Jun;Lee, Im Pyeong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.2
    • /
    • pp.21-29
    • /
    • 2017
  • For the efficient and stable operation of autonomous vehicles or advanced driver assistance systems being actively studied nowadays, it is important to determine the positions of the vehicle accurately and economically. A satellite based navigation system is mainly used for positioning, but it has a limitation in signal blockage areas. To overcome this limitation, sensor fusion methods including additional sensors such as an inertial navigation system have been mainly proposed but the high sensor cost has been a problem. In this work, we develop a vehicle position estimation algorithm using in-vehicle sensors and a low-cost imaging sensor without any expensive additional sensor. We determine the vehicle positions using the velocity and yaw-rate of a car from the in-vehicle sensors and the position and attitude of the camera based on the single photo resection process. For the evaluation, we built a prototype system, acquired test data using the system, and estimated the trajectory. The proposed algorithm shows the accuracy of about 40% higher than an in-vehicle sensor only method.

Prevalence of dental anomalies among 7- to 35-year-old people in Hamadan, Iran in 2012-2013 as observed using panoramic radiographs

  • Shokri, Abbas;Poorolajal, Jalal;Khajeh, Samira;Faramarzi, Farhad;Kahnamoui, Hanieh Mogaver
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • Purpose: This study was performed to evaluate the prevalence of all types and subtypes of dental anomalies among 7- to 35-year-old patients by using panoramic radiographs. Materials and Methods: This cross-sectional study was conducted on 1649 people in Hamadan City, in 2012-2013. The prevalence of four types and 12 subtypes of dental anomalies was evaluated by two observers separately by using panoramic radiography. Dental anomalies were divided into four types: (a) shape (including fusion, taurodontism, and dens invagination); (b) number (including hypodontia, oligodontia, and hyperdontia); (c) structure (including amelogenesis imperfecta, dentinogenesis imperfecta, and dentin dysplasia); and (d) position (including displacement, impaction, and dilacerations). Results: The reliability between the two observers was 79.56% according to the Kappa statistics. The prevalence of dental anomalies diagnosed by panoramic radiographs was 29%. Anomalies of position and number were the most common types of abnormalities, and anomalies of shape and structure were the least in both genders. Anomalies of impaction (44.76%), dilacerations (21.11%), hypodontia (15.88%), taurodontism (9.29%), and hyperdontia (6.76%) were the most common subtypes of dental anomalies. The anomalies of shape and number were more common in the age groups of 7-12 years and 13-15 years, respectively, while the anomalies of structure and position were more common among the other age groups. Conclusion: Anomalies of tooth position were the most common type of dental anomalies, and structure anomalies were the least in this Iranian population. The frequency and type of dental anomalies vary within and between populations, confirming the role of racial factors in the prevalence of dental anomalies.

Application on the Convergence Technology for Culture Festival Promotion of Riverside Space (강변공간의 문화축제 조성을 위한 융복합 기술의 활용)

  • Yeon, Sang-ho;Lee, Young-wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.1 no.4
    • /
    • pp.79-86
    • /
    • 2015
  • Cheongpungho and riversides are located in the center of South Korea Jecheon Peninsula, cheongpungho be formed by a chungju hydroelectric dam built in 1984 has now been changed as a freshwater lake created by the center of the South Han River upstream over the past 30 years. Recent Jecheon-sigovernment is developing the entertainment and natural healing resorts for the future, this research is using remote sensing techniques and field survey plan in comparison to the feasibility study of the cultural festival of the area was conducted in geographic research and analysis very effective to conduct the natural environment and terrain analysis by aerial photography and remote sensing techniques that can be proven integration and cultural content, in the riverside area of future business creation and tourism resources of the facilities and events in the new brand through research It was envisioned. As a result, we propose a new direction for the future of cultural tourism to participate in the new state-of-the-art digital imaging technology to traditional cultural content in fusion experiments to be more multi-cultural festival is formed.

Whether Pinhole Scan or Single Photon Emission Computed Tomography (SPECT) in the Diagnosis of Bone and Joint Diseases (골격계진단에 있어서 핀홀스캔의 우월성)

  • Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1996
  • Since the publication of the first bone scintiscans in 1962 three decades have elapsed. The bone scan has made great strides during this period, becoming one of the most commonly used nuclear imaging tests. In spite of the progress, however, the specificity of bone scan has remained relatively low. As the result it is a common practice to seek additional information from radiograph, CT scan and MR image, which is euphemistically termed as "image fusion or co-location." The basic reason is the inapplicability of the classical piecemeal analysis to interpreting planar and SPECT bone scans. Such analysis has its base on the observation of elemental features of morphology, which include the size, shape, contour, location, topography and internal architecture. The physiochemical profile may well also be included. Understandably, however, the miniatured images of the planar bone scan cannot provide these features in acceptable detail and the same holds true even with SPECT Images which are but sliced views of the reconstructed planar scans. Fortunately pinhole scanning has the capacity to portray both the morphological and chemical profiles of bone and joint diseases in greater detail through true magnification. The magnitude of pinhole scan resolution is practically comparable to that of radiography as far as gross anatomy is concerned. Thus, we feel strongly that pinhole scanning is a potential breakthrough of the long-lamented low specificity of bone scan. This presentation will discuss the fun-damentals, advantages and disadvantages and the most recent advances of pinhole scanning. It high-lights the actual clinical applications of pinhole scanning in relation to the diagnosis of infective and inflammatory diseases of bone and joint.

  • PDF

AR monitoring technology for medical convergence (증강현실 모니터링 기술의 의료융합)

  • Lee, Kyung Sook;Lim, Wonbong;Moon, Young Lae
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.2
    • /
    • pp.119-124
    • /
    • 2018
  • The augmented reality(AR) technology enables to acquire various image information at the same time by combining virtual image information with the user's viewpoint. These AR technologies have been used to visualize patients' organs and tissues during surgery and diagnosis in the fields of Image-Guide Operation, Surgical Training, and Image Diagnosis by medical convergence, and provides the most effective surgical methods. In this paper, we study the technical features and application methods of each element technology for medical fusion of AR technology. In the AR technology for medical convergence, display, marker recognition and image synthesis interface technology is essential for efficient medical image. Such AR technology is considered to be a way to drastically improve current medical technology in the fields of image guide surgery, surgical education, and imaging diagnosis.