• Title/Summary/Keyword: Fundamental Circuit

Search Result 199, Processing Time 0.025 seconds

A Design of 5.8 ㎓ Oscillator using the Novel Defected Ground Structure

  • Joung, Myoung-Sub;Park, Jun-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.2
    • /
    • pp.118-125
    • /
    • 2003
  • This paper presents a 5.8-㎓ oscillator that uses a novel defected ground structure(DGS), which is etched on the metallic ground plane. As the suggested defected ground structure is the structure for mounting an active device, it is the roles of a feedback loop inducing a negative resistance as well as a frequency-selective circuit. Applying the feedback loop between the drain and the gate of a FET device produces precise phase conversion in the feedback loop. The equivalent circuit parameters of the DGS are extracted by using a three-dimensional EM simulation ,md simple circuit analysis method. In order to demonstrate a new DGS oscillator, we designed the oscillator at 5.8-㎓. The experimental results show 4.17 ㏈m output power with over 22 % dc-to-RF power efficiency and - 85.8 ㏈c/Hz phase noise at 100 KHz offset from the fundamental carrier at 5.81 ㎓.

Open and Short Circuit Switches Fault Detection of Voltage Source Inverter Using Spectrogram

  • Ahmad, N.S.;Abdullah, A.R.;Bahari, N.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.190-199
    • /
    • 2014
  • In the last years, fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. The fault problem can cause equipment failure, data and economical losses. And the analyze system require to ensure fault problem and also rectify failures. The current errors on these faults are applied for identified type of faults. This paper presents technique to detection and identification faults in three-phase voltage source inverter (VSI) by using time-frequency distribution (TFD). TFD capable represent time frequency representation (TFR) in temporal and spectral information. Based on TFR, signal parameters are calculated such as instantaneous average current, instantaneous root mean square current, instantaneous fundamental root mean square current and, instantaneous total current waveform distortion. From on results, the detection of VSI faults could be determined based on characteristic of parameter estimation. And also concluded that the fault detection is capable of identifying the type of inverter fault and can reduce cost maintenance.

A Study on DC Offset Removal using Low-Pass Filter in AT Feeder System for Electric Railway (전기철도 AT급전계통에 Low-Pass Filter를 이용한 직류옵셋 제거에 관한 연구)

  • Lee, Hwan;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1108-1114
    • /
    • 2016
  • The cause of failure in the AT feeding system is divided into grounding, short-circuit of feeding circuit and internal faults of the railway substation. Since the fault current is very high, real-time current is detected and the failure must be immediately removed. In this paper, a new DC offset elimination filter that can remove component to decrease in the form of exponential function using low-pass filter was proposed in order to extract the fundamental wave from distorted fault current. In order to confirm the performance of the proposed filter method, AT feeder system was modelled by simulation tool and simulations were performed under various conditions such as fault location, fault resistance and fault voltage phase angle in case of trolley-rail short-circuit fault. When applying the proposed DC-offset removal method, it can be seen that the phase delay and gain error did not appear.

An Equivalent Circuit of the Piano and a Tonal Improvement Scheme in the Bass Registers (피아노의 등가회로와 저음부 음질의 개선방안)

  • Doo, S.J.;Sung, K.M.;Lee, C.K.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.39-47
    • /
    • 1987
  • It is well-known that analogizing a dynamic system to an equivalent circuit is a powerful tool on the analysis of the system. In this paper, an equivalent circuit of the piano has been constructed by the structural and acoustical analysis to visualize the sounding mechanism. Utilizing the mechanical reactance curve of the soundboard, a new method of reducing che inharmonicity in low frequency range has been built. With this method, by only choosing the proper excitation point on the soundboard, it will be possible to minimize the inharmonicity and thus to obtain mellow bass tone. It is shown that the missing fundamental in the lowest scale range results predominatly from the fact that the radiation impedance in such low frequencies is nearly pure reactive.

  • PDF

Finite Element Analysis of the Transient Characteristics of a Superconducting A.C. Generator (유한요소법에 의한 초전도교류 발전기의 과도 특성 해석)

  • 한성진;배동진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.1
    • /
    • pp.24-30
    • /
    • 1991
  • This paper deals with the analysis of the transient characteristics of a superconducting a.c. generator(SCG) using Finite Element Method. Since the magnetic field induced by the field current and the armature currents are not sinusoidally distributed in a generator, the conventional equivalent circuit method, in general, uses the fundamental component only and is done in frequency domain. But the finite element analysis makes it possible to analyze the transient magnetic field distribution and the electrical characteristics of the double shields of SCG in time domain.

  • PDF

Super-High Speed Photo detection through Frequency Conversion for Microwave on Optical Network

  • Choi, Young-Kyu;Shin, Sang-Yeol
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.439-443
    • /
    • 2008
  • It is shown that even if the modulating frequency of the light is too high for direct detection the signal can be extracted by frequency conversion at the same time as the detection by means of the nonlinearity of the APD. When this frequency conversion detection is applied to an optical receiver, the detection bandwidth can be increased while the configuration of the optical detection circuit and the signal processing in the subsequent stages are simplified. A fundamental analysis is carried out with an APD which is confirmed experimentally.

SART(SEARCH AND RESCUE RADAR TRANSPONDER)의 개발에 관한연구

  • 임종근
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1995.04a
    • /
    • pp.93-108
    • /
    • 1995
  • SART(Search and Rescue Radar Transponder) is a radar transponder capable of operating in the 9GHz band which is one element of GMDSS. the fundamental function of the SART is to indicate its position. Thus it is so much available to assist SAR operation when an emergency and casualty occur at any sea area, In the thesis we designed manufactured each part of circuit to develop the advanced SART and configured to test the characteristics in many ways, As the results of detailed things we confirmed that the developed SART could be high possibility of production.

A Transmission Loss Allocation with Power Contribution Method In the Open Access Environment (송전망 기방 환경원서의 전력기여 해석법을 이용한 송전손실 분배)

  • Song, Hwa-Chang;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.62-64
    • /
    • 2001
  • This paper presents a new loss allocation scheme using power contribution method Power contribution is to find how much power at each generating/1oad bus is contributed to individual load/generating bus. In this paper power contribution is calculated using fundamental circuit theory. In numerical simulation, an illustrative example applying the proposed scheme to 6-bus test system is shown.

  • PDF

Analysis of Multi Level Current Source GTO Inverter for Induction Motor Drives

  • Arase, Takayuki;Matususe, Kouki
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.535-540
    • /
    • 1998
  • This paper discusses a triple stage current source GTO inverter system for high power motor drives. The energy rebound circuit of the triple stage inverter not only controls the spike voltage of the GTO inverter but also facilitates PWM control of the thyristor rectifier operated at unity fundamental input power factor. Based on Pspice simulation and experiments, the principles and PWM pulse pattern for removing specific lower harmonics in the inverter's output current are discussed in detail.

  • PDF

Short-Circuit Calculation Using Tow-Port Network (4단자망을 아용한 고장계산에 관한 연구)

  • 김주용;이재용;백영식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.533-542
    • /
    • 1994
  • This paper presents the new algorithm for fault analysis and this algorithm obtains requisite term for fault analysis by the two-port network technique. Therefore, the fault calculation time is composed of only few fundamental arithmetic calculation. The graphic user environment for fault analysis is implemented in mouse-oriented user interface with window and pull-down menu. The result of the algorithm proved to be identical with the sample system in Ref.[8]. this package can be a useful tool for fault analysis.