• 제목/요약/키워드: Functional Device

검색결과 600건 처리시간 0.037초

높이 보정이 가능한 자동4점 Optical PICK-UP Skew 조정장치 구현 (Implementation of Automatic 4 Points OPU Skew Adjustment Device with Height Compensation)

  • 오동규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1095-1096
    • /
    • 2008
  • By adding height compensation to the usual 3 points skew adjustment device, an improved functional skew adjustment device is implemented in this paper. The proposed skew adjustment device is for traverse which will be adapted to BD and HD player system requiring more accuracy. and It can adjust not only R/T skew but also height. The system is composed of personal computer, control box, kinematic mechanism device and bar-code reader device. Application programs are implemented by visual basic.

  • PDF

The Characteristics of Molecular Conjugated Optical Sensor Based on Silicon Nanowire FET

  • 이동진;김태근;황동훈;황종승;황성우
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.486-486
    • /
    • 2013
  • Silicon nanowire devices fabricated by bottom-up methods are attracted due to their electrical, mechanical, and optical properties. Especially, to functionalize the surface of silicon nanowires by molecules has received interests. The changes in the characteristics of the molecules is delivered directly to the surface of the silicon nanowires so that the silicon nanowire can be utilized as an efficient read-out device by using the electronic state change of molecules. The surface treatment of the silicon nanowire with light-sensitive molecules can change its optical characteristics greatly. In this paper, we present the optical response of a SiNW field-effect-transistor (FET) conjugated with porphyrin molecules. We fabricated a SiNW FET and performed porphyrin conjugation on its surface. The characteristic and the optical response of the device shows a large difference after conjugation while there is not much change of the surface in the SEM observation. It attributed to the existence of few layer porphyrin molecules on the SiNW surface and efficient variation of the surface potential of the SiNW due to light irradiation.

  • PDF

Angle Sensors Based on Oblique Giant Magneto Impedance Devices

  • Kim, Do-Hun;Na, Ji-Won;Jeung, Won-Young
    • Journal of Magnetics
    • /
    • 제14권1호
    • /
    • pp.42-46
    • /
    • 2009
  • The measurement of external magnetic field orientation using Giant Magneto Impedance (GMI) sensors has been performed. A soft magnetic alloy of $Co_{30}Fe_{34}Ni_{36}$ was electroplated on a Si wafer with a CoFeNi seed layer. V-shaped microwire patterns were formed using a conventional photolithography process. An external magnetic field was generated by a rectangular AlNiCo permanent magnet. The reference direction was defined as the external magnetic field direction oriented in the middle of 2 GMI devices. As the orientation of the magnetic field deviated from the reference direction, variation in the field component along each device introduced voltage changes. It was found that, by taking the voltage difference between the left and right arms of the Vshaped device, the nonlinearity of each device could be significantly reduced. The fabricated angle sensor had a linear range of approximately $70^{\circ}$ and an overall sensitivity of approximately 10 mV.

만성 요통 및 하지방사통 환자에서 감압치료(KNX $7000^{(R)}$)와 견인치료의 단기 치료 효과 (The Short Term Effects of the Decompression (KNX $7000^{(R)}$) and Traction Device on Pain in Patients with Chronic Low Back Pain with or without Radicular Pain)

  • 박소현;김철승;이동규;안상호
    • The Journal of Korean Physical Therapy
    • /
    • 제23권5호
    • /
    • pp.29-34
    • /
    • 2011
  • Purpose: The purpose of this study is to evaluate the short term effects of the traction and decompression device, which is a newly developed domestic medical device, on pain and functional activity in patients with chronic low back pain with or without radicular pain. Methods: Forty patients with chronic low back pain were included and allocated to decompression (n=20) and traction groups (n=20). They received decompression or traction therapy for 20 minutes a day, 3 days per week for two weeks. For evaluating pain and functional activity, a visual analogue scale (VAS) for low back pain and the Oswestry back pain disability index (ODI) were obtained on pre-treatment, and at 6, 12 and 15 days after treatment. Patients'satisfaction levels were measured 15 days after treatment. Results: VAS was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in both groups (p<0.05). ODI was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in the decompression group (p<0.05). However, there was no significant difference between the two groups in the VAS and ODI scales (p>0.05). Patients' satisfaction levels were significantly higher in the decompression group than in the traction group (p<0.05). Conclusion: These findings suggest that decompression therapy might be effective for increasing functional activity in patients with low back pain and could provide patients with higher satisfaction than traction therapy. This study provided validity data for the therapeutic effects of the decompression device in patients with low back pain and it will be useful for medical cost development and patient education of this device.

InP/ZnSe/ZnS: A Novel Multishell System for InP Quantum Dots for Improved Luminescence Efficiency and Its application in a Light-Emitting Device

  • Ippen, Christian;Greco, Tonino;Wedel, Armin
    • Journal of Information Display
    • /
    • 제13권2호
    • /
    • pp.91-95
    • /
    • 2012
  • Indium phosphide (InP) quantum dots (QDs) are considered alternatives to Cd-containing QDs for application in light-emitting devices. The multishell coating with ZnSe/ZnS was shown to improve the photoluminescence quantum yield (QY) of InP QDs more strongly than the conventional ZnS shell coating. Structural proof for this system was provided by X-ray diffraction and transmission electron microscopy. QY values in the range of 50-70% along with peak widths of 45-50 nm can be routinely achieved, making the optical performance of InP/ZnSe/ZnS QDs comparable to that of Cd-based QDs. The fabrication of a working electroluminescent light-emitting device employing the reported material demonstrated the feasibility of the desired application.

Novel graphene-based optical MEMS accelerometer dependent on intensity modulation

  • Ahmadian, Mehdi;Jafari, Kian;Sharifi, Mohammad Javad
    • ETRI Journal
    • /
    • 제40권6호
    • /
    • pp.794-801
    • /
    • 2018
  • This paper proposes a novel graphene-based optical microelectromechanical systems MEMS accelerometer that is dependent on the intensity modulation and optical properties of graphene. The designed sensing system includes a multilayer graphene finger, a laser diode (LD) light source, a photodiode, and integrated optical waveguides. The proposed accelerometer provides several advantages, such as negligible cross-axis sensitivity, appropriate linearity behavior in the operation range, a relatively broad measurement range, and a significantly wider bandwidth when compared with other important contributions in the literature. Furthermore, the functional characteristics of the proposed device are designed analytically, and are then confirmed using numerical methods. Based on the simulation results, the functional characteristics are as follows: a mechanical sensitivity of 1,019 nm/g, an optical sensitivity of 145.7 %/g, a resonance frequency of 15,553 Hz, a bandwidth of 7 kHz, and a measurement range of ${\pm}10g$. Owing to the obtained functional characteristics, the proposed device is suitable for several applications in which high sensitivity and wide bandwidth are required simultaneously.

마비된 말단근육의 제어를 위한 휴대용 다중 채널의 기능적 전기자극(FES) 장치 (A portable multichannel FES system for control of paralyzed extremities)

  • 류영재;박봉기;김영민;임영철;김하경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.90-94
    • /
    • 1992
  • A portable multichannel functional electrical stimulation(FES) system for the fine control of the paralyzed extremities in spinal cord injury patients is described. This system is composed of a stimulation data creating system, a serial communication device, a 16-bit microprocessor, D/A converter of 32 channels and a display device. Stimulation patterns are created from analytical results of integrated EMGs during motion in normal subjects and are stored in the stimulation data creating system as data files. And then the stimulation patterns are sent to the memory in the portable multichannel FES system through serial communication interfacing device. Sophisticated fine control of paralyzed extrimities was realized by transmitting multichannel stimulation patterns to percutaneous intramuscular electrodes, which stimulate the motor function of paralyzed muscle simultaneously. Advantages of this system are as follws: 1) It is possible to modify stimulation patterns in accordance with the patient's situation. 2) This system is small and light.

  • PDF

Development of Click Chemistry in Polymerization and Applications of Click Polymer

  • Karim, Md. Anwarul
    • 고무기술
    • /
    • 제13권1호
    • /
    • pp.1-9
    • /
    • 2012
  • Click chemistry had enjoyed a wealthy decade after it was introduced by K.B.Sharpless and his co-worker on 2001. Since there is no optimized method for synthesis of click polymer, therefore, this paper introduced three click reaction methods such as catalyst, non-catalyst and azide-end capping for fluorene-based functional click polymers. The obtained polymers have reasonable molecular weight with narrow PDI. The polymers are thermally stable and almost emitted blue light emission. The synthesized fluorene-based functional click polymers were characterized to compare the effect of click reaction methods on polymer electro-optical properties as well as device performance on quasi-solid-state dye sensitized solar cells (DSSCs) applications. The DSSCs with configuration of $SnO_2:F/TiO_2/N719$ dye/quasi-solid-state electrolyte/Pt devices were fabricated using these click polymers as a solid-state electrolyte components. Among the devices, the catalyzed click polymer composed device exhibited a high power conversion efficiency of 4.62% under AM 1.5G illumination ($100mW/cm^2$).These click polymers are promising materials in device application and $Cu^I$-catalyst 1, 3-dipolar cycloaddition click reaction is an efficient synthetic methodology.

  • PDF

멀티모드 단말기의 라디오 라이브러리를 위한 표준 기능 블록의 선정 및 구현 (Selection and implementation of Standard Functional Blocks for Radio Library in multi-mode mobile device)

  • 정일도;최승원
    • 디지털산업정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.125-132
    • /
    • 2016
  • The European Telecommunication Standards Institute (ETSI) Technical Committee (TC) Reconfigurable Radio Systems (RRS) is standardizing the multi-mode Mobile Device (MD). The configuration of multi-mode MD is determined by the downloaded mobile communication standard software. In this paper, we introduce the Radio Library concept for multi-mode MD which is one of the key components of RRS standard. This paper also introduces the Standard Functional Block which is a part of Radio Library. A method for selecting efficiency SFBs for multi-mode MD is presented and a Radio Library is generated based on the selected SFBs. This paper also shows sample Standard Functional Block Set which included in Radio Library. In order to verify the compatibility of the generated Radio Library which was made by C language, we implement the LTE Rel-10 and Wi-Fi(802.11b) to show the efficiency of generating a mobile communication standard software based on the Radio Library. Then using the Prograph Visual Programming MartenTM 1.6.4, we compiled our LTE Rel-10 and Wi-Fi(802.11b) source code.