• Title/Summary/Keyword: Full-scale test

Search Result 1,161, Processing Time 0.028 seconds

The Analysis of the School Foodservice Employees' Knowledge and Performance Degree of HACCP System in Jeju (제주지역 학교급식 조리종사자의 HACCP 관련 지식 및 수행도 분석)

  • Song, Im-Sook;Chae, In-Sook
    • Journal of Nutrition and Health
    • /
    • v.41 no.8
    • /
    • pp.870-886
    • /
    • 2008
  • The purposes of this study were to (a) analyze school foodservice employees' knowledge and performance degree of HACCP system and (b) provide the basic data for planning the strategies which can be performed for systematic HACCP system in school foodservice. For these purposes, the subjects included 91 dieticians (a response rate 98.9%) and 270 foodservice employees (a response rate 98.2%) at school in Jeju city and they were surveyed from October 21 to November 4, 2006. The data were analyzed by descriptive analysis, reliability analysis, t-test, ANOVA (Duncan multiple range test) and Pearson's correlation coefficients using the SPSS Win Program (version 12.0). In terms of the number of training practice, the result of sanitary training indicated that the dieticians who trained the employees more than once per a week (48.6%) or everyday (36.3%) were 84.7%. And the dieticians who were higher age, full-time job, and working at middle school implemented significantly more training the employees. In the training methods, 40.7% of dieticians used the oral presentation and 37.4 % utilized the printed matters. Also, most of employees (98.1%) have experienced for the training, 39.6% of them did not have regular training experience and 40.7% of them responded that they were understanding the HACCP system well. The result of employees' knowledge level of HACCP system reported that the items of the personal hygiene scored the highest (92.3 points) whereas the items of CCP3 scored the lowest (58.3 points) as the average being 84.2 points (out of 100 scale). In terms of the performance degree of HACCP system, the average was 4.40 (out of 5 scale), the items of the personal hygiene scored the highest as 4.51 whereas the items of CCP2 scored the lowest as 4.31 points. The dieticians' perception degree of employees' performance degree in HACCP system showed that the average was 4.13 (out of 5 scale), so it was significantly lower than actual performance degree as average 4.40 (out of 5 scale). Additionally the employees' knowledge level was positively correlated to performance degree and employees' knowledge level of CCP3, CCP4, and the personal hygiene significantly influenced to the HACCP performance degree. Finally, the dieticians have to recognize correctly the employees' performance degree and on the basis of it must plan the sanitary training which has a proper contents and methods to enhance the employees' knowledge level and achieve more systematic HACCP system in school foodservice.

Executive Dysfunction and It's Relation to K-WAIS Scores in Mild Traumatic Brain Injury Patients with Normal Intelligence Quotient (정상 지능의 경도 외상성 뇌손상 환자에서 실행기능 장애 및 K-WAIS 점수들과의 관련성)

  • Lee, Dae-Bo;Yoon, In-Seon;Kim, Seon-Kyung;Rho, Seung-Ho;Park, Min-Cheol;Lee, Sang-Yeol
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.20 no.1
    • /
    • pp.50-58
    • /
    • 2012
  • Objectives : This study examined the selective deficits of executive function in patients with mild traumatic brain injury that in normal range of general intelligence level and aimed to analysis of the correlation between K-WAIS result and executive function. Methods : 59 subjects were included in this study, who were diagnosed as mild traumatic brain injury(MTBI) and they have visited in neuropsychiatric department of Wonkwang University Hospital during from March, 2005 to September, 2010. For measurement of general intelligence quotient, the Korean-Wechsler Adults Intelligence Scale(K-WAIS) was administered and for measurement of executive intelligence quotient(EIQ), Executive Intelligence Test(EXIT) was administered. Results : Of patients, 50.8% included at abnormal EIQ group. The patients of abnormal EIQ showed poorer full scale IQ(FIQ), performance IQ(PIQ) and in subscale that picture arrangement, digit symbol, digit span, block design, object assembly and comprehension were significantly different. In terms of relationships between K-WAIS and EIQ, FIQ and PIQ have positive correlation with EIQ. And in subscale, picture arrangement, digit symbol, digit span, block design, object assembly and comprehension show positive correlation with EIQ. Conclusion : This study suggest that MTBI patients with have normal range of general intelligence level may have deficit of executive function is common. The decline of FIQ, PIQ and some subscales of K-WAIS may suggest executive dysfunction in MTBI patients.

  • PDF

An Experimental Study on the Seismic Performance of Shear Connections and Rib Plate H Beam to Column Connections (전단접합 및 리브 플레이트로 보강한 H형 보-기둥 접합부의 내진성능에 관한 실험적 연구)

  • Oh, Kyung Hyun;Seo, Seong Yeon;Kim, Sung Yong;Yang, Young Sung;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.569-580
    • /
    • 2005
  • The postbeam joint connection of the existing steel structure moment flexible frame system did not produce sufficient seismic resistance during the earthquakes in Northridge and Kobe, and it sustained brittle fracturing on the joint connection. This study was performed to execute the high-tensile bolt share connection of H-beams web and the full-scale experiment as a parameter of the existing reinforcement of H-flange rib, by making the shape of the existing joint connection. This experiment was performed to determine the extent of the decrease of the number of high-tensile bolts and how to improve workability of the two-phase shear connection of web beam. In addition, this study was performed to enhance the seismic resistant capacity through the enforcement of rib plates. As a result of the experiment of two-phase shear connection of H-beam web and of joint connection to be reinforced by rib plates, the results of this study showed that the initial stiffness, energy-dissipation capacity, and rotational capacity of plasticity was higher than the existing joint connection. As to the rate of increasing the strength and deformation capacity, there were differences between the tension side and compression side because of the position of shear tap. However, as a whole, they have shown excellent seismic resistant capacity. Also, all the test subjects exceeded 4% (rate of delamination), about 0.029 rad (total plastic capacity), and about 130% (maximum strength of joint connection) of fully plastic moment for the original section. Accordingly, this study was considered as it would be available in the design more than the intermediate-level of moment flexible frame.

Comparative study on the performance of Pod type waterjet by experiment and computation

  • Kim, Moon-Chan;Park, Warn-Gyu;Chun, Ho-Hwan;Jung, Un-Hwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.2 no.1
    • /
    • pp.1-13
    • /
    • 2010
  • A comparative study between a computation and an experiment has been conducted to predict the performance of a Pod type waterjet for cm amphibious wheeled vehicle. The Pod type waterjet has been chosen on the basis of the required specific speed of more than 2500. As the Pod type waterjet is an extreme type of axial flow type waterjet, theoretical as well as experimental works about Pod type waterjets are very rare. The main purpose of the present study is to validate and compare to the experimental results of the Pod type waterjet with the developed CFD in-house code based on the RANS equations. The developed code has been validated by comparing with the experimental results of the well-known turbine problem. The validation also extended to the flush type waterjet where the pressures along the duct surface and also velocities at nozzle area have been compared with experimental results. The Pod type waterjet has been designed and the performance of the designed waterjet system including duct, impeller and stator was analyzed by the previously mentioned m-house CFD Code. The pressure distributions and limiting streamlines on the blade surfaces were computed to confirm the performance of the designed waterjets. In addition, the torque and momentum were computed to find the entire efficiency and these were compared with the model test results. Measurements were taken of the flow rate at the nozzle exit, static pressure at the various sections along the duct and also the nozzle, revolution of the impeller, torque, thrust and towing forces at various advance speed's for the prediction of performance as well as for comparison with the computations. Based on these measurements, the performance was analyzed according to the ITTC96 standard analysis method. The full-scale effective and the delivered power of the wheeled vehicle were estimated for the prediction of the service speed. This paper emphasizes the confirmation of the ITTC96 analysis method and the developed analysis code for the design and analysis of the Pod type waterjet system.

The Effect of Anchorage with Shear Reinforcement in Flat Plate System (플랫 플레이트 구조에서 전단보강체의 정착성능에 따른 전단보강효과)

  • Choi, Chang-Sik;Bae, Baek-Il;Choi, Yun-Cheul;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.667-675
    • /
    • 2012
  • Flat plate are being used more in buildings requiring a high level of technical installations or in buildings needing changeable room arrangements during their life time such as office buildings. The main problem in flat plate is its weak resistance against a punching failure at its slab-column connections. Therefore, in this research, an experimental study on full-scale interior slab-column connection was performed. Three types of shear reinforcements were tested to prevent brittle punching shear failure that could lead to collapse of the structure. A series of four flat plate specimens including a specimen without shear reinforcement and three specimens with shear reinforcements were tested. The slabs were tested up to failure using monotonic vertical shear loading. The presences of the shear reinforcements substantially increased punching shear capacity and ductility of the interior slabcolumn connections. The test results showed that a slab that did not have enough bond length failed before shear reinforcement yielded due to anchorage slip. Also, FEM analyses were performed to study an effect of slab thickness and concrete compressive strength on the flat plate slab. The analytical study results were used to propose a method to calculate performance capacity of shear reinforcement in slab-column connection.

A Proposal for Improved Safety Assessment Procedure of Corrugated Steel Plate Structures Using Measured Displacements (파형강판 구조물의 내공변위를 활용한 개선된 안전도 평가 절차 제안)

  • Jeon, Se-Jin;Lee, Byeong-Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.13-24
    • /
    • 2020
  • A systematic approach to assess the safety of corrugated steel plate structures has not been established yet. Therefore, an improved safety assessment procedure was proposed in this study by considering the characteristics of corrugated steel plate structures in which the dead load of backfill soil is dominant and the live load effect is minimized. The proposed procedure can consider the combined effect of axial force and bending moment on the safety, based on the Soil-Culvert Interaction (SCI) method, and can differentiate the maintenance scheme according to the calculated plasticity index. There is also an advantage in enhancing the accuracy of assessment, utilizing the measured displacements. Furthermore, improved methods were proposed by discussing various ways for reasonably improving the proposed assessment procedure. The safety of an actual structure and a full-scale test specimen was assessed by applying the proposed procedure. The conventional assessment procedure significantly overestimated the load-carrying capacity, whereas the proposed procedure resulted in a reasonable level of safety. Therefore, the procedure proposed in this study is expected to contribute to the establishment of proper maintenance plan such as the quantitative condition assessment and strengthening of corrugated steel plate structure.

Effect of Pad Structure and Friction Material Composition on Brake Squeal Noise (제동패드의 구조와 마찰재 조성이 제동 스킬소음에 미치는 영향)

  • Goo, Byeong Choon;Kim, Jae Chul;Lee, Beom Joo;Park, Hyoung Chul;Na, Sun Joo
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • Brake squeal noise has been a challenging problems for a long time. It is very annoying to passengers and residents near tracks. Two methods have been applied to reduce or eliminate brake squeal noise. One is to improve frictional materials; the other is to optimize the topology and structures of brake pads. In this study, we developed two kinds of brake pads; one is a pad whose frictional material is different from the KTX brake pad friction material; the other is a flexible pad that has the same frictional material as that of the KTX brake pad, but a different structure. Squeal noise and friction coefficients were measured and analyzed using a full-scale brake dynamometer. It was found that the dynamometer test can simulate the squeal noise of KTX trains at stations. The squeal frequency of the KTX at 4500Hz was exactly reproduced; this value of 4500Hz was one of the natural frequencies of the KTX brake disc. It was also found that the squeal noise depended on the caliper pressure, initial disc temperature and braking speed. The average friction coefficient was 0.35~0.45. The new pad lowered the squeal noise by 17.3~21.6dB(A).

Identification of Compliance Function for Early-Age Concrete Based on Measured Strain & Thermal Stress Histories (변형률 및 열응력 이력 계측을 통한 초기재령 콘크리트의 컴플라이언스 함수 추정)

  • Oh, Byung-Hwan;Shin, Joon-Ho;Choi, Seong-Cheol;Cha, Soo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.662-669
    • /
    • 2003
  • Recently, the serviceability and durability of concrete structures under thermal load have received great attention. The thermal stress and clacking behavior of concrete at early ages are one of the important factors that affect such serviceability and durability of concrete structures. Nevertheless, most studies on the behavior of early-age concrete have been confined to the temperature and strain development itself in the laboratory. The desirable efforts to explore the material properties of concrete at early-ages have not been made extensively so far. The purpose of the present study is, therefore, to identify some important material properties that affect the stress behavior of concrete at early-ages. To this end, full-scale concrete base-restrained wall members have been fabricated, and many sensors including thermocouples, strain meters and stress meters were installed inside of the wall members. These sensors were to measure the development of temperatures, strains and stresses at several location in concrete walls during the hardening and curing phase of early-age concrete. By using these measured values of strain and stress, the compliance function at early-age was identified. The basic form of compliance function derived in this study follows the double-power law. However, the results of present study indicate that the values of existing compliance functions are much lower than actual values, especially at very early-ages. It can be seen that the prediction of stresses of early-age concrete based on the proposed compliance function agrees very well with test data. The present study allows more realistic evaluation of varying stresses in early-age concrete under thermal load.

Determination of Adequate Method for Protein Extraction from Rice Bran and the Substitution of Dried Skim Milk with Protein Concentrate from Rice Bran in Early Weaned Pigs

  • Phipek, W.;Nagasinha, C.;Vallisuth, S.;Nongyao, C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.9
    • /
    • pp.1268-1273
    • /
    • 2011
  • The present study was conducted to determine a feasible method of protein concentrate extraction from rice bran (RBPC) and its effect as a substitution for skim milk in early weaning pig diets. An investigation to extract protein concentrate from full fat rice bran was undertaken to determine the best ratio of water and rice bran, the amount of NaOH and a HCl solvent to use in a simple paddle-type mixer with modified spinning to produce RBPC. The results stated that the best ratio for water mixing in the RBPC extraction process was 1:5 with 20 g NaOH and 30 min in a paddle-type mixer at 300 rpm. A mix of 250 ml 0.2 N HCl was optimum for neutralization and protein precipitation. After the fluid was spun out with a washing machine, the sediment was left for 12-14 hours to complete the filtration. One kilogram of rice bran could produce an average of 324.5 gram RBPC and it contained 3.40% ash, 496.48 kcal of GE/100 gram, 1.94% crude fiber, 28.20% ether extract, 7.64% moisture and 16.66% crude protein, respectively. A total of 45 crossbred piglets, weaned at 3 weeks of age were allotted into control diet (A) and dietary treatments formulated with a four different rates of RBPC substitution for skim milk at a percentage of 25 (B), 50 (C), 77 (D) and 100 (E) respectively, in a randomized complete block (RCB) design. All piglets had free access to feed and water until 8 week of age when the experiment ended. Feed intake, average daily gain, growth rate and feed efficiency were not affected by dietary treatments. Blood test parameters after completion of the growth trial indicated normal health. Even though the mean of cell hemoglobin concentration was significantly different between treatments (p<0.05) it was still within the normal range. The cost difference for BW gain of 100% RBPC substituted for skim milk in the weaning diet was approximately 35% lower than that of the control and the relative cost of production was 96.67, 92.85, 70.75 and 64.48% lower for the replacement of 25, 50, 75 and 100% of skim milk respectively. These results implied that this technology is feasible for use by small scale farmers to improve their self-reliance.

Evaluation of Static and Fatigue Performances of Decks Reinforced with GFRP Rebar for Reinfocement Ratio (GFRP 보강근으로 보강된 바닥판의 보강비에 따른 정적 및 피로성능 평가)

  • You, Young-Jun;Park, Young-Hwan;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.491-497
    • /
    • 2014
  • The corrosion of steel reinforcement in reinforced concrete bridge decks significantly affects the degradation of the capacity. Due to the advantageous characteristics such as high tensile strength and non-corrosive property, fiber reinforced polymer (FRP) has been gathering much interest from designers and engineers for possible usage as a alternative reinforcement for a steel reinforcing bar. However, its application has not been widespread, because there data for short- and long-term performance data of FRP reinforced concrete members are insufficient. In this paper, seven full-scale decks with dimensions of $4000{\times}3000{\times}240mm$ were prepared and tested to failure in the laboratory. The test parameter was the bottom reinforcement ratio in transverse direction. The decks were subjected to various levels of concentrated cyclic load with a contact area of $577{\times}231mm$ to simulate the vehicle loading of DB-24 truck wheel loads acting on the center span of the deck. It was observed that the glass FRP (GFRP) reinforced deck on a restraint girder is strongly effected to the level of the applied load rather than the bottom reinforcement ratio. The study results showed that the maximum load less than 58% of the maximum static load can be applied to the deck to resist a fatigue load of 2 million cycles. The fatigue life of the GFRP decks from this study showed the lower and higher fatigue performance than that of ordinary steel and CFRP rebar reinforced concrete deck. respectively.