• 제목/요약/키워드: Functional Measurement

검색결과 904건 처리시간 0.036초

Magnetoencephalography (MEG)의 임상적 유용성 (Magnetoencephalography and Clinical Application)

  • 박현미;신동진
    • Annals of Clinical Neurophysiology
    • /
    • 제1권2호
    • /
    • pp.154-159
    • /
    • 1999
  • Magnetoencephalography (MEG), the measurement of magnetic fields produced by neuronal current associated with normal and pathologic brain activities, is a totally noninvasive method for localizing functional regions of the brain. During the past several years, many clinical research centers are working to expand various fundamental functional brain regions, which can be easily localized, as well as to characterize magnetic abnormalities which accompany a wide variety of cerebral disease. At present, MEG is used in a number of clinical centers throughout the world for the presurgical functional localization of eloquent cortex, and for the non-invasive localization of epileptiform activity. And also, non-invasiveness means that it can be used for screening and repetitive follow-up measurement without concern for adverse effects. As procedures for activating various functional brain regions are standardized, and as the effects of specific cerebral diseases on the MEG are carefully documented in controlled studies, the number of routine neurological applications for MEG will increase significantly. In this paper, the basic principles of MEG are reviewed briefly with its clinical application to neurologic disease.

  • PDF

The Effect of Country-of-Origin on Customer Purchase Intention: A Study of Functional Products in Vietnam

  • Phuong, Nguyen Ngoc Duy;Dat, Nguyen Tien
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제4권3호
    • /
    • pp.75-83
    • /
    • 2017
  • This paper examines key determinants and the effect of country-of-origin on customer's purchase intention of functional food and dietary supplement product in Vietnam. Exploratory study was identified to evaluate personal and social factors on customer's buying behavior. Twenty-eight reflective constructs were adapted from literature and designed by using a seven-point Likert scale to facilitate measurement. By using non-probability convenience sampling, data was collected from a survey of 242 Vietnamese who have experienced in buying functional and supplement food. This paper employed partial least square structural equation modeling (PLS-SEM) as a technique employed to analyze the measurement and structural models. The findings provide evidence that social prestige customer perceives and their positive attitude toward functional food which are main factors influencing on consumers' purchase intention. Customer's perceived prestige plays an important role in decision-making process to purchase. The higher social prestige taken up in consumers' mind, the higher consumers' purchase intention is. Moreover, the more positive attitude customer holds toward functional food, the higher consumers' purchase intention. The research results provide useful information in current understanding of what antecedents determine factors influencing customer's intention to purchase functional food and lead to managerial implications for business strategies.

전기화학적 노이즈 저항 측정에서의 불확도 평가 (Uncertainty evaluation in electrochemical noise resistance measurement)

  • 김종집;강수연
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

서울시 배수성 아스팔트 포장의 기능적 평가 연구 (Study on the Functional Evaluation of Permeable Asphalt Concrete Pavement in Seoul City)

  • 이상염;김인태;문성호;권수안
    • 한국도로학회논문집
    • /
    • 제14권3호
    • /
    • pp.33-39
    • /
    • 2012
  • 배수성 포장에 있어 기능적 평가인 투수성 실험과 더불어 소음저감 측정을 서울시에서 시공한 구간에서 실시하였다. 소음측정은 두 가지 방법을 이용하였는데 그 방법은 Pass-by 방법과 NCPX(Novel Close Proximity) 방법을 이용하였다. Passby 방법은 교통량에 따른 소음원이 전달되는 것을 측정하는 방법이고, NCPX는 타어어와 포장 표면간의 마찰음을 측정하는 방법이다. 현장투수시험을 위해서는 총 5개의 구간에서 실시하였으며 각 구간마다 주행부와 비주행부로 나뉘어 측정하였다. 3개 구간의 Pass-by 측정을 위해서는 교통소음원 발생점으로부터 인접한 곳에서 측정을 실시하였고 또한 공원내부 혹은 단지 내부에서도 소음을 측정하였다. 마지막으로 NCPX 측정은 4군데서 실시하였다. 결과적으로 배수성 포장의 기능인 투수성과 소음저감이 2, 3년 사이에서는 그 기능을 잘 유지함을 알 수 있었다.

SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정 (SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect)

  • 정준영
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

Novel graphene-based optical MEMS accelerometer dependent on intensity modulation

  • Ahmadian, Mehdi;Jafari, Kian;Sharifi, Mohammad Javad
    • ETRI Journal
    • /
    • 제40권6호
    • /
    • pp.794-801
    • /
    • 2018
  • This paper proposes a novel graphene-based optical microelectromechanical systems MEMS accelerometer that is dependent on the intensity modulation and optical properties of graphene. The designed sensing system includes a multilayer graphene finger, a laser diode (LD) light source, a photodiode, and integrated optical waveguides. The proposed accelerometer provides several advantages, such as negligible cross-axis sensitivity, appropriate linearity behavior in the operation range, a relatively broad measurement range, and a significantly wider bandwidth when compared with other important contributions in the literature. Furthermore, the functional characteristics of the proposed device are designed analytically, and are then confirmed using numerical methods. Based on the simulation results, the functional characteristics are as follows: a mechanical sensitivity of 1,019 nm/g, an optical sensitivity of 145.7 %/g, a resonance frequency of 15,553 Hz, a bandwidth of 7 kHz, and a measurement range of ${\pm}10g$. Owing to the obtained functional characteristics, the proposed device is suitable for several applications in which high sensitivity and wide bandwidth are required simultaneously.

노인의 건강사정도구에 대한 일고찰 - 신체기능 측정도구를 중심으로 - (A Study of the Scale to Measure Health Status of the Elderly - In Regard to Measures of Physical Functioning-)

  • 이선자;오진주
    • 한국보건간호학회지
    • /
    • 제6권2호
    • /
    • pp.11-20
    • /
    • 1992
  • The major goal of caring the elderly is not to cure the patient, but rather to improve or maintain the individual functional ability. With the aged population increases, there is increasing consensus among health care workers about the importance of developing a tool to measure and evaluate the health status of the elderly. As many writers is pointing out, care of the elderly embraces the spectrum of physical-social-psychological problems and an enormous number of variables could be introudeced into the health worker's routine measurement. But such an expansive approach to measurement could have disadvantages. The purpose of this study is to introduce the measurement tools of physical functioning, perhaps the most important measure required in long-term care, which are separated into three categories of measures; general physical health, ADL, IADL. It is important that all health workers who provide care to the elderly incorporate the concepts of functional health status into the routine assessments. And continuous study about reliability and validity is needed to apply those foreign tools to Korea.

  • PDF

다기능 DO 센서용 계측시스템 개발 (Development of the Measurement System for the Multi-Functional DO Sensor)

  • 이동희;김태진;최복길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.86-88
    • /
    • 1996
  • A method is presented for the development of the PC-based measurement system on the 6 cathodes-single anode type multi-functional oxygen electrodes for detecting various components of the solution by measuring the dissolved oxygen(DO) concentration. The system is consisted with the 6 channel sensor signal modyfing circuits for the sensor and the PC interface circuits using the single chip microprocessor 80c196kc. Typical polarograms for the DO probes under test using this sensor circuits are presented. This system covers wide range of measuring time from 300sec to over 16 hour in one measurement step by programming the 9 monitor disply mode.

  • PDF

Effectiveness of A Proposed Program for Training Social Studies Teachers in the Light of Electronic Functional Competencies

  • Atef Mohamed Saied, Abdallah
    • International Journal of Computer Science & Network Security
    • /
    • 제22권12호
    • /
    • pp.139-145
    • /
    • 2022
  • The study aimed to build a proposed program for training Social Studies teachers in the light of electronic functional competencies, the researcher used the experimental method with a quasi-experimental design, the study sample consisted of (37) Social studies teachers in Ismailia. A proposed program in the light of electronic functional competencies. A measure of awareness of the dimensions and components of electronic feasibility. The study concluded several results: There is a statistically significant difference at the level of (a ≤0.01) between the average scores of the teachers of the research group in the pre and post measurements of the measure of awareness of the dimensions and components of electronic functional competencies in favor of the teachers scores in the post-measurement. Training Social studies teachers on the functional electronic competencies necessary for them to keep up with educational developments.

Thermal behavior and rheology of polypropylene and its blends with poly($\varepsilon$-caprolactone)

  • Chun, Yong-Sung;Minsoo Han;Park, Junghoon;Kim, Woo-Nyon
    • Korea-Australia Rheology Journal
    • /
    • 제12권2호
    • /
    • pp.101-105
    • /
    • 2000
  • The crystallization behavior of homo polypropylene (PP) and PP in the PP-poly($\varepsilon$-caprolactone) (PCL) blends during isothermal crystallization has been investigated using differential scanning calorimeter (DSC) and advanced rheometric expansion system (ARES). From the storage modulus data of the homo PP and PP-PCL blends during isothermal crystallization, the volume fraction of crystallized material ($X_t$) of the homo PP and PP in the PP-PCL blends was calculated using the various rheological models. The results of $X_t$ of the homo PP and PP in the PP-PCL blends from ARES measurement were compared with the results from DSC. The $X_t$ of the homo PP was found to be higher in the ARES measurement than in the DSC. The crystallization rate of the homo PP was found to be faster in the rheological measurements than in the thermal analysis. The $X_t$ of PP in the PP-PCL blends with various compositions was obtained from the thermal analysis and rheological measurements. The $X_t$ of PP in the PP-PCL blends obtained from the thermal analysis and rheological measurements are not consistent. This discrepancy of $X_t$ may be due to the morphological changes resulted from the different crystallization kinetics of PP in the PP-PCL blends.

  • PDF