• Title/Summary/Keyword: Functional Measurement

Search Result 914, Processing Time 0.024 seconds

Comparative Analysis of Pain Disorder Factors and Subjective Pain Reduction Effect after Functional Adjustment Procedure Therapy for Shoulder Pain Patients (직장인 어깨 통증 환자의 기능교정 치료 후 통증 장애 요인과 자각적 통증 감소 효과 비교분석)

  • Kim, Hee-Hyeon;Lim, Dong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.87-99
    • /
    • 2020
  • PURPOSE: This study examines the therapeutic effect of functional adjustment procedure therapy (FAPT), by comparatively analyzing behavioral disorders due to shoulder pain and subjective pain intensity subsequent to therapy, in patients with shoulder pain. METHODS: The intervention was performed on 48 employee patients with shoulder pain, Patients were administered 16 sessions of FAPT for 8 weeks, twice a week for 30 minutes per session. This study applied the neck pain and disability scale (NPDS) as a measurement tool, and used the questionnaire to measure subjective pain intensity to investigate the difference before and after administering FAPT to employee patients with shoulder pain. RESULTS: Statistically significant difference was obtained between the mean difference in shoulder pain disorder, before and after FAPT. Assessing gender and age differences in the reduction effect of shoulder pain, showed significant difference in 8 of the 10 factors examined. Finally, examining the difference in the effect of reducing subjective shoulder pain by gender and age, we observed that gender-based disability reduction was significant for all 12 factors examined. CONCLUSION: Taken together, the results of this study, validate the therapeutic efficacy of FAPT for patients with shoulder pain. We believe that this data will provide basic information to understand the health conditions and psychological variables of patients with shoulder pain.

Angle Sensors Based on Oblique Giant Magneto Impedance Devices

  • Kim, Do-Hun;Na, Ji-Won;Jeung, Won-Young
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.42-46
    • /
    • 2009
  • The measurement of external magnetic field orientation using Giant Magneto Impedance (GMI) sensors has been performed. A soft magnetic alloy of $Co_{30}Fe_{34}Ni_{36}$ was electroplated on a Si wafer with a CoFeNi seed layer. V-shaped microwire patterns were formed using a conventional photolithography process. An external magnetic field was generated by a rectangular AlNiCo permanent magnet. The reference direction was defined as the external magnetic field direction oriented in the middle of 2 GMI devices. As the orientation of the magnetic field deviated from the reference direction, variation in the field component along each device introduced voltage changes. It was found that, by taking the voltage difference between the left and right arms of the Vshaped device, the nonlinearity of each device could be significantly reduced. The fabricated angle sensor had a linear range of approximately $70^{\circ}$ and an overall sensitivity of approximately 10 mV.

Determinants of Self-rated Health in Sedentary Older Adults (규칙적 신체활동을 수행하지 않는 고령자의 주관적 건강평가에 영향을 미치는 요인)

  • Hong, Seung-Youn
    • Korean Journal of Health Education and Promotion
    • /
    • v.25 no.4
    • /
    • pp.67-82
    • /
    • 2008
  • Purpose: The objective of this study were to examine the determinants of self-rated health, specially focused on the effect of functional capacity of community dwelling sedentary older adults on self-rated health. Method: The data has been collected from 654 community-dwelling sedentary older adults (mean age: 75 years) during the period from April to June in 2007. The data were collected by the in-person interview and direct measurement of functional capacity. The data were analyzed using chi-square test and multiple regression analysis with the SPSS 9.1 program. Result: The elderly rated their health as very good (3%), good (28%), fair (38%), poor (29%0, and very poor (2%). The higher average daily walk minutes ($\beta$=0.12, p<.01), number of chair stand ($\beta$=0.10, p<.05), scores of self-efficacy ($\beta$=0.16, p<.001) and the lower number of disease ($\beta$=-0.44, p<.001) show better self-rated health. Conclusion: Self-rated health is the most commonly used indicators in social epidemiology and geriatric research because it has been known as the good predictor of mortality and reflects health related disability. The finding suggested that daily walking habits, lower body strength, physical self-efficacy should be considered to improve the senior's self-perception of health. The community-based intervention associate increase these factors should be considered.

Assessment of Zinc Requirement for Human (인체의 아연필요량 측정방법)

  • 윤진숙
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.2
    • /
    • pp.346-353
    • /
    • 1995
  • The dietary requirement for zinc to maintain optimally the various metabolic and physiological funcitons is still under study. Human beings adapt to reductions in zinc intake by reducing the rate of growth or zinc excretion. Reductions in dietary zinc beyond the capacity to maintain homeostasis lead to utilization of zinc from an exchangeable pool. Loss of a small, critical amount of zinc from this pool leads to both biochemical and clinical signs of zinc deficiency. Zinc requirements have been assessed by balance studies and factorial method. As tissue zinc status influences endogenous losses and the dietary needs, individuls in good status may require higher amounts of zinc than those in poor status. While plasma zinc is insensitive to reducitons in dietary zinc, it is regarded as a valid, useful indicator of the exchangeable pool of zinc. Plasma metallothionein concentrations may prove useful for identifying poor zinc status. It has been suggested that functional end point measurement is the new direciton for zinc requirement. However, determination of the functional response to a marginal zinc intake is difficult because of the lack of a specific, sensitive indicator of zinc status. Presently, no good method for assessment of human zinc requirements exists.

  • PDF

The effect of gait training with an elastic ankle-foot orthosis on balance and walking ability of persons with chronic stroke: a randomized controlled trial

  • Chi, Ming Hao;Yim, Jong Eun;Yi, Dong hyun
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.4
    • /
    • pp.222-229
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the effect of treadmill exercise on the posture and walking speed of chronic stroke survivors with an ankle-foot orthosis. Design: Randomized controlled trial. Methods: Twenty-four chronic persons with chronic stroke admitted to Bobath Memorial Hospital in Seongnam city were divided into two groups by random blind method. Treadmill exercise with an elastic ankle-foot orthosis was performed in the experimental group and treadmill exercise was performed in the control group. The experiment was carried out for 6 weeks, and the experiment was carried out three times a week for 20 minutes per session. To measure the effect, static balance was measured using the MTD system before and after training, and the Berg Balance Scale (BBS) was used to measure functional balance. Results: There was a statistically significant difference between the 2 groups in the BBS measurement results for confirming the functional balance (p<0.05). Also, there was a significant difference between the 2 groups in single limb support time, step time and step length (p<0.05). Conclusions: In this study, it was found that treadmill exercise with an elastic ankle-foot orthosis in persons with chronic stroke was effective in maintaining functional balance, walking ability, step length, and step time. Therefore, it is necessary to use a flexible ankle-foot orthosis with proper treadmill exercise as a method of improving balance and walking speed of chronic stroke survivors.

The Effect of Water Droplets on the Nano Particle Size Distribution using the SMPS System (SMPS 시스템에서 용매(물)가 나노입도측정결과에 미치는 영향)

  • Hwangbo, Seon-Ae;Chu, Min-Cheol
    • Journal of Powder Materials
    • /
    • v.20 no.2
    • /
    • pp.129-133
    • /
    • 2013
  • In this paper we have studied the effect of water droplet size on nano-particle size distribution using SMPS(Scanning Mobility Particle Sizer)system. It can be seen that the unknown peak at >100 nm was caused by water droplets which did not dry completely when DI water was used as a solvent in the SMPS system. Therefore, it is important to dry water droplets generated from atomizer in the SMPS system when measuring the particle size distribution using less than 100 nm nano-particles in diameter. From this study, It can be concluded that the napion was a useful material as dryer ones and using EAG(Electro Aerosol Generator) as a particle generator was the most effective in reducing the effect of water droplets.

Preparation and Properties of Silicone Hydrogel Material Containing Silane Group with Cobalt Oxide Nanoparticles through Thermal Polymerization

  • Lee, Min-Jae;Kong, Ki-Oh;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.30 no.6
    • /
    • pp.273-278
    • /
    • 2020
  • This research is conducted to analyze the compatibility of used monomers and produce the high functional hydrogel ophthalmic polymer containing silane and nanoparticles. VTMS (vinyltrimethoxysilane), TAVS [Triacetoxy(vinyl)silane] and cobalt oxide nanoparticles are used as additives for the basic combination of SilM (silicone monomer), MMA (methyl methacrylate) and MA (methyl acrylate). Also, the materials are copolymerized with EGDMA (ethylene glycol dimethacrylate) as cross-linking agent, AIBN (thermal polymerization initiator) as the initiator. It is judged that the lenses of all combinations are optically excellent and thus have good compatibility. Measurement of the optical and physical characteristics of the manufactured hydrophilic ophthalmic polymer are different in each case. Especially for TAVS, the addition of cobalt oxide nanoparticles increases the oxygen permeability. These materials are considered to create synergy, so they can be used in functional hydrogel ophthalmic lenses.

Electrochemistry Characterization of Metal Using Corrosion Inhibitors Containing Amide Functional Group (아미드 작용기를 가진 부식억제제를 사용한 금속의 전기화학적 특성)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.48-56
    • /
    • 2011
  • In this study, we investigated the C-V diagrams and metal surface related to the electrochemistry characterization of metal(nickel, SUS-304). We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. A measuring range was reduced from initial potential to -1350mV, continuously oxidized to 1650 mV and measured to the initial point. The scan rate were 50, 100, 150, 200 and 250 mV/s. As a result, the C-V characterization of metal using N,N-dimethylacetamide and N,N-dimethylformamide inhibitors appeared irreversible process caused by the oxidation current from the cyclic voltammogram. After adding organic corrosion inhibitors, adsorption film constituted, and the passive phenomena happened. According to the results by cyclic voltammetry method, it was revealed that the addition of inhibitors containing amide functional group enhances the corrosion resistance properties.

Chemical Properties of Semiconductive Shield (반도전 재료의 화학적 특성)

  • Ahn, Jong-Hyun;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.203-206
    • /
    • 2008
  • To improve mean-life and reliability of power cable in this study, we have investigated chemical properties showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Chemical properties of specimens was measured by FT-ATR (Fourier Transform Attenuated Total Reflectance). The condition of specimens was a solid sheet. We could observe functional group (C=O, carbonyl group) of specimens through FT-ATR. From these experimental result, the concentration of functional group (C=O) was high according to increasing the content of carbon black. We could know EEA was excellent more than other specimens from above experimental results.

  • PDF

A Study on the Crotch Length for Dance Movement (무용동작을 위한 밑위길이에 관한 연구)

  • Yoon, Sung-Hwa;Lee, Young-Ju
    • Korean Journal of Human Ecology
    • /
    • v.11 no.1
    • /
    • pp.45-58
    • /
    • 2002
  • The purpose of this study was to offer a more functional slacks by analyzing its crotch length. The result of the study were as follows : Regarding the feeling of wearing and appearance, the P2 b style which measures the crotch length starting from the waist line passing around the iliac spine was the most highly evaluated. This suggested that the functionality of dance movement was more influenced by the position of the waist line not by the crotch length measurement. Since the front and rear center lines of the crotch could not be flown if the waist line of slacks was positioned high, both the crotch and abdominal part might be clogged or tightened when dancers made large dance movements or bended their upper bodies forward. In conclusion, slacks for more functional dance movement should be manufactured focusing on the location of the waist line rather than on the crotch length.

  • PDF