• 제목/요약/키워드: Full-scale structure

검색결과 445건 처리시간 0.025초

Design and performance validation of a wireless sensing unit for structural monitoring applications

  • Lynch, Jerome Peter;Law, Kincho H.;Kiremidjian, Anne S.;Carryer, Ed;Farrar, Charles R.;Sohn, Hoon;Allen, David W.;Nadler, Brett;Wait, Jeannette R.
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.393-408
    • /
    • 2004
  • There exists a clear need to monitor the performance of civil structures over their operational lives. Current commercial monitoring systems suffer from various technological and economic limitations that prevent their widespread adoption. The wires used to route measurements from system sensors to the centralized data server represent one of the greatest limitations since they are physically vulnerable and expensive from an installation and maintenance standpoint. In lieu of cables, the introduction of low-cost wireless communications is proposed. The result is the design of a prototype wireless sensing unit that can serve as the fundamental building block of wireless modular monitoring systems (WiMMS). An additional feature of the wireless sensing unit is the incorporation of computational power in the form of state-of-art microcontrollers. The prototype unit is validated with a series of laboratory and field tests. The Alamosa Canyon Bridge is employed to serve as a full-scale benchmark structure to validate the performance of the wireless sensing unit in the field. A traditional cable-based monitoring system is installed in parallel with the wireless sensing units for performance comparison.

Analytical study of failure damage to 270,000-kL LNG storage tank under blast loading

  • Lee, Sang Won;Choi, Seung Jai;Kim, Jang-Ho Jay
    • Computers and Concrete
    • /
    • 제17권2호
    • /
    • pp.201-214
    • /
    • 2016
  • The outer tank of a liquefied natural gas (LNG) storage tank is a longitudinally and meridianally pre-stressed concrete (PSC) wall structure. Because of the current trend of constructing larger LNG storage tanks, the pre-stressing forces required to increase wall strength must be significantly increased. Because of the increase in tank sizes and pre-stressing forces, an extreme loading scenario such as a bomb blast or an airplane crash needs to be investigated. Therefore, in this study, the blast resistance performance of LNG storage tanks was analyzed by conducting a blast simulation to investigate the safety of larger LNG storage tanks. Test data validation for a blast simulation of reinforced concrete panels was performed using a specific FEM code, LS-DYNA, prior to a full-scale blast simulation of the outer tank of a 270,000-kL LNG storage tank. Another objective of this study was to evaluate the safety and serviceability of an LNG storage tank with respect to varying amounts of explosive charge. The results of this study can be used as basic data for the design and safety evaluation of PSC LNG storage tanks.

Safety Evaluation of 40m Combined Modular Bridge Super-Structures Based on Transportation Lifting Methods (40m 조합모듈교량 상부구조 이송에 따른 안전성 검토)

  • Park, Sung-Min;Jung, Woo-Young
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • 제6권2호
    • /
    • pp.77-84
    • /
    • 2015
  • The purpose of this study was the analytical safety evaluation on the super-structure of precast modular bridge using standardized modular members and robotic construction during the transportation routing and lifting conditions. In order to evaluate the safety performance of the bridge system, 3-D full scale Finite Element (FE) of 40 m standardized modular block was developed in ABAQUS, followed by the analytical study to classify the structural system according to steel girder structures: 1) modular bridge block lifting method including the steel girder system; 2) modular bridge block lifting method without the steel girder system. The results from the analytical study revealed that the maximum stress of each modular member was within the maximum allowable stresses during lifting condition. However, the stress concentration at the connected area was more critical in comparison to the behavior of 40 m combined modular blocks during lifting time

Evaluation of Hydraulic Behavior within Parallel arranged Upflow Sedimentation Basin Using CFD Simulation (I) - The influence of feed water inequity- (CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(I) - 침전지 내 유입유량 불균등 영향 조사 -)

  • Park, No-Suk;Kim, Seong-Su;Choi, Jong-Woong;Sung, Youl-Boong;Kang, Moon-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제27권4호
    • /
    • pp.469-477
    • /
    • 2013
  • In order to investigate the influence of feed water inequity on the settling performance for parallel arranged upflow sedimentation basin in domestic G_WTP(Water Treatment Plant), CFD(Computational Fluid Dynamics) simulation were employed and ADV(Acoustic Doppler Velocimeter) measurements were carried out. From the results of both CFD simulations and ADV measurements, the differences among inlet flow rates to each inlet structure make turbulent energy dissipation uneven overall sedimentation basin. Especially local velocities in the near of both side wall were observed over the design overflow rate(74.4 mm/min). Also, it was confirmed that this inequity of inlet flow would exert an serious influence on the turbidity of settled water which is out from 8 troughs. Even though experimental velocities in full scale basin about 20% higher than the simulated, the results of ADV measurement were in good accordance with those of CFD simulations.

Use of Hydrazine for Pitting Corrosion Inhibition of Copper Sprinkler Tubes: Reaction of Hydrazine with Corrosion By-Products

  • Suh, Sang Hee;Kim, Sohee;Suh, Youngjoon
    • Corrosion Science and Technology
    • /
    • 제16권5호
    • /
    • pp.247-256
    • /
    • 2017
  • The feasibility of using hydrazine for inhibiting pitting corrosion in copper sprinkler tubes was investigated by examining microscopical and structural evolution of corrosion by-products with SEM, EDS, and XRD. Hydrazine removed dissolved oxygen and reduced CuO and $Cu_2O$ as well. The stable phase was changed from CuO to $Cu_2O$ or Cu depending on hydrazine concentration. Hydrazine concentration of 500 ppm could convert all CuO corrosion by-products to $Cu_2O$. In a tightly sealed acryl tube filled with aqueous solution of 500 ppm hydrazine, octahedral $Cu_2O$ particles were formed while plate-like structures with high concentration of Cu, O, N and C were formed near a corrosion pit. The inside structure of a corrosion pit was not altered by hydrazine aqueous solution. Uniform corrosion of copper was almost completely stopped in aqueous solution of 500 ppm hydrazine. Corrosion potential of a copper plate was linearly dependent on log (hydrazine concentration). The concept of stopping pitting corrosion reaction by suppressing oxygen reduction reaction could be verified by applying this method to a reasonable number of real sprinkler systems before full-scale application.

The clonal seaweed Chondrus crispus as a foundation species

  • Scrosati, Ricardo A.
    • ALGAE
    • /
    • 제31권1호
    • /
    • pp.41-48
    • /
    • 2016
  • The clonal seaweed Chondrus crispus (Rhodophyta, Gigartinales) forms extensive stands at low intertidal elevations on wave-sheltered rocky shores of the North Atlantic. This study investigates if this bushy alga acts as a foundation species in such habitats. The abundance (percent cover) of C. crispus, all other algae, and invertebrates was measured in 390 quadrats spanning 350 km of coast in Nova Scotia, Canada. In these low-intertidal habitats, fucoid algae are the largest organisms and can form extensive canopies, but their cover was unrelated to benthic species richness and to C. crispus cover. Species richness, however, increased with C. crispus cover from low to intermediate cover values, showing little change towards full C. crispus cover. Species composition (a combined measure of species identity and their relative abundance) differed between quadrats with low (0-1%) and high (60-100%) cover of C. crispus. High C. crispus cover was associated to more invertebrate species but fewer algal species than low C. crispus cover. However, the average abundance of algal and invertebrate species occurring in both cover groups was often higher under high C. crispus cover, contributing to a higher average richness at the quadrat scale. Overall, only 16% of the observed variation in species richness was explained by C. crispus cover. Therefore, this study suggests that C. crispus acts as a foundation species but with a moderate influence.

Evaluation of the Effect of Sedimentation Basin Structure on Hydrodynamic Behavior using CFD(I): The Effect of Longitudinal Baffle (CFD를 이용한 침전지 구조가 수리거동에 미치는 영향 평가(I): 도류벽의 영향)

  • Park, Se-Jin;Park, No-Suk;Lim, Jae-Lim;Kim, Sun-Kyu;Kim, Sug-Goo;Mun, Yong-Taek;Bang, Ki-Woong
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제20권5호
    • /
    • pp.667-676
    • /
    • 2006
  • This study was conducted to evaluate the effect of longitudinal baffle on hydrodynamic behavior within a certain full-scale sedimentation basin (flow rate per basin; $1,000m^3/d$). Comparative experimental investigations have been carried out on the sediment removal efficiencies and the sludge deposit distribution in the baffled and un-baffled sedimentation basin, respectively. From the results derived in the baffled and un-baffled sedimentation, the turbidity removal rate in the baffled sedimentation basin is about 38% higher than that in un-baffled. Also, the height of sludge deposit in the baffled sedimentation basin is approximately 20% lower, and the sludge concentration is 10% higher than those in un-baffled sedimentation basin. In order to explain the experimental results and investigate the effect of longitudinal baffle in more detail, we conducted Computational Fluid Dynamics (CFD) simulation. From the results of CFD simulation, the flow, especially in the near of outlet orifice, was more stable in the case of longitudinal baffled sedimentation basin than that in un-baffled basin. Also, it could be concluded that the longitudinal baffle made a fully developed flow more effective for sedimentation.

A Study on the Structure of Intelligence Measured by the K-WPPSI-IV (한국 웩슬러 유아지능검사 4판(K-WPPSI-IV)의 지능구조에 관한 연구)

  • Lee, KyungOk;Park, Hyewon;Lee, Sanghee
    • Korean Journal of Child Studies
    • /
    • 제37권6호
    • /
    • pp.107-117
    • /
    • 2016
  • Objective: This study examined the construct validity of K-WPPSI-IV. Factor structures of the structures of the K-WPPSI-IV full scale as well as primary index scales for two age ranges (2 years, 6 months to 3 years, 11 months; 4 years to 7 years, 7 months) were examined. Methods: Data were collected from 1,700 children aged 2 years, 6 months to 7 years, 7 months during the K-WPPSI-IV standardization. Confirmatory factor analyses were conducted using the K-WPPSI-IV subtest performances with maximum likelihood estimation using Amos 18. Results: First, the three-factor model (verbal comprehension, visual spatial, and working memory) fitted best for the younger age range. However, the five-factor model (verbal comprehension, visual spatial, fluid reasoning, working memory, and processing speed) fitted best for the older age range. Residuals suggest the presence of two nested subfactors within the verbal comprehension factor (broad/expressive and focused/simple). Second, the confirmatory factor analysis on primary index subtests identified factors that account for the intercorrelations among the reduced sets of primary index subtests. Conclusion: The findings showed that the theoretical structures of WPPSI-IV subtests were confirmed within K-WPPSI-IV.

Seismic analysis of a masonry cross vault through shaking table tests: the case study of the Dey Mosque in Algiers

  • Rossi, Michela;Calderini, Chiara;Roselli, Ivan;Mongelli, Marialuisa;De Canio, Gerardo;Lagomarsino, Sergio
    • Earthquakes and Structures
    • /
    • 제18권1호
    • /
    • pp.57-72
    • /
    • 2020
  • This paper presents the results of a monodirectional shaking table test on a full-scale unreinforced masonry cross vault characterized by asymmetric boundary conditions. The specimen represents a vault of the mosque of Dey in Algiers (Algeria), reproducing in detail the mechanical characteristics of masonry, and the constructive details including the presence of some peculiar wooden logs placed within the vault's abutments. The vault was tested with and without the presence of two steel bars which connect two opposite sides of the vault. The dynamic behaviour of both the vault's configurations were studied by using an incremental dynamic analysis up to the collapse of the vault without the steel bars. The use of an innovative high-resolution 3D optical system allowed measure displacement data of the cross vault during the shake table tests. The experimental results were analysed in terms of evolution of damage mechanisms, and in-plane and out-of-plane deformations. Moreover, the dynamic properties of the structure were investigated by means of an experimental modal analysis.

Standard Procedure for the Aerodynamic Design of Small Wind Turbine Blades (소형 풍력 블레이드 공력 설계를 위한 표준 절차 구축)

  • Chang, Se-Myong;Jeong, Su-Yun;Seo, Hyun-Soo;Kyong, Nam-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.473-473
    • /
    • 2009
  • There have been many academic researches on the aerodynamic design of wind turbine based on blade element method (BEM) and momentum theory (MT, or actuating disk theory). However, in the real world, the turbine blade design requires many additional constraints more than theoretical analysis. The standard procedure is studied in the present paper to design new blades for the wind turbine system ranged from the small size from 1 to 10 kW. From the experience of full design of a 10 kW blade, the authors tried to set up a standard procedure for the aerodynamic design based on IEC 61400-2. Wind-turbine scale, rotating speed, and geometrical chord/twist distribution at the segmented span positions are calculated with a suitable BEM/MT code, and the geometrical shape of tip and root should be modified after considering various parameters: wing-tip vortex, aerodynamic noise, turbine efficiency, structural safety, convenience of fabrication, and even economic factor likes price, etc. The evaluated data is passed to the next procedure of structural design, but some of them should still be corresponded with each other: the fluid-structure interaction is one of those problems not yet solved, for example. Consequently, the design procedure of small wind-turbine blades is set up for the mass production of commercial products in this research.

  • PDF