• 제목/요약/키워드: Functional Prediction

검색결과 321건 처리시간 0.031초

Identification of relevant differential genes to the divergent development of pectoral muscle in ducks by transcriptomic analysis

  • Fan Li;Zongliang He;Yinglin Lu;Jing Zhou;Heng Cao;Xingyu Zhang;Hongjie Ji;Kunpeng Lv;Debing Yu;Minli Yu
    • Animal Bioscience
    • /
    • 제37권8호
    • /
    • pp.1345-1354
    • /
    • 2024
  • Objective: The objective of this study was to identify candidate genes that play important roles in skeletal muscle development in ducks. Methods: In this study, we investigated the transcriptional sequencing of embryonic pectoral muscles from two specialized lines: Liancheng white ducks (female) and Cherry valley ducks (male) hybrid Line A (LCA) and Line C (LCC) ducks. In addition, prediction of target genes for the differentially expressed mRNAs was conducted and the enriched gene ontology (GO) terms and Kyoto encyclopedia of genes and genomes signaling pathways were further analyzed. Finally, a protein-to-protein interaction network was analyzed by using the target genes to gain insights into their potential functional association. Results: A total of 1,428 differentially expressed genes (DEGs) with 762 being up-regulated genes and 666 being down-regulated genes in pectoral muscle of LCA and LCC ducks identified by RNA-seq (p<0.05). Meanwhile, 23 GO terms in the down-regulated genes and 75 GO terms in up-regulated genes were significantly enriched (p<0.05). Furthermore, the top 5 most enriched pathways were ECM-receptor interaction, fatty acid degradation, pyruvate degradation, PPAR signaling pathway, and glycolysis/gluconeogenesis. Finally, the candidate genes including integrin b3 (Itgb3), pyruvate kinase M1/2 (Pkm), insulin-like growth factor 1 (Igf1), glucose-6-phosphate isomerase (Gpi), GABA type A receptor-associated protein-like 1 (Gabarapl1), and thyroid hormone receptor beta (Thrb) showed the most expression difference, and then were selected to verification by quantitative real-time polymerase chain reaction (qRT-PCR). The result of qRT-PCR was consistent with that of transcriptome sequencing. Conclusion: This study provided information of molecular mechanisms underlying the developmental differences in skeletal muscles between specialized duck lines.

Identification and functional prediction of long non-coding RNAs related to oxidative stress in the jejunum of piglets

  • Jinbao Li;Jianmin Zhang;Xinlin Jin;Shiyin Li;Yingbin Du;Yongqing Zeng;Jin Wang;Wei Chen
    • Animal Bioscience
    • /
    • 제37권2호
    • /
    • pp.193-202
    • /
    • 2024
  • Objective: Oxidative stress (OS) is a pathological process arising from the excessive production of free radicals in the body. It has the potential to alter animal gene expression and cause damage to the jejunum. However, there have been few reports of changes in the expression of long noncoding RNAs (lncRNAs) in the jejunum in piglets under OS. The purpose of this research was to examine how lncRNAs in piglet jejunum change under OS. Methods: The abdominal cavities of piglets were injected with diquat (DQ) to produce OS. Raw reads were downloaded from the SRA database. RNA-seq was utilized to study the expression of lncRNAs in piglets under OS. Additionally, six randomly selected lncRNAs were verified using quantitative real-time polymerase chain reaction (qRT-PCR) to examine the mechanism of oxidative damage. Results: A total of 79 lncRNAs were differentially expressed (DE) in the treatment group compared to the negative control group. The target genes of DE lncRNAs were enriched in gene ontology (GO) terms and Kyoto encyclopedia of genes and genomes (KEGG) signaling pathways. Chemical carcinogenesis-reactive oxygen species, the Foxo signaling pathway, colorectal cancer, and the AMPK signaling pathway were all linked to OS. Conclusion: Our results demonstrated that DQ-induced OS causes differential expression of lncRNAs, laying the groundwork for future research into the processes involved in the jejunum's response to OS.

Effects of diets for three growing stages by rumen inocula donors on in vitro rumen fermentation and microbiome

  • Ryukseok Kang;Huseong Lee;Hyeonsu Seon;Cheolju Park;Jaeyong Song;Joong Kook Park;Yong Kwan Kim;Minseok Kim;Tansol Park
    • Journal of Animal Science and Technology
    • /
    • 제66권3호
    • /
    • pp.523-542
    • /
    • 2024
  • Hanwoo and Jeju Black cattle (Jeju Black) are native breeds of Korean cattle. Jeju Black cattle are recognized as natural monuments and are known to exhibit slower growth rates compared to Hanwoo. While several studies have analyzed the genetic characteristics of these cattle, there has been limited research on the differences in their microbiome. In this study, rumen fluid was obtained from three Hanwoo steers and three Jeju Black steers, and three different diets (total mixed rations [TMRs] for growing, early fattening, and late fattening periods) were used as substrates for in vitro fermentation. The in vitro incubation was conducted for 3 h and 24 h following a 2 × 3 factorial arrangement. After both incubation periods, fermentation characteristics were analyzed, and ruminal microbiome analysis was performed using 16S rRNA gene sequencing, employing both QIIME2 and PICRUSt2. The results revealed significant differences in the ruminal microbiota due to the inoculum effect. At the phylum level, Patescibacteria and Synergistota were found to be enriched in the Jeju Black inoculum-treated group. Additionally, using different inocula also affected the relative abundance of major taxa, including Ruminococcus, Pseudoramibacter, Ruminococcaceae CAG-352, and the [Eubacterium] ruminantium group. These microbial differences induced by the inoculum may have originated from varying levels of domestication between the two subspecies of donor animals, which mainly influenced the fermentation and microbiome features in the early incubation stages, although this was only partially offset afterward. Furthermore, predicted commission numbers of microbial enzymes, some of which are involved in the biosynthesis of secondary metabolites, fatty acids, and alpha amylase, differed based on the inoculum effect. However, these differences may account for only a small proportion of the overall metabolic pathway. Conversely, diets were found to affect protein biosynthesis and its related metabolism, which showed differential abundance in the growing diet and were potentially linked to the growth-promoting effects in beef cattle during the growing period. In conclusion, this study demonstrated that using different inocula significantly affected in vitro fermentation characteristics and microbiome features, mainly in the early stages of incubation, with some effects persisting up to 24 h of incubation.

18~34 남성의 최대산소 섭취량 추정 (Prediction of Maximal Oxygen Uptake Ages 18~34 Years)

  • 전유정;임재형;이병근;김창환;김병완
    • 한국체육학회지인문사회과학편
    • /
    • 제51권3호
    • /
    • pp.373-382
    • /
    • 2012
  • 본 연구의 목적은 신체변인과 최대하 대사반응을 이용하여 최대산소섭취량(VO2max)을 간편하고 정확하게 추정하는 데 있다. 18~34세 남성 250명을 대상으로 추정집단(n=179)과 타당도 검증집단(n=71)으로 나누어 최대 운동부하검사를 실시하였으며 3분인 1단계와 6분인 2단계 종료 시점의 대사반응을 측정하였다. 추정 집단을 대상으로 단계선택법(stepwise method)으로 다중회귀분석 (multiple regression analysis)을 실시하였다. 단계별분석법으로 분석한 모형 1의 추정변인은 체중, 6분HR, 6분VO2이고 R은 0.64(p<.01)이었으며 SEE와 CV는 각각 4.74, 11.7%로 나타났고(p<.01), 추정식은 VO2max(ml/kg/min)= 72.256-0.340(Weight)-0.220(6분HR)+0.013(6분VO2)이며 다중공선성이 나타나지 않았다. 모형 2의 추정변인은 체중, 6분HR, 6분VO2, 6분VCO2이고 R은 0.66(p<.01)이었으며 SEE와 CV는 각각 4.59, 11.3%로 나타났고(p<.01), 추정식은 VO2max(ml/kg/min)= 68.699-0.277(Weight) -0.206(6분HR)+0.020(6분VO2)-0.009(6분VCO2)이며, 역시 다중공선성이 나타나지 않았다. 모형 1과 비교했을 때 모형 2는 상관이 더 높지만 다중공선성 측면에서는 다소 불리하게 나타났다. 모형 1과 모형 2를 교차타당도 검증집단에 적용했을 때, 측정된 VO2max와 추정된 VO2Max 간에 유의한 상관관계가 나타났다(R=0.53, 0.56, P<.001). 타당도 검증을 통해 유용성과 간편성을 고려하면, 본 연구에서 얻은 신체변인 및 최대하 대사반응을 이용한 추정모형들이 모두 사용가능하나 모형 2가 정확도 측면에서 다소 유리하다.

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

급성심근경색증의 일차적 관동맥성형술 후 조기 Tl-201 재분포영상을 이용한 구조심근 예측 (Prediction of Salvaged Myocardium in Patients with Acute Myocardial Infarction after Primary Percutaneous Coronary Angioplasty using early Thallium-201 Redistribution Myocardial Perfusion Imaging)

  • 최준영;양유정;최승진;여정석;박성욱;송재관;문대혁
    • 대한핵의학회지
    • /
    • 제37권4호
    • /
    • pp.219-228
    • /
    • 2003
  • 목적: 심근경색증 후 재관류술에 의해 구조된 심근의 범위는 중요한 예후 인자중의 하나이다. 급성심근경색증의 일차적 관동맥성형술 후 조기 Tl-201 재분포영상이 구조심근과 심근벽운동 호전을 예측할 수 있는지 알아보았다. 대상 및 방법: 흉통 발생 $5.2{\pm}2.8$시간에 급성심근경색증으로 일차적 관동맥성형술을 시행한 36명을 대상으로 관동맥성형술 후 $5.8{\pm}2.1$일에 디피리다몰 부하 -4 시간 재분포 Tl-201 SPECT 영상을 얻었다. Tl-201 재분포 영상은 좌심실을 16분절로 나누고, 각 분절의 섭취를 5등급으로 평가하였다. 심초음파는 내원 당시, 경색 후 7일, 30일, 7개월에 시행하였고, 구조심근 분절은 내원 당시 심초음파상 벽 운동 이상이 있으면서 30일 또는 7개월 심초음파에서 벽 운동이 호전된 분절로 정의하였다. 결과: 내원 당시 212분절에서 벽운동 이상을 보였다(저운동 41분절, 무운동 171분절). 이중 1개월에는 78분절(36.8%)에서, 7개월에는 97분절(45.8%)에서 벽 운동이 호전되어 구조심근으로 판정하였다. 구조심근을 찾는 Tl-201 재분포 영상의 수신자판 단특성곡선면적은 1개월에 대해서는 $0.79{\pm}0.03$, 7개월에 대해서는 $0.83{\pm}0.03$이었다. Tl-201 섭취 40%를 경계로 정할 때 재분포 영상의 구조심근을 찾는 예민도, 특이도는 1개월에서는 84.6%(66/68), 55.2%(74/134), 7개월에서는 87.6%(85/97), 64.3%(74/115)였다. 재분포영상에서 Tl-201의 섭취정도와 벽 운동의 호전될 확률은 서로 비례하는 경향을 나타내었다. 결론: 급성심근경색증의 일차적 관동맥성형술 후 10일 이내에 시행한 조기 Tl-201 재분포영상은 구조심근과 심근벽운동 호전 예측 판정에 높은 예민도로 유용하게 사용될 수 있는 검사이다.EX>$100{\mu}M$)는 각각 11.9배와 6.8배, K562(Adr) 세포에서($50{\mu}M$)는 각각 14.3배와 8배, K562(Vcr) 세포에서($10{\mu}M$)는 각각 7배와 5.7배 증가하였다. Cyclosporin A에 의한 MIBI와 tetrofosmin의 섭취율(30분)을 기저치(30분)와 비교해 본 결과 HCT15/CL02세포에서($50{\mu}M$)는 각각 10배와 2.4배, K562(Adr)세포에서($50{\mu}M$)는 각각 44배와 13배, K562(Vcr)세포에서($10{\mu}M$)는 각각 18.8배와 11.8배 증가하여, MIBI의 섭취율이 tetrofosmin보다 1.2배에서 4배정도 높게 나타났다. 결론: 이러한 결과로 보아 MIBI와 tetrofosmin은 다약제내성의 발현을 평가할 수 있는 방사성의약품으로 판단되며, 다약제내성 극복제의 효능평가에는 MIBI가 tetrofosmin보다 더 우수할 것으로 사료되나, 세포추에 따른 차이가 있을 수 있으므로 보다 많은 세포주에서의 추가적인 연구가 필요할 것이다.여 후 구한 MPD는 평균 $13.3{\pm}1.9GBq\;(9.7{\sim}16GBq)$ 이였고, 치료용량 방사성옥소 투여 후 구한 MPD는 평균 $13.8{\pm}2.1GBq(10.4{\sim}16.3GBq)$로 유의한 차이가 얻었으며 (p=0.20), 두 수치간에는 유의한 상관 관계가 있었다(r=0.8, p<0.0001). 7명의 환자에서 말초혈액림프구 중기염색체 분석법으로 MPD를 측정하였는데 혈액의 피폭선량은 $1.78{\pm}0.03Gy$였으며, 같은 환자에서 혈중 방사능소실곡선으로부터 구한 피폭선량은 $1.54{\pm}0.03Gy$로 유의하게 낮았으나 (p=0.01), 두

근적외 분광분석법을 이용한 국내 유통 식품 함유 탄수화물, 단백질 및 지방의 정량 분석 (Quantitative Analysis of Carbohydrate, Protein, and Oil Contents of Korean Foods Using Near-Infrared Reflectance Spectroscopy)

  • 송이슬;김영학;김기쁨;안경근;황영선;강인규;윤성원;이준수;신기용;이우영;조영숙;정명근
    • 한국식품영양과학회지
    • /
    • 제43권3호
    • /
    • pp.425-430
    • /
    • 2014
  • 식품의 3대 영양소인 탄수화물, 단백질 및 지방의 일반적인 분석 방법은 Kjeldahl 및 Soxhlet 시험법과 같은 기존의 화학 분석 방법으로 분석하였다. 그러나 이러한 분석 방법은 시료의 전처리 과정이 필요하고 많은 비용과 분석 시간이 소모되며 복잡한 추출과정을 거친다는 단점이 있다. 따라서 본 연구에서는 국내 유통 식품 및 농산물 자원에 함유된 탄수화물, 단백질 및 지방의 함량을 근적외 분광분석법(near-infrared reflectance spectroscopy, NIRS)으로 신속하고 정확하게 동시에 측정할 수 있는 방법을 검토하였다. 분석시료는 517종의 다양한 식품 시료를 예측모델 개발용(calibration set) 412종과 예견치 분석용(validation set) 162종으로 구분하여 사용하였다. 기존의 화학 분석 방법에 의해 측정된 성분들의 분석 결과와 근적외 스펙트럼 데이터간의 상관관계를 조사하여 각 성분별 예측모델을 검토하였으며, 변형부분최소자승법(MPLS) 및 다양한 수처리와 산란보정을 이용한 결과, 탄수화물, 단백질 및 지방의 산란방식은 각각 weighted MSC, standard MSC 및 SNV only로 수처리는 각각 1차 미분(1st derivative, 4 nm gap, 5 points smoothing, 1 point second smoothing), 2차 미분(2, 5, 5, 3) 및 1차 미분(1, 1, 1, 1)을 적용하여 예측모델을 검토한 결과 $R^2$값이 0.971, 0.974 및 0.937로 높고 SEC값은 4.066, 1.080 및 1.890으로 낮은 최적의 예측모델을 개발하였다. 세 성분의 최적 예측모델에 의한 상관도와 잔차 히스토그램을 검토한 결과 세 성분 모두 근적외 분광분석법 예측모델로 적합함을 확인할 수 있었으며, 최적의 예측모델을 미지의 식품 시료 162종에 적용한 결과, 탄수화물, 단백질 및 지방의 $r^2$(SEP)값은 0.987(2.515), 0.970(1.144) 및 0.947(1.370)로 $r^2$값은 높으며 SEP값은 낮은 양호한 양상을 나타내었다. 그러나 지방의 결정계수($R^2$, $r^2$)값은 탄수화물, 단백질에 비해 다소 낮은 양상을 나타내므로 추후 식품 검체에 적용 시 탄수화물 및 단백질 성분에 비해 예측결과의 정확성이 다소 낮을 수 있다고 판단되어진다. 이상의 결과에서 전처리 단계에서 복잡한 추출과정, 많은 비용소모, 분석시간 및 고도의 분석기술을 요하는 기존 습식 화학분석 방법의 단점을 보완하고자 검토되었던 근적외 분광분석법은 다량의 식품분석 시료를 분석하기에는 매우 효율적이라고 생각되며, 이런 점들을 고려해 보면 근적외 분광분석 예측모델들은 추후에 미지 식품시료에 함유된 탄수화물, 단백질 및 지방의 기존 분석법을 대체하여 편리하고 빠르게 함량을 예측 가능할 것으로 판단된다.

약리 유전학적 방법을 이용한 항우울제 치료반응성의 예측 (The Use of Pharmacogenomic Method for the Prediction of Antidepressant Responsiveness)

  • 김도관;임신원
    • 생물정신의학
    • /
    • 제9권1호
    • /
    • pp.25-33
    • /
    • 2002
  • 우울증 환자들에게 항우울제를 처방하는 임상의들이 흔히 겪게 되는 두 가지 어려움은 약물의 치료 반응 유무를 판단하기 위하여 처음 약물을 투여한 후 4~6주 이상을 기다려야 하는 것과 어떤 종류의 항우울제라도 처음 4~6주 이후에도 반응을 보이지 않는 환자들이 30~40% 이상이 된다는 것이다. 이와 같은 어려움을 극복하기 위해서는 환자 개개인의 항우울제에 대한 반응성을 미리 예측하는 것이 필요하다. 이 논문에서는 연구자들의 과거 실험들과 이미 발표된 연구들을 중심으로 하여 항우울제에 대한 치료 반응성을 예측하는데 약리유전학적 방법을 이용한 현재까지의 연구들과 연구 결과를 해석 할때 고려해야 할 사항을 살펴보고자 한다. 세로토닌 수송체(serotonin transporter, 5-HTT)는 항우울제가 신경세포에 작용하는 주요 작용부위 중 하나이다. 최근의 연구들에 의하면 5-HTT 유전자 promoter 부위의 기능적인 다형성(5-HTT linked polymorphism repetitive element in promoter region, 5-HTTLPR)이 항우울제에 대한 치료 반응성과 관련이 있는 것으로 알려져 있으며, 5-HTTLPR 유전형의 분포빈도는 인종들 간에서 차이가 있는 것으로 알려져 있다. 연구자들은 최근의 실험을 통하여 5-HTTLPR 유전형들의 endophenotype을 혈소판 막에 분포하는 5-HTT의 약동학적 특성으로 측정할 수 있음을 발견하였다. 흥미로운 사실은 5-HTTLPR 유전형의 분포가 인종적으로 다른 양상으로 나타났듯이, 그 endophenotype인 혈소판막의 5-HTT의 약동학적 특성 역시 전혀 반대되는 양상으로 나타났다. 하지만 이 endophenotype의 특성만으로 항우울제의 치료반응을 예측하는 것은 아직까지 한계가 있으며, 향후 이러한 과제를 해결하기 위한 방법중 약리유전학적 방법을 사용할 수 있음을 제안하였다. 예비적으로 시행한 실험을 통하여 연구자들은 세로토닌 수송체의 구조와 특징이 비슷한 생체아민 수송체들의 유전자 다형성들 간에 유의한 상관관계가 있음을 발견하였으며, 이들 유의한 상관관계가 있는 유전자형을 연합하여 조합할 때 세로토닌 수송체의 유전형만의 기여도보다도 항우울제에 대한 반응 예측도의 odds ratio가 유의하게 상승함을 발견하였다. 이러한 연구 결과들은 임상의가 항우울제를 처방 할 때에 환자들의 유전적 그리고 인종적인 배경을 고려하여 개별화된 전략을 사용하여야 한다는 가설을 뒷받침한다. 앞으로 항우울제의 작용기전과 그 대사과정에 관여하는 유전자들들 중심으로 유전자 간의 상호 작용을 밝히고 그 표현형이 약물의 치료 반응도에 미치는 기여도를 평가하는 작업들은 항우울제의 치료 반응과 그 부작용을 미리 예측할 수 있는 평가 도구를 개발할 수 있는 가장 최선의 길이 될 수 있을 것이다.

  • PDF

관절염 환자의 운동행위 예측모형 (Pender의 재개정된 건강증진 모형에 의한) (Prediction Model of Exercise Behaviors in Patients with Arthritis (by Pender's revised Health Promotion Model))

  • 임난영;서길희
    • 근관절건강학회지
    • /
    • 제8권1호
    • /
    • pp.122-140
    • /
    • 2001
  • The aims of this study were to understand and to predict the determinent factors affecting the exercise behaviors and physical fitness by testing the Pender's revised health promotion model, and to help the patients with rheumatoid arthritis and osteoarthritis perform the continous exercise program, and to help them maximize the physical effect such as muscle strength, endurance, and functional status and mental effects including self efficacy and quality of life, and improve the physical and mental well being, and to provide a basis for the nursing intervention strategies. Of the selected variables in this study, the endogenous variables included the physical fitness, exercise score, exercise participation, perceived benefits of action, perceived barriers of action to exercise, activity-related affect(depression) and perceived self-efficacy, interpersonal influences(family support), situational factors(duration of arthritis, fatigue) and the exogenous variables included personal sociocultural factor(education level), personal biologic factor(body mass index), personal psychologic factor(perceived health status) and prior related behavior factors(previous participation in exercise, life-style). We analyzed the clinical records of 208 patients with rheumatoid arthritis and degenerative arthritis who visited the outpatient clinics at H university hospital in Seoul. Data were composed of self reported qustionnaire and good of fitness score which were obtained by padalling the ergometer of bicycle for 9 minutes. SPSS Win 8.0 and Window LISREL 8.12a were used for statistical analysis. Of 75 hypothetical paths that influence on physical fitness, exercise participation, exercise score, perceived benefits of action, perceived barriers of action to exercise, activity-related affect(depression) and perceived self-efficacy, interpersonal influences(family support), situational factors(duration of arthritis, fatigue), 40 were supported. The physical fitness was directly influenced by life-style, perceived health status, education level, family support, fatigue, which explained 12% of physical fitness. The exercise participation were directly influenced by life-style, education level, past exercise behavior, perceived benefits of action, perceived barriers of action, depression and duration of arthritis, which explained 47% of exercise participation. Exercise score were directly affected by perceived self efficacy. BMI, life-style, past exercise behavior, perceived benefits of action, family support, perceived health status. perceived barriers of action, and fatigue, which explained 70%. Perceived benefits of action was directly influenced by BMI, life-style, which explained 39%. Perceived barriers of action were directly influeced by past exercise behavior, perceived health status, which explained 7%. Perceived self efficacy were directly influeced by level of education, perceived health status, life-style, which explained 57%. Depression were directly influeced by past exercise behavior, BMI, life-style, which explained 27%. Family support were directly influeced by life-style, perceived health status, which explained 29%. Fatigue were directly influeced by BMI, life-style, perceived health status. which explained 41%. Duration of arthritis were directly influeced by life-style, past exercise behavior, BMI, which explained 6%. In conclusion, important variables for physical fitness were life-style, and variable affecting exercise participation were life-style. Perceived self-efficacy of exercise was a significant predictor of exercise score. BMI, Life-style, perceived benefits of action, family support, past exercise behavior showed direct effects on perceived self-efficacy. Therefore, disease related factor should be minimized for physical performance and well being in nursing intervention for patients with rheumatoid arthritis, and plans to promote and continue exercise should be seeked to reduce disability. In addition, Exercise program should be planned and performed by the exact evaluation of exercise according to the ability of the patients and the contents to improve the importance of exercise and self efficacy in self control program, dedicated educational program should be involved. This study suggest that the methods to reduce the disease related factors, the importance of daily life-style, recognition of benefit of exercise, and educational program to promote self efficacy should be considered in the exercise behavior promotion and nursing intervention for continous performance. The significance of this study is also thought to provide patients with chronic arthritis the specific data for maximal physical and mental well being through exercise, chronic therapeutic procedure, daily adaptation and confrontation in nursing intervention.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF