• Title/Summary/Keyword: Fundamental performance

Search Result 1,775, Processing Time 0.029 seconds

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.

Development and Application of Electrode for a New Secondary Aqueous Cell (새로운 수용성 2차 전지용 전극의 개발과 응용)

  • Hwang, Kum-Sho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.2
    • /
    • pp.165-170
    • /
    • 2005
  • Al-Zn alloy/$MnO_2$, seawater cell was considered as a primary aqueous cell with an average voltage range from 1.0 to 1.1V, and the electrolyte of seawater was uptaken into the cell. Eventually, the capacity of its usage will be used for long-term. However, the more use of this cell, the higher corrosion phenomenon of the electrode occurred. Due to its corrosion phenomenon, one main default has been observed with gradual decrease during a discharge process. In this research, a common-used active material for anode was $LiNiO_2$. An active material for cathode, $Zn_{X}FeS_2$ was synthesized in high temperature by uptaken a small amount of 1.3 wt% of ZnS into $FeS_2$, one of the transition-metal dichalcogenides in high temperature. Consequently, based on their usages shown above, this secondary aqueous lithium cell could be more developed. This cell was shown as remarkable charge/discharge performance during the charge/discharge processes. This cathode with active material was given a considerable efficiency of inserting $Li^+$ ions. Moreever, in accordance with the characteristic of the crystal structure for $Zn_{x}FeS_2$, a small amount of ZnS was added which made it possible to reduce prominently velocity of corrosion during the charge/discharge cycle. By applying those merits, Al-Zn alloy/$MnO_2$ seawater cell will be used as a fundamental data in order to transform into a secondary aqueous cell.

A GPS-less Framework for Localization and Coverage Maintenance in Wireless Sensor Networks

  • Mahjri, Imen;Dhraief, Amine;Belghith, Abdelfettah;Drira, Khalil;Mathkour, Hassan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.1
    • /
    • pp.96-116
    • /
    • 2016
  • Sensing coverage is a fundamental issue for Wireless Sensor Networks (WSNs). Several coverage configuration protocols have been developed; most of them presume the availability of precise knowledge about each node location via GPS receivers. However, equipping each sensor node with a GPS is very expensive in terms of both energy and cost. On the other hand, several GPS-less localization algorithms that aim at obtaining nodes locations with a low cost have been proposed. Although their deep correlation, sensing coverage and localization have long been treated separately. In this paper, we analyze, design and evaluate a novel integrated framework providing both localization and coverage guarantees for WSNs. We integrate the well-known Coverage Configuration Protocol CCP with an improved version of the localization algorithm AT-Dist. We enhanced the original specification of AT-Dist in order to guarantee the necessary localization accuracy required by CCP. In our proposed framework, a few number of nodes are assumed to know their exact positions and dynamically vary their transmission ranges. The remaining sensors positions are derived, as accurately as possible, using this little initial location information. All nodes positions (exact and derived) are then used as an input for the coverage module. Extensive simulation results show that, even with a very low anchor density, our proposal reaches the same performance and efficiency as the ideal CCP based on complete and precise knowledge of sensors coordinates.

Optimum topology design of geometrically nonlinear suspended domes using ECBO

  • Kaveh, A.;Rezaei, M.
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.667-694
    • /
    • 2015
  • The suspended dome system is a new structural form that has become popular in the construction of long-span roof structures. Suspended dome is a kind of new pre-stressed space grid structure that has complex mechanical characteristics. In this paper, an optimum topology design algorithm is performed using the enhanced colliding bodies optimization (ECBO) method. The length of the strut, the cable initial strain, the cross-sectional area of the cables and the cross-sectional size of steel elements are adopted as design variables and the minimum volume of each dome is taken as the objective function. The topology optimization on lamella dome is performed by considering the type of the joint connections to determine the optimum number of rings, the optimum number of joints in each ring, the optimum height of crown and tubular sections of these domes. A simple procedure is provided to determine the configuration of the dome. This procedure includes calculating the joint coordinates and steel elements and cables constructions. The design constraints are implemented according to the provision of LRFD-AISC (Load and Resistance Factor Design-American Institute of Steel Constitution). This paper explores the efficiency of lamella dome with pin-joint and rigid-joint connections and compares them to investigate the performance of these domes under wind (according to the ASCE 7-05), dead and snow loading conditions. Then, a suspended dome with pin-joint single-layer reticulated shell and a suspended dome with rigid-joint single-layer reticulated shell are discussed. Optimization is performed via ECBO algorithm to demonstrate the effectiveness and robustness of the ECBO in creating optimal design for suspended domes.

Nonlinear response of r.c. framed buildings retrofitted by different base-isolation systems under horizontal and vertical components of near-fault earthquakes

  • Mazza, Fabio;Mazza, Mirko;Vulcano, Alfonso
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.135-144
    • /
    • 2017
  • Near-fault ground motions are characterized by high values of the ratio between the peak of vertical and horizontal ground accelerations, which can significantly affect the nonlinear response of a base-isolated structure. To check the effectiveness of different base-isolation systems for retrofitting a r.c. framed structure located in a near-fault area, a numerical investigation is carried out analyzing the nonlinear dynamic response of the fixed-base and isolated structures. For this purpose, a six-storey r.c. framed building is supposed to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by current Italian code in a high-risk seismic zone. In particular, elastomeric (e.g., high-damping-laminated-rubber bearings, HDLRBs) and friction (e.g., steel-PTFE sliding bearings, SBs, or friction pendulum bearings, FPBs) isolators are considered, with reference to three cases of base isolation: HDLRBs acting alone (i.e., EBI structures); in-parallel combination of HDLRBs and SBs (i.e., EFBI structures); FPBs acting alone (i.e., FPBI structures). Different values of the stiffness ratio, defined as the ratio between the vertical and horizontal stiffnesses of the HDLRBs, sliding ratio, defined as the global sliding force divided by the maximum sliding force of the SBs, and in-plan distribution of friction coefficient for the FPs are investigated. The EBI, EFBI and FPBI base-isolation systems are designed assuming the same values of the fundamental vibration period and equivalent viscous damping ratio. The nonlinear dynamic analysis is carried out with reference to near-fault earthquakes, selected and scaled on the design hypotheses adopted for the test structures.

A Technique to Detect the Shadow Pixels of Moving Objects in the Images of a Video Camera (비디오 카메라 영상 내 동적 물체의 그림자 화소 검출 기법)

  • Park Su-Woo;Kim Jungdae;Do Yongtae
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1314-1321
    • /
    • 2005
  • In video surveillance and monitoring (VSAM), extracting foreground by detecting moving regions is the most fundamental step. The foreground extracted, however, includes not only objects in motion but also their shadows, which may cause errors in following video image processing steps. To remove the shadows, this paper presents a new technique to determine shadow pixels in the foreground image of a VSAM camera system. The proposed technique utilizes a fact that the effect of shadowing to each pixel is different defending on its brightness in a background image when determining shadow pixels unlike existing techniques where unified decision criteria are used to all pixels. Such an approach can easily accommodate local features in an image and hold consistent Performance even in changing environment. In real experiments, the proposed technique showed better results compared with an existing technique.

  • PDF

Two-phase Multicast in Wormhole-switched Bidirectional Banyan Networks (웜홀 스위칭하는 양방향 베니언 망에서의 두 단계 멀티캐스트)

  • Kwon, Wi-Nam;Kwon, Bo-Seob;Park, Jae-Hyung;Yun, Hyeon-Su
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.3
    • /
    • pp.255-263
    • /
    • 2000
  • A multistage interconnection network is a suitable class of interconnection architecture for constructing large-scale multicomputers. Broadcast and multicast communication are fundamental in supporting collective communication operations such as reduction and barrier synchronization. In this paper, we propose a new multicast technique in wormhole-switched bidirectional multistage banyan networks for constructing large-scale multicomputers. To efficiently support broadcast and multicast with simple additional hardware without deadlock, we propose a two-phase multicast algorithm which takes only two transmissions to perform a broadcast and a multicast to an arbitrary number of desired destinations. We encode a header as a cube and adopt the most upper input link first scheme with periodic priority rotation as arbitration mechanism on contented output links. We coalesce the desired destination addresses into multiple number of cubes. And then, we evaluate the performance of the proposed algorithm by simulation. The proposed two-phase multicast algorithm makes a significant improvement in terms of latency. It is noticeable that the two-phase algorithm keeps broadcast latency as efficient as the multicast latency of fanout 2^m where m is the minimum integer satisfying $2^m{\geq} {\sqrt{N}}$ ( N is a network size).

  • PDF

Ship Collision Avoidance Support Model in Close Quarters Situation( I ) (근접상황 선박충돌회피지원모델에 관한 연구( I ))

  • Yang Hyoung-Seon;Yea Byeong-Deok
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.827-832
    • /
    • 2004
  • Up to now a lot of the study on ship collision avoidance systems have proceeded actively. However the rate of ship collision accidents hasn't decreased yet. If there is collision risk in close quarters situation in spite of maneuvering ship for collision avoidance according to the system, only use of TCP A and DCP A as input factor for collision risk decision is not useful to avoiding collision action. For the recent 5 years by the analysis of first observation distance about approaching ship in domestic collision accidents, nearly $45\%$ of accidents is close first observation less than 2 miles. Therefore it is essential part for safety navigations to study for collision avoidance action in close encounter. In this paper, as a fundamental study of supporting collision avoidance maneuvering for navigators, we proposed ship collision avoidance support model in close quarters situation through analysis qf collision accidents to effectively get rid of the causes.

Investigation and Evaluation on Performance of Durability for Freeway Concrete Viaducts in Seoul Metropolitan Area (서울시내 위치한 콘크리트 고가차도의 내구성능 조사 및 평가)

  • Lee, Chang-Soo;Yoon, In-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.143-152
    • /
    • 2002
  • The objectives of this paper were to obtain the fundamental data to analyze the causes of deterioration of 39 freeway concrete viaducts in Seoul metropolitan area. To investigate the degree of concrete deterioration, carbonation depth, soluble chloride concentration in hardened concrete and half-cell potentials of reinforcement were measured. The number of structures which carbonation depth penetrates to reinforcement was 25% of total. The model of carbonation .ate was induced to 3.92 $\sqrt{t}$, which was 5% faster than 3.727 $\sqrt{t}$ assumed 60% water-cement ratio, R=1 in that of kishitani. After measuring chloride concentration in concrete, it was concluded that about 24% of all readings on samples from concrete exceed the critical content to minimize the risk of chloride-induced corrosion. About 31% of the freeway viaducts structures had a value lower than -350mV(vs. CSE), so it could conclude that the excessive chloride concentration was the major cause of reinforcement corrosion. Among the structures which measured half-cell potentials less than -350mV, about 50% exceeds the maximum acceptable limit of chloride concentration.

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.